1. from the chart below and use the appropriate assembly parts required to properly reconnect the water supply DO NOT use plumber s putty to seal these fittings METAL COPPER METAL FLANGED FLARED TUBING TUBING E LOCK NUT N LOCK NUT CONE gt EXISTING 7 WASHER WASHER COUPLING _ EXISTING NUT COUPLING NUT l WATER WATER Z SHUT OFF SHUT OFF p These parts must be used as Use existing illustrated to insure water tight coupling nut connection Use of existing and washer coupling nut may result in water leakage Water supply tube or pipe must extend at least 1 2 inside threaded shank of valve does not apply to flanged tubing CAUTION DO NOT USE CONE WASHER WITH PLASTIC SUPPLY LINE METAL SPIRAL VINYL BRAIDED TUBING CONNECTOR N LOCK NUT SPS tock NUT EXISTING COUPLING J CONE LI Nor WASHER COUPLING J NUT WATER XIN WATER SHUT OFF SB SHUT OFF i 7 Use existing spiral Captive cone cone washer washers already Fluidmaster cone included No washer may not additional washers seal completely on needed spiral type supply line D gt CAUTION Overtightening of LOCK NUT or COUPLING NUT could result in breakage and potential flooding With correct washers in place see Step 8a tighten COUPLING NUT 1 4 turn beyond hand tight DO NOT OVERTIGHTEN 730449 100 Rev C NIPPLE TUBE ADJUSTMENTS a Adjust water level Water level La should be adj
2. place of installation if it has been subjected to faulty maintenance abuse misuse accident or other damage if it was not installed in accordance with American Standard s instructions or if it has been modified in a manner inconsistent with the product as shipped by American Standard American Standard s option to repair or exchange the product under this warranty does not cover any labor or other costs of removal or installation nor shall American Standard be responsible for any other incidental or consequential damages attributable to a product defect or to the repair or exchange of a defective product all of which are expressly excluded from this warranty Some states or provinces do not allow the exclusion or limitation of implied warranties so this exclusion may not apply to you This warranty gives you specific legal rights You may have other statutory rights that vary from state to state or from province to province in which case this warranty does not affect such statutory rights For service under this warranty it is suggested that a claim be made through the contractor or dealer from or through whom the product was purchased or that a service request including a description of the product model and of the defect be sent to the following address In the United States In Canada In Mexico American Standard Inc American Standard Customer Service Manager P O Box 6820 2480 Stanfield Rd Ideal Standard S A de C V Piscatawa
3. 90 and slide La g poyma OR OE RANE AS REQUIRED FLOOR into place 6 152 mm apart and parallel to wall 4 102mm lt gt J WASHER SEALANT INSTALL WAX SEAL POSITION TOILET ON FLANGE Invert toilet on floor cushion to prevent damage and a Unplug floor waste opening and install toilet on closet flange so bolts project install wax ring evenly around waste flange horn with through mounting holes tapered end of ring facing toilet Apply a thin bead of b Loosely install retainer washers and nuts Side of washers marked THIS sealant around toilet base SIDE UP must face up Americam Toal Lhasa Sadosa Standard Standard Stamdard Standard Ceddea Saniwares Product names listed herein are trademarks of American Standard Inc 730449 100 Rev Cc American Standard Inc 2002 U S FUTURE R FO SAVE MTG CLIP WASHER ANANA INSTALL TOILET a Before continuing determine the type Position toilet squarely to wall and with a rocking motion press bowl down fully on wax ring and flange Alternately tighten nuts until toilet is firmly seated on floor A CAUTION DO NOT OVERTIGHTEN NUTS OR BASE MAY BE DAMAGED Install caps on washers If necessary cut bolt height to size before installing caps Smooth off the bead of sealant around base Remove excess sealant of water supply connecation you have
4. INSTALLATION HERITAGE1 6 GPF ONE PIECE TOILET INSTRUCTIONS 2071 016 Thank you for selecting American Standard the benchmark of fine quality for over 100 years To ensure this product is installed properly please read these instructions carefully before you begin Certain installations may require professional help Also be sure your installation conforms to local codes A CAUTION PRODUCT IS FRAGILE TO AVOID BREAKAGE AND POSSIBLE INJURY HANDLE WITH CARE NOTE Pictures may not exactly define contour of china and components RECOMMENDED TOOLS AND MATERIALS Putty Knife Regular Screwdriver Adjustable Wrench Sealant Tape Measure Hacksaw Wax Ring Gasket Flexible Supply Tube Closet Bolts Carpenters Level IE REMOVE OLD TOILET Close toilet supply valve and flush tank completely Towel or sponge remaining water from tank and bowl Disconnect and remove supply line NOTE f replacing valve first shut off main water supply Remove old mounting hardware remove toilet and plug floor waste opening to prevent escaping sewer gases Remove closet bolts from flange and clean away old wax putty etc from base area NOTE Mounting surface must be clean and level before new toilet is installed ROUGHING IN DIMENSIONS NOTE Distance from wall to closet flange centerline must be as listed below FINISHED WALL 19 3 4 CLOSET FLANGE 30 502mm 762mm CLOSET BOLTS 14 aes INSTALL CLOSET BOLTS la 12 z Install closet bolts in flange channel turn
5. LVE SEAT AND COVER a FLUIDMASTER ge 5 TANK COVER SS FLAPPER ASSEMBLY HERITAGE REPAIR PARTS LIST p SEAT AND COVER NOTE XXX represents color options Specify when ordering TAIP LEVER ae vA DESCRIPTION COMPONENT Tank Cover 735080 400 XXX Seat and Cover Elongated 5357 016 XXX Bolt Cap Kit 73603 1 XXXOA BOLT CAP KIT Trip Lever 730283 XXXOA Water Control Assembly 738565 0070A Flush Valve 738109 0070A Flapper Assembly 738151 0070A 3 730449 100 Rev C TROUBLESHOOTING IF FILL VALVE SHUTS OFF BUT CONTINUES TO LEAK SLOWLY repeat Step 12 IF FILL VALVE TURNS OFF AND ON DURING PERIODS OF NON USE it is a signal you are wasting water because LIFT ARM e The end of the refill tube is inserted into overflow pipe below water level in tank Attach refill tube to overflow pipe using S clip provided e The flush valve is leaking because it s worn dirty or misaligned with tank ball or flapper replace with a new flapper IF FILL VALVE WON T TURN ON OR SHUT OFF or REFILL OF TANK WATER IS SLOW after valve has been in use for IMPORTANT Always e While holding a e Replace TOP by engaging some time Fluidmaster Model 242 Replacement Seal may be clear sand and rust from container over the lugs and rotating 1 8 turn needed system uncapped VALVE to clockwise MAKE CERTAIN e Make sure water supplyis prevent splashing tun TIP IS TURNED TO THE nected EE off Remove valve
6. TOP by water supply on and off a LOCKED POSITION lifting arm and rotating top few times Leave water VALVE MAY NOT TURN For troubleshooting information please contact and arm 1 8 turn supply off ON IF TOP IS NOT FULLY counterclockwise pressing TURNED TO THE LOCKED down slightly on cap POSITION Fluidmasterlnc 30800 Rancho Viejo Road GUARANTEE This Fluidmaster product is guaranteed to be free from defective materials and San Juan Capistrano CA 92675 workmanship for a period of one year Units returned to Fluidmaster will be replaced without charge 949 728 2000 800 631 2011 www fluidmaster com Always use quality Fluidmaster repair parts when maintaining your Fluidmaster products Fluidmaster shall not be responsible or liable for any damages caused by products used with Fluidmaster valves 2001 Fluidmaster Inc that were not manufactured by Fluidmaster Inc Registered trademark of Fluidmaster Inc TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION Does not flush a Water supply valve closed a Open valve and allow water to fill tank b Supply line blocked b Shut off water supply disconnect supply line and inspect all gaskets and washers Reassemble Also see Fluidmaster maintenance see step 12 Flush valve chain too loose or disconnected 3 Readjust chain length as required Sand or debris lodged in water control j Shut off water supply Remove cap and clean per Step 12 Poor or sluggish flush Bow
7. l water level too low 7 Check that refill tube is connected to water control and inserted into tank overflow without being kinked or damaged Supply valve partly closed i Open supply valve fully Be sure that proper supply tube size is used Partially clogged trapway and or drain pipe and or vent Remove obstruction Consult a plumber if necessary Supply pressure too low Normal supply pressure must be at least 20 psi Toilet leaks Poor supply line connection k Review Step 8 of installation procedure Toilet does not shut off Flush valve chain too tight holding flush valve open Readjust chain length as needed Review step 9 Flush valve seat and or flapper worn or deformed Replace flapper flush valve assembly as needed Sand or debris lodged in water control Shut off water supply Remove cap and clean per Step 12 AMERICAN STANDARD ONE YEAR LIMITED WARRANTY If inspection of this American Standard plumbing product within one year after its initial purchase confirms that it is defective in materials or workmanship American Standard will repair or at its option exchange the product for a similar model This warranty does not apply to local building code compliance Since local building codes vary considerably the purchaser of this product should check with a local building or plumbing contractor to insure local code compliance before installation This warranty shall be void if the product has been moved from its initial
8. usted to level ORAK COL indicated on tank by adjusting float MUST BE cup 1 ABOVE OVERFLOW PIPE See Step 10 for water level adjustment method VALVE WAERLEVEL If bowl fails to siphon an adjustment ADJUSTMENT 3 may be required with the lift chain g Simply remove the bead chain from 3 the retainment clip and take up ADJUSTABLE slack on the chain and reinsert on lift FLAPPER UJ rod Make sure the chain is not too cum a taught Turn on water supply Adjust water to desired level by squeezing water level adjustment clip and E THREADED SHANK moving FLOAT CUP up or CONE WASHER SA down along stainless steel PARTS FOR WATER CONNECTION link COUPLING NUT un SEE STEP 9 HAND TIGHT ONLY 0 Diagram 1 1k E CARE AND CLEANING When cleaning your toilet wash it with mild soapy water rinse thoroughly with clear water and dry with a soft cloth Avoid detergents disinfectants or cleaning products in aerosol cans NEVER use abrasive scouring powders or abrasive pads on your toilet seat Some bathroom chemicals and cosmetics may damage the seat s finish A WARNING Do not use in tank cleaners Products containing chlorine calcium hypochlorite can seriously damage fittings in the tank This damage can cause leakage and property damage American Standard shall not be responsible or liable for any tank fitting damage caused by the use of cleaners containing chlorine calcium hypochlorite FLUSH VA
9. y New Jersey 08855 Mississauga Ontario Via Morelos 330 Attention Director of Consumer Affairs Canada L4Y 1S2 Col Santa Clara Ecatepec 55540 Edo Mexico For residents of the United States warranty information may also be Toll Free 800 387 0369 obtained by calling the following toll free number 800 442 1902 4 730449 100 Rev C