1. warranty card The following items are included with fans when purchased separately m this Installation Guide W warranty card Removable Power Supply and Fan Installing a Power Supply Unit or Fan Use these instructions to install PSUs chassis fan modules and FOMs Do not combine PWROI and PWRO2 PSUs in the same switch Do not combine AC and DC PSUs in the same switch Before you begin Read the safety information for the switch Safety information is in the x900 Series Switch and SwitchBlade x908 Installation and Safety Guide You can download this document from www alliedtelesis com support software Gather necessary tools and equipment You will need an appropriate flat bladed or Phillips 1 screwdriver to tighten or loosen the captive screws Verify the package contents if you have not already done so See Package Contents on page 5 Contact your authorised Allied Telesis distributor or reseller if items are damaged or missing Remove the unit from its packing material in an anti static environment Caution Follow correct anti static procedures Failure to do so could damage the PSU fan or switch If you are unsure about correct procedures contact your authorised Allied Telesis distributor or reseller Caution When adding or replacing power supplies keep your hands and fingers out of the power supply bays After installing a PWRO5 power supply use a screwdriver to tighten the captive screw
2. Information Technology Equipment lmmumnity characteristics Limits and methods of measurement m EN60950 1 2001 including 11 2004 Information Technology Equipment including electrical business equipment General Requirements m EN61000 3 2 2000 including A2 2005 Electromagnetic compatibility EMC part 3 2 Limits for harmonic current emissions equipment input current up to and including 16 per phase m EN61000 3 3 1995 including A1 2001 and A2 2005 Electromagnetic compatibility EMC part 3 3 Limitation of voltage fluctuations and flicker in low voltage supply systems for equipment with rated current up to 16 Name Dougal Oliver Position On behalf of the Manufacturer Manager Engineering Programme Signature ee Date of issue 13 May 2008 Place of issue 27 Nazareth Ave
3. Power Supply and Fan Pp Installing a PWRO05 or FANO3 If you are replacing a PSU turn off the main power source to the PSU and disconnect the power cord before removing it The DC earthing connection is not necessary for the SwitchBlade x908 when using AC PSUs because the chassis is grounded through the power cords Remove the current PSU fan module or blanking plate from the switch Using a screwdriver loosen the captive screw s until fully loosened PSU bays Service access Captive screw If a unit is already in the bay slide it out slowly and carefully Support the unit from underneath as you remove it to prevent it from falling Avoid the spinning blades on chassis fan modules Contact may cause personal injury or damage the unit Cover empty bays because dust and debris could overheat or damage the unit and switch Do not operate the switch for extended periods without functioning chassis fan modules Doing so will cause the switch to overheat and shut down and may damage the switch Insert the new PSU or chassis fan module and carefully slide it into the bay If you are installing a PSU unlock the latch on the PSU first by loosening the captive screw Insert the PSU or fan module slowly being sure to keep it straight Firmly press the unit until the faceplate engages or nearly engages the chassis Forcing a misaligned unit into the bay may damage both the unit and chassis Secure the unit i
4. Power supply specifications m 40 to 60V 48V nominal W supports either positive grounded or negative grounded operation m al5Ampcertified listed circuit breaker is required for circuit protection Supply cable specifications three core cable is required minimum core size 3 3mm 12 AWG high strand count copper wire m minimum cable rating 600V 90 degrees C Warning Disconnect the power supply cable before starting this procedure I Remove the transparent protective terminal cover 2 Strip the supply cable wires to expose 7 5mm 0 31 in of bare conductor Terminate the wire with a nylon insulated solderless ring tongue terminal JST FN5 5 5 or equivalent using a crimp tool 3 Connect the ground wire to the ground terminal Use the diagram on the rear panel of the switch to identify terminals Tighten the terminal to between 2 4 and 4 0 Nm 21 3 and 35 4 Ibf in Caution Check that the PSU terminals are wired to the correct polarity You will damage the PSU if you incorrectly connect it 4 Connect the positive feed to the positive terminal and the negative feed to the negative terminal Tighten the terminals to between 2 4 and 4 0Nm 21 3 and 35 4 Ibf in Note that the DC return input terminal must be connected as an Isolated DC return DC I Removable Power Supply and Fan Ensure there no exposed cable strands Replace the cover You must replace the transparent plastic terminal cover b
5. the acceptable range DC output voltage is within 12V 1076 Off DC output voltage is outside the acceptable range g Red A fault has occurred There is either a fan failure or the temperature has exceeded its limit of 70 C 158 F Off No fault conditions detected FANOI The following table describes LEDs on the FANOI fan only module LED State Description FAULT Red The fan has failed FANO3 The following table describes LEDs on the FANO3 chassis fan module LED State Description FAN Red The fan has failed STATUS Removable Power Supply and Fan Switch The following table describes how LEDs on the switch report operations and faults with installed PSUs and FOMs LED PSU 1 and PSU 2 State Green Description The PSU is installed and supplying power to the switch The voltage output is within specification Red One of the following The PSU is installed in the switch and a fan has failed or the PSU has exceeded its recommended temperature threshold of 70 C 158 F A 15 installed in the switch and a fan has failed The x900 12XT S and the SwitchBlade x908 switches do not support FOMs The bay is empty Applies to AT 8948 AT 9924Ts x900 24XT x900 24XT N and x900 24XS switches which require a FOM when only one PSU is installed Dual PSUs are installed but the PSU is not receiving power Off A FOM is installed and operating at an acceptable spee
6. 900 48FE v x900 48FS v AT 9924T AT 9924SP AT 9924Ts x900 24XT x900 24XT N 1 SI SEES S x900 24XS SwitchBlade x908 v v You can download complete documentation for these switches from www alliedtelesis com support software For more information about the documentation and other resources see Obtaining Documentation and Resources on page 17 Installation Guide Package Contents Depending on the model switches are shipped with a single supply unit PSU either AC or DC Some models also have fan only modules FOM chassis fan modules or blanking plates W The AT 8948 AT 9924Ts x900 24XT x900 24XT N and x900 24XS switches have a PSU and a FOM installed m The x900 48FE x900 48FS AT 9924T and AT 9924SP switches have a PSU and a blanking plate installed m SwitchBlade x908 is shipped with dual chassis fan modules and blanking plates but no PSUs The following items are included with each factory installed PSU Contact your authorised Allied Telesis distributor or reseller if any are damaged or missing m one AC power cord AC models power cord retaining clip AC models W warranty card The following items are included with PSUs when purchased separately m one AC power cord AC models power cord retaining clip PWROI PWRO2 AC models only m clip on ferrite PWRO5 only m this Installation Guide W
7. Removable Power Supply and Fan Installation Guide AT PWROI AT PWR02 5 AT FANO AT FAN03 S F Allied Telesis Removable Power Supply and Fan Installation Guide AT PWROI AT PWRO2 AT PWRO5 AT FANOI Download the complete document set from www alliedtelesis com support software Allied Telesis Removable Power Supply and Fan Removable Power Supply and Fan Installation Guide Document Number C613 04057 00 REV L 2008 Allied Telesis Inc All rights reserved No part of this publication may be reproduced without prior written permission from Allied Telesis Inc Allied Telesis Inc reserves the right to change specifications and other information in this document without prior written notice The information provided herein is subject to change without notice In no event shall Allied Telesis Inc be liable for any incidental special indirect or consequential damages whatsoever including but not limited to lost profits arising out of or related to this manual or the information contained herein even if Allied Telesis Inc has been advised of known or should have known the possibility of such damages Allied Telesis Allied VVare AlliedVVare Plus and SwitchBlade are trademarks or registered trademarks in the United States and elsewhere of Allied Telesis Inc Adobe Acrobat and Reader are either registered trademarks or trademarks of Adobe Systems Incorporated in the Unite
8. U woo Ferrite core Looped power cord 2 Plug the AC power cord into the power inlet on the PSU Removable Power Supply and Fan 3 Connect the power cord to the main power source 4 Check that the Run Standby switch is set to the Run position 1 Both the AC and DC LEDs should be lit Run Standby switch Note that when the Run Standby switch is set to the Standby position 0 the AC LED lights and the fan spins but the DC LED does not light and the PSU does not deliver power to the device 5 The PSU LED on the front panel of the switch lights green If the LED does not light green check the Run Standby switch See the Hardware Reference for more troubleshooting information Installation Guide Connecting a DC power supply Follow these instructions to connect an AT PWRO01 80 DC PSU to a DC power supply Only trained and qualified personnel should connect a DC power supply You need an appropriate DC power source DC supply cable ring connectors a crimp tool and an appropriate screwdriver to tighten the terminal screws For centralised DC power connection the switch should be installed in restricted access areas only such as dedicated equipment rooms or equipment closets in accordance with Articles 10 16 110 17 and 110 18 of the National Electrical Code ANSI NFPA 70
9. d For AT 9924T x900 48FE x900 48FS and SwitchBlade x908 switches a blanking plate is installed Installation Guide Removing a Power Supply Unit or Fan Follow these instructions to remove a PSU chassis fan module or FOM Before you begin Read the safety information for the switch Safety information is in the x900 Series Switch and SwitchBlade x908 Installation and Safety Guide You can download this document from www alliedtelesis com support software Gather necessary tools and equipment You will need an appropriate flat bladed or Phillips 1 screwdriver to tighten or loosen the captive screws Caution Follow correct anti static procedures Failure to do so could damage the PSU fan or switch If you are unsure about correct procedures contact your authorised Allied Telesis distributor or reseller Caution Keep your hands and fingers out of the power supply bays To remove a PSU chassis fan module or FOM If you are removing a PSU disconnect the power supply For AC PSUs turn off the main power source to the PSU and disconnect the power cord For DC PSUs push and release the Run Standby control to the Standby off position The Run Standby control is in the Run on position when it is depressed and in the Standby off position when it is not depressed Disconnect the supply cable wires from the circuit breaker Remove the PSU chassis fan module or FOM from the switch Cover the empty bay with a bla
10. d States and or other countries Microsoft and Visio are either registered trademarks or trademarks of Microsoft Corporation in the United States and or other countries Additional brands names and products mentioned herein may be trademarks of their respective companies Installation Guide Contents About this Guide eee pea pU E uicti deae i eR eese 4 Compatible Switches esent tentent tentent tentent tente 4 Package Contents 5 cede tete og eee 5 Installing a Power Supply Unit or Fan eerte 6 Connecting an AC power supply Connecting a DC power supply Checking LEDs etr tot n e ee e ES Aper t ede Removing a Power Supply Unit or Fan eerte 15 Tro bleshooting prt et dete torrent eee epp re l6 Obtaining Documentation and Resources serene 17 Standards EC Declaration of Conformity eee tentenntrntenntennenntenn 20 Removable Power Supply and Fan About this Guide This Installation Guide describes how to install the following PSUs and fans m AT PWROI PSU either AC DC power supply unit m AT PWRO2 PSU AC only m AT PWRO5 PSU AC only m AT FANOI fan only module AT FANO3 chassis fan module Compatible Switches The following table shows which models of PSUs and fans are appropriate for individual switches Switch PWROI PWRO2 PWRO05 FANOI FANO3 AT 8948 v v x
11. efore continuing Secure the supply cable to the rack framework or a similar object to ensure that connections are isolated from any force applied to the cable Ensure the circuit breaker for the supply circuit and the Run Standby control on the PSU are off Press and release the Run Standby control so that it is not pushed in which is the Off position Connect the supply cable wires to the circuit breaker Turn on the PSU by pushing in the Run Standby control Confirm that the switch is receiving power Check that at least one of the PSU LEDs on the front panel of the switch is lit green If no LEDs light refer to the Hardware Reference for troubleshooting information Installation Guide Checking LEDs LEDs on PSUs fans and the front panels of switches indicate the operational status of the devices After you have installed a PSU or fan and have powered on the switch check the LEDs to verify operation by using the following tables PWROI The following table describes LEDs on the PWROI and PWRO2 power supply PWRO2 units LED State Description FAULT Red The temperature on the PSU has exceeded the limit of 75 C 167 F or the fan failed PWR Green A PSU is installed in the switch and is delivering power GOOD PWRO5 The following table describes LEDs on the PWRO5 power supply unit LED State Description zs Green AC input voltage is within 90 264 VAC 47 63Hz Off AC input voltage is outside
12. es in x900 Series and SwitchBlade x908 switches m the AT 9900s Series Switch Expansion Module Installation Guide which describes how to install expansion modules in AT 9900s Series switches m the x900 Series Switch Allied Ware Operating System Software Reference which contains detailed information on configuring switches running the Allied Ware operating system m the AlliedWare Plus Operating System Software Reference which contains detailed information on configuring switches running the Allied Ware Plus operating system You can download these documents and updates from www alliedtelesis com support software You need Adobe Acrobat Reader software to view search or print these documents You can download it from www adobe com Other resources How To Notes describe a range of standard Allied Telesis solutions and include technical tips and guides to configuring specific hardware and software features You can download the latest How To Notes from www alliedtelesis com resources literature howto aspx MIBs supported by Allied Telesis products can be downloaded from www alliedtelesis com support software Microsoft Visio stencils for Allied Telesis products can be downloaded from www alliedtelesis com resources images visio aspx Removable Power Supply and Fan AT TFTP Server for Windows is a TFTP Trivial File Transfer Protocol server for transferring software versions configuration scripts and other files b
13. etween a PC and the switch You download AT TFTP Server from www alliedtelesis com support software CD ROM Some products also ship with a CD ROM containing documentation and resources Contacting us With locations covering all of the established markets in North America Latin America Europe Asia and the Pacific Allied Telesis provides localized sales and technical support worldwide To find the representative nearest you visit us on the Web at www alliedtelesis com Installation Guide Standards Products in this document meet the following standards Approval Agency and Requirement UL60950 1 CAN CSA C22 2 No 60950 1 03 EN60950 1 ASINZS 60950 1 Electromagnetic Compliance FCC CFR47 Part 15 Class A EN55022 Class A VCCI Class A ASINZS CISPR22 Class A CNS 13438 Class A EN61000 3 2 3 Immunity EN55024 U S Federal Communications Commission RADIATED ENERGY Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with this instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harm
14. ful interference in which case the user will be required to correct the interference at his own expense Note Modifications or changes not expressly approved by the manufacturer or the FCC can void your right to operate this equipment Canadian Department of Communications This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil num rique de la classe respecte toutes les exigences du R glement sur le mat riel brouilleur du Canada cOXKiBI S 77AATSSEIx IIBCS COXBEXIEIUSCSRBSS CERUGBESEROTCEPHVET COMBI AAP BIER SLIBKENSCEPHVETF VCCI A BERRADE Tele n Beers px TH Sle o BSMI A Removable Power Supply and Fan 20 EC Declaration of Conformity We ALLIED TELESIS LABS LIMITED 27 NAZARETH AVENUE CHRISTCHURCH 8024 NEW ZEALAND Declare under our sole legal responsibility that these products AT PWROI AT PWRO0I 80 AT PWRO2 and AT PWROS5 Power Supply Units Are in conformity with the essential requirements of directives m 2006 95 EC Low Voltage Directive m 89 336 EEC Electromagnetic Compatibility EMC Directive including its amending directives 92 3 EC 93 68 EEC and 2004 108 EC with reference to the following harmonised standards m EN55022 1998 including A1 2000 and A2 2003 Information Technology Equipment Radio disturbance m EN55024 1998 including A1 2001 and A2 2003
15. n the switch by tightening the captive screw s on the faceplate On the PWRO5 use a screwdriver to tighten the captive screw such that a screwdriver will be required to remove the PSU at a later date gt Installation Guide Connecting an AC power supply Follow these instructions to connect an AT PWROI AT PWRO2 or AT PVWRO5 AC PSU to an AC power supply Warning The AT PWROI AC PSU has a fuse rating of 250V 5A for FHIOI and FH102 Warning The AT PWROI AC PSU has double pole neutral fusing Electric shock is possible since there are dual primary fuses one on the phase circuit and one on the neutral circuit If the neutral opens the phase may still be live Warning For SwitchBlade x908 AC models the grounding stud on the rear of the unit is for supplemental grounding only The system must be supplied by a grounded 3 wire AC source through the power supply cord Connecting a PWROI or PWRO02 1 Plug the supplied AC power cord into the power inlet on the PSU and attach the retaining clip 2 Connect the power cord to the main power source 3 PSU LED on the front panel of the switch lights green If the LED does not light refer to the Hardware Reference for troubleshooting information Connecting a PWRO05 1 Forma loop in the supplied AC power cord at the PSU end and clip the ferrite core over the looped cord as shown in the following illustration This keeps the ferrite core in its correct position close to the PS
16. nking plate to prevent dust and debris from overheating or damaging the switch Removable Power Supply and Fan Troubleshooting If the PSU does not function as expected Check that all cable connections are correct and secure On the PWRO DC model check that the Run Standby switch has been pressed and is in the On position On the PWRO5 AC model check that the Run Standby switch has been set to Run position 1 Check that the PSU is receiving the correct AC voltage AC models If LEDs indicate a PSU fault replace the PSU or have your authorised Allied Telesis distributor or reseller service it Troubleshooting information is also in the x900 Series Switch and SwitchBlade x908 Hardware Reference You can download this document from www alliedtelesis com support software Installation Guide Obtaining Documentation and Resources The complete document set for x900 Series switches and SwitchBlade x908 includes W this Installation Guide m the x900 Series Switch and SwitchBlade x908 Installation and Safety Guide which describes how to install the switch and includes important safety and statutory information the x900 Series Switch and SwitchBlade x908 Hardware Reference which contains detailed information on x900 Series and SwitchBlade x908 switches and their hardware features the x900 Series Switch and SwitchBlade x908 Expansion Module Installation Guide which describes how to install expansion modul
17. such that a screwdriver will be required to remove the PSU at a later date Installation Guide Installing a PWROI PWRO02 or FANOI If you are replacing a PSU disconnect the power cord from the currently installed PSU before removing it For AC PSUs turn off the main power source to the PSU and disconnect the power cord For DC PSUs push the Run Standby control and release it to the Off position When the Run Standby control is not depressed it is off Disconnect the supply cable wires from the circuit breaker Remove the current PSU fan or blanking plate from the switch Loosen the captive screws until fully loosened Captive screw Captive screw If a unit is already in the bay slide it out slowly and carefully Support the unit from underneath as you remove it to prevent it from falling Cover empty bays with a blanking plate because dust and debris could overheat or damage the unit and switch Insert the new PSU or fan unit and carefully slide it into the bay Insert it slowly being sure to keep it straight Firmly press the unit until the faceplate engages or nearly engages the chassis Forcing a misaligned unit into the bay is likely to damage both the unit and chassis Note that when you have only one PSU installed in the AT 9924T and AT 9924SP switches it must be installed in bay 2 to optimise cooling Secure the unit in the switch by tightening the captive screws on the faceplate Removable