1. current equipment such as a lighting or air conditioning system is fed from the same power source as the display equipment TROUBLESHOOTING GUIDE 10 We have carefully tested and have found no problems in the supplied DA1913GL unit however we would like to offer the following suggestions Please make sure that input amplitude level is as follows 1 Analog signal is less than 1 5V 2 Sync signal is less than 0 3V Please use Altinex supplied external power Supply AC Adapter 9V 500mA only Please check settings of Sync Level Video Level and Input Termination Switches Please make sure that proper quality of cables is used We recommend Altinex made cables for best results If the problem shows up after continuous usage at higher voltage higher temperature higher humidity or at other extreme environmental conditions please correct that the problem ALTINEX POLICY 11 11 1 LIMITED WARRANTY Altinex warrants that its products and cables are free from defects in materials under normal use and service This warranty is limited to repairing at company s factory any part or parts of the product which upon company s examination shall disclose to be thus defective Products considered defective should be returned to company with transportation charges pre paid within 2 years 90 days for cables from date of shipment to the purchaser The warranty is expressly instead of all other warranties expre
2. 2 GENERAD 2 RACK MOUNT SAFETY GUIDELINES 2 INSTALLATION 2 icm t 2 FCC CE NOTICE 2 ABOUT YOUR DISTRIBUTION AMPLIFIER 3 TECHNICAL SPECIFICATION 3 DESCRIPTION OF DA1913GL 4 MOUNTING THE DA1913GL 4 APPLICATION DIAGRAM 5 INSTALLING YOUR DISTRIBUTION AMPLIFIER OPERATION isch hates nU 5 ACCESSORIES 6 FREQUENTLY ASKED QUESTIONS 4 6 TROUBLESHOOTING GUIDE 7 ALTINEX POLICE 7 LIMITED WARRANTY sicnt tkt 7 RETURN POLICY iiie tertiis 7 CONTACT INFORMATION 7 Tel 714 990 2300 Toll Free 1 800 ALTINEX FAX 714 990 3303 E mail solutions altinex com Web www altinex com DISTRIBUTION AMPLIFIERS PRECAUTIONS SAFETY WARNINGS L Please read this manual carefully before using your DA1913GL Distribution Amplifier Keep this manual handy for future reference These safety instructions are to ensure the long life of your DA1913GL and to prevent fire and shock hazard Please read them carefully and heed all warnings 1 1 GENERAL Unauthorized personnel sha
3. simultaneously 2 Can use the Compensation for cable loss is automatically made for a distance of 100 feet though the DA1913GL can drive signals through longer runs depending on the source signal resolution and cable quality It is not recommended since one power supply is supplied with each unit Please consider the PS5581SM a rack mount power supply 3 Are outputs 1 amp 2 The DA1913GL has two mode range of the DA1913GL and why is it so important buffered individually buffered outputs 4 What is common The common mode range of the DA1913GL Distribution Amplifier is 2V with a video signal of 1V p p In most cases a ground loop voltage will not exceed 200 300mV so this range is more than enough to handle even the most severe ground loop problems 5 How will the DA1913GL provide protection from a ground loop in the system A ground loop is a type of electromagnetic interference often caused by small but significant differences in ground voltage between two or more different power sources when equipment using the different power sources is connected by means of video audio inputs and outputs A ground loop may also be caused when high ALTINEX SIGNAL MANAGEMENT SOLUTIONS Tel 714 990 2300 Toll Free 1 800 ALTINEX FAX 714 990 3303 E mail solutions altinex com Web www altinex com DISTRIBUTION AMPLIFIERS
4. S Video Y C The DA1913GL Distribution Amplifier is a state of the art product with a video bandwidth of 350 MHz enabling it to remain transparent to the video signal passing through it Each output is individually buffered and is not affected by other output loading The common mode range of the DA1913GL Distribution Amplifier is 2 Volts with a video signal of 1 Volt p p In most cases a ground loop voltage will not exceed 200 300mv so this range is more than enough to handle even the most severe ground loop problems TECHNICAL SPECIFICATIONS 3 FEATURES DESCRIPTION DA1913GL GENERAL Inputs 1 Input Connector 4 BNC Female Outputs 2 Output Connectors Two4 BNC Female Compatibility High resolution RGBS RGsB and RsGsBs Component S Video and Composite Video Table 1 DA1913GL General and Composite Video by using the appropriate MECHANICAL DA1913GL channels The DA1913GL can pass C Video and Material 0 1 AI S Video simultaneously by using Red for C Video Finish and Green Blue for Chroma Luma respectively Top Panel Lexan The DA1913GL is typically used for permanent Height inches 3 50in 89mm installation and is supplied with a 12 inch power Width inches 4 56in 116mm cable with bare leads requiring the connection of Depth inches 0 94in 24mm 9V 500mA DC power The DA1913GL does not Weigh
5. A number may experience a delay in service The service charges will be quoted to you before the actual repairs are done 11 3 CONTACT INFORMATION Sales Department Phone 714 990 2300 Fax 714 990 3303 Accounting Department Phone 714 990 6088 Fax 714 990 5778 ALTINEX Tel 714 990 2300 Toll Free 1 800 ALTINEX FAX 714 990 3303 E mail solutions altinex com Web www altinex com SIGNAL MANAGEMENT SOLUTIONS
6. DISTRIBUTION AMPLIFIERS OX 4 2e SAL AGES MTION AMPLIFIER FCC Class Serial N 1344 IN Con ce oW owe MANUAL PART NUMBER 400 0038 003 PRODUCT REVISION 0 DA1913GL 1 IN 2 OUT RGBS DISTRIBUTION AMPLIFIER USER S GUIDE e ZALTINEX C Tel 714 990 2300 Toll Free 1 800 ALTINEX FAX 714 990 3303 E mail solutions altinex com Web www altinex com gs DISTRIBUTION AMPLIFIERS INTRODUCTION Thank you for purchasing DA1913GL Distribution Amplifier We are sure you will find it a reliable and useful product Superior performance for the right price backed by solid technical and customer support is what we have to offer The product you are holding in your hands is designed using state of the art technology and is superior to anything available on the market You will find this and our other products reliable long lasting and simple to operate We are committed to providing our customers with solutions to the most demanding audio visual installations at very competitive pricing We appreciate your selection of our products and are confident that you will join the ranks of our many satisfied customers throughout the world This manual covers DA1913GL 1 in 2 out RGBS Distribution Amplifier with Ground Loop Isolation ALTINEX TABLE OF CONTENTS Page PRECAUTIONS SAFETY WARNINGS
7. ach step is completed the unit should now be fully operational Step 1 Make sure that the proper power supply is being used with the unit The use of an incorrect power supply covered by warranty Step 2 Connect the power supply to the unit 1 800 258 4623 or 1 714 990 2300 for The power indicator LED on the front international calls panel will light This indicates that the unit is operational OPERATION 7 Step 3 Connect the high resolution RGsB or If you experience any problems please call RGBS source to the DA1913GL using The DA1913GL will operate successfully as long coaxial cables with BNC connectors while as cables are attached properly and other making sure that the colors match specifications are followed There are no other correctly Then connect one or two adjustments necessary to operate the unit monitors or projectors to the output s of the DA1913GL The monitors or projectors must be scan rate compatible with the source signal resolution The DA1913GL does not affect the scan rate Step 4 If the image is less than perfect check all the connections The unit is very reliable and seldom will this be the cause of malfunction Poor quality cables may MANAGEMENT SOLUTIONS ALTINEX Tel 714 990 2300 Toll Free 1 800 ALTINEX FAX 714 990 3303 E mail solutions altinex com Web www altinex com DISTRIBUTION AMPLIFIERS ACCESSORIES 8 Model No Descript
8. case the user will be required to correct the interference at his own expense ALTINEX Tel 714 990 2300 Toll Free 1 800 ALTINEX FAX 714 990 3303 E mail solutions altinex com Web www altinex com SIGNAL MANAGEMENT SOLUTIONS DISTRIBUTION AMPLIFIERS e Any changes or modifications to the unit not expressly approved by Altinex Inc could void the user s authority to operate the equipment ABOUT YOUR DISTRIBUTION AMPLIFIER 2 The DA1913GL is a 1 in 2 out RGBS distribution amplifier designed to allow the connection of a single computer or interface source to one or two monitors or projectors The DA1913GL also provides ground loop isolation through the use of differential inputs with a common mode rejection of 2 0V making it perfect for applications with challenging power supply scenarios A ground loop is a type of electromagnetic interference often caused by small but significant differences in ground voltage between two or more different power sources when equipment using the different power sources is connected by means of video audio inputs and outputs A ground loop may also be caused when high current equipment such as a lighting or air conditioning system is fed from the same power source as the display equipment Though primarily designed to pass an RGBS signal format through 4 BNC connectors for each input output the DA1913GL can also pass RGsB Component Video Y R Y B Y
9. h 1 4 bare leads on the end 75 Ohms 4 2 MOUNTING THE DA1913GL TTL To mount the DA1913GL Altinex offers L shape 0 3V mini brackets DA1295SX which provide wings on 22 Ohms either side of the unit allowing it to be installed on a rack plate furniture or a wall 15 200 kHz 47 180Hz 350 MHz 3dB 380 MHz 3dB Common Mode Rejection 2V w signal of 1V Coupling Cross talk 40dB 10MHz Power External Power Adapter AC Power Consumption Table 3 DA1913GL Electrical DESCRIPTION OF DA1913GL 4 INPUT G R RGBS VIDEO 9V 500 mA POWER INDICATOR POWER INPUT OUTPUT2 POWER SOM DISTRIBUTION AMPLIFIER DA1913GL Rev 0 SN 12345 HARD WIRED POWER CABLE TO BARE LEADS RGBS INPUT RGBS OUTPUT No 2 RGBS OUTPUT No 1 MODEL SERIAL No REVISION ALTINEX R Q Z gt aea MANAGEMENT SOLUTIONS Tel 714 990 2300 Toll Free 1 800 ALTINEX FAX 714 990 3303 E mail solutions altinex com Web www altinex com DISTRIBUTION AMPLIFIERS APPLICATION DIAGRAM 5 D 833388 COMPUTER INTERFACE VIDEO SOURCE MULTI CHANNEL COAX CABLE DA1913GL DISPLAY MULTI CHANNEL COAX CABLE DISPLAY degrade the performance of the product INSTALLING YOUR DISTRIBUTION Make sure that the cables used AMPLIFIER 6 are coaxial cables and that all pins are in good condition After e
10. ion RACK MOUNTING BRACKETS DA1295SX lRack Wall Furniture Mount Mini brackets 2 L shaped brackets POWER SUPPLIES PS5502US 9 500 Power Supply for US PS5512UK 9V 500mA Power Supply for UK PS5522AU 9 500mA Power Supply for Australia PS5532GR 9V 500mA Power Supply for Germany PS5542JP 9V 500mA Power Supply for Japan 4 BNC to 4 BNC COAXIAL CABLE CB4100MR Bulk Cable 4 coaxes 500ft minimum 4103 3 feet 4 BNC to 4 BNC coaxial cable 4106 6 feet 4 BNC to 4 BNC coaxial cable CB4112MR 12 feet 4 BNC to 4 BNC coaxial cable 4125 25 feet 4 BNC to 4 BNC coaxial cable 4150 50 feet 4 BNC to 4 BNC coaxial cable 4175 75 feet 4 BNC to 4 BNC coaxial cable CB41100MR 100 feet 4 BNC to 4 BNC coaxial cable CB41150MR 150 feet 4 BNC to 4 BNC coaxial cable 4 BNC to 4 BNC COAX Super High Resolution CB4300MR Bulk Cable 4 coaxes 500ft minimum CB4306MR 6 feet 4 BNC to 4 BNC coaxial cable CB4312MR 12 feet 4 BNC to 4 BNC coaxial cable CB4325MR 25 feet 4 BNC to 4 BNC coaxial cable 4350 50 feet 4 BNC to 4 BNC coaxial cable 4375 75 feet 4 BNC to 4 BNC coaxial cable CB43100MR 100 feet 4 BNC to 4 BNC coaxial cable FREQUENTLY ASKED QUESTIONS 9 No Question Answer 1 What is the maximum length of cable that can be used with the DA1913GL DA1913GL power supply to power 2 units
11. ll not open the unit since there are high voltage components inside Qualified Altinex service personnel or their authorized representatives must perform all service 1 2 SAFETY GUIDELINES FOR THE RACK MOUNTING OF THE DA1913GL Maximum operating ambient temperature is 35 degrees C Never restrict the air flow through the devices fan or vents When installing equipment into a rack distribute the units evenly Otherwise hazardous conditions may be created by an uneven weight distribution Connect the unit to a properly rated supply circuit Reliable Earthing Grounding of Rack Mounted Equipment should be maintained 1 3 INSTALLATION For best results place the DA1913GL Distribution Amplifier on a flat level surface in a dry area away from dust and moisture To prevent fire or shock do not expose this unit to rain or moisture Do not place the DA1913GL Distribution Amplifier in direct sunlight near heaters or heat radiating appliances or near any liquid Exposure to direct sunlight smoke or steam can harm internal components Handle the DA1913GL Distribution Amplifier carefully Dropping or jarring can damage internal components Do not place heavy objects on top of the DA1913GL If the DA1913GL is to be mounted to a table or wall use only Altinex made mounting accessories like mini mount bracket DA1295FC and cables for optimum setup To turn off the main power be sure to remove the cord from p
12. ower outlet The power outlet socket should be installed as near to the equipment as possible and should be easily accessible Do not pull power cord or any cable that is attached to the DA1913GL Distribution Amplifier If the DA1913GL Distribution Amplifier is not to be used for an extended period of time disconnect the power cord from the power outlet 1 4 CLEANING Unplug the DA1913GL power cord before cleaning Clean surfaces with a dry cloth Never use strong detergents or solvents such as alcohol or thinner Do not use a wet cloth or water to clean the unit 1 5 FCC CE NOTICE This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which
13. ssed or implied Altinex neither assumes nor authorizes any other person to assume for it any other liability in connection with the sale of the products This warranty shall not apply to any product that shall have been repaired or altered outside of company s factory in any way so as in its judgment to affect its stability or reliability or that has been subject to misuse negligence or accident 11 2 RETURN POLICY It is very important that you receive product that you have ordered and that this product fulfills your need In the unlikely event that an Altinex product needs to be returned please follow the procedure below Altinex will accept product returns for a period of 30 days from authorized Altinex dealers Products must be returned in an unopened package If product has been opened the restocking fees will apply For the restocking fee amount please contact an Altinex Sales Representative If product is in your possession for more than 30 days the restocking fees will apply Altinex will not accept any returns on cables or custom products If your product is in warranty and needs service contact the Altinex Sales Department for an RMA Return Material Authorization Products returned without an RMA number may experience a delay in service If your product is out of warranty and needs service contact the Altinex Sales Department for an RMA Return Material Authorization Products returned without an RM
14. t pounds 0 6lbs 0 27kg come with a power adapter it has to be wired to a Ship Weight pounds 2 0lbs 0 91kg power source using the bare leads T Operating 10 C 35 C The DA1913GL is extremely compact allowing it to T Maximum 50 C fit nicely into tight spots It may also be mounted to Humidity 90 non condensing almost any surface using optional L type mini MTBF calculations 40 000 hrs brackets Table 2 DA1913GL Mechanical Note A power adapter for the DA1913GL must be ELECTRICAL DA1913GL ordered separately if required In the United Input Video Signal States the PS5502US Power Adapter can be Analog Signal 1 5V p p max used though the connector must be cut off to allow Impedance 75 Ohms interconnection Input Sync Signal Horizontal Vertical amp C Sync TTL ZALTINEX L5 Tel 714 990 2300 Toll Free 1 800 ALTINEX FAX 714 990 3303 E mail solutions altinex com Web www altinex com DISTRIBUTION AMPLIFIERS Sync on Green 0 3V 4 1 POWER Impedance 10 The DA1913GL requires the use of a 9 12V DC Output Video Signals Analog Signal Fall Rise Time ns Impedance Output Sync Signal 500mA power supply The DA1913GL is provided 1 0V p p 0 7V with a hard wired 12 inch power input cable with Composite Sync Sync on Green Impedance Frequency Compatibility Horizontal Minimum Video Bandwidth Typical Video Bandwidt