Home

American Standard 2703.XXXW Series User's Manual

image

Contents

1. 508 mm BATHING WELL AT RIM c 58 X 26 1 4 In 1473 mm X 667 mm WATER DEPTH TO OVERFLOW_____________14 1 2 In 368 mm FLOOR LOADING 48 Lbs Sq Ft 231 Kgs Sq m PROJECTED AREA PTS 20 8 CUBE FT3 35 3 WHIRLPOOL ELECTRICAL SPECIFICATIONS SYSTEM PUMP 1 6 HP 9 7 AMPS 120V SYSTEM II PUMP 2 1 HP 15 6 AMPS 120V FOR AFTER SALES SERVICE CALL 1 800 442 1902 WEEKDAYS 752358 100 REV H THANK YOU for selecting an American Standard bath Your new bath is shipped to you after careful inspection The whirlpool version is completely assembled with pump motor and system piping All you need to finish the installation are your selected fittings and electrical connections for a whirlpool To insure maximum performance and pleasure from this product please follow the instructions and cautions List of Optional Components not included e Apron Kit e Safe T Heater 9075 120 see your American Standard Distributor List of Required Components not included e Drain 1583 470 e Bath Filler see your American Standard Distributor List of Required Tools and Supplies Tools Supplies e Level e Nails e Tape Measure e Putty e Pipe Wrench e Caulking waterproof e Slip Joint Pliers e 1x3orr 2x2 e Screw Driver Stringers e Standard e Drop Cloth Woodworking Tools e 15 or 20 amp GFCI e Personal Safety Outlet Equipment e Cement Plaster e Caulking Gun Grout GENERAL INST
2. ALLATION INFORMATION Carefully uncrate and inspect your new bath for any shipping damage If such damage is found report it to your vendor immediately After inspection and during installation protect the bath from construction damage After installation and before enclosing with wallboard tile etc water test the unit and check for leaks If a whirlpool do not make modifications to the whirlpool system or remove pump from factory mounting This could adversely affect the safety and performance of the whirlpool and void the warranty Do not handle or move the whirlpool by the pump motor or piping system Fittings bath filler shower arm etc are not provided with the bath and must be ordered separately Framing and enclosing materials are provided by others Check for availability of optional American Standard wall tiling bead required for recess installations Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth WARNING Do not lift whirlpool by the piping har ness at any time American Standard Inc 2003 All product names listed herein are trademarks of American Standard Inc unless otherwise noted FRAMING AND INSTALLATION BATH MAY ONLY BE INSTALLED ABOVE THE FLOOR LINE IN A RECESS TYPE INSTALLATION AS SHOWN IN RECESS INSTALLATION DIAGRAM THE FOLLOWING PROCEDURE MUST BE USED FOR ALL INSTALLATIONS STRINGER OR PIER HEIGHT SHOULD BE AS INDICATED THE SUMP O
3. ELLISSE BUILT IN 2703 XXXW 2705 XXXW American Standard SERIES WHIRLPOOL HIGH GLOSS ACRYLIC SHOWN LESS ALL FITTINGS INSTALLATIO N INSTRUCTIONS 1524mm a 60 l 229mm 60 WATER RETENTION AL FLANGE 3 SIDES FINISHED DIMENSION WALL LINE See E l 387mm 15 1 4 813mm 1 32 l K 229x305mm CI OFA 9x12 FLOOR CUTOUT SUPPLIES o B ON OFF SWITCH 51mm rh 2 ALT PUMP PROVIDE ACCESS c L OF DRAIN LOCATION TO PUMP FOR SERVICING OUTLET ON ALL INSTALLATIONS PA es ciLor_ FINISHED WALL SHOWER ARM l SAFE T HEATER GALVES eta BLE l 65 78 REMOVABLE BLANK A254 T a OPTIONAL 102mm I WATER 305mm 4 Y SPOUT RETENTION _ 38mm 12 OPT l FLANGE 1 1 2 Lod fa i A E EAE TOJ 4 E LEVELING FN K STRINGER DEG ane TK UNDERSIDE 2 NOT FOR OF DECK 95mm C L OF 3 3 4 OVERFLOW SUPPORT 546mm ROUGH 21 1 2 q ae FLOOR aon INTEGRAL si FEET ii l ROUGH kl FLOOR 1 1 2 N P T FR ja mm mm THREADS 1 1 2 3 1 4 1 1 2 O D TAILPIECE GENERAL SPECIFICATIONS FOR 2703 5 WHIRLPOOL INSTALLED SIZE 60 x 32 x 21 1 2 In 1524 x 813 x 546mm WEIGHT 141 Lbs 63 Kg WEIGHT w WATER 643 Lbs 292 Kg GAL TO OVERFLOW ___ C C C C_0 Gaal 2771 WHIRLPOOL MIN OPERATING VOL __________50 Gal 189 L BATHING WELL AT SUMP 44 1 2 X 20 In 1130 mm X
4. F THE BATH IS SUPPORTED BY INTEGRAL FEET AND NO ADDITIONAL SUMP SUPPORT IS REQUIRED ONCE THE BATH IS IN PLACE THE FEET SHOULD BE SHIMMED ACCORDINGLY SO THAT THE RIM OF THE BATH CONTACTS THE STRINGER OR PIER BUT SUPPORTS NO WEIGHT ANY FINISH MATERIAL SUCH AS TILE OR WALL BOARD MUST BE SELF SUPPORTING IF IT CONTACTS THE RIM OF THE BATH LOCATE STUDS AS REQUIRED INSURE ROUGH DIMENSIONS ARE PROPER PLUMB AND SQUARE FOR REAR MOTOR MOUNT WHIRLPOOLS PROVISION MUST BE MADE IN ALL INSTALLATIONS FOR AN ACCESS OPENING FOR SERVICING PUMP AND CONTROLS TYPICAL RECESS INSTALLATION STUD FLANGE BRACKET INSTALLATION 1 X 3 LEVELING 2x4 STRINGER SUPPORT BATH FLANGE DRYWALL jis lt gt FLANGE 1527mm 1X3X8 BRACKET 60 1 8 LEVELING WALL STRINGER BOARD at X TILE ADHESIVE EALANT eee WHIRLPOOL ONLY BATH UNLESS AN ACCESS OPENING OF AT LEAST A GO E NO E SERANG 305mm X 610mm 12 X 24 IS PROVIDED AND BRACKETS PROVIDED S LEVELING WARRANTY SERVICE WILL NOT BE PERFORMED SEE STUD FLANGE BRACKET STRINGER INSTALLATION STUD FLANGE BRACKET INSTALLATION PROVIDED WITH THE BATH IS A PACKAGE OF 4 FOUR STUD FLANGE BRACKETS AND 8 EIGHT SCREWS INSTALL BRACKETS AND SCREWS AS SHOWN IN WALL BRACKET INSTALLATION DETAIL TWO BRACKETS SHOULD BE LOCATED EVENLY ACROSS THE BACK TILE FLANGE AND INSTALL ONE BRACKET ON EACH END OF THE BATH TOWARDS THE FRONT END OF THE TILE FLANGE THIS WILL ALLOW TI
5. LE FLANGE TO BE HELD SECURELY AGAINST STUDWALL OF RECESS INSTALLATION 752352 100 REV H 2 SPIC AND SPAN IS A REGISTERED TRADEMARK OF PROCTER amp GAMBLE ELECTRICAL INSTALLATION INSTRUCTIONS All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes WARNING When using electrical products basic precautions should always be observed including the following 1 DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a ground fault circuit interrupter 2 Grounding is required The unit should be installed by a licensed electrician and grounded 3 Install to permit access for servicing 4 All building materials and wiring should be routed away from the pump body and heater if equipped 1 6 HORSEPOWER MODELS The whirlpool should be installed on a 120 vac 15 amp dedicated circuit The circuit should be hard wired from the electrical power supply panel The circuit must be a three 3 wire circuit from the electrical supply panel A grounded neutral wire and a third wire earth ground are essential ADDING THE SAFE T HEATER REQUIRES A SEPARATE 15 AMP MAXIMUM GFCI CIRCUIT 2 1 HORSEPOWER MODELS The whirlpool should be installed on a 120 vac 20 amp dedicated circuit The circuit should be hard wired from the electrical power supply panel The circuit must be a three 93 wire circuit fron the electrical supply panel A grounded neutral wire and a
6. s or any other metal implement on bath surface Post installation clean up generally can be completed using warm water and liquid dishwashing detergent Stubborn dirt or stains may be removed using granular Spic and Span mixed with water Painter s naphtha can be used to remove excess adhesives and or wet oil base paint HARSH CHEMICALS SHOULD NEVER BE USED ON ACRYLIC SURFACES Abrasive cleaners must not be used since they will scratch and dull the surface Dulled areas can be restored by rubbing with a white automotive type polishing compound and waxing with a liquid wax 752352 100 REV F 4 SPIC AND SPAN IS A REGISTERED TRADEMARK OF PROCTER amp GAMBLE
7. third wire earth ground are essential ADDING THE SAFE T HEATER REQUIRES A SEPARATE 15 AMP MAXIMUM GFCI CIRCUIT ELECTRICAL INSTALLATION SEPARATE 15 AMP GFCI oi SEPARATE 20 AMP GFCI FOR 1 6HP MODELS FOR 2 1HP MODELS 120 VAC WHIRLPOOL MOUNTED AIR or ELECTRONIC SWITCH or WALL TIMER 1 6HP MODELS ONLY ELECTRICAL DIAGRAM READ AND FOLLOW ALL INSTRUCTIONS 752352 100 REV h 3 WIRE SELECTION GUIDE Maximum distance from _ Motor fusebox to motor The sizes shown on this Hi Performance chart are recommendations Rating f or copper conductors l oniv Alwavs follow 120V Power Line local and national electrical codes DRAIN CONNECTION AND SYSTEM TEST Using recommended drain opening connect whirlpool drain to waste line Tighten all drain joints securely Check the pump couplings and make sure they are hand tight Clean the whirlpool and fill with water to a point 2 above the top of the highest jet Recheck the pump couplings and make certain that they are not leaking Although the pump couplings are factory tightened and inspected some loosening may have occured during transit Make sure the whirlpool is connected to the electrical supply and turn the whirlpool on Check for leaks around all piping connections while the whirlpool is running POST INSTALLATION CLEAN UP Remove all construction debris from bath Tile grout can be removed with a wooden popsicle stick or tongue depressor Do not use wire brushe

Download Pdf Manuals

image

Related Search

Related Contents

USACE Levee Screening Tool application guide and user`s manual  USER MANUAL FOR THE BTD Control Software  Allegato 5 – Schede Macchine, Attrezzature e utensili  FERROLI ESPAÑA, S.A. - Ministerio de Hacienda  Acer Veriton VM4630G-SI748X PC  ASUS RT-AC66U C7415 User's Manual  りこの 「クイ ックスター トガイ ド」 では、 プロジェクター (本機) の基本的な  - University of Mississippi    HDRECS セットアップマニュアル  