Home
American Standard BERWICK M968641 User's Manual
Contents
1. EAUCET to complete faucet mounting BASE MOUNTING SURFACE Aififi t a yf ol YS COLLAR ON S MOUNTING NUT Figure B 2 POP UP DRAIN m Remove CLEAR PLASTIC COVER 1 E Remove CARDBOARD SPACER 2 from under DRAIN POP UP 3 E Tighten TAILPIECE 4 on DRAIN BODY before installing DRAIN BODY Fig B 3 REMOVE FLANGE E Thread FLANGE 1 counter clockwise and remove FLANGE 1 and FOAM GASKET 2 from drain body Fig A E Thread LOCKNUT 3 clockwise to bottom of drain body Push GASKET 4 down against LOCKNUT 3 Fig B INSTALL DRAIN FROM BELOW FIXTURE E From under side of SINK Tighten LOCKNUT 1 firmly with Adjustable install DRAIN BODY 1 up Wrench or Channel Locks through drain outlet Note No plumber s putty or caulk is required The CABLE ATTACHMENT POINT 2 must face towards the rear of the SINK E Install FOAM GASKET 3 and FLANGE 4 onto drain body from above SINK and tighten FLANGE 4 firmly m Check DRAIN FLANGE in SINK to ensure that WHITE FOAM GASKET 3 is fully compressed and not visible Fig A i WHITE FOAM m POP UP KNOB 1 must be fully down Fig B CASKET DRAIN NOT VISIBLE FLANGE ae a M968641 F ATTACH CABLE CONNECTOR E Thread CABLE CONNECTOR 1 clockwise onto DRAIN BODY CONNECTION 2 and hand tighten Fig A Your new POP UP DRAIN installation is now complete Fig B Note
2. Tailpeice on pop up drain is 1 1 4 0 D Fig B CHECK OPERATION OF POP UP Operate LIFT KNOB 1 to verify that STOPPER 2 opens and closes Note If STOPPER 2 does not open and close properly then refer to the troubleshooting section of these instructions 9 MAKE WATER SUPPLY AND WASTE CONNECTIONS E Connect FLEXIBLE SUPPLIES 1 2 directly to wall supplies Connection on fitting supplies are 3 8 compression Connect left SUPPLY 1 to Hot Marked with a Red Band and right supply to COLD 2 wall supply Faucet supplies are 20 long from faucet base Note If additional supply length is required installer must purchase additional parts separately Important If SUPPLY HOSES 1 2 are to long loop as illustrated to avoid kinking Connect 1 1 4 O D tailpiece on POP UP DRAIN to OX 20 waste outlet BAND M968641 1 0 TEST INSTALLED FITTING With HANDLE 1 in OFF position turn on WATER SUPPLIES 2 and check all connections for leaks m Remove AERATOR 3 Operate HANDLE 1 to flush water lines thoroughly Replace AERATOR 3 CHECK DRAIN CONNECTIONS Operate POP UP KNOB 4 and fill lavatory with water Check that DRAIN STOPPER 5 makes a good seal and retains water in Sink If DRAIN STOPPER 5 does not seal properly please refer to Troubleshooting section in these instructions Release POP UP KNOB 4 down and check all drain connections and P trap for leaks m Tighten if
3. necessary WASTE OUTLET Turn off hot and cold water SERVICE CAUTION supplies before beginning m Toremove or replace cartidge a Turn valve to OFF position a Pull out PLUG BUTTON 1 and remove HANDLE SCREW 2 Pull off HANDLE 3 and CAP 4 a Unthread CARTRIDGE NUT 5 and remove a Pull out CARTEIDGE 6 S a Inspect CARTRIDGE 6 and O RINGS 7 for debris and clean asz 55 if necessary nE a Clean MANIFOLD 8 and rinse clean a Reinstall CARTRIDGE 6 and O RINGS 7 onto MANIFLOD 8 a Reinstall CARTRIDGE NUT 5 CAP 4 and HANDLE ASSEMBLY 3 If spout drips operate handle several times from OFF to ON and HOT to COLD position Do not force handles turn only 90 1 2 CARE INSTRUCTIONS DO SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER DRY WITH A SOFT COTTON FLANNEL CLOTH DO NOT DO NOT CLEAN THE PRODUCT WITH SOAPS ACID POLISH ABRASIVES HARSH CLEANERS OR A CLOTH WITH A COARSE SURFACE M968641 Speed Connect Drain Troubleshooting Guide If sink does not hold water even though Stopper is in the down position e Follow CABLE ADJUSTMENT PROCEDURE If mea tee does not raise up fully or sink drains too slowly e Follow CABLE ADJUSTMENT PROCEDURE If you need to remove the Stopper e Follow STOPPER REMOVAL PROCEDURE If you would like the ability to remove your Stopper simply by lifting it out of the drain e Follow STOPPER INSTALLATION PROCEDURE for Unlocked mode CABLE A
4. D FRONT OF SINK Re install the Cam Cap making sure the guide teeth are facing Qs outward If the Cam Cap does not snap into place then rotate DRAIN the Cam to make sure it is fully inserted Fig K Re attach Cable See CABLE ADJUSTMENT PROCEDURE in Unlocked Mode Troublingshooting Guide to complete installation Stopper will be in Unlocked mode and removable INSTALL CAM CAP MS68641
5. DJUSTMENT PROCEDURE Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam in the illustration Fig B Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go At this point the Stopper should be in the UP position Fig B C Push DOWN on the Lift Knob to make sure it is fully down Fig C Re attach the Cable to the Drain Body Connection 2 by threading the Cable Connector 1 clockwise onto the Drain Body Connection 2 and hand tighten Fig A Fig B Fig C STOPPER REMOVAL PROCEDURE Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam and Cam Cap in the illustration Fig B Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain Fig D Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal Fig E The Stopper can now be removed by lifting it out of the Drain Fig F fa JO ss Y E REMOVE CAM CAP M9686411 STOPPER INSTALLATION PROCEDURE The Stopper can be installed two ways Locked Mode Stopper cannot be removed or Unlock Mode Stopper is removable Locked Mode L
6. Installation Instructions BERWICK 7430 101 MONOBLOCK LAVATORY FAUCET with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain a feature found only on American Standard faucets Speed Connect Drain e Fewer parts installs in less time Certified to comply with ANSI A112 18 1 e Never needs adjustment M968641 e Guaranteed to seal properly the first time every time Your new American Standard faucet is designed to work only with the Speed Connect drain To ensure that your installation proceeds smoothly please read these instructions carefully before you begin Recommended tools s gt Screwdriver Channel Locks Tubing Cutter Ti ff h d cold INSTALL FAUCET MAAU supplies before beginning Seat SEAL 1 into under side of ESCUTCHEON RING 2 Seat ESCUTCHEON RING 2 with collar facing up into groove in faucet base Feed FAUCET SUPPLIES 3 MOUNTING STUD 4 and DRAIN CABLE ASSEMBLY 8 through ESCUTCHEON RING 2 and the mounting hole of lavatory or mounting surface Figure A From KEON poi GASKET 7 and RETAINING WASHER 5 onto MOUNTING STUD 4 Secure Faucet with MOUNTING NUT 6 pulling faucet to front of sink so SUPPLIES 3 rests against mounting hole Before final tightening make sure collar on MOUNTING NUT 6 is seated into RETAINING WASHER 5 Figure B Figure A Adjust Faucet so that it is centered Tighten MOUNTING NUT 6
7. ook at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig G To install the stopper in Locked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the rear of the Sink and the American Standard logo is facing front Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig G Re install the Cam into the Drain rotating the Cam if necessary to make sure it is fully inserted Fig J Loop TOWARD REAR OF SINK Re install the Cam Cap making sure the guide teeth are facing Qw outward If the Cam Cap does not snap into place then rotate DRAIN the Cam to make sure it is fully inserted Fig K Re attach Cable See CABLE ADJUSTMENT PROCEDURE in Locked Mode Troubling Shooting Guide to complete installation Stopper will be Vandal Proof in Locked mode and not be removable Unlocked Mode Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink and the American Standard logo is facing rear Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig H Re install the Cam into the Drain rotating the Cam if necessary f we to make sure it is fully inserted Fig J Gj LOOP TOWAR
Download Pdf Manuals
Related Search
Related Contents
4月10日号 MasterTool Programming/Manuais e Apostilas/MP399100 Copyright © All rights reserved.
Failed to retrieve file