Home

Amana NED5800DW Dimension Guide

image

Contents

1. m Companion appliance spacing should also be considered 04 2014 ELECTRICAL REQUIREMENTS To supply the required 3 or 4 wire single phase 120 240 volt 60 Hz AC only electrical supply or 3 or 4 wire 120 208 volt electrical supply if specified on the serial rating plate on a separate 30 amp circuit fused on both sides of the line A time delay fuse or circuit breaker is recommended Connect to an individual branch circuit VENTING REQUIREMENTS Exhaust venting Exhaust your dryer to the outside 4 102 mm The Vent System Chart provides venting requirements that will diameter vent is required Rigid or flexible metal exhaust vent help achieve best drying performance must be used Do not use plastic or metal foil vet Exhaust hood must be at least 12 305 mm from the ground or any object that Standard Vent System Chart _ may be in the path of the exhaust Standard Vent System Chart Number of Type Angled Exhaust hoods 90 elbows of vent hoods Ooo Rigid metal 64 ft 20 m a Rigid metal 54 ft 16 5 m TA c2 i Rigid metal 44 ft 13 4 m Recommended Styles Rigid metal 35 ft 10 7 m Rigid metal 27 ft 8 2 m Louvered Hood Box Hood Acceptable Style NOTE Bottom exhaust installations have a 90 turn inside the dryer To determine maximum exhaust length add one 90 turn ain to the chart Angled Hood Determine vent path Select route that will provide straightest and most direct path outdoors E Plan install
2. ation to use fewest number of elbows and turns m When using elbows or making turns allow as much room as possible E Bend vent gradually to avoid kinking m Use as few 90 turns as possible Determine vent length and elbows needed for best drying performance E Use following Vent System Chart to determine type of vent material and hood combinations acceptable to use NOTE Do not use vent runs longer than those specified in Vent System Chart Exhaust systems longer than those specified will E Shorten life of dryer m Reduce performance resulting in longer drying times and increased energy usage Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only For complete details see Installation our products we reserve the right to change materials and specifications without notice Instructions packed with product Specifications subject to change without notice
3. d Electric Dryer f a L a PRODUCT MODEL NUMBERS NED5700B NED5800D Front view Side view lt q 27 _p 686 mm 383 4 Min 984 mm 39 Max 53 4 990 mm 146 mm 31 2 89 mm Back view 3 q 101 e lt e 61 2 18 mm 257 mm 165 mm Recommended installation clearances dryer only NOTE Most installations require a minimum of 5 127 mm Power supply cord cable i 297 8 erie eerie Water inlets 759 mm Yer TOL enna steam models 18 min 76 mm vent with elbow 48 in min 2 on y 31 2 457 mm 310 2 See Venting 89 mim 310 cm Requirements 24 in min 3 4 a 1 Se rin nx 1 55 cm 18 mm iae 127 mm 76 mm 365 mm j Approx measurement n aig 1 E z 25 mm 25 mm Installation spacing for recessed area or closet installation 0 0 mm spacing is allowed All dimensions show recommended and minimum spacing allowed m Additional spacing should be considered for ease of installation and servicing m Additional clearances might be required for wall door floor moldings and dryer venting E Additional spacing should be considered on all sides of the dryer to reduce noise transfer E For closet installation with a door minimum ventilation openings in the top and bottom of the door are required Louvered doors with equivalent ventilation openings are acceptable W10573709B

Download Pdf Manuals

image

Related Search

Related Contents

Electro-Voice EVX-156 User's Manual  Sikaflex 291i mini recharge    warning danger bellagio commercial gas patio heater pth31gt    

Copyright © All rights reserved.
Failed to retrieve file