American Power Conversion MXA001 User's Manual

image

Contents

1. 1L 120 208 Vac loads E 3000 VA model with MXA002 hard wire kit Each 120 Vac output 25 Amp maxi mum 208 Vac output 15 Amp maximum Total output not to exceed 3000 VA E 5000 VA model with MXA001 hard wire kit Each 120 Vac output 30 Amp maxi mum 208 Vac output 24 Amp maximum Total output not to exceed 5000 VA Limited Warranty American Power Conversion APC warrants its products to be free from defects in materials and workmanship for a period of two years from the date of purchase Its obligation under this warranty is limited to repairing or replacing at its own sole option any such defective products To obtain service under warranty you must obtain a Returned Material Authorization RMA number from APC or an APC service center Products must be returned to APC or an APC service center with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase This warranty does not apply to equipment which has been damaged by accident negligence or mis application or has been altered or modified in any way This warranty applies only to the original purchaser who must have properly registered the product within 10 days of purchase EXCEPT AS PROVIDED HEREIN AMERICAN POWER CONVERSION MAKES NO WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOS
2. and remove the appropriate knock out on the supplied input cable plate Page 5 3 0 Installation 3 3 Input wiring procedure continued To remove a knock out strike in the area shown with a nail set tool and hammer Grasp the edge of the knock out with pliers and twist until the knock out is separated from the plate Caution The edge of the knock out may be sharp Twist Remove Strike Example showing removal of 34 knock out 3 3 3 Remove all screws that secure the power distribution plate from the rear of the Isolation Unit Move the power distribution plate aside gently Take care not the strain the wires connected to the devices on the plate Input terminations block 4h P D ior ef 1 8 o FN ON E Qo 0 9 o Input cable plate 2O ho j Input cable Input cable connections Page 6 3 0 Installation 3 3 Input wiring procedure continued 3 3 4 Remove all three input cable wire connections from terminal block labeledL1 and L2 N 3 3 5 Remove all screws that secure the input cable plate Use a pair of wire cutters to remove tie wraps binding the input cable to wires inside the Isolation Unit Take care notto damage the insulation on any of the internal wires Remove the unneeded input cable plate and attached input cable 3 3 6 Fasten an appropriately sized and approved cable clamp not provided
3. onto the new input cable plate 3 3 7 Strip insulation from the input cable wire ends at the length given in Table 3 2 1 Table 3 2 1 3 3 8 Thread the input cable through the cable clamp and through the input cable plate hole in the Isolation Unit Arrange the cable so that the end is near the input terminations block 3 3 9 Putthe stripped wire end corresponding to the mains Line 1 into the terminations block terminal markedL1 and tighten the screw 3 3 10 Put the stripped wire end corresponding to the mains Protective Earth into the terminations block terminal marked and tighten the screw 3 3 11 Putthe stripped wire end corresponding tothe mains Line 2 into the terminations block terminal markedL2 N and tighten the screw 3 3 12 Check thatthere are no loose wire strands where applicable and that the terminations block screws are sufficiently tightened 3 3 13 Reattach the input cable plate and tighten the cable clamp Page 7 3 0 Installation 3 4 Output wiring procedure 3 4 1 Be sure the input circuit breaker is switched off 0 andthe input cable is unplugged and or has no power applied Caution Switching the circuit breaker to off 0 does not remove power to all of the Isolation Unit Power to the UPS must be disconnected at the source 3 4 2 If the unneeded power distribution plate is not already removed remove it now To remove the power distribution plate remove all screws that secure the plate from the rea
4. terminals to be permanently secured to building service wiring This kitis used in place of the power distribution plate and or input cable plate originally furnished with the UPS The kit contains input cable and output power distribution plates with knock outs for interface to standard sized fittings Hard wire kit parts Page 2 2 0 Presentation Power distribution plate Provides an interface for output hard wiring of loads It is used in place of the power distribution plate for cord connected equipment originally furnished with the UPS Input cable plate Used to replace the inputcable plate originally furnished with the UPS Itallows hard wiring of the input connections Wiring inspection cover When removed the wiring inspection cover reveals the output wiring connections tothe UPS Itis necessary to inspect the connections during installation as the wires may move when the power distribution plate is attached 4 Electrical fittings knock outs Knock outs appropriate for use with 1 2 output only 34 and 1 electrical cable clamp fittings are provided at the input cable plate and at the output power distribution plate UPS output power connector This self locking connector plugs into an internal receptacle The mating connector is revealed when the power distribution plate and top cover of the UPS Isolation Unit are removed The connector provides all necessary output voltages to the output
5. 1 7 93
6. E Some states do not permit limitation or exclusion of implied warranties therefore the aforesaid limitation s or exclusion s may not apply to the purchaser EXCEPT AS PROVIDED ABOVE IN NO EVENT WILL APC BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Specifically APC is not liable for any costs such as lost profits or revenue loss of equipment loss of use of equipment loss of software loss of data costs of substitutes claims by third parties or otherwise This warranty gives you specific legal rights and you may also have other rights which vary from state to state 2 Life Support Policy p a u ee As a general policy American Power Conversion APC does not recommend the use of any of its products in life support applications where failure or malfunction of the APC product can be reasonably expected to cause failure of the life support device or to significantly affect its safety or effectiveness APC does not recommend the use of any of its products in direct patient care APC will notknowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to APC that a the risks of injury or damage have been minimized b the customer assumes all such risks and c the liability of American Power Conversion is adequately protected under the circumstances Examples of devic
7. Installation 3 4 Output wiring procedure continued 3 4 9 Choose the desired wiring connections from the illustrations on the following pages Figure3 4 1 through Figure3 4 6 Insert the stripped wire ends into the appropriate output terminations block terminal and tighten the terminal screws Caution Overcurrent protection for output wiring is not provided The user must provide branch circuit protection of not more than 30 Amps for each line conductor Caution Where applicable output overcurrent protection for loads connected with wire rated for less than the maximum rated current of the UPS must be provided by the user 3 4 10 Once connections are made check that there are no loose wire strands where applicable and that the terminations block screws are sufficiently tightened 3 4 11 Use a 3 8 wrench to attach the earth bonding ring terminal on the new power distribution plate to the earthing stud on the Isolation Unit 3 4 12 Connect the new power distribution plate s UPS output power connector to its mate on the isolation unit 3 4 13 Attach the new power distribution plate to the Isolation Unit Take care not to force the plate into place and be sure that internal wires are not pinched 3 4 14 Reattach the Isolation Unit top cover and secure all screws 3 4 15 Check that the output wiring terminations are not strained and attach the wiring inspection cover 3 4 16 Follow the Start up instructions in the UPS Use
8. Matrix UPS Hard wire kit accessory MXAOO1 MXAOO2 B r B nos User s Manual American Power Conversion The world s most reliable power protection Important safety instructions Please read this manual Veuillez lire ce manuel Bitte lesen Sie dieses Anleitungshandbuch jSe ruega leer este manual de instrucciones PLEASE SAVE THIS MANUAL It includes important instructions for the safe use and installation of the UPS and its accessories CONSERVER CES INSTRUCTIONS Cette notice contient des instructions importantes concernant la s curit Entire contents copyright 1993 American Power Conversion All rights reserved reproduction in whole or in part without permission is prohibited Matrix UPS is a trademark of APC Table of contents 10 WAR GU CHOI sasse cosets ceacececentnesuncasiicnsibecunvisinceaarnmbescandddoennctonmaenenicd 2 20 PRESEN EAUON ca caicsssasscsdystcecuienssssenatalnsncasscadsbenmdussvoswoae tadeseasadetebeeiies 3 SO Installation ccssusesaticcsteneus dates oneied cnsaceepndenctednaustixesensdentisenseesendseaieis 4 CE VOlTASS Fe GUINSIIC IES mires a E S sat 4 Installation materials and tools c ssecnecres ohreciporieteeeene eae tees 4 PE WARIS POC SCG ssissssercsniisisesores sones dneni Erene KESET EErEE LEI PET EEn 5 COTO UE wiring MONOCOTS soei a E E E E E E E E 8 Page 1 1 0 Introduction The hard wire kit allows the UPS s input and or output
9. es considered to be life support devices are neonatal oxygen analyzers nerve stimulators whether used for anesthesia pain relief or other purposes autotransfusion devices blood pumps defibrillators arrhythmia detectors and alarms pacemakers hemodialysis systems peritoneal dialysis systems neonatal ventilator incubators ventilators for both adults and infants anesthesia ventilators and infusion pumps as well as any other devices designated as critical by the U S FDA Hospital grade wiring devices and leakage current may be ordered as options on many APC UPS systems APC does not claim that units with this modification are certified or listed as Hospital Grade by APC or any other organization Therefore these units do not meet the requirements for use in direct patient care Customer Service Note Before calling the customer service number please have available your UPS s serial number see the label at the rear of the UPS amp PHONE amp PHONE 800 800 4272 in USA Canada 33 1 64 62 59 00 in Europe 401 789 5735 world wide 401 789 5735 world wide lt MAILING lt MAILING American Power Conversion American Power Conversion 132 Fairgrounds Road 4 rue Ste Claire Deville P O Box 278 Zac du Mandinet Batiment Espace West Kingston Rhode Island LOGNES 02892 USA 77447 MARNE LA VALLEE C dex 2 FRANCE American Power Conversion The world s most reliable power protection 990 7012
10. r s Manual Page 10 3 0 Installation 3 4 Output wiring procedure continued Figure 3 4 1 1L 208 Vac loads only 3000 VA model with MXA002 hard wire kit 15 Amp maximum 5000 VA model with MXA001 hard wire kit 24 Amp maximum Figure 3 4 2 1L 240 Vac loads only 3000 VA model with MXA002 hard wire kit 12 5 Amp maximum 5000 VA model with MXA001 hard wire kit 21 Amp maximum Figure 3 4 3 Bio S O 1L 120 Vac loads only N boav 3000 VA model with MXA002 hard naola wire kit 25 Amp maximum 5000 VA model with MXA001 hard wire kit 30 Amp maximum Figure 3 4 4 1L 120 Vac loads only 3000 VA model with MXA002 hard wire kit 25 Amp maximum S L hend ian D 240V 5000 VA model with MXA001 hard Lono wire kit 30 Amp maximum Alternate of connection scheme shown in Figure 3 4 3 Page 11 3 0 Installation 3 4 Output wiring procedure continued 9 fe a 42 Lao a hipaa Page 12 Figure 3 4 5 1L 120 240 Vac loads E 3000 VA model with MXA002 hard wire kit Each 120 Vac output 25 Amp maxi mum 240 Vac output 1 2 5 Amp maximum Total output not to exceed 3000 VA E 5000 VA model with MXA001 hard wire kit Each 120 Vac output 30 Amp maxi mum 240 Vac output 21 Amp maximum Total output not to exceed 5000 VA Figure 3 4 6
11. r of the Isolation Unit Move the power distribution plate aside gently Take care not to strain the wires connected to the devices on the plate 3 4 3 Remove all screws securing the top cover plate to the Isolation Unit Liftoff the top cover plate Unmate the UPS output power connector attached at the end of the power distribution plate wire harness Isolation Unit top cover To unmate squeeze tabs and pull Unmating of UPS output power connector Page 8 3 0 Installation 3 4 Output wiring procedure continued 3 4 4 Use a 3 8 wrench to remove the protective earth wire green with yellow stripes ring terminal fastened at the earthing stud on the Isolation Unit Internal features not shown for clarity gt To power Earthing stud distribution Protective Earth wire plate Diagram showing power distribution plate earth connection 3 4 5 Remove the desired knock out from the new power distribution plate See the Input wiring procedure section 3 3 for instructions on how to remove the knock out 3 4 6 Fasten an appropriately sized and approved cable clamp not provided onto the power distribution plate 3 4 7 Strip insulation from the output cable wire ends at the length given in Table 3 2 1 Table 3 2 1 3 4 8 Thread the outputcable through the cable clamp and through the power distribution plate hole Arrange the cable so that the end is near the output termination block Page 9 3 0
12. rom a 240 Vac source the UPS must be reconfigured See the UPS User s Manual for instructions 3 2 Installation materials and tools 3 2 1 Required materials E Input and output electrical cable The UPS should be installed using approved 3 conductor flexible cable Recommended flexible cord sizes in units of American Wire Gauge and square millimeters and wire strip lengths are tabulated as follows Plan on leaving at least 3 3 ft 1 m of slack cable so that the UPS can be moved for maintenance or for the addition of new loads Page 4 3 0 Installation Table 3 2 1 Cable Size Strip Length UPS Model Minimum Maximum Input cable Output cable 2 5 mm2 10 0 mm2 6 0 mm2 10 0 mm2 1 2 3 8 S000 ME 10 AWG 8 AWG Cable clamps The UPS is not furnished with cable clamps for strain relief Use only approved 12 output only 34 or 1 fittings 3 2 2 Required tools E Electrician s pliers E Hammer o E Nail set or punch i E Flat blade screwdriver A A iF W Phillips screwdriver No 2 To E 3 8 Wrench J L lt W E Wire cutters 3 3 Input wiring procedure 3 3 1 Switch off 0 the UPS s input circuit breaker and unplug the input cord where applicable Caution Switching the input circuit breaker to off 0 does not remove power to all of the Isolation Unit Power to the UPS must be disconnected at the source 3 3 2 Determine the size of the electrical cable clamp fittings to be used either 34 or 1
13. wiring terminals 6 Earth bonding ring terminal The earth bonding ring terminal connects the output earthing terminations on the power distribution plate to the input protective earth This terminal is bolted to the Isolation Unit s earthing stud See the Installation section of this manual Page 3 3 0 Installation A E Warning Risk of electric shock exists inside the UPS Input voltage tap selection and power distribution panel replacement should be performed only by qualified service personnel E Avertissement Un risque de choc lectrique existe a l int rieur de UPS La s lection des fils de tension d entr e et le remplacement du panneau de distribution de puissance doivent tre effectu s seulement par du personnel d entretien et r parations qualifi E Warnung Im Inneren der unterbrechungsfreien Spannungsversorgung besteht die Gefahr des elektrischen Schlages Spannungswahl und Austausch der Verteilereinheit darf nur von qualifiziertem Servicepersonal durchgef hrt werden E Advertencia Dentro de la Fuente de Poder Ininterrumpible existe el riesgo de una descarga el ctrica Tanto la selecci n de las conexiones para el voltaje de entrada como el reemplazo del panel de distribuci n de potencia deben ser realizados por personal de servicio calificado 3 1 Input voltage requirements As furnished the UPS is configured to operate from a single phase 208 Vac source In applications where it is desired to operate f