1. will occur Heater Fault Routine continued After the initial 15 second time difference monitoring routine the PLC will then continue to monitor the HEAT ON GAS VALVE STATUS for any malfunction of either the front or rear burners If the heat signal is asserted and either or both gas valves are not ignited HEATER FAULT will occur During a HEATER FAULT the following will occur The END OF CYCLE light will begin to flash The HEATER FAULT RESET BUTTON will begin to flash The fan and tumbler will run a COOL DOWN CYCLE for two 2 minutes IMPORTANT A HEATER FAULT indicates that there is a problem with one or both burners not igniting properly HEATER FAULT errors are caused by Exhaust hi limit switch open Front or rear burner hi limit switch open Front or rear burner air flow switch open Either no front or rear flame being sensed by their respective flame probes caused by either no spark faulty flame probe faulty Direct Spark Ignition DSI module or bad gas valve HEATER FAULT RESET The heater fault reset button s warning light will flash at a rate of once per second Once the reset button is pressed the following will occur The END OF CYCLE and HEATER FAULT lights will stop flashing The Phase 5 keyboard will respond to keystroke inputs providing the machine lint drawer and load doors are closed NOTE If HEATER FAULTS continue t
2. a drying cycle has been completed the tumbler can be loaded in the level position or either unloaded in the level position or in the forward tilt position Rear Up LOAD or UNLOAD LEVEL Open the front doors and load or unload the tumbler NOTE The forward or reverse jog functions do not work in the level position UNLOAD TILTED Select 1 on the 0 UNLOAD 1 selector switch located on the right front control door and fully open both load doors The tumbler will tilt forward Rear Up Once 1 has been selected on the 0 UNLOAD D 11 selector switch the forward and reverse jog functions will become operational To level the machine from a forward tilt position select 0 on the 0 UNLOAD 1 selector switch The jog functions will become non operational and the tumbler will tilt towards the rear to the level position NOTE There is a four 4 second dwell stop time between a forward and a reverse selection to prevent plug starting the drive motor LINE Gas Models ONLY _ During a drying cycle the PLC monitors the status of the Phase 5 s Heat On Off signal and the signals of the front and rear burner controllers to their respective gas valve Heater Fault Routine At the start of every HEAT ON signal of the Phase 5 computer the PLC monitors the time between the HEAT ON and GAS VALVE ON signals If the time between these two 2 signals is greater than 15 seconds a HEATER FAULT
3. WARNING For your safety the AVERTISSEMENT Assurez vous de bien information in this manual must be suivre les instructions donn es dans cette followed to minimize the risk of fire or notice pour r duire au minimum le risque explosion or to prevent property damage d incendie ou d explosion ou pour eviter tout personal injury or death dommage mat riel toute blessure ou la mort Do not store or use gasoline or other flammable Ne pas entreposer ni utiliserd essenceni vapor and liquids in the vicinity of this or any d autres vapeurs ou liquides inflammables dans other appliance le voisinage de cet appareil ou de tout autre appareil WHAT DO YOU DO IF YOU SMELL GAS QUE FAIRE SI VOUS SENTEZ UNE ODEUR Do not try to light any appliance DE GAZ Do not touch any electrical switch do not use any phone in your building Ne pastenter d allumer d appareil Clear the room building or area of all Ne toucheza aucun interrupteur Ne pas occupants vous servir des t l phones se trouvant dans Immediately call your gas supplier froma le b timent o vous vous trouvez neighbor s phone Follow the gas supplier s Evacuezla pi ce le b timent ou la zone instructions Appelez imm diatement votre fournisseur de If you cannot reach your gas supplier call the gaz depuis un voisin Suivez les instructions fire department du fournisseur Si vous ne pouvez rejoindre le fournisseur Installation and service must be perfo
4. al as complete as possible and hope you will find it useful ADC reserves the right to make changes from time to time without notice or obligation in prices specifications colors and material and to change or discontinue models Important For your convenience log the following information DATE OF PURCHASE MODEL NO ADG 310 DISTRIBUTORS NAME Serial Number s Replacement parts can be obtained from your distributor or the ADC factory When ordering replacement parts from the factory you can FAX your order to ADC at 508 678 9447 or telephone your orders directly to the ADC Parts Department at 508 678 9000 Please specify the dryer model number and serial number in addition to the description and part number so that your order is processed accurately and promptly IMPORTANT NOTE TO PURCHASER Information must be obtained from your local gas supplier on the instructions to be followed if the user smells gas These instructions must be posted in a prominent location near the dryer ADG 310 Forward Tilt Manual Door with Heater Fault Indication MACHINE OPERATION SUMMARY This AD 310 incorporates one 1 emergency stop button located on the right front of the machine This button is TURN TO RELEASE and must be in the released mode to power the machine When the emergency button is released the Phase 5 micro computer s display will light To turn on the AD 310 s control voltage press the green ON butto
5. n located on the right front control panel NOTE If a Sprinkler System is incorporated in the machine the Sprinkler System must be Ten e the control power to engage Refer to the AD 310 endum ADC Part No 112233 for sprinkler HERE a SS The ADG 310 has two 2 electronic controllers Phase 5 micro computer for material drying Micro 1 PLC Programmable Logic Controller for burner status monitoring end of cycle light control forward tilt and jog functions The Phase 5 micro computer responds to keypad commands only when the AD 3107s doors and lint screen drawer are both closed The Micro 1 PLC Programmable Logic Controller monitors burner status during a drying cycle and stops the drying cycle if any fault is detected with the burners It also controls the FORWARD TILT Rear Up and LEVEL Rear Down functions of the AGD 310 s tumbler section in addition to forward and reverse tumbler manual jog selections ADG 510 DETAIL OPERATION INFORMATION Anytime the airjet signal is asserted the END OF CYCLE light located on the top of the tumbler section will begin to flash once a second and remain on until the LOAD DOORS are opened If the ADG 310 s load doors are open during a cycle the cycle will stop Likewise when the load doors are closed again the current drying cycle can be restarted by pressing the START button on the Phase 5 keypad LOADING or UNLOADING THE MACHINE Once
6. o occur troubleshooting of the heater section will be required Refer to the system ladder diagram for heater signal information ADC 112135 1 08 02 95 10 2 08 25 95 2 3 12 14 95 10 TEZ American Dryer Corp 4 03 04 96 10 5 04 02 96 25 6 05 25 99 10 al
7. rmed by a de gaz appelez le service des incendies qualified installer service agency or the gas supplier L installation et l entretien doivent tre assur s par un installateur ou un service d entretien qualifi ou par le fournisseur de gaz For replacement parts contact the distributor from which the dryer was purchased or American Dryer Corporation American Dryer Corp 88 Currant Road Fall River MA 02720 4781 Telephone 508 678 9000 Fax 508 678 9447 e mail techsupport amdry com 080395 ADC Part No 112235 Retain This Manual In A Safe Place For Future Reference American Dryer Corporation products embody advanced concepts in engineering design and safety If this product is properly maintained it will provide many years of safe efficient and trouble free operation ONLY qualified technicians should service this equipment OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment or specified in the installation operator s manual included with the dryer The following FOR YOUR SAFETY caution must be posted near the dryer in a prominent location FOR YOUR SAFETY POUR VOTRE S CURIT Do not store or use gasoline or Ne pas entreposer ni utiliser d essence other flammable vapors or liquids ni d autres vapeurs ou liquides in the vicinity of this or any other inflammables dans le voisinage de cet appliance appareil ou de yout autre appareil We have tried to make this manu
Download Pdf Manuals
Related Search
Related Contents
Powerflex 700H Kurzanleitung Emerson MS Motor Starters Certificate 高天井用LED照明ユニット - LED STYLE|スタンレー電気株式会社 01-no2(English)H10D,H21D procedure for recovering a corrupt bios chip ! G-DEC_069437b.qxd Untitled Instrucciones 95-5616 - Detector Electronics Corporation. ATOUT+3 Le concours d`entrée en Bachelor Copyright © All rights reserved.