American Standard SELECTRONIC Hard-Wired AC Powered ICU Lavatory Proximity Faucet 6059.193 User's Manual
Contents
1. SELECTRONIC Hard Wired AC Powered ICU Lavatory Proximity Faucet PRODUCT NUMBER L 7 J Product No s amp Options 1 Installation Instructions Specifications 2 How to install 2 3 i Electrical Hook up 4 5 6059 193 ICU Faucet shown Installed on American Standard 9118 111 ICU Sink Maintenance 6 7 FAQ s 8 Certified to comply with ASME A112 18 1M Replacement Parts 9 2012 American Standard M965271 American Standard NOTE TO INSTALLER Please give this manual to the customer after installation To learn more about American Standard Faucets visit our website at www us amstd com or U S customer s e mail us at faucetsupport amstd com For Parts Service Warranty or other Assistance please call 1 800 442 1902 In Canada 1 800 387 0369 In Toronto Area only 1 905 3061093 Thank you for selecting American Standard the benchmark of fine quality for over 100 years To ensure that your installation proceeds smoothly please read these instructions carefully before you begin U N PAC KI N G All American Standard Faucets Are Water Tested At Our Factory Some Residual Water May Remain In The Faucet During Shipping 1 Remove the fitting and loose items from the carton The illustration below shows the fitting and all loose items after they have been removed from the carton Some items may be packaged partially assembled to other items 1 Selectronic Spout Assembly 7 Circuit board 2 Mounti
2. slowly place your hand 1 2 in 80 50mm in front of the sensor Fig 2a 3 When the LED stops blinking and stays ON move your hand to the desired position and hold in place until the LED begins to blink again Fig 2a 4 Once the SENSOR CONTROL LED 2 begins to blink again remove your hand from the detection zone When the flashing stops the detection distance is set Fig 2a A HAND WASH SENSOR OPERATION When the Sensor detects a user the water immediately starts to flow Water flow will stop Two seconds after user is out of sensor range The off delay allows the user to comfortably move his hands without the flow cycling on to off As a precaution a safety timer will turn off the water after the sensor has been blocked for 59 seconds The water will stay off until the blockage is removed from the detection zone ki HOW TO CLEAN FILTER Fig 3 Before opening ENCLOSURE disconnect AC power supply 1 Remove ENCLOSURE COVER 2 Close SUPPLY STOP 5 with 4mm Hex wrench Note Keep water flowing out of faucet while shutting off 3 Pull off Red 1 and Black 2 CONNECTORS from SOLENOID VALVE 3 4 Unthread STRAINER 4 using a 7 16 socket 5 Pull out the STRAINER 4 and clean with an old toothbrush Rinse thoroughly with water 6 Install the STRAINER 4 back in its place and tighten with a 7 16 socket Caution do not over tighten strainer Note It is recommended to clean strainer every 6 mont
3. Q What is the normal operating pressure range A Faucet will operate with supply pressures ranging Q There is no flow out of faucet when I m in the from 20 80 psi sensor range A Check sensor If sensor blinks 2 times interrupted by pause replace battery or call 1800 442 1902 M965271
4. directly to wall supply Connection on FLEXIBLE SUPPLY 3 is 3 8 compression Use adjustable wrench to tighten connection Do not over tighten Fig 4a Note FLEXIBLE SUPPLY 3 measures 20 from the bottom of the ENCLOSURE 1 base If additional supply length is required installer must purchase parts separately Important lf FLEXIBLE SUPPLY 3 is too long loop to avoid kinking ENCLOSURE MOUNTING HOLES Ie 2 3 4 71mm MOUNTING BRACKET NOTE If using Mixing Valve optional See Sheet M968808 for installation instructions 4 Fig 4a OTHER SINK INSTALLATION 4 ELECTRICAL BOX OR EQUIVALENT BY OTHERS COLD WATER OR TEMPERED WALL SUPPLY M965271 ELECTRICAL INSTALLATION fi ELECTRICAL CONNECTIONS Fig 1 e the ener a 1 Remove ENCLOSURE COVER 1 Fig 1 2 Feed the WIRE CONNECTORS 2 through the top of ENCLOSURE 5 Fig 1a 3 Remove GROMMET 4 from ENCLOSURE 5 Fig 1 4 Feed the gray SENSOR WIRE 7 through GROMMET 4 4 from CONNECTOR Fig 1b Insert gray SENSOR WIRE 7 into SPLIT PLUG 9 Push SPLIT PLUG 9 into GROMMET 4 to seal Fig 1d 5 Insert GROMMET 4 back into ENCLOSURE 5 Fig 1c 6 Install CIRCUIT BOARD 3 into ENCLOSURE 5 with SENSOR WIRE 7 under BOARD Fig 1c 7 Insert SENSOR WIRE CONNECTOR 8 and EXTENSION WIRE CONNECTOR 11 into available CIRCUIT BOARD RECEPTORS 10 slots Fig 1e 8 Connect wires from SENSOR to
5. 0 ft EXTENSION into lower receptor as shown in fig 3 on CIRCUIT BOARD 6 of Unit 2 8 Feed gray sensor wire 9 from Unit 2 through upper U GROMMET 10 of Unit 2 ENCLOSURE 4 from connector Fig 3 Insert wire into SPLIT PLUG 7 Push SPLIT PLUG 7 into GROMMET 8 to seal Fig 3a 9 Insert GROMMET 2 back into ENCLOSURE Fig 3b 10 Reinstall Circuit Board 3 into Enclosure with all wires under Board Fig 3b 11 Connect Unit 2 Red and Black Sensor wires To 2 solenoid valve Red to Black to Fig 3b 12 Repeat Steps 3 through 11 for remaining Units in Multi Hook up Unit 3 Fig 3a TWO PIECE GROMMET 8 Wii i M Feed the gray 8 ft EXTENSION 2 through ROUND GROMMETS 3 and U GROMMETS 5 as illustrated above Fig 3b M965271 TEST INSTALLED FAUCET TO ENSURE A LAMINAR WATER FLOW the air must be slowly purged from the spout To do so cover the SENSOR 1 while slowly opening the water supply valves When the water flows as a solid smooth steady stream uncover the SENSOR 1 and fully open the water supply valve Fig 1 MAINTENANCE I HOW TO CHANGE SENSOR RANGE Factory set at 6 Fig 2 1 Setting the Detection Zone Distance Fig 1 Detection Zone 2 10 50mm 250mm Default Set at Factory 6 150mm Remove cover from ENCLOSURE Disconnect GRAY SENSOR WIRE 1 from circuit board then reconnect Fig 2 2 While the SENSOR CONTROL LED 2 is blinking
6. NUT 6 onto threads of SPOUT SHANK 3 from underside of mounting surface Fig 1a 3 Align FAUCET and tighten LOCKNUT 6 Fig 1a Note 4 and 8 Deck Plates are available for other installations see page one for information MOUNTING SURFACE Roughing in Dimensions GENERAL DESCRIPTION Electronic faucet with proximity operation Vandal resistant solid brass construction single post mounting Operates on AC permanent power In line strainer for solenoid is integral Single inlet 3 8 compression built in checks and flexible stainless steel 16 1 4 reach inlet hose for spout connection Note All plumbing and electrical wiring must be installed in accordance with applicable codes regulations and standards M965271 H MOUNT ENCLOSURE Fig 2 NOTE The illustration shows the ICU FAUCET mounted on the American Standard ICU Sink Faucet can be installed on almost any sink or countertop For Faucet installation on the American Standard ICU Sink see instruction sheet No 7301793 100 ICU Sink System supplied with Sink for more detailed information 1 For installation on ICU Sink mount ENCLOSURE 1 on MOUNTING BRACKET 2 with SCREWS 3 2 For all other sinks or countertops determine location of ENCLOSURE 1 It must be located within the 14 356mm by 21 533mm shaded area shown in Figure 2 in order for electrical connections from the spout assembly to be completed NOTE ENCLOSURE SUPPLY HOSE is 20 Dist
7. SOLENOID VALVE 6 Red to Black to Fig 1d 9 Replace ENCLOSURE COVER 1 Tighten cover screws firmly 10 Contractor to supply ELECTRICAL BOX 12 and connection to ENCLOSURE 5 Mount POWER SUPPLY 13 into ELECTRICAL BOX 12 Connect White and Black power connections to POWER SUPPLY CABLE 14 Fig 1f 11 Connect the EXTENSION WIRE 16 to the POWER SUPPLY CABLE 15 FIG 1f 4 ELECTRICAL BOX OR EQUIVALENT BY OTHERS BLACK amp WHITE O POWER CONNECTIONS eae INSTALLATION M965271 Fig 2 Unit 1 Unit 2 4 TWO PIECE GROMMET OE a i 7 e P H FOR AC VERSION MULTI HOOK UP Fig 2 3 1 See AC Version Electrical Hook up for first unit of the Multi hook up 2 Remove ENCLOSURE COVERS from all ENCLOSURES 3 Remove SOLID BLACK INSERT 1 from right side of ENCLOSURE 1 and replace with gray 2 PIECE GROMMET 3 Replace solid black inserts on Unit 2 with gray 2 PIECE GROMMET 3 4 Take the 10 ft EXTENSION 2 from Unit 2 and install into right side of Unit 1 and Left side of Unit 2 insealing wire into SPLIT PLUG 7 as shown in Fig 3a Push SPLIT PLUG 7 into GROMMET 8 5 Insert CONNECTOR from 10 ft EXTENSION 2 into CIRCUIT BOARD RECEPTOR 4 top of Unit 1 as shown in Fig 2 6 Insert other end of 10 ft EXTENSION into LOWER U GROMMET 5 of Unit 2 approximately 4 from connector Fig 3 Push SPLIT PLUG 7 into GROMMET 8 to seal 7 Insert connector of 1
8. ance between wall supply and ENCLOSURE 1 must be taken into consideration 3 Remove 4 screws from COVER 6 and pull off COVER 6 Hold the ENCLOSURE 1 in desired location and mark the four mounting hole locations as shown Fig 2 4 The ENCLOSURE 1 works best if secured to a wall stud or cross brace within the wall using the SCREWS 4 supplied If the ENCLOSURE 1 is to be installed on a tile or plaster wall the ANCHORS 5 and SCREWS 4 should be used Fig 2 5 For installations on drywall or tiled walls use ANCHORS 5 and SCREWS 4 for securing ENCLOSURE 1 to finished wall Drill four 1 4 dia holes a minimum of 1 3 4 deep Insert the four ANCHORS 5 flush with face of the finished wall Align the ENCLOSURE 1 and Install the MOUNTING SCREWS 4 Tighten to secure ENCLOSURE 1 to mounting surface E CONNECT SPOUT HOSE TO ENCLOSURE Fig 3 1 Connect SUPPLY NUT 1 from spout assembly to nipple on top of ENCLOSURE 2 Tighten with adjustable wrench to make a water tight connection Fig 3 Ei CONNECT WATER SUPPLY TO ENCLOSURE AND WALL SUPPLY Fig 4 NOTE If using the optional Mixing Valve See Sheet M968808 for installation instructions 1 Insert FIBER WASHER 4 into SUPPLY NUT 1 on ENCLOSURE 2 2 Connect SUPPLY NUT 1 on ENCLOSURE 2 to FLEXIBLE SUPPLY HOSE 3 Tighten to make a water tight connection Use two wrenches to tighten if necessary Fig 4 3 Connect FLEXIBLE SUPPLY 3
9. hs 7 Replace ENCLOSURE COVER Tighten cover screws firmly 250mm CLEAN SCREENS M965271 Ef HOW TO CLEAN AND REMOVE THE FLOW RESTRICTOR Fig 4 1 Remove SET SCREW 1 with FLAT BLADE SCREWDRIVER 2 Pull off SPOUT 3 from faucet base Fig 4 amp 4a 2 Remove HOUSING 4 and remove FLOW RESTRICTOR 5 Fig 4b 3 Rinse clean FLOW RESTRICTOR 5 Reassemble and install into SPOUT BASE 6 Reassemble SPOUT 3 onto SPOUT BASE 6 and tighten SET SCREW 1 Fig 4 PULL UPTO REMOVE SPOUT fa GENERAL CLEANING Fig 5 1 For general cleaning use a damp soft cloth to clean the spout and the sensor 2 For cleaning dirt use a soft cloth with diluted dish washing detergent Wipe the area using a wet cloth and dry using a soft cloth Do not scratch the sensor when cleaning Avoid using anything that may scratch the spout surface Never use polishing power detergent or a nylon scrub brush They will damage the surface of the spout or Sensor M965271 Q How will know if battery needs to be replaced Q Why does the faucet operate the opposite of A Valve does not open and sensor blinks 2 times expected Turns On when not in sensor range but turns interrupted by pause for up to 7 days off when in sensor range A Sensor wires to solenoid are reversed Black to Q Why has the flow rate of the faucet reduced amp Red to is correct significantly A Check and clean aerator and strainer
10. ng Kit 8 4 Deck plate optional must be ordered separately 3 Electrical Enclosure 9 8 Deck plate optional must be ordered separately 4 Supply Hose 10 Mixing Valve optional must be ordered separately 5 10 ft Extension Wire 11 Installation Instructions 6 Power Supply PRODUCT No s 6059 193 SELECTRONIC Hard Wired AC Powered ICU Lavatory Proximity Faucet PRODUCT NUMBER DO NOT REMOVE PROTECTIVE FILM FROM SENSOR EYE UNTIL INSTALLATION IS COMPLETE Product No s amp Options G fe 4 S D Bo p G G fe 4 iy G cus For Parts Service Warranty or other Assistance please call 1 800 442 1902 In Canada 1 800 387 0369 In Toronto Area only 1 905 3061093 605P400 605P800 eld 499q 605XTMV oAleA Bu xi M965271 FINISHED WALL J 127mm 5 an i i 133mm 2 1 8 DIA 5 1 4 semm 60mm 2 3 8 MAX 1 1 4 DIA 16 1 4 ELECTRICAL BOX OR EQUIVALENT BY OTHERS lt i 3 8 COMP RECOMMENDED TOOLS 1 Channel Locks 2 Adjustable Wrench 3 Plumbers Putty or Caulking 4 Phillips Screwdriver 5 Flat Blade Screwdriver 6 Electric Drill amp 1 4 Drill Bit 7 Tape Measure INSTALLATION fl INSTALL SPOUT ASSEMBLY Fig 1 esk e eane 1 Insert WIRES 1 FLEX HOSE 2 and SPOUT SHANK 3 through center hole of mounting surface Fig 1 2 Assemble C WASHER 4 STAR WASHER 5 and LOCK