Home
American Standard Triumph 7034 User's Manual
Contents
1. E Use adjustable wrench to tighten connections Do not over tighten Be careful not to kink copper supply when bending Use tubing cutter to cut to proper length E Connect 1 1 4 O D tailpiece on POP UP DRAIN to waste outlet FLEXIBLE SUPPLIES 3 8 O D BULL NOSE RISERS 3 8 COMPRESSION COMPRESSION CONNECTION NUT M968865 Rev 1 2 9 TEST INSTALLED FITTING With HANDLES 1 in OFF position turn on WATER SUPPLIES 2 and check all connections for leaks gt Remove AERATOR 3 Operate both HANDLES 1 to flush water lines thoroughly Replace AERATOR 3 CHECK DRAIN CONNECTIONS Operate POP UP KNOB 4 and fill lavatory with water Check that DRAIN STOPPER 5 makes a good seal and retains water in SINK If DRAIN STOPPER 5 does not seal properly please refer to Troubleshooting section in these instructions Release POP UP KNOB 4 down and check all drain connections and P trap for leaks m Tighten if necessary P TRAP To change direction of handle Turn valve to OFF position Pull HANDLE ASSEMBLY 1 UP firmly to release from ADAPTER 2 Remove ADAPTER SGREW 3 from ADAPTOR 2 Pull off ADAPTER 2 Remove SPRING CLIP 4 Lift STOP WASHER 5 turn 90 and replace Replace SPRING CLIP 4 Replace ADAPTER 2 and ADAPTER SCREW 3 e Find correct position of HANDLE ASSEMBLY 1 by adjusting male teeth on ADAPTER 2 to femal E
2. teeth in HANDLE ASSEMBLY 1 Push HANDLE ASSEMBLY 1 down onto ADAPTER 4 until it snaps into place 1 1 CARE INSTRUCTIONS DO SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER DRY WITH A SOFT COTTON FLANNEL CLOTH DO NOT DO NOT CLEAN THE PRODUCT WITH SOAPS ACID POLISH ABRASIVES HARSH CLEANERS OR A CLOTH WITH A COARSE SURFACE M968865 Rev 1 2 Speed Connect Drain Troubleshooting Guide If sink does not hold water even though Stopper is in the down position e Follow CABLE ADJUSTMENT PROCEDURE If Stopper does not raise up fully or sink drains too slowly e Follow CABLE ADJUSTMENT PROCEDURE If you need to remove the tenia secs e Follow STOPPER REMOVAL PROCEDURE If you would like the ability to remove your Stopper simply by lifting it out of the drain e Follow STOPPER INSTALLATION PROCEDURE for Unlocked mode CABLE ADJUSTMENT PROCEDURE Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam in the illustration Fig B Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go At this point the Stopper should be in the UP position Fig B C Push DOWN on the Lift Knob to make sure it is fully down Fig C Re attach the Cable to the Drain Body Connection 2 by threading the Cable Connector 1 c
3. Fig B Note No plumber s putty or caulk is required The CABLE ATTACHMENT POINT 6 must face towards the rear of the SINK Fig B INSTALL BLACK GASKET Install BLACK CONE GASKET 1 onto DRAIN BODY 2 from below Note The flat side of the BLACK CONE GASKET 4 must face down FLAT SIDE OF GASKET MUST FACE DOWN INSTALL GRAY LOCKNUT Install GRAY LOCKNUT 1 onto DRAIN BODY 2 from below SINK Fig A Note The flat side of the GRAY LOCKNUT 1 must face up Tighten firmly by hand No tools are required Check DRAIN FLANGE in SINK to ensure that eine ee WHITE FOAM GASKET 3 is fully compressed GRAY LOCKNUT and not visible Fig B A MUST FACE UP 5 POP UP KNOB E POP UP KNOB 1 must be fully down M968865 Rev1 2 6 ATTACH CABLE CONNECTOR m Thread CABLE CONNECTOR 1 clockwise onto DRAIN BODY CONNECTION 2 and hand tighten Fig A Your new POP UP DRAIN installation is now complete Fig B Note Tailpeice on pop up drain is 1 1 4 0 D Fig B F CHECK OPERATION OF POP UP E Operate LIFT KNOB 1 to verify that STOPPER 2 opens and closes Note If STOPPER 2 does not open and close properly then refer to the troubleshooting section of these instructions 8 MAKE WATER SUPPLY AND WASTE CONNECTIONS NOTE FLEXIBLE SUPPLIES OR BULL NOSE RISERS MUST BE PURCHASED SEPARATELY m Connect water su ys to FAUCET 1 with 1 2 IPS FLEXIBLE SUPPLIES 2 or 3 8 0 D BULL NOSE RISERS 3
4. Installation TRIUMPH Instructions Centerset Lavatory Faucet with 7034 Speed Connect Drain Congratulations on purchasing your American Standard faucet with the Speed Connect Drain a feature found only on American Standard faucets Speed Connect Drain Certified to comply with ANSI A112 18 1 e 1 3 of the parts installs in 1 3 of the time M968865 Rev 1 2 e No tools needed e Never needs adjustment e Guaranteed to seal properly the first time every time Your new American Standard faucet is designed to work only with the Speed Connect Drain Helpful tips for removing your current drain can be found in the Troubleshooting section of these instructions To ensure that your installation proceeds smoothly please read these instructions carefully before you begin Recommended tools N Screwdriver Channel Locks Adjustable Wrench Tubing Cutter INSTALL FAUCET CAUTION Turn off hot and cold water supplies before beginning Insert FAUCET 1 and CABLE CONNECTOR 2 through mounting holes of Sink or mounting surface Fig A Assemble LOCKNUTS 3 onto SHANKS 4 from under side of Sink Hand tighten firmly Fig B HAND TIGHTEN 4 _ SINK OR MOUNTING SURFACE INSTALL POP UP DRAIN Remove CLEAR PLASTIC COVER 1 Remove CARDBOARD SPACER 2 from under DRAIN POP UP 3 Fig A Drop DRAIN BODY 4 through sink drain hole Make sure WHITE FOAM GASKET 5 is under flange of DRAIN BODY 4
5. LOW SINK METAL OR PLASTIC TWO PIECE METAL DRAIN BODY WITH PLASTIC DRAIN BODY DRAIN BODY PLASTIC TAILPIECE WITH PLASTIC TAILPIECE om STOPPE STOPPE METAL STOPPER DRAIN PLASTIC UNTHREAD BODY DRAIN BODY FLANGE SINK METAL OR NUT and 4 NUT and GASKET GASKET PIVOT L MOUNTING L MOUNTING ROD a Bae NOT PLASTIC PLASTIC TAILPIECE TAILPIECE P TRAP FINISHED FINISHED WALL HALF WALL M968865 Rev 1 2
6. lockwise onto the Drain Body Connection 2 and hand tighten Fig A STOPPER REMOVAL PROCEDURE Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam and Cam Cap in the illustration Fig B Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain Fig D Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal Fig E The Stopper can now be removed by lifting it out of the Drain Fig F cam M968865 Rev 1 2 STOPPER INSTALLATION PROCEDURE The Stopper can be installed two ways Locked Mode Stopper cannot be removed or Unlock Mode Stopper is removable Locked Mode Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig G To install the stopper in Locked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the rear of the Sink and the American Standard logo is facing front Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig G Re install the Cam into the Drain rotating the Cam if necessary to make sure it is fully inserted Fig J Re install the Cam Cap making sure the guide teeth are facing outward If the Cam Gap does not snap int
7. o place then rotate the Cam to make sure tt is fully inserted Fig K Re attach Cable See CABLE ADJUSTMENT PROCEDURE in Troubling Shooting Guide to complete installation Stopper will be Locked Mode in Locked mode and not be removable Vandal Proof Unlocked Mode Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink and the American Standard logo is facing rear Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig H Re install the Cam into the Drain rotating the Cam if necessary to make sure it is fully inserted Fig J Re install the Cam Cap making sure the guide teeth are facing outward If the Cam Cap does not snap into place then rotate the Cam to make sure tt is fully inserted Fig K Re attach Cable See CABLE ADJUSTMENT PROCEDURE in Troublingshooting Guide to complete installation Stopper will be Unlocked Mode in Unlocked mode and removable INSTALL CAM CAP M968865 Rev 1 2 TIPS FOR REMOVING YOUR OLD DRAIN Most existing drains can be removed quickly and easily with only a pair of channel lock pliers or a wrench However there may be situations where it is difficult to remove your old drain or determine how the drain is disa
8. ssembled Depending upon the existing Drain in your sink it is either removed from above or below the sink The illustrations below show some typical drain installations and how they are disassembled from the sink The following tips can help with some of the more common challenges in drain removal m Loosen nuts on P Trap using channel locks Suggest spraying nuts with spray lubricant to loosen any corrosion or debris that may have built up Remove P Trap half from Tailpiece Use bucket to catch any residual water in P trap E Unthread Pivot Rod Nut from Drain Body and remove Pull Stopper out from Drain Body For Drains that are removed from below Sink mw Loosen Mounting Nut as far down as it will go Push Drain Body up into Sink and unthread Flange from Drain Body Remove Drain Body from below sink For Drains that are removed from above Sink Em Unthread Tailpiece from Drain Body E Loosen and remove Mounting Nut and Gasket on Drain Body using channel locks Suggest spraying nut with spray lubricant to loosen any corrosion or debris that may have built up Push Drain Body up into the Sink and remove Note If Drain body rotates while loosening Mounting Nut insert a screw driver into overflow hole to prevent Drain Body from rotating while Mounting Nut is removed Required tools Channel Locks Adjustable Wrench Phillips Screwdriver WHEN DRAIN IS REMOVED WHEN DRAIN IS REMOVED FROM ABOVE SINK FROM BE
Download Pdf Manuals
Related Search
Related Contents
ENGLISH Thank you for purchasing an Escali Digital Scale Sony MDX-C7400X User's Manual Full Application User Manual Manual de instrucciones apoya cabeza I2I 介護保険で福祉用具を 借りる・買う 介護保険で福祉用具を 借りる INSTRUCTION & SERVICE MANUAL Copyright © All rights reserved.
Failed to retrieve file