1. WHITE FOAM GASKET 3 is fully compressed and not visible Fig A E POP UP KNOB 1 must be fully down Fig B WHITE FOAM GASKET NOT VISIBLE M966230 Rev 1 2 F ATTACH CABLE CONNECTOR Thread CABLE CONNECTOR 1 clockwise onto DRAIN BODY CONNECTION 2 and hand tighten Fig A Your new POP UP DRAIN installation is now complete Fig B Note Tailpeice on pop up drain is 1 1 4 0 D Fig B CHECK OPERATION OF POP UP Operate LIFT KNOB 1 to verify that STOPPER 2 opens and closes Note If STOPPER 2 does not open and close properly then refer to the troubleshooting section of these instructions MAKE WATER SUPPLY AND WASTE CONNECTIONS NOTE FLEXIBLE SUPPLIES OR BULL NOSE RISERS NOT INCLUDED AND MUST BE PURCHASED SEPARATELY Thread TEE BODY 4 to SPOUT SHANK 5 Thread HOSE CONNECTOR 6 GA to VALVE CONNECTIONS 7 7A Connect water supply to VALVE BODIES 1 1A with 1 2 IPS FLEXIBLE SUPPLIES 2 or 3 8 0 D BULL NOSE RISERS 3 Use adjustable wrench to tighten connections Do not over tighten Be careful not to kink copper supply when bending Use tubing cutter to cut to proper length Connect HOT water supply to inlet of left SHANK and COLD water supply to right SHANK using sealant appropriate connectors and COUPLING NUTS COUPLING Connect 1 1 4 O D tailpiece on POP UP DRAIN to waste outlet 1 2 PIPE THREAD 3 3 8 0 D _ BULL NOSE COMPRESSION RISERS NUT S F
2. replace DO NOT DO NOT CLEAN THE z Replace SPRING CLIP 1 PRODUCT WITH SOAPS ACID Replace ADAPTER HANDLE SCREW and POLISH ABRASIVES HARSH INSERT CLEANERS OR A CLOTH WITH AERATOR may accumulate dirt causing distorted and reduced A COARSE SURFACE water flow Remove AERATOR and rinse clean If spout drips operate handles several times from OFF to ON position Do not force handles turn only 90 M966230 Rev 1 2 Speed Connect Drain Troubleshooting Guide If sink does not hold water even though Stopper is in the down position e Follow CABLE ADJUSTMENT PROCEDURE If Stopper does not raise up fully or sink drains too slowly e Follow CABLE ADJUSTMENT PROCEDURE If you need to remove the Stapper e Follow STOPPER REMOVAL PROCEDURE If you would like the ability to remove your Stopper simply by lifting it out of the drain e Follow STOPPER INSTALLATION PROCEDURE for Unlocked mode CABLE ADJUSTMENT PROCEDURE Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam in the illustration Fig B Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go At this point the Stopper should be in the UP position Fig B C Push DOWN on the Lift Knob to make sure it is fully down Fig C Re attach the Cable to the Drain Bod
3. Amiran Standard Installation a Instructions AMARILis LEXINGTON Spread Lavatory Faucet with the Speed Connect Drain Congratulations on purchasing your American Standard faucet with the Speed Connect drain a feature found only on American Standard faucets Speed Connect Drain Certified to comply with ANSI A112 18 1 e Fewer parts installs in less time M966230 Rev 1 2 e Never needs adjustment e Guaranteed to seal properly the first time every time Your new American Standard faucet is designed to work only with the Speed Connect drain To ensure that your installation proceeds smoothly please read these instructions carefully before you begin Recommended tools o o G Screwdriver Channel Locks Adjustable Wrench Tubing Cutter INSTALL SPOUT EZUNM iins before beanna Insert SPOUT 1 and CABLE CONNECTOR 2 through center hole making sure the SPOUT SEAL WASHER 3 is properly seated Assemble RUBBER WASHER 4 BRASS WASHER 5 and LOCKNUT 6 onto SPOUT SHANK 7 from under side of sink Make sure SPOUT 1 is centered in the mounting hole and the slot in the BRASS WASHER 5 faces toward the rear of the sink Tighten LOCKNUT 6 firmly Fig A INSTALL VALVE BODY m Place RUBBER RING 9 into DECK ADAPTER 10 Install LOCKNUT 11 and RUBBER WASHER 12 onto VALVE BODY 13 From under side of mounting surface install VALVE BODY 13 through valve mounting holes Threads of VALVE BODY 13 should extent
4. LEXIBLE FERRULE SUPPLIES 3 8 COMPRESSION CONNECTION M966230 Rev 1 2 INSTALL HANDLES Turn off hot and cold water CAUTION supplies before beginning E See separate instruction sheet supplied with handle kit for handle installation TEST INSTALLED FITTING With VALVE 1 in OFF position turn on WATER SUPPLIES 2 and check all connections for leaks imp Remove AERATOR 3 Operate both HANDLES 1 to flush water lines thoroughly Replace AERATOR 3 1 2 CHECK DRAIN CONNECTIONS E Operate POP UP KNOB 5 and fill Sink with water Check that DRAIN STOPPER 4 makes a good seal and retains water in Sink If STOPPER 4 does not seal properly please refer to Troubleshooting Guide in these instructions Release POP UP KNOB 5 down and check all drain connections and P trap for leaks m Tighten if necessary TO CLEAN AERATOR AERATOR 3 may accumulate dirt causing distorted and reduced water flow Unscrew and remove gt A AERATOR 8 and rinse clean pe P TRAP Replace AERATOR 3 and operate handles several times from OFF to ON position Do not force handles turn only 90 To change direction of handle rotation DO SIMPLY RINSE THE PRODUCT proceed as follows 7 CLEAN WITH CLEAR WATER DRY a Turn valve to OFF position WITH A SOFT COTTON FLANNEL m Remove INSERT and HANDLE SCREW CLOTH a Slip HANDLE with ADAPTER off Remove SPRING CLIP 1 Lift STOP WASHER 2 turn 90 and
5. at least 5 16 of a inch above mounting surface top Fig B Thread DECK ADAPTER 10 onto VALVE BODY 13 until snug against internal stop If necessary adjust LOCKNUT 11 E Tighten LOCKNUT 11 with WRENCH 8 supplied to secure VALVE BODY 13 Repeat above steps for opposite VALVE BODY 13A 10 gt 9g MOUNTING 5 16 MIN SURFACE y ALZA gmail A Lian gt Lo 2 POP UP DRAIN E Remove CLEAR PLASTIC COVER 1 E Remove CARDBOARD SPACER 2 from under DRAIN POP UP 3 m Tighten TAILPIECE 4 on DRAIN BODY before installing DRAIN BODY Fig B S A Zz ite y SI 3 REMOVE FLANGE E Thread FLANGE 1 counter clockwise and remove FLANGE 1 and FOAM GASKET 2 from drain body Fig A E Thread LOCKNUT 3 clockwise to bottom of drain body Push GASKET 4 down against LOCKNUT 3 Fig B INSTALL DRAIN FROM BELOW FIXTURE E Tighten LOCKNUT 1 firmly with Adjustable From under side of SINK Wrench or Channel Locks install DRAIN BODY 1 up through drain outlet Note No plumber s putty or caulk is required The CABLE ATTACHMENT POINT 2 must face towards the rear of the SINK Install FOAM GASKET 3 and FLANGE 4 onto drain body from above SINK and tighten FLANGE 4 firmly FLANGE GASKET AND POP UP KNOB Check DRAIN FLANGE in SINK to ensure that
6. nstall the Cam Cap making sure the guide teeth are facing O outward If the Cam Cap does not snap into place then rotate DRAIN the Cam to make sure it is fully inserted Fig K Re attach Cable See CABLE ADJUSTMENT PROCEDURE in Locked Mode Troubling Shooting Guide to complete installation Stopper will be Vandal Proof in Locked mode and not be removable Unlocked Mode Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink and the American Standard logo is facing rear Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig H Re install the Cam into the Drain rotating the Cam if necessary to make sure it is fully inserted Fig J LOOP TOWARD FRONT OF SINK Re install the Cam Cap making sure the guide teeth are facing Q outward If the Cam Cap does not snap into place then rotate DRAIN the Cam to make sure it is fully inserted Fig K Re attach Cable See CABLE ADJUSTMENT PROCEDURE in Unlocked Mode Troublingshooting Guide to complete installation Stopper will be in Unlocked mode and removable INSTALL CAM CAP M966230 Rev 1 2
7. y Connection 2 by threading the Cable Connector 1 clockwise onto the Drain Body Connection 2 and hand tighten Fig A Fig B f Fig C STOPPER REMOVAL PROCEDURE Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam and Cam Cap in the illustration Fig B Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain Fig D Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal Fig E The Stopper can now be removed by lifting it out of the Drain Fig F REMOVE CAM CAP M966230 Rev 1 2 STOPPER INSTALLATION PROCEDURE The Stopper can be installed two ways Locked Mode Stopper cannot be removed or Unlock Mode Stopper is removable Locked Mode Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig G To install the stopper in Locked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the rear of the Sink and the American Standard logo is facing front Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig G Re install the Cam into the Drain rotating the Cam if necessary to make sure it is fully inserted Fig J LOOP TOWARD REAR OF SINK Re i

Download Pdf Manuals

image

Related Search

Related Contents

Bedienungsanleitung London 8 (de)  ASUS A88X-PRO T9072 User's Manual  Samsung PS-42E7H Benutzerhandbuch  Acer TravelMate P2 253-MG-32344G50Mak  Manual en PDF  Samsung SC15H4030V User Manual (Windows 7)  Samsung Samsung Corby 2 S3850 Manuel de l'utilisateur  Fujitsu PRIMERGY TX100 S2  Bria Android Edition User Guide  ポンプ・モータ使用上の注意  