Home

American Standard 2742.XXXW User's Manual

image

Contents

1. 90 Lbs 313 Kg 69 Gal 261 L 60 Gal 227 L 41 x 21 1 2 In 1041 x 546mm 62 x 31 1 2 In 1574 x 800mm 14 1 4 In 362mm 33 Lbs Sq Ft 163 Kgs Sq m 27 8 55 7 2 1 HP 14 4 AMPS 120V THANK YOU for selecting an American Standard bath Your new bath is shipped to you after careful inspection The whirlpool version is completely assembled with pump motor and system piping All you need to finish the installation are your selected fittings and electrical connections for a whirlpool To insure maximum performance and pleasure from this product please follow the instructions and cautions List of Optional Components not included e Safe T Heater 9075 120 List of Required Components not included e Drain 1594 170 e Bath Filler List of Required Tools and Supplies Tools Supplies e Level e Nails e Tape Measure e Putty e Pipe Wrench e Caulking waterproof e Slip Joint Pliers e 1x3orr 2x2 e Screw Driver Stringers e Standard e Drop Cloth Woodworking Tools e Personal Safety Equipment e Caulking Gun GENERAL INSTALLATION INFORMATION Carefully uncrate and inspect your new bath for any shipping damage If such damage is found report it to your vendor immediately 20 amp GFI Outlet Cement Plaster Grout After inspection and during installation protect the bath from construction damage After installation and before enclosing with wallboard tile etc water test the unit an
2. ADEMARK OF PROCTER amp GAMBLE
3. TOWN SQUARE 6 X 42 HIGH GLOSS ACRYLIC SHOWN LESS ALL FITTINGS 2742 XXXW SERIES vrien Standard WHIRLPOOL BATHING POOL INSTALLATION INSTRUCTIONS i 71 1 2 1816mm la 35 3 4 gt 908mm C L OF DRAIN OUTLET INTEGRAL FITTING DECK 4 102mm 13 1 4 _ 337mm 2 1 4 X 14 a 57 X 356mm F y 41 3 4 FLOOR CUTOUT 1060mm 5 X 15 127 X 381mm 3 4 19mm L EDGE OF FLOOR CUTOUT PROVIDE ACCESS TO PUMP FOR SERVICE ON ALL INSTALLATIONS PUMP ON OFF SWITCH OUTLINE OF SKID RESISTANT SAFE T SURFACE HEATER REMOVABLE BLANK E LEVELING STRINGER PUMP NOT FOR SUPPORT OUTLINE OF CUTOUT 70 X 40 1 4 1778 X 1022mm C L OF OVERFLOW INTEGRAL FEET SUPPORT 1 1 2 N P T THREADS 1 1 2 O D TAILPIECE GENERAL SPECIFICATIONS FOR 2742 WHIRLPOOL INSTALLED SIZE WEIGHT WEIGHT w WATER GAL TO OVERFLOW WHIRLPOOL MIN OPERATING VOL BATHING WELL AT SUMP BATHING WELL AT RIM WATER DEPTH TO OVERFLOW FLOOR LOADING PROJECTED AREA PTS CUBE FT WHIRLPOOL ELECTRICAL SPECIFICATIONS WHIRLPOOL PUMP 71 1 2 x 41 3 4 x 22 In 1816 x 1060 x 559mm 115 Lbs 52 Kg 6
4. bove the top of the highest jet Recheck the pump couplings and make certain that they are not leaking Although the pump couplings are factory tightened and inspected some loosening may have occurred during transit Make sure the whirlpool is connected to the electrical supply and turn the whirlpool on Check for leaks around all piping connections while the whirlpool is running POST INSTALLATION CLEAN UP Remove all construction debris from bath Tile grout can be removed with a wooden popsicle stick or tongue depressor Do not use wire brushes or any other metal implement on bath surface Post installation clean up generally can be completed using warm water and liquid dishwashing detergent Stubborn dirt or stains may be removed using granular Spic and Span mixed with water Painter s naphtha can be used to remove excess adhesives and or wet oil base paint FEATURES of YOUR NEW AMERICAN STANDARD ACRYLIC BATHTUB Your new acrylic bathtub has been molded in the newest plumbing fixture material available today Acrylics are tough durable finishes that are simple and easy to care for The colors have been formulated to match other American Standard fixtures and enhance your choice of bathroom decorations The high gloss surface is resistant to impact and chemicals and will retain its lasting luster with proper care and maintenance AFTERCARE and CLEANING e Always fill the tub with temperate water Excessively hot water may cause surface da
5. d check for leaks Do not make modifications to the whirlpool system or remove pump from factory mounting This could adversely affect the safety and performance of the whirlpool and void the warranty Do not handle or move the whirlpool by the pump motor or piping system Fittings bath filler shower arm etc are not provided with the bath and must be ordered separately Framing and enclosing materials are provided by others Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth WARNING Do not lift whirlpool by the piping harness at any time FOR AFTER SALES SERVICE CALL 1 800 442 1902 WEEKDAYS 753027 100 REV E American Standard Inc 2007 All product names listed herein are trademarks of American Standard Inc unless otherwise noted INSTALLATION AND FRAMING INSTRUCTIONS The variety of installations possible for this whirlpool may require framing procedures other than those shown Locate studs as required Ensure roughing in dimensions are proper plumb and square Provisions must be made in all installations for an access opening for servicing the pump and controls It is strongly recommended that an additional opening be provided for access to the drain components 1 Position the whirlpool into the installation opening and level the deck shimming the integral support feet as necessary 2 Install drain components to the whirlpool following the manufacturer
6. from the pump body and heater if equipped The air massage version should be installed on a 120 vac 15 amp dedicated circuit The whirlpool version should be installed on a 120 vac 20 amp dedicated circuit The combination system requires a 120 vac 20 amp dedicated circuit for the whirlpool pump and a 120 vac 15 amp dedicated circuit for the air pump Each circuit must be a three 3 wire circuit from the electrical supply panel A grounded neutral wire and a third wire earth ground are essential ADDING THE SAFE T HEATER REQUIRES A SEPARATE 15 AMP MAXIMUM GFCI CIRCUIT ELECTRICAL INSTALLATION FOR AIR MASSAGE SEPARATE 15 AMP GFCI OUTLET FOR WHIRLPOOL SEPARATE 20 AMP GFCI OUTLET FOR COMBINATION SYSTEMS SEPARATE 15 AMP GFCI OUTLET AIR PUMP AND A SEPARATE 20 AMP GFCI OUTLET WHIRLPOOL PUMP WHIRLPOOL MOUNTED 120 VAC AIR SWITCH OR WALL TIMER ELECTRICAL DIAGRAM READ AND FOLLOW ALL INSTRUCTIONS 753027 100 REV E 3 WIRE SELECTION GUIDE Maximum distance from fusebox to motor The sizes shown on this chart are recommendations Motor for copper conductors Hi Performance only Always follow Paring 120V Power Line local and akini 2 1 10 8 electrical codes DRAIN CONNECTION AND SYSTEM TEST Using recommended drain opening connect whirlpool drain to waste line Tighten all drain joints securely Check the pump couplings and make sure they are hand tight Clean the whirlpool and fill with water to a point 2 a
7. mage e Remove bath mat after use and hang to dry Allowing bath mat to dry in the tub may cause surface damage e Clean after use with a mild liquid household detergent cleaner Do not use _ Lestoil Lysol Disinfectant spray or concentrate or Lysol Basin Tub and Tile Cleaner Windex Mr Clean Dow Disinfectant Bathroom Cleaner or cleaning products in aerosol cans HARSH CHEMICALS SHOULD NEVER BE USED ON ACRYLIC SURFACES e Do not use wire brushes knives or sharp objects to remove stains cigarette tar deposits or other surface blemishes e Abrasive cleaners or powders must not be used since they will dull the surface If the glossy surface looses its sheen dulled areas can be restored by rubbing with a white automotive type polishing compound and waxing with a liquid wax e Do not wax areas where you walk or stand Do not allow nail polish remover acetone dry cleaning fluid paint remover or other solvents to come into contact with the surface Clean the surrounding surface immediately after using caustic drain cleaners Burning cigarettes will damage the surface Should damage to the fixture occur repairs can be made quickly and easily Your distributor or builder can provide details For Air Massage and Combination systems please refer to the Installation and Operating Manual for Air Massage and Combination Systems P N 753036 100 for additional information 753027 100 REV E 4 SPIC AND SPAN IS A REGISTERED TR
8. s instructions Before replacing your whirlpool for final installation be certain that an opening has been provided in the sub floor for the drain See the roughing in drawing for suggested opening size and location dimensions 3 Replace whirlpool and re shim the integral support feet shimming the entire length of the support feet Secure the shims using construction adhesive silicone mortar or equivalent materials While not a necessity the use of a foundation base consisting of cement e g Sakrete mortar or grout will help provide a solid and secure installation TYPICAL PIER TYPE INSTALLATION AS DESIRED ae 1022mm 40 1 4 DESIRED LEVELING SURFACE WATERPROOF SEALANT ACCESS PANEL BATH a UNLESS AN ACCESS OPENING OF AT LEAST 12 X 24 305 X 610MM IS PROVIDED WARRANTY SERVICE WILL NOT BE PERFORMED 753027 100 REV E 2 ELECTRICAL INSTALLATION INSTRUCTIONS All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes WARNING When using electrical products basic precautions should always be observed including the following 1 DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a ground fault circuit interrupter 2 Grounding is required The unit should be installed by a licensed electrician and grounded 3 Install to permit access for servicing 4 All building materials and wiring should be routed away

Download Pdf Manuals

image

Related Search

Related Contents

  Service Service Service  

Copyright © All rights reserved.
Failed to retrieve file