1. Inc 1 800 442 1902 One Centennial Avenue Piscataway N J 08855 Attention Customer Care Center SERVICE For service or repair contact the number below The model number and serial number for your whirlpool are located on a label near the motor HOTLINE FOR HELP For toll free information and answers to your questions call 1 800 442 1902 weekdays 8 00 a m to 5 00 p m Eastern Time Product names listed herein are trademarks of American Standard Inc American Standard Inc 2003 AMERICAN STANDARD ONE YEAR LIMITED WARRANTY FOR E Z INSTALL WHIRLPOOL HEATER If inspection of this American Standard plumbing product within one year after its initial purchase confirms that it is defective in materials or workmanship American Standard will repair or at its option exchange the product for a similar model This warranty applies only to the original purchaser and installation of these products This limited warranty does not apply to local building code compliance Since local building codes vary considerably the purchaser of this product should check with a local building or plumbing contractor to insure local code compliance before installation This warranty shall be void if the product has been moved from its initial place of installation if it has been subjected to faulty maintenance abuse misuse accident or other damages if it was not installed in accordance with American Standard s instructions or if it has been modified
2. a physician before using the whirlpool Water temperatures in excess of 100 Fahrenheit are not recommended b The use of alcohol drugs or medication before or during the use of the whirlpool may lead to unconsciousness with the possibility of drowning Consult your physician before using the whirlpool if you are using any medication d Persons suffering from obesity or with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using the whirlpool 4 WARNING Risk of Child Drowning To reduce the risk of accidental drowning do not permit children to use the whirlpool unless they are closely supervised 5 WARNING RISK OF ELECTRICAL SHOCK All electrical connections must be accomplished by a qualified electrician in accordance with Article 680 of the National Electric Code and any local codes In addition a GFCI MUST protect all branch circuits to the whirlpool and every electrical component MUST be grounded 6 The unit must be connected only to a supply circuit that is protected by a ground fault circuit interrupter GFCI Such as GFCI should be provided by the installer and should be tested on a routine basis To test the GFCI push the test button The GFCI should interrupt power Push the reset button Power should be restored If the GFCI fails to operate in this manner the GFCI is defective If the GFCI interrupts power to the bathtub without the
3. and heater if equipped The whirlpool should be installed on a 120 vac 20 amp dedicated circuit The circuit should be hard wired from the electrical power supply panel The circuit must be a three 3 wire circuit from the electrical supply panel A grounded neutral wire and a third wire earth ground are essential E Z INSTALL WHIRLPOOL HEATER ELECTRICAL INSTALLATION INSTRUCTIONS aan Install a separate 120VAC 15AMP dedicated circuit with GFCI Ground Fault Circuit Interrupter protection With a No 8 solid copper wire bond the heater to the homes electrical panel or approved local bonding point A bonding lug has been provided on the heater SEPARATE TS AMPGECLOUTEET ELECTRICAL INSTALLATION At initial start up with power ON push the GFCI test button The reset button should pop out Push this button in to reset If the GFCI idee fails to operate in this manner there is a ground fault or malfunction indicating the possibility of electrical shock Turn off the power and do not use the bath until the source of the problem has been HEATER identified and corrected 1 Route two separate branch circuits figure 1 to the junction box near the whirlpool Each branch circuit MUST BE GFCI PROTECTED 2 Use copper conductors only 3 Insure the heater and pump are properly GROUNDED and BONDED as required Bonding connectors suitable for No 8 AWG copper wire are located on both the pump and heater assemblies a Us
4. safety and performance of the whirlpool and void the warranty Do not handle or move the whirlpool by the pump motor or piping system Fittings bath filler shower arm etc are not provided with the bath and must be ordered separately Framing and enclosing materials are provided by others Check for availability of optional American Standard wall tiling bead required for recess installations Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth WARNING Do not lift whirlpool by the piping harness at any time FOR AFTER SALES SERVICE CALL 1 800 442 1902 WEEKDAYS American Standard Inc 2003 752864 100 Rev C All product names listed herein are trademarks of American Standard Inc unless otherwise noted INSTALLATION AND FRAMING INSTRUCTIONS The variety of installations possible for this whirlpool may require framing procedures other than those shown Locate studs as required Ensure roughing in dimensions are proper plumb and square Provisions must be made in all installations for an access opening for servicing the pump and controls It is strongly recommended that an additional opening be provided for access to the drain components NOTE The apron should not be used as the primary access opening 1 Position the whirlpool into the installation opening and level the deck shimming the integral support feet as necessary Mark the final position of the underside of the deck
5. test button being pushed a ground current is flowing indicating the possibility of an electric shock Do not use this bathtub Disconnect the hydromassge bathtub and have the problem corrected by a qualified service representative before using 7 WARNING Prolonged immersion in hotter water may induce hyperthermia Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98 6 F The symptoms of hyperthermia include an increase in the internal temperature of the body dizziness lethargy drowsiness and fainting The effect of hyperthermia include a Failure to perceive heat b Failure to recognize the need to exit the bathtub c Unawareness of impending hazard d Fetal damage in pregnant women e Physical inability to exit the bathtub 752864 100 Rev C 3 WHIRLPOOL ELECTRICAL INSTALLATION INSTRUCTIONS All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes WARNING When using electrical products basic precautions should always be observed including the following 1 DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a ground fault circuit interrupter 2 Grounding is required The unit should be installed by a licensed electrician and grounded 3 Install to permit access for servicing 4 All building materials and wiring should be routed away from the pump body
6. with a preset pressure switch The pump must be running with water flowing in the whirlpool to allow the heater to turn on Indicator Light This light turns on whenever the heater is operating See Fig 2 High Limit Switch The heater includes an exclusive Intelligent High Limit This safety circuit will not false trip from hot tap water It will only turn the heater off if the thermostat fails To reset simply press the button If the high limit trips frequently call a service technician OVERHEAT PROTECTION HEATER ON RESET as Amiran Standard E Z INSTALL WEAKER POST INSTALLATION CLEAN UP Remove all construction debris from bath Tile grout can be removed with a wooden popsicle stick or tongue depressor Do not use wire brushes or any other metal implement on bath surface Post installation clean up generally can be completed using warm water and liquid dishwashing detergent Stubborn dirt or stains may be removed using granular Spic and Span mixed with water Painter s naphtha can be used to remove excess adhesives and or wet oil base paint HARSH CHEMICALS SHOULD NEVER BE USED ON ACRYLIC SURFACES Abrasive cleaners must not be used since they will scratch and dull the surface Dulled areas can be restored by rubbing with a white automotive type polishing compound and waxing with a liquid wax 752864 100 Rev C 5 SPIC AND SPAN Is A REGISTERED TRADEMARK OF PROCTER amp GAMBLE American Standard Limited Lifeti
7. 6060E SERIES American Standard tenaossaence WHIRLPOOL Poesia INSTALLATION INSTRUCTIONS 1949mm i 975mm es A THANK YOU A OUTLINE OF CUTOUT for selecting an American Standard bath Your new bath is shipped to you after careful inspection The whirlpool version is completely assembled with pump motor and system piping All you need to finish the installation are your selected fittings and electrical connections for a whirlpool 1661mm 65 3 8 To insure maximum performance and pleasure from this product please follow the instructions and cautions 178mm x 381mm 7 x 15 CUTOUT NOTE APRON ASSEMBLY WILL PROVIDE REQUIRED ACCESS FOR SERVICING wa ROVIDE ACCESS TO PUMP FOR SERVICE ON ALL INSTALLATIONS PI 346mm 13 5 8 a List of Optional Components not included toy RECOMMENDED FITTING ra it LOCATION 64 X 381mm 2 1 2 X 15 e Flex Jet Pulse Jet Kit Bsa e Flex Jet Soft Jet Kit e it C L OF OVERFLOW 4 1 2 seco ay T es 89mm 3 1 2 E E Z INSTALL WHIRLPOOL a pean 49am List of Required Components not included 3 1 4 eat e Drain e Bath Filler 2 546mm 21 1 2 n 173 ieee Pe see your Home Depot Retailer a SUPPORT een 1 M N P T TH
8. READ ROUGH FLOOR 1 1 2 O D TAILPIECE List of Required Tools and Supplies GENERAL SPECIFICATIONS FOR 6060E WHIRLPOOL Tools Supplies INSTALLED SIZE ___76 3 4 x 65 3 8 x 21 1 2 In 1949 x 1661 x 546mm e Level e Nails WEIGHT 105 Lbs 48 Kg e Tape Measure e Putty WEIGHT w WATER 822 Lbs 370 Kg f i GAL TO OVERFLOW 86 Gal 326 L e Pipe Wrench e Caulking waterproof WHIRLPOOL MIN OPERATING VOL _________ _ 71 Gal 269 L e Slip Joint Pliers e1x3orexe BATHING WELL AT SUMP________45 x 40 In 1143 x 1016mm e Screw Driver Stringers BATHING WELL AT RIM 49 x 43 In 1245 x 1092mm e WATER DEPTH TO OVERFLOW 15 3 8 In 391mm sv kino Tool 2 foe mag amp 20 FLOOR LOADING 24 Lbs Sq Ft 114 Kgs Sq m ooaworking 00 s amp amp PROJECTED AREA e Personal Safety GFI Outlet UDE EG ae Equipment e Cement Plaster i i WHIRLPOOL ELECTRICAL SPECIFICATIONS Caulking Gun Grout PUMP 2 1 HP 14 4 AMPS 120V E Z INSTALL WHIRLPOOL HEATER 12 0 AMPS 120V GENERAL INSTALLATION INFORMATION Carefully uncrate and inspect your new bath for any shipping damage If such damage is found report it to your vendor immediately After inspection and during installation protect the bath from construction damage After installation and before enclosing with wallboard tile etc water test the unit and check for leaks Do not make modifications to the whirlpool system or remove pump from factory mounting This could adversely affect the
9. assembled with the E Z Install Whirlpool Heater Your E Z Install whirlpool bathtub heater has been specifically designed to enhance the enjoyment of your whirlpool bath Once filled the temperature of the whirlpool bath is constantly maintained by a built in thermostat for as long as you desire Your E Z Install whirlpool bathtub heater is totally self contained to insure trouble free operation As with all electrical devices certain safety precautions should be taken during operation Please read and follow all instructions carefully IMPORTANT SAFETY INSTRUCTIONS DO NOT DISCARD INSTRUCTIONS PERTAINING TO A RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS READ AND FOLLOW ALL INSTRUCTIONS You should have received safety instructions with your whirlpool bathtub system Please read and follow them carefully Those instructions will include the following warnings 1 WARNING Risk of Electrical Shock Do not permit any electrical appliances such as a light telephone radio or television within five feet of the whirlpool bathtub 2 DANGER To reduce the risk of injury do not remove the suction cover from the whirlpool bathtub 3 To Reduce the Risk of Injury a The water in your whirlpool should not exceed 104 Fahrenheit Lower water temperatures are recommended for extended use exceeding 10 15 minutes and are definitely recommended for younger children b Pregnant or possibly pregnant women should consult
10. by tracing a line on to the studs see Figure 1 2 Remove the whirlpool and attach a 2 x 4 stringer to the studs with the top of the stringer touching the traced line 3 Install drain components to the whirlpool following the manufacturers instructions Before replacing your whirlpool for final installation be certain that an opening has been provided in the sub floor for the drain See the roughing in drawing for suggested opening size and location dimensions 4 Replace whirlpool and re shim the integral support feet shimming the entire length of the support feet Secure the shims using construction adhesive silicone mortar or equivalent materials While not a necessity the use of a foundation base consisting of cement e g Sakrete mortar or grout will help provide a solid and secure installation FIG 1 ao WALLBOARD TILE SEALANT BEAD STRIP BATH ADHESIVE 495mm 19 1 2 LEVELING SS STRINGER Te NOTE Tile bead kit not included and must be purchased separately TYPICAL INSTALLATION TRACED OUTLINE CUTOUT 495mm ye WHIRLPOOL ACCESS PANEL SEE CUTOUT TEMPLATE PROVIDED FOR UNITS WITH OPTIONAL APRON PANEL SEE APRON INSTALLATION INSTRUCTION 751680 100 UNLESS AN ACCESS OPENING OF AT LEAST 12 X 24 305 X 610MM IS PROVIDED WARRANTY SERVICE WILL NOT BE PERFORMED 752864 100 Rev C 2 E Z Install Heater Whirlpool Heater This whirlpool tub has been
11. in a manner inconsistent with the product as shipped by American Standard American Standard s option to repair or exchange the product under this warranty does not cover any labor or other costs of removal or installation nor shall American Standard be responsible for any other incidental or consequential damages attributable to a product defect or to the repair or exchange of a defective product all of which are expressly excluded from this warranty Some states or provinces do not allow the exclusion or limitation of implied warranties so this exclusion may not apply to you This warranty gives you specific legal rights You may have other statutory rights that vary from state to state or from province to province in which case this warranty does not affect such statutory rights For service under these warranties it is suggested that a claim be made through the contractor or dealer from or through whom the product was purchased or that a service request including a description of the product model and of the defect be sent to the address above 752864 100 Rev C 6
12. ing No 8 AWG copper wire bond each of these assemblies together to the homes electrical panel or approved local bonding point ELECTRICAL DIAGRAM READ AND FOLLOW ALL INSTRUCTIONS 752864 100 Rev C 4 WIRE SELECTION GUIDE Maximum distance from fusebox to motor The sizes shown on this chart are recommendations Motor for copper conductors Hi Performance only Always follow Rati o4 115V Power Line local and national 10 electrical codes DRAIN CONNECTION AND SYSTEM TEST Using recommended drain opening connect whirlpool drain to waste line Tighten all drain joints securely Check the pump couplings and make sure they are hand tight Clean the whirlpool and fill with water to a point 2 above the top of the highest jet Recheck the pump couplings and make certain that they are not leaking Although the pump couplings are factory tightened and inspected some loosening may have occured during transit Make sure the whirlpool is connected to the electrical supply and turn the whirlpool on Check for leaks around all piping connections while the whirlpool is running E Z INSTALL WHIRLPOOL HEATER OPERATION WARNING Prior to operation review the Important Safety Instructions listed in this instruction manual Once the heater is installed and the whirlpool pump is operating the heater is totally automatic The heater will help maintain the temperature of the water in the bath Pressure Switch The heater is equipped
13. me Warranty for the Elite Line of Acrylic Whirlpools American Standard warrants to the original consumer purchaser that it will at its option repair or replace this whirlpool or any of its parts that are found by American Standard in its sole judgment to be defective under normal residential use and maintenance so long as it is owned by the original consumer purchaser This warranty shall only become effective upon receipt by American Standard of a completely filled out Warranty Registration Card evidencing proof of purchase THIS WARRANTY SHALL BE VOID IF THE ACCESS PANEL TO THE WHIRLPOOL IS COVERED IN ANY MANNER CONTRARY TO THE INSTALLATION INSTRUCTIONS In no event will American Standard be liable for the cost of repair or replacement of any installation materials including but not limited to tiles marble etc This limited warranty DOES NOT COVER the following 1 Defects or damages arising from shipping installation alterations accidents abuse misuse lack of proper maintenance and cleaning as directed in the owner s manual and use of other than genuine American Standard replacement parts in all cases whether caused by a plumbing contractor service company the owner or any other person 2 Deterioration through normal wear and tear and the expense of normal maintenance 3 Commercial application 4 Options and accessories American Standard s limited warranty on these items is one year for parts only and excludes labor This one yea
14. r limited warranty covers accessories manufactured by American Standard e g aprons drains grab bars heaters trim kits against defects of material or workmanship Warranty coverage begins on the date the accessory was originally purchased by the owner 5 Postage or shipping costs for returning products for repairs or replacement under this limited warranty and labor or other costs incurred in connection with product removal or installation under this limited warranty 6 ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES ALL OF WHICH ARE HEREBY EXPRESSLY DISCLAIMED OR THE EXTENSION BEYOND THE DURATION OF THIS LIMITED WARRANTY OF ANY IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY OR FITNESS FOR AN INTENDED PURPOSE Some jurisdictions do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so these limitations and exclusions may not apply to you 7 Responsibility for compliance with local code requirements Since local code requirements vary greatly distributors retailers dealers installation contractors and users of plumbing products should determine whether there are any code restrictions on the installation or use of a specific product This warranty gives you specific legal rights You may have other legal rights that vary from state to state For service under this warranty you should contact the following By Mail By Telephone American Standard

Download Pdf Manuals

image

Related Search

Related Contents

Manual esteira ep-1100 - rev.3  TELEPHONE USER GUIDE  ROLINE GOLD Cinch Cable, simplex M - F, white 2.5 m  Atlus Etrian Mystery Dungeon  Metapace l-42DT User Guide V1.0  FT Aquabrome    firefly 302 plus  Avaya Nortel Business Communications Manager 450 1.0 Unified Messaging Configuration Guide  Guida per l`utente  