1. connected to the electrical supply and turn the whirlpool on Check for leaks around all piping connections while the whirlpool is running POST INSTALLATION CLEAN UP Remove all construction debris from bath Tile grout can be removed with a wooden popsicle stick or tongue depressor Do not use wire brushes or any other metal implement on bath surface Post installation clean up generally can be completed using warm water and liquid dishwashing detergent Stubborn dirt or stains may be removed using granular Spic and Span mixed with water Painter s naphtha can be used to remove excess adhesives and or wet oil base paint HARSH CHEMICALS SHOULD NEVER BE USED ON ACRYLIC SURFACES Abrasive cleaners must not be used since they will scratch and dull the surface Dulled areas can be restored by rubbing with a white automotive type polishing compound and waxing with a liquid wax 752460 100 REV E 4 SPIC AND SPAN IS A REGISTERED TRADEMARK OF PROCTER amp GAMBLE
2. in the sub floor for the drain See the roughing in drawing for suggested opening size and location dimensions 3 Replace whirlpool and re shim the integral support feet shimming the entire length of the support feet Secure the shims using construction adhesive silicone mortar or equivalent materials While not a necessity the use of a foundation base consisting of cement e g Sakrete mortar or grout will help provide a solid and secure installation TYPICAL CORNER INSTALLATION 56 3 4 Ein 56 3 4 1441 mm 1441 mm LEVELING SURFACE WATERPROOF SEALANT BATH HEIGHT OF FRAMEWORK INCLUDES PLYWOOD SUNKEN OR ISLAND TILES ETC INSTALLATION FRONT OR SIDE ACCESS PANEL REQUIRED FOR SEE CUTOUT TEMPLATE PROVIDED Oe Seen UNLESS AN ACCESS OPENING OF AT LEAST 12 X 24 305 X 610MM IS PROVIDED WARRANTY SERVICE WILL NOT BE PERFORMED 752460 100 REV E 2 SPIC AND SPAN IS A REGISTERED TRADEMARK OF PROCTER amp GAMBLE ELECTRICAL INSTALLATION INSTRUCTIONS All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes WARNING When using electrical products basic precautions should always be observed including the following 1 DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a ground fault circuit interrupter 2 Grounding is required The unit should be installed by a licensed electrician and grounde
3. SAVONA CORNER HIGH GLOSS ACRYLIC SHOWN LESS ALL FITTINGS 2902 XXXW Aimtricam Standard SERIES WHIRLPOOL INSTALLATION INSTRUCTIONS TO PUMP FOR PROVIDE ACCESS SERVICING ON ALL 42 INSTALLATIONS SAFE T HEATER REMOVABLE BLANK ON OFF SWITCH 69 1 2 1067 mm 1765 mm RECOMMENDED FITTING LOCATIONS 64 X 330mm 2 1 2 X 13 CUTOUT IN FLOOR DRAIN OUTLINE OF CUTOUT 1048mm EEn 1 1 2 O D DRAIN OUTLET 41 1 4 2096mm 82 1 2 atin C L OF pon 2 STRINGER Siin NOT FOR SUPPORT Lo INTEGRAL 1 3 4 FEET ASA en 3 1 2 1 1 2 O D TAILPIECE ROUGH FLOOR 1 1 2 N P T M THREADS 20 1 2 WEIGHT WEIGHT w WATER GAL TO OVERFLOW BATHING WELL AT SUMP BATHING WELL AT RIM WATER DEPTH TO OVERFLOW FLOOR LOADING WHIRLPOOL MIN OPERATING VOL PROJECTED AREA PTS 58 x 55 In 1473 x 1397mm 15 3 4 In 400mm GENERAL SPECIFICATIONS FOR 2902 WHIRLPOOL INSTALLED SIZE ___ 82 1 2 x 69 1 2 x 22 1 2 In 2096 x 1765 x 572mm 144 Lbs 65 Kg 803 Lbs 361 Kg 79 Gal 299 L 73 Gal 277 L 38 x 30 In 965 x 762mm 33 Lbs Sq Ft 165 Kgs Sq m 41 7 CUBE FT 68 4 SYSTEM II PUMP WHIRLPOOL ELECTRICAL SPECIFICATIONS 2 1 HP 15 6 AMPS 120V GENERAL INSTALLATION INFORMATION Carefully uncrate and inspect your ne
4. d 3 Install to permit access for servicing 4 All building materials and wiring should be routed away from the pump body and heater if equipped The whirlpool should be installed on a 120 vac 20 amp dedicated circuit The circuit should be hard wired from the electrical power supply panel The circuit must be a three 3 wire circuit from the electrical supply panel A grounded neutral wire and a third wire earth ground are essential ADDING THE SAFE T HEATER REQUIRES A SEPARATE 15 AMP MAXIMUM GFCI CIRCUIT ELECTRICAL INSTALLATION SEPARATE 20 AMP GFCI OUTLET WHIRLPOOL MOUNTED 120 VAC ELECTRONIC SWITCH ELECTRICAL DIAGRAM READ AND FOLLOW ALL INSTRUCTIONS 752460 100 REV E 3 WIRE SELECTION GUIDE Maximum distance from fusebox to motor The sizes shown on this chart are recommendations for copper conductors only Always follow local and national Motor Hi Performance Rating 120V Power Line 2 1 10 8 electrical codes DRAIN CONNECTION AND SYSTEM TEST Using recommended drain opening connect whirlpool drain to waste line Tighten all drain joints securely Check the pump couplings and make sure they are hand tight Clean the whirlpool and fill with water to a point 2 above the top of the highest jet Recheck the pump couplings and make certain that they are not leaking Although the pump couplings are factory tightened and inspected some loosening may have occured during transit Make sure the whirlpool is
5. r move the whirlpool by the pump motor or piping system Fittings bath filler shower arm etc are not provided with the bath and must be ordered separately Framing and enclosing materials are provided by others Check for availability of optional American Standard wall tiling bead required for recess installations Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth WARNING Do not lift whirlpool by the piping harness at any time FOR AFTER SALES SERVICE CALL 1 800 442 1902 WEEKDAYS 752460 100 REV E American Standard Inc 2003 All product names listed herein are trademarks of American Standard Inc unless otherwise noted INSTALLATION AND FRAMING INSTRUCTIONS The variety of installations possible for this whirlpool may require framing procedures other than those shown Locate studs as required Ensure roughing in dimensions are proper plumb and square Provisions must be made in all installations for an access opening for servicing the pump and controls It is strongly recommended that an additional opening be provided for access to the drain components 1 Position the whirlpool into the installation opening and level the deck shimming the integral support feet as necessary 2 Install drain components to the whirlpool following the manufacturers instructions Before replacing your whirlpool for final installation be certain that an opening has been provided
6. w bath for any shipping damage If such damage is found report it to your vendor immediately THANK YOU for selecting an American Standard bath Your new bath is shipped to you after careful inspection The whirlpool version is completely assembled with pump motor and system piping All you need to finish the installation are your selected fittings and electrical connections for a whirlpool To insure maximum performance and pleasure from this product please follow the instructions and cautions List of Optional Components not included e SafeT Heater 9075 120 e Tile Bead Kit 751755 100 List of Required Components not included e Drain 1583 470 e Bath Filler see your American Standard Distributor List of Required Tools and Supplies Tools Supplies e Level e Nails e Tape Measure e Putty e Pipe Wrench e Caulking waterproof e Slip Joint Pliers e1x3or2xe2 e Screw Driver Stringers e Standard e Drop Cloth Woodworking Tools e 20 amp GFI e Personal Safety Outlet Equipment e Caulking Gun Cement Plaster Grout After inspection and during installation protect the bath from construction damage After installation and before enclosing with wallboard tile etc water test the unit and check for leaks Do not make modifications to the whirlpool system or remove pump from factory mounting This could adversely affect the safety and performance of the whirlpool and void the warranty Do not handle o