1. 0369 a only 1 905 3061093 LEJ INSTALL WIRE HANGER 1 Install EYEBOLT onto WIRE HANGER if not installed 3 Place WIRE end in right SIDE HOLE near DRAIN 2 Place WIRE end in left SIDE HOLE WIRE HANGER NOTE If not enough tension remove WIRE and spread ends approx 1 additional and re attach 4 WIRE HANGER is positioned behind ELECTRONIC BOX 6 EYEBOLT for SINK APRON and in front of DRAIN 5 Remove THUMB NUT from EYEBOLT WIRE HANGER EYEBOLT REMOVE THUMB NUT FROM EYE BOLT 5 7301793 100 Rev D ule INSTALL SINK APRON 3 Remove the APRON Clean the wall where the APRON BRACKETS supplied with SINK are to be applied Peel off the 1 Hold APRON up against SINK and flush against finished wall protective strip from the back of the APRON BRACKETS Apply the two APRON BRACKETS to the finished wall parallel to the pencil 2 Mark a line with a pencil on the wall about 6 long as shown on marks as shown in the illustration below both sides of the APRON OPTIONAL MOUNTING SCREWS AND ANCHORS NOT SUPPLIED Use Brackets to mark pilot holes on wall Drill holes for ANCHORS Peel off the protective strip from the back of the APRON BRACKETS Apply the two APRON BRACKETS to the finished wall parallel to the pencil marks as shown and aligned with the mounting holes See illustration below Install SCREWS and tighten 4 Clean off the pencil marks from wall PROTECTIVE CLEAN WALL PENCIL MARK I e
2. is too long loop to avoid kinking u INSTALL AND CONNECT MIXING VALVE MIXING VALVE IS OPTIONAL Ena 1 Remove COVER from MIXING VALVE WRENCH 2 Install FIBER SEAL WASHER 4 on MIXING VALVE NIPPLE 3 Hold MIXING VALVE 1 in place with one hand and with your other hand thread SWIVEL NUT 2 onto MIXING VALVE NIPPLE 3 Use an adjustable wrench to tighten SWIVEL NUT 2 3 Place MIXING VALVE BOX onto MOUNTING PLATE Align BOX with mounting holes Attach with SCREWS provided 4 Replace COVER and tighten securely NOTE For complete detailed installation and operating instructions see installations instructions supplied with mixing valve No M968808 SELECTRONIC Thermostatic Mixing Valve 605XTMV 374 CONNECT MIXING VALVE TO WATER SUPPLIES 1 Turn off Hot and Cold water supplies before beginning 2 Connect FLEXIBLE SUPPLIES directly to wall supplies Connections on MIXER supplies are 3 8 compression Connect left supply to Hot and right supply to Cold wall supply Use adjustable wrench to tighten connections Do not over tighten 2 e par oO a 2 e par 2 No M968808 i 3 Faucet supplies measure 20 from the bottom of the sas ENCLOSURE 3 base ut American Standard Faucets visit our website at www us amstd com or U ustomer s e mail jucetsupport amstd com pes cat 1 800 442 1902 In Canada 1 800 387 0369 Note If additional supply length
3. rights In the United States In Canada In Mexico American Standard Brands AS Canada ULC American Standard B amp K Mexico P O Box 6820 5900 Avebury Rd S de R L de C V Piscataway New Jersey 08855 Mississauga Ontario Via Morelos 330 Attention Director of Customer Care Canada L5R 3M3 Col Santa Clara For residents of the United States warranty Toll Free 800 387 0369 Ecatepec 55540 Edo Mexico information may also be obtained by calling www americanstandard ca Toll Free 01 800 839 1200 the following toll free number 800 442 1902 www americanstandard com mx www americanstandard com THIS WARRANTY IS NOT TRANSFERABLE FROM ORIGINAL CONSUMER PURCHASER 7301793 100 Rev D 8
4. 1 2 13mm 5 Position APRON under SINK and against finished wall alinging 6 Retain APRON with THUMB NUT Finger tight only EYEBOLT with hole in APRON APRON THUMB NUT IMPORTANT SAVE ALL INSTALLATION INSTRUCTIONS FOR FUTURE USE 7301793 100 Rev D 6 Repair Parts Americam Standard C Sais aaa Models 9118 111 9118 100 amp 9118 150 7381267 400 0070A Mounting Bracket Kit 7381243 251 0020A Offset Drain 7381242 0500A P Trap Assembly 7381266 200 0070A Bracket Assembly 7381259 401 0200A ICU Sink Shroud Kit 7 7301793 100 Rev D AS AMERICA INC ONE YEAR LIMITED WARRANTY If inspection of this AS America Inc American Standard plumbing product within one year after its initial purchase confirms that it is defective in materials or workmanship American Standard will repair or at its option exchange the product for a similar model This limited warranty applies only to the original purchaser and installation of these products In the event of a limited warranty claim proof of purchase will be required save sales receipt This limited warranty does not apply to local building code compliance Since local building codes vary considerably the purchaser of this product should check with a local building or plumbing contractor to insure local code compliance before installation This limited warranty is void if the product has been moved from its initial place of installation if it has be
5. INSTALLATION INSTRUCTIONS American Standard Style That Works Better ICU Sink System Models 9118 111 9118 100 amp 9118 150 Introduction Thank you for selecting our products products which have been the ei benchmarks of fine quality for years To help insure that the installation process will proceed smoothly please read these instructions carefully before you begin Also review the recommended tools and materials list carefully unpack and examine your new plumbing fixture p 5 A CAUTION PRODUCT IS FRAGILE TO AVOID DAMAGE AND POSSIBLE INJURY HANDLE WITH CARE NOTE Pictures may not exactly define contour of china and components Recommended Tools amp Materials Tape El Measure Hl o El olol LLI Pipe Wrench g Hacksaw A N Tubing Cutter A Level ey 8 E3 OE Pencil ol Channel Lock Pliers Phillips Screwdriver Regular Screwdriver Ww 20 am Rough In j FINISHED WALL 5 Dimensions f A H j A A f TE FAUCET PERCH p 2 1 2 DIA 65mm Y f oc 8 203mm BETWEEN f MOUNTING HOLES f FAUCET PERCH f O 2 1 2 DIA 65mm f p LL f LI 40 1 8 1020mm f FINISHED FINISHED gt FLOOR FLOOR IP PSLLELALILLLLL lt o RECOMMENDED CARRIERS FLOOR ra FINISHED pacsemount JAY R SMITH MFG CO DETAIL on ee T MODEL SQ 0 4437 FLOOR MOUNTED SINK SUPPORT DISCLAIMER Faucets with a base diameter greater than 2 1 4 57 m
6. N AND OFFSET TAILPIECE 1 Apply plumber s putty to the underside of flange Install GRID DRAIN into drain outlet 2 From the underside of SINK install RUBBER GASKET flat side up and FRICTION GASKET onto GRID DRAIN threads Apply sealent to threads of GRID DRAIN 3 Apply sealent to threads of OFFSET TAILPIECE and thread into DRAIN ELL 4 Thread DRAIN ELL onto GRID DRAIN tighten and align as shown FRICTION GASKET DRAIN ELL PLUMBER S PUT is APPLY SEALANT OFFSET TAILPIECE TO THREADS 7301793 100 Rev D 2 INSTALL ICU SINK 1 Mount SINK onto the two HANGER STUDS Hold SINK in place and temporarily install NYLOCK NUT amp WASHER on one of the HANGER STUDS to retain SINK HANGER STUD NYLOCK NUT AND WASHER COMPLETE WASTE OUTLET CONNECTION 1 Install P TRAP Connect OFFSET TAILPIECE to P TRAP TAILPIECE may have to be cut to fit installation Use tubing cutter to cut TAILPIECE 1 1 4 OD 1 1 4 or 1 1 2 OD WASTE OUTLET CONNECT SPOUT HOSE TO ENCLOSURE 1 Connect SUPPLY NUT 1 from SPOUT assembly to nipple on top of ENCLOSURE 2 Tighten with adjustable wrench to make a water tight connection INSTALL ELECTRONICS HANGER BRACKET 1 Install the ELECTRONICS HANGER BRACKET onto remaining HANGER STUD Install NYLOCK NUT amp WASHER but do not tighten fully 2 Remove NYLOCK NUT amp WASHER from first HANGER STUD and install other end of ELECTRONICS HANGER BRACKET Repla
7. ce NYLOCK NUT amp WASHER tighten both ends Do not over tighten chinaware could become damaged T MOUNT ELECTRONICS BOX NOTE Installation with ELECTRONIC BOX only is for cold or tempered water Use optional MIXING VALVE with ELECTRONIC BOX when Hot and Cold supplies are roughed in See illustration below I I I Bar ELECTRONIC BOX ELECTRONIC BOX i COLD WATER OR MIXING VALVE TEMPERED WATER i 3 8 SUPPLY OLD 1 Remove COVER from ELECTRONICS BOX 2 Place ELECTRONICS BOX onto MOUNTING PLATE Align BOX with mounting holes Attach with SCREWS provided 3 Hang MOUNTING PLATE with ELECTRICAL BOX on HANGER BRACKET 7301793 100 Rev D eE CONNECT WATER SUPPLY TO ENCLOSURE AND TO COLD OR TEMPERED WALL SUPPLY 1 Insert FIBER WASHER 4 into SUPPLY NUT 1 on ENCLOSURE 2 2 Connect SUPPLY NUT 1 on ENCLOSURE 2 to FLEXIBLE SUPPLY HOSE 3 Tighten to make a water tight connection Use ae oa two wrenches to tighten if necessary ELECTRONIC BOX 3 Connect FLEXIBLE SUPPLY 3 directly to wall supply Connection on FLEXIBLE SUPPLY 3 is 3 8 compression Use adjustable wrench to tighten connection Do not over tighten OR TEMPERED Note FLEXIBLE SUPPLY 3 measures 20 from the bottom of AEE ERREN the ENCLOSURE 1 base If additional supply length is required installer must purchase parts separately Important If FLEXIBLE SUPPLY 3
8. en subjected to faulty maintenance abuse misuse accident or other damages if it was not installed in accordance with American Standard s instructions or if it has been modified in a manner inconsistent with the product as shipped by American Standard American Standard s option to repair or exchange the product under this limited warranty does not cover any labor or other costs of removal or installation INNO EVENT WILL AMERICAN STANDARD BE LIABLE FOR THE COST OF REPAIR OR REPLACEMENT OF ANY INSTALLATION MATERIALS INCLUDING BUT NOT LIMITED TO TILES MARBLE ETC American Standard will not be responsible for any other incidental or consequential damages attributable to a product defect or to the repair or exchange of a defective product all of which are expressly excluded from this limited warranty This limited warranty does not cover any liability for consequential or incidental damages all of which are hereby expressly disclaimed or the extension beyond the duration of this limited warranty of any implied limited warranties including those of merchantability or fitness for an intended purpose Some states or provinces do not allow the exclusion or limitation of implied limited warranties so this exclusion may not apply to you This limited warranty gives you specific legal rights You may have other statutory rights that vary from state to state or from province to province in which case this limited warranty does not affect such statutory
9. is required installer must purchase parts separately Important If SUPPLY HOSES 1 2 are too long loop as to avoid kinking 188 ELECTRICAL HOOK UP AND INSTALLATION For complete detailed installation and operating instructions see installations instructions supplied with ICU FAUCET No M965119 SELECTRONIC Proximity ICU Faucet MIXING VALVE No M965119 To learn more about Am n Standard Faucets visit our website or U S customer s e mail us at faucetsupport americanstandard co mail u For Parts Service Warranty or other Assistance please call 1 800 442 1902 In Canada 1 800 387 0369 In Toronto Area only 1 905 306 1093 7301793 100 Rev D 4 LE CHECK ALL ELECTRICAL AND C TEST INSTALLED FAUCET PLUMBING CONNECTIONS 1 Turn on water supplies and check for TO ENSURE A LAMINAR WATER FLOW the leaks Tighten any connections if air must be slowly purged from the spout To necessary do so cover the SENSOR 1 while slowly a Opening the water supply valves When the 2 Check FAUCET operation if water flows as a solid smooth steady stream adjustment is required refer to the uncover the SENSOR 1 and fully open the installation instructions shown at right water supply valve supplied with the ICU FAUCET No M965119 SELECTRONIC Proximity ICU Faucet Installation Instructions No M965119 our For Parts Service Warranty or please call 1 800 442 1902 1 800 387
10. m will not fit on this WATTS CA 311 ICU Sink The Selectronic ICU Faucet was specifically designed to minimize splashing during operation American Standard will not be liable for any splashing that occurs if faucets other FLOOR MOUNTED URINAL CARRIER than the American Standard ICU Faucets are used Product names listed herein are trademarks of AS America Inc AS America Inc 2012 1 7301793 100 Rev D IE ROUGH IN SUPPLIES AND WASTE OUTLET ya INSTALL FAUCET 1 Rough in 3 8 supplies and waste outlet connections NOTE For more detailed information see the installation instructions supplied with the ICU FAUCET M965119 1 Insert WIRES 1 FLEX HOSE 2 and SPOUT SHANK 3 through center hole of mounting surface NOTE For ease of installation and accessibility it is recommended that straight stops with flex supply tubes be used As an alternative if rigid supply risers are used it is suggested to use angle stops in place of the straight stops 2 Assemble C WASHER 4 STAR WASHER 5 and LOCKNUT 6 onto threads of SPOUT SHANK 3 from underside of mounting surface 3 Align FAUCET and tighten LOCKNUT 6 SQ 0 4437 FLOOR FINISHED WALL MOUNTED SINK MOUNTING STUDS SUPPORT 7 5 8 41mm ge k e 203mm 102mm 36 1 2 102MM 3 8 10mm AN SUPPLIES 1 1 4 32mm OR 1 1 2 38mm WASTE OUTLET CHECK LOCAL CODES INSTALL GRID DRAI