Home
Amana AGR5630BDS Dimension Guide
Contents
1. PRODUCT DIMENSIONS a A 27 7 70 8 cm max depth with handle B 36 91 4 cm cooktop height max with leveling legs screwed all the way in C 46 7 119 1 cm overall height max with leveling legs screwed all the way in D 29 7 75 9 cm width E 25 6 64 6 cm depth Back of range to front of cooktop F Model serial rating plate located on the oven frame behind the top left side of the oven door IMPORTANT Range must be level after installation Follow the instructions in the Level Range section Using the cooktop as a reference for leveling the range is not recommended Range can be raised approximately 1 2 5 cm by adjusting the leveling legs Front of door and drawer may extend further forward depending on styling Page 1 of 2 Dimensions are for planning purposes only For complete details see Installation Ref W10526974A Our products we reserve the right to change materials and specifications without notice Instructions packed with product Specifications subject to change without notice 3 12 14 CABINET OPENING DIMENSIONS Cabinet opening dimensions shown are for 25 64 0 cm countertop depth 24 61 0 cm base cabinet depth and 36 91 4 cm countertop height Ds S IMPORTANT If installing a range hood or microwave hood combination above the range follow the range hood or microwave hood combination installation instructions le for dimensional clearances above the
2. Pipe joint compounds that resist the action of LP gas must be used Do not use TEFLON tape Flexible metal appliance connector e f local codes permit a new CSA design certified 4 to 5 ft 122 to 152 4 cm long 12 1 3 cm or 3 4 1 9 cm I D flexible metal appliance connector may be used for connecting range to the gas supply line a A 1 2 1 3 cm male pipe thread is needed for connection to the female pipe threads of the inlet to the appliance pressure regulator Do not kink or damage the flexible metal tubing when moving the range Rigid pipe connection The rigid pipe connection requires a combination of pipe fittings to obtain an in line connection to the range The rigid pipe must be level with the range connection All strains must be removed from the supply and fuel lines so range will be level and in line e Must include a shutoff valve The supply line must be equipped with a manual shutoff valve This valve Should be located in the same room but external to the range opening such as an adjacent cabinet It should be in a location that allows ease of opening and closing Do not block access to shutoff valve The valve is for turning on or shutting off gas to the range A Gas supply line B Shutoff valve open position C To range TEFLON is a registered trademark of E l Du Pont De Nemours and Company Because Whirlpool Corporation policy includes a continuous commitment to improve
3. cooktop surface Iw A 18 45 7 cm upper side cabinet to countertop A X B 13 33 cm max upper cabinet depth E WN C 30 76 2 cm min opening width A D For minimum clearance to top of cooktop see NOTE N E 30 76 5 cm min opening width M F The shaded areas are recommended for installation of rigid gas pipe G 4 3 11 4 cm ee H 8 20 3 cm l 17 43 2 cm oS J 2 5 1 cm K 43 11 4 cm _ J L 2 5 1 cm min clearance from both sides of range to side D wall or other combustible material K M Grounded outlet N N Cabinet door or hinges should not extend into the cutout NOTE 24 61 0 cm minimum when bottom of wood or metal cabinet is covered by not less than 1 4 0 64 cm flame retardant millboard covered with not less than No 28 MSG sheet steel 0 015 0 4 mm stainless steel 0 024 0 6 mm aluminum or 0 020 0 5 mm copper 30 76 2 cm minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet Page 2 of 2 Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only For complete details see Installation Ref W10526974A our products we reserve the right to change materials and specifications without notice Instructions packed with product Specifications subject to change without notice 3 12 14
4. Amana 30 76 2 cm Freestanding Gas Range PRODUCT MODEL NUMBERS AGR5630BD AGR5844VD Electrical Requirements A 120 volt 60 Hz AC only 15 amp fused electrical circuit is required A time delay fuse or circuit breaker is also recommended It is recommended that a Separate circuit serving only this range be provided Gas Supply Requirements Type of gas Natural gas This range is design certified by CSA International for use with Natural gas or after proper conversion for use with LP gas e This range is factory set for use with Natural gas See Gas Conversions section The model serial rating plate located on the oven frame behind the top left side of the oven door has information on the types of gas that can be used If the types of gas listed do not include the type of gas available check with the local gas supplier LP gas conversion Conversion must be done by a qualified service technician No attempt shall be made to convert the appliance from the gas specified on the model serial rating plate for use with a different gas without consulting the serving gas Supplier See Gas Conversions section Gas Supply Line e Provide a gas supply line of 34 1 9 cm rigid pipe to the range location A Smaller size pipe on longer runs may result in insufficient gas supply With LP gas piping or tubing size can be 1 2 1 3 cm minimum Usually LP gas Suppliers determine the size and materials used in the system NOTE
Download Pdf Manuals
Related Search
Related Contents
Lenovo ThinkPad X121e Leaflet 55PUS8909C_12 Released Spain (Spanish) High Atmel AVR2043: REB231ED - Hardware User manual 8 DOOR SENSOR WITH AUTO NOTIFICATION Télécharger Hitachi 50C10E Projection Television User Manual VPAP™ Adapt H5i™ ClimateLine™ / ClimateLineMAX Sony SNC-CH160 - Network Webcams Bulletin Municipal 2013 - Communauté de Communes du Porhoët Copyright © All rights reserved.
Failed to retrieve file