Home
American Standard Ceramix 2000.011 User's Manual
Contents
1. Armbtrican Standard CERAMIX BIDET FITTING with EverClean Finish Congratulations on purchasing your American Standard faucet with EverClean finish found only on American Standard faucets Installation Instructions 2000 011 EverClean Finish e One wipe effortlessly removes spots Eliminates the need for cleaners and scrubbing e Permanent surface protectant remains beautiful for the life of the faucet e EverClean available on Polished Chrome Satin Nickel Stainless Steel Polished Brass or any combination of these finishes Certified to comply with ASME A112 18 1M M968761 Rev 1 1 To ensure that your installation proceeds smoothly please read these instructions carefully before you begin TOOLS REQUIRED Channel Locks Adjustable Wrench Plumbers Putty or Caulking Phillips Screwdriver EverClean Finish Care Instructions American Standard s EverClean finish will wipe clean with a soft dry cloth A soft cloth with clean water may also be used if desired No additional cleaning products are required DO NOT USE Soaps acid polish abrasives harsh cleaners or a cloth with a coarse surface INSTALL FAUCET B Ml Tran cure P MAKE WATER SUPPLY CONNECTIONS For 3 hole 4 centers installation apply Putty to underside of Escutcheon optional 4 and place over holes in lavatory sink with tab towards back Feed FLEXIBLE HOSES 8 through Rubber Ring 2 and through hole in Escutcheon foptional 4 or mo
2. ack of the sink Assemble Pivot Rod 9 as shown in Figure 4B Notice the position of the Concave Washer G Insert Pivot Rod 9 into Drain Body 10 and tighten Pivot Nut F Push Tailpiece Insert 12 into Tailpiece 141 and push Tailpiece 411 up and thread tightly into Drain Body 10 Position Extension Rod 7 onto Pop Up Rod E and tighten Thumbscrew 6 Remove one end of Clip 8 from Pivot Rod 9 by squeezing ends together while sliding Insert Pivot Rod 9 into second or third hole in Extension Rod 7 and reassemble Clip 8 Drop Stopper 1 into Drain Body 10 Adjust stopper height by repositioning Extension Rod 7 and tightening Thumbscrew 6 TEST INSTALLED FITTING SERVICE FIGURE 4B With HANDLE 19 in OFF position turn on WATER If f tdri te handi Iti f SUPPLIES 2 and check all connections for leaks off to font Doter a a Com Remove AERATOR 3 Clogged CARTRIDGE inlets may cause reduced flow in full on hot Id To cl inlets first t ff Operate HANDLE 1 to flush eae meat baits o clean inlets first turn oO Remove HANDLE 1 CAP 2 and CARTRIDGE 3 Replace AERATOR 3 A fr Clean inlets and MANIFOLD 4 water lines thoroughly Operate Pop Up and fill A i Reassemble CARTRIDGE 4 alternately tightening lavatory with water SCREWS 5 Replace CAP 2 and HANDLE 1 Check that DRAIN Check flow STOPPER 4 makes a good seal and retains water in lavatory Adjust st
3. opper height by repositioning Pop Up ROD 5 and tightening THUMBSCREW 6 Release DRAIN STOPPER 4 and check all drain connections and P trap for leaks Tighten if necessary ADJUST HOT LIMIT STOP By restricting handle rotation and limiting the amount of hot water allowed to mix with the cold the HOT LIMIT TEMPERATURE SAFETY STOP reduces risk of accidental scalding To cee PETING RUMEERS set the maximum hot water temperature of your faucet T a See all you need to do is adjust the setting on the HOT LIMIT AND ROTATE CLOCKWISE SAFETY STOP B ami ADJUSTMENT WHEN Refer to step 5 to remove handle then WATER IS TOO COLD Use a flat blade screwdriver or your fingers to pull up and rotate red HOT LIMIT SAFETY STOP 1 Follow Step A or B to adjust min max discharge temperature O being the hottest to 7 the coldest temperature setting Factory set at O o MH Ca a _ i PRY RED RING FORWARD AND ROTATE COUNTER CLOCKWISE ONE CLICK ADJUSTMENT WHEN WATER IS TOO HOT RED RING HOT LIMIT SAFETY STOP M968761 Rev 1 1
4. unting E Turn off hot and cold water supplies before beginning Connect FLEXIBLE SUPPLIES 1 2 directly to wall supplies Connection on fitting supplies are 3 8 compression Connect surface Escutcheon 4 is optional on single hole lavatories Make sure Rubber Ring 2 is seated in groove in base of Faucet 1 From below push Mounting Gasket with Mounting Washer 5 over Stud 3 and secure with Nut 6 pushing Faucet 1 to back of sink so Stud 3 rests against sink hole Before final tightening adjust Faucet 1 and Escutcheon 4 so that they are centered PUTTY BIDET DECK left supply to Hot Marked with a Red Tag and right supply to Cold wall supply Use adjustable wrench to tighten connections Do not over tighten Faucet supplies are 18 long from faucet base Note If additional supply length is required installer must purchase additional parts separately Important If SUPPLY HOSES 1 2 are too long loop as illustrated to avoid kinking J NS nae cae ie e MA IZT NASA 3 8 COMPRESION INSTALL POP UP DRAIN Push Tail piece 11 down into Trap C threaded end up Thread Locknut 5 Washer 4 and Gasket 3 Bevel side up onto Drain Body 10 Apply a bead of Putty D to underside of Flange 2 Feed Drain Body 10 up through Sink A and thread the Flange 2 fully onto Drain Body 10 Tighten Locknut 5 firmly keeping the pivot rod hole pointed towards the b
Download Pdf Manuals
Related Search
Related Contents
IOTC e-PSM Application User Manual for the Port State Competent USER MANUAL MANUAL D'UTILISATEUR 取扱説明書 - 株式会社ナスタ MANUALE DEL SOFTWARE VBOXTools manual montagem geral PUHY-HP-YHM-A (-BS) Guide de l`utilisateur du HBA à double accès FC 4Gb ATCA Sun 取扱説明書 - ノースワン株式会社 Origin Storage 256GB MLC SATA 2.5" Copyright © All rights reserved.
Failed to retrieve file