Home
American Power Conversion AP9555 User's Manual
Contents
1. APC Power Distribution Unit AP9555 Installation Manual Contents Before you begin ssia 5 2 gt aka it n e Installation eeens a 2 rn Mounting options 4 Attach the mounting brackets 4 Attach the unit to the enclosure 5 Operation 28 a di a ne Specifications 2 2 m en Warranty Information o o ooooooomoo oo Limited warranty 9 Warranty limitations 9 Life Support PoliCY lt o 0000 eee eee 10 General policy 10 Examples of life support devices 10 Obtaining Service 0 000 i a eee 11 APC Worldwide Customer Support Before you begin Safety amp Please read the following information before installing or grounding operating your APC Power Distribution Unit PDU information This PDU is intended for indoor use only Do not install this PDU where excessive moisture or heat is present Never install any wiring equipment or PDUs during a lightning storm Plug this PDU into a three wire grounded power outlet only The power outlet must be connected to appropriate branch circuit mains protection fuse or circuit breaker Connection to any other type of power outlet may result in a shock hazard Use only the supplied brackets for mounting Do not use extension cords and adapters with this PDU Do not work alone under hazardous conditions Check that the power cord plug and socket are in good condition To reduce the risk of electric shock when grounding cannot
2. 1 69 x 17 0 x 4 00 in szex WKD 4 29 x 43 2 x 10 2 cm Weight 4 7 Ib 2 1 kg Shipping weight 5 9 lb 2 7 kg Environmental Elevation above MSL Operating 0 to 10 000 ft 0 to 3000 m Storage 0 to 50 000 ft 0 to 15 000 m Temperature Operating 32 to 113 F 0 to 45 C Storage 13 to 149 F 25 to 65 C Relative humidity Operating 0 to 95 non condensing Storage 0 to 95 non condensing Approvals Standards UL Warranty Information Limited warranty Warranty limitations American Power Conversion APC warrants the Power Distribution Unit to be free from defects in materials and workmanship for a period of two years from the date of purchase Its obligation under this warranty is limited to repairing or replacing at its own sole option any such defective products This warranty does not apply to equipment that has been damaged by accident negligence or misapplication or has been altered or modified in any way This warranty applies only to the original purchaser Except as provided herein American Power Conversion makes no watranties express or implied including warranties of merchantability and fitness for a particular purpose Some jurisdictions do not permit limitation or exclusion of implied warranties therefore the aforesaid limitation s or exclusion s may not apply to the purchaser Except as provided above in no event will APC be liable for
3. be verified disconnect the PDU from the power outlet before installing or connecting equipment Reconnect to the power outlet only after all connections are made Pluggable equipment includes a protective earth connector which carries the leakage current from the load devices computer equipment Do not exceed a total leakage current of 3 5 mA Installation Mounting This PDU was designed to be mounted in a variety of options orientations within an enclosure The mounting brackets included are equipped with multiple hole patterns that easily accommodate installation in a horizontal or vertical orientation Study the figures on this page and those on page 5 for mounting options Attach the 1 Decide which direction you would like the outlets to be mounting facing and orient the brackets appropriately brackets 2 Attach the rack mount brackets to the unit using four flat head Phillips screws provided for each bracket Vertical 1 Vertical 2 Continued on next page Installation continued Attach the unit 1 Choose a location for the unit and install four caged nuts to the provided with your enclosure in your chosen location enclosure Make sure that the caged nuts will line up with the mounting brackets that you have attached to the unit Note If you are installing your PDU on a NetShelter enclosure s vertical mounting rail install the caged nuts immediately above and below a notched hole on e
4. direct indirect special incidental or consequential damages arising out of the use of this product even if advised of the possibility of such damage Specifically APC is not liable for any costs such as lost profits or revenue loss of equipment loss of use of equipment loss of software loss of data costs of substitutes claims by third parties or otherwise This warranty gives you specific legal rights and you may also have other rights which vary from state to state Life Support Policy General policy Examples of life support devices 10 As a general policy American Power Conversion APC does not recommend the use of any of its products in life support applications where failure or malfunction of the APC product can be reasonably expected to cause failure of the life support device or to significantly affect its safety or effectiveness APC does not recommend the use of any of its products in direct patient care APC will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to APC that a the risks of injury or damage have been minimized b the customer assumes all such risks and c the liability of American Power Conversion is adequately protected under the circumstances The term life support device includes but is not limited to neonatal oxygen analyzers nerve stimulators whether used for anesthesia pain relief or other purposes autotrans
5. ach vertical rail 2 Align the mounting holes of the brackets with the installed caged nuts Insert screws and tighten Vertical 1 Vertical 2 Horizontal 1 ss dg Operation Overview Review the following figures and related descriptions to familiarize yourself with the components and the operation of your PDU Front View 1 Convenience Outlet Circuit Breaker The convenience outlet is always powered It provides power for various test equipment that is not normally part of the rack system The circuit breaker is tripped when the button is extended When it is tripped the PDU is overloaded and at least one piece of equipment needs to be unplugged The circuit breaker is rated to trip at the same overload as most home and office utility service branch protectors 20 A Operation continued Overview continued Rear View Outlets Plug Pull Out Guard Power Cord Ground stud Ten NEMA 5 15 outlets Use the guards to prevent cords from being accidentally disconnected from the outlets Five are provided 20A power cord 12 with a 5 20 straight plug 6 32 ground stud that can be used to ground the unit to the enclosure Specifications Product specifications Item Specification Power Input voltage range 100 125 V Maximum current draw 20A Physical
6. fusion devices blood pumps defibrillators arrhythmia detectors and alarms pacemakers hemodialysis systems peritoneal dialysis systems neonatal ventilator incubators ventilators for both adults and infants anesthesia ventilators infusion pumps and any other devices designated as critical by the U S FDA Hospital grade wiring and leakage current protection may be ordered as options on many APC UPS systems APC does not claim that units with these modifications are certified or listed as Hospital Grade by APC or any other organization Therefore these units do not meet the requirements for use in direct patient care Obtaining Service If problems If you are experiencing problems with your PDU that are not Persist covered in this manual or if problems with your PDU persist follow this procedure 1 Note the serial number and date of purchase of the Power Distribution Unit Contact Customer Support at a phone number or address on the back cover of this manual Be prepared to provide a description of the problem A technician will help solve the problem over the phone if possible or will give you a return material authorization RMA number If the Power Distribution Unit is under warranty repairs or replacement is free of charge If the warranty has expired there will be a charge for repair or replacement Pack the Power Distribution Unit carefully to avoid damage in transit Damage sustained in
7. ort contact for contact information e Contact the APC representative or other distributor from whom you pur chased your APC product for information on how to obtain local customer support Entire contents copyright 2000 American Power Conversion All rights reserved Reproduction in whole or in part without permission is prohibited APC is a registered trademark of American Power Conversion Corporation All other trademarks product names and corporate names are the property of their respective owners and are used for informational purposes only 990 6038A 01 2001
8. transit is not covered under the warranty Enclose a letter in the package with your name address RMA number a copy of the sales receipt daytime phone number and check if applicable Mark the RMA number clearly on the outside of the shipping carton The factory will not accept any materials without this marking Return the Power Distribution Unit by insured prepaid carrier to the address provided by the Customer Support technician www apcc com APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways e Visit the APC Web site to find answers to frequently asked questions FAQs to access documents in the APC Knowledge Base and to submit customer support requests http www apcec com Corporate Headquarters Connect by links to APC Web pages for specific countries and regions each of which provides customer support information http www apcc com support Submit customer support requests e Contact an APC Customer Support center by telephone or e mail Regional centers APC Headquarters U S and Canada 1 800 800 4272 toll free 1 401 789 5735 United States Latin America apctchla apcc com Europe Middle East 353 91 702020 Ireland Africa apceurtech apcc com 03 5434 2021 Japan jsupport apcc com Local country specific centers go to http www apcc com supp
Download Pdf Manuals
Related Search
Related Contents
Maytag MTW5800TW0 User's Manual RC-189U_manuale Manuel d`installation, d`utilisation et d`entretien GAHP-A Hotpoint RZ00 User's Manual G.F. 4 Jet Lift CLAMP-ON METER User Manual E N G L I S H Ejemplos: a. Los arqueólogos llegaron a Dzibanché Ace Waypoint User Manual Fostex D-15 DVR User Manual Copyright © All rights reserved.
Failed to retrieve file