Home
Allied Telesis Switch AT-GS950/24 User's Manual
Contents
1. Reboot Reboot Type Normal Note System will reset in a few seconds after pressing Apply button Figure 16 Factory Default Reset Disabled Page 9 From the main menu on the left side of the page select Save Configuration to Flash to permanently save your changes 35 How to Start an AT GS950 24 WEB Management Session Enabling Factory 36 If the Factory Default Reset feature is disabled and you choose to Default Reset Enable it perform the following procedure 1 From the main menu on the left side of the page select the Tools folder The Tools folder expands From the Tools folder select Reboot The Factory Default Reset Reboot Page is displayed See Figure 16 Go to the Factory Default Reset section on the upper part of the page The Factory Default Reset field should be set to Disable Note If the Factory Default Reset field is already set to Enable you do not need to continue with this procedure To enable the factory default reset feature select Enable on the pull down menu of the Factory Default Reset field The Factory Default Reset Reboot Page changes to include a Password field for entering a password See Figure 17 on page 36 Factory Default Reset Factory Default Reset Enable v Password Maximum length is 12 Note Enter P W and click Apply to enable Factory Default Reset feature Apply Reboot Reboot Type Normal v Apply Note System will reset in a few seco
2. The User Interface Page is displayed See Figure 12 User Interface SNMP Agent Enable v Web Server Status Enable v Apply Web Idle Timeout 60 Min 3 60 Apply Figure 12 User Interface Page 3 Choose Enable or Disable from the pull down list for the SNMP Agent parameter Enabled When you enable this parameter the SNMP agent is active You can manage the AT GS950 24 switch with Network Management Software and the switch s private MIB Disabled When you enable this parameter the SNMP agent is inactive Note For more information about SNMP see the AT GS950 Web User Guide 4 Click Apply located under the Web Server Status Enable Disable field User Interface Timeout How to Start an AT GS950 24 WEB Management Session 5 From the main menu on the left side of the page select Save Configuration to Flash to permanently save your changes To set the Web Idle Timeout perform the following procedure 1 From the main menu on the left side of the page click the System folder The System folder expands From the System folder select User Interface The User Interface Page is displayed See Figure 12 on page 26 Refer to the bottom portion of the web page Enter the Web Idle Timeout parameter The range is from 3 to 60 minutes From the main menu on the left side of the page select Save Configuration to Flash to permanently save your changes 27 How to Start an AT GS950 24 WEB
3. you can enter it in the browser When the DHCP feature is enabled a DHCP server automatically assigns an IP address which is not advertised over the network As a consequence you do not know what IP address has been assigned to the switch Note The new IP address assignment from the DHCP server may take one to two minutes before the process is completed Fortunately there is an ATI Web Discovery Tool available that resolves this issue It detects the MAC address IP address and other information of the AT GS950 series switches that are present on your local area network Note The ATI Web Discovery Tool is available for download on the AT GS950 24 product page at alliedtelesis com How to Start an AT GS950 24 WEB Management Session DHCP Client Configuration This procedure explains how to activate and deactivate the DHCP client on the AT GS950 24 switch When the client is activated the switch obtains its IP configuration including an IP address and subnet mask from a DHCP server on your network Before performing the procedure note the following o By default the DHCP client is disabled on the switch o The DHCP client supports DHCP Auto Configuration Settings or BOOTP See DHCP Auto Configuration on page 20 for more information O After you enable DHCP your current management session ends because a different IP address is assigned to the switch by the DHCP server The new IP address can be discover
4. AT GS950 24 WEB Management Session 42 10 From the Syslog Status field select one of the following choices from the pull down menu Enable The System log is active Disable The System log is inactive From the Time Stamp field select one of the following choices from the pull down menu Enable Each event message recorded in the log will have a time stamp recorded with it Disable No time stamp will be recorded with the event messages Enter the Messages Buffer Size The range is between 1 and 200 Enter the Syslog Server IP Address The format is xxx xxx xxx xxx If the address is left at the default setting of 0 0 0 0 no server is specified In the Facility field enter the Facility local from the pull down menu The choices range from local0 through local7 Select the Logging Level This parameter specifies what level of event messages will be logged into the System log Your choices are as follows 0 Emergency The system is unusable 1 Alert Action must be taken immediately 2 Critical Critical conditions are displayed 3 Error Error conditions are displayed 4 Warning Warning conditions are displayed 5 Notice Normal but significant conditions are displayed 6 Informational Informational messages are displayed 7 Debug Debug level messages are displayed Click Apply The System log is now active From the main menu on the left side of the page select Save Configuration to Flash t
5. E Save Configuration to Flash Switch Information System Up For 0 day s 0 hr s 1 min s 39 sec s Runtime Image AT S109 V1 1 0 1 00 043 Boot Loader 1 00 005 Hardware Information Version Al DRAM Size 64M Flash Size 16M Administration Information e System Name e System Location e System Contact System MAC Address IP Address Subnet Mask and Gateway MAC Address 00 01 02 03 04 05 IP Address 10 4 17 60 Subnet Mask 255 255 252 0 Default Gateway 10 4 16 1 Automatic Network Features DHCP Client Mode Enable BOOTP Client Mode Disable Figure 3 AT S109 Home Page The main menu appears on the left side and is common for all of the management pages discussed in this manual It consists of the following folders and web pages Switch Info Front Panel System Physical Interface Bridge SNMP Access Control RMON Voice VLAN Security LLDP Statistics Chart Tools Oaogoaogoadeauda agdoanugdaadaua u Save Configuration How to Start an AT GS950 24 WEB Management Session 5 To see the front panel of the switch select Front Panel from the main menu on the left side of the page The AT S109 Management software displays the front of the switch Ports that have a link to an end node are green Ports without a link are grey The AT GS950 24 switch front panel page is shown in Figure 4 Front Panel e Port Not Connected Port Disabled e STP Discar
6. Management Session System Information Display The Switch Information page is initially displayed when you first log into the AT GS950 24 switch It provides general information about the switch To view this information perform the following procedure 1 From the main menu on the left side of the page select Switch Info The Switch Information Page is displayed See Figure 13 MWe Alligd Telesis 47 6s950 24 Gigabit Ethernet WebSmart Switch be AT GS950 24 Switch Info Front Panel A System Physical Interface Bridge E SNMP S Access Control Config RMON E voice VLAN E Security 3 DHCP Snooping LLDP m Statistic Chart E Tools E Save Configuration to Flash ic TAAA A A A 28 Switch Information System Up For Runtime Image Boot Loader Hardware Information Version e DRAM Size Flash Size Administration Information e System Name e System Location e System Contact System MAC Address IP Address Subnet Mask and Gateway MAC Address IP Address e Subnet Mask Default Gateway Automatic Network Features DHCP Client Mode BOOTP Client Mode 0 day s 0 hr s 1 min s 39 sec s AT S109 V1 1 0 1 00 043 1 00 005 Al 64M 16M 00 01 02 03 04 05 10 4 17 60 255 255 252 0 10 4161 Enable Disable Figure 13 AT GS950 24 Switch Information Page The Switch Information Page displays the following information System Up For The number o
7. the left side of the page to save the new IP address to memory Caution If you do not select Save Configuration to Flash the IP address will revert to its original setting when you power cycle or reboot the switch How to Start an AT GS950 24 WEB Management Session IP Access List Configuration Create an IP Access List When the IP Access List feature is enabled remote access to the AT S109 management software is restricted to the IP addresses entered into the IP Access List The procedures in this section describe how to enable or disable the IP Access List feature and how to add or remove IP addresses from the list See the following sections o Create an IP Access List on page 11 o Delete an IP Address List Entry on page 13 Note To modify IP address that has already been created it must first be deleted and them re created using the following procedures To create a list of accessible IP addresses perform the following procedure 1 From the main menu on the left side of the page click the System folder The System folder expands 2 From the System folder select IP Access List The IP Access List Page is displayed See Figure 6 IP Access List IP Restriction Status Disable Apply IP Address Add Index Accessible IP Action lt lt IP List is empty gt gt Figure 6 IP Access List Page 3 Enter an IP address in the IP Address field usi
8. 0 24 switch has a web browser server for remote management of the unit with a web browser application from management workstations on your network By default the server operates in a non secure HTTP mode and can be configured to communicate in a secure HTTPS mode with SSL protocol In many situations the communication with the switch will be in a controlled environment and it is acceptable to communicate with the management software in the HTTP mode However you may find that your management communications are subject to outside security risks and web sessions conducted in the non secure HTTP mode are vulnerable to security issues because the packets are sent in clear text Web browser management sessions that use the secure HTTPS mode with SSL protocol are protected against snooping because the packets exchanged between the switch and your management workstations are encrypted When operating in this mode only the AT GS950 24 switch and the web browser are able to decipher the packets sent and received between them To enable or disable the SSL protocol feature perform the following procedure 1 From the main menu on the left side of the page click the System folder The System folder expands 2 From the System folder select SSL Settings The SSL Settings Page is displayed See Figure 20 SSL Settings SSL Status Disable v Apply Figure 20 SSL Settings Page 3 From the SSL Settings field select one of the following cho
9. ding e STP Forwording STP Learning Figure 4 AT GS950 24 Front Panel Page A web browser management session remains active even if you link to other sites You can return to the management web pages anytime as long as you do not quit the browser How to Start an AT GS950 24 WEB Management Session Web Browser Tools You can use the web browser tools to move around the management pages Selecting Back on your browser s toolbar returns you to the previous display You can also use the browser s bookmark feature to save the link to the switch How to Start an AT GS950 24 WEB Management Session Configuration of IP Address Subnet Mask and Gateway Address This procedure explains how to change the IP address subnet mask and gateway address of the switch Before performing the procedure note the followin o g A gateway address is only required if you want to remotely manage the device from a management station that is separated from the switch by a router To configure the switch to automatically obtain its IP configuration from a DHCP server on your network go to DHCP Client Configuration on page 18 To change the switch s IP configuration perform the following procedure 1 From the main menu on the left side of the page click the System fold er The System folder expands 2 Fro m the System folder select IP Setup The IP Setup Page is displayed See Figure 5 IP Setup Syst
10. e Setting SNTP How to Start an AT GS950 24 WEB Management Session Use the pull down menu to set the Clock Mode parameter to Local time In the Local Time Settings section set the Date Setting YYYY MM DD to the current date in the YYYY MM DD format In the Local Time Settings section set the Time Settings HH MM SS to the current time in the HH MM SS format Click the Apply button at the bottom of the page The time will take effect immediately Save your new settings or any changes to the configuration file by selecting Save Configuration to Flash from the main menu on the left side of the page To configure SNTP perform the following procedure 1 From the main menu on the left side of the page click the System folder The System folder expands From the System folder select System Time The System Time Page is displayed See Figure 7 on page 14 Use the pull down menu to set the Clock Mode parameter to SNTP Enter the IP address of the SNTP Primary Server The format is XXX XXX XXX XXX Enter the IP address of the SNTP Secondary Server The format is XXX XXX XXX XXX Enter the SNTP Poll Interval The range is 1 60 minutes Enter the local Time Zone from the pull down menu Click the Apply button at the bottom of the page The switch will immediately start polling the SNTP primary server for time information Save your new settings or any changes to the configuration file by selecting Save Configu
11. e you must set your local PC to the same subnet as the switch To start a web browser management session do the following procedure 1 Start your web browser 2 Inthe URL field of the browser enter 192 168 1 1 which is the default IP address of the switch See Figure 1 DO Porn sero O E a aa El hth 192 168 1 1 Switch s IP Address Figure 1 Entering a Switch s IP Address in the URL Field How to Start an AT GS950 24 WEB Management Session The AT S109 Management Software displays the login dialog box shown in Figure 2 Connect to Taz daad K User name manager Password escece _ Remember my password Ce ever Figure 2 Management Login Dialog Box 3 Enter the AT S109 management login user name and password The default user name is manager and the default password is friend 4 Press OK The login name and password are case sensitive The switch Home Page is displayed See Figure 3 on page 6 for an example of the AT S109 Home Page To change the user name and password refer to Configuring System Administration Information on page 19 How to Start an AT GS950 24 WEB Management Session BWV Allied Telesis 4t s950 24 Gigabit Ethernet WebSmart Switch Ls AT GS950 24 E Switch Info Front Panel System E Physical Interface Bridge H SNMP H Access Control Config H A RMON 9 voice VLAN w Security m DHCP Snooping tM LLDP Statistic Chart m Tools
12. e Tools folder select Ping The Ping Test Configuration Page is displayed See Figure 18 Ping Test Configuration Destination IP Address 0 0 0 0 Timeout Value 3 Sec 1 5 Number of Ping Requests 10 Times 1 10 Start _Show Ping Resut Figure 18 Ping Test Configuration Page 3 Configure the following parameters Destination IP Address The IP address of the node you want to ping in the xxx xxx xxx xxx format Timeout Value Specifies the length of time in seconds the switch waits for a response before assuming that a ping has failed Number of Ping Requests Specifies the number of ping requests you want the switch to perform 4 Click Start 37 How to Start an AT GS950 24 WEB Management Session 38 5 To view the ping results click Show Ping Results A sample Ping Test Results Page is displayed See Figure 19 Ping Test Result RESULT Destination IP Address 192 168 1 137 Pass 100 Average Time 5ms Back to Ping Test Figure 19 Ping Test Results Page The following information is displayed Destination IP Address Indicates the IP address of the unit that receives the ping Pass Indicates the percentage of times the ping passed Average Time Indicates the time in milliseconds the ping was received 6 Click Back to Ping Test to return to the Ping Test Configuration Page SSL Settings How to Start an AT GS950 24 WEB Management Session Configuring SSL The AT GS95
13. ed using the ATI Discovery Tool See DHCP and ATI Web Discovery Tool on page 17 for more information To activate or deactivate the DHCP client on the switch perform the following procedure 1 From the main menu on the left side of the page click the System folder The System folder expands From the System folder select IP Setup The IP Setup Page is shown in Figure 5 on page 9 From the pull down menu next to the DHCP Mode field select Enable or Disable Click Apply When the DHCP client is Enabled the web server connection to the switch is lost because a different IP address is assigned to the switch by the DHCP server Caution Enabling DHCP may end your current management session 5 Use the ATI Web Discovery Tool to find the new IP address assigned to the switch by the DHCP server See DHCP and ATI Web Discovery Tool on page 17 for more information How to Start an AT GS950 24 WEB Management Session Note The ATI Web Discovery Tool is available for download on the AT GS950 24 product page at alliedtelesis com 6 Follow the procedure to log on with the new IP address provided by the DHCP Server as described in Establishing a Remote Connection to the Web Browser Interface on page 4 Save your new settings or any changes to the configuration file by selecting Save Configuration to Flash from the main menu on the left side of the page If you do not save the new configuration w
14. em MAC Address System IP Address System Subnet Mask System Default Gateway DHCP Mode 00 01 02 03 04 05 192 168 N 11 255 255 255 0 0 0 0 0 Disable v Ay Figure 5 IP Setup Page 3 Change the IP configuration parameters by observing or entering new information in the following fields System MAC Address This parameter displays the MAC address of the switch You cannot change this parameter System IP Address Displays the current IP address of the switch To change the IP address enter a new IP address When DHCP is enabled you cannot change this parameter System Subnet Mask Displays the current subnet mask of the switch To change the subnet mask enter a new subnet mask When DHCP is enabled you cannot change this parameter How to Start an AT GS950 24 WEB Management Session System Default Gateway Displays the default gateway of the switch To change the default gateway enter a new gateway When DHCP is enabled you cannot change this parameter DHCP Mode For information about setting this parameter refer to DHCP Client Configuration on page 18 4 Click Apply Note Changing the IP address ends your management session To resume managing the device enter the new IP address of the switch in the web browser s URL field as shown in Figure 1 on page 4 5 After you log on to the switch with the new IP address select Save Configuration to Flash from the main menu on
15. f days hours and minutes that the switch has been running since it was last rebooted Runtime Image The version number of the runtime firmware Boot Loader The version number of the bootloader firmware Hardware Information Section Version The hardware version number DRAM Size The size of the DRAM in megabytes Flash Size The size of the flash memory in megabytes How to Start an AT GS950 24 WEB Management Session Administration Information Section Switch Name This parameter displays the name assigned to the switch To assign the switch a name refer to System Management Information on page 21 Switch Location This parameter displays the location of the switch To assign the location refer to System Management Information on page 21 Switch Contact This parameter displays the contact person responsible for managing the switch To assign the name of a contact refer to System Management Information on page 21 System MAC Address IP Address Subnet Mask and Gateway Section MAC Address This parameter displays the MAC address of the switch IP Address This parameter displays the system IP address Refer to Configuration of IP Address Subnet Mask and Gateway Address on page 9 to manually assign an IP address or DHCP Client Configuration on page 18 to activate the DHCP client Subnet Mask This parameter displays the subnet mask for the switch Refer to Config
16. f disabling this function Allied Telesis has no knowledge of it You are responsible for keeping the password in a safe place If it is lost Allied Telesis does not have a way to help you recover it See Disabling Factory Default Reset Feature on page 34 for information about how to disable the factory default reset feature Switch Reboot The following procedure outlines how to reboot your AT GS950 24 switch Caution This procedure reboots the switch and reloads the AT S109 Management software configuration from flash memory Insure that your current configuration is saved before rebooting the switch by selecting Save Configuration to Flash from the main menu on the left side of the page to permanently save your changes All configuration parameters that have not been previously saved are lost After the switch is reboots they are reset to the values stored in the flash memory Caution This procedure causes the switch to reboot The switch does not forward network traffic during the reboot process Some network traffic may be lost 1 From the main menu on the left side of the page select the Tools folder The Tools folder expands 2 From the Tools folder select Reboot The Factory Default Reset Reboot Page is displayed See Figure 14 31 How to Start an AT GS950 24 WEB Management Session 32 Configure Factory Default Values Factory Default Reset Factory Default Reset Enable v Reboot Rebo
17. form the following procedure Note The AT S109 Management software default values are listed in the AT GS950 Web User Guide 1 From the main menu on the left side of the page select the Tools folder The Tools folder expands 2 From the Tools folder select Reboot The Reboot Page is displayed See Figure 14 on page 32 3 Go to the lower part of the page to the Reboot section 4 In the Reboot Type field use the pull down menu to select one of the following options Normal This setting reloads all configuration parameters that are saved in flash memory See Switch Reboot on page 31 for more information when using this selection Factory Default Resets all switch parameters to the factory default settings including the IP address subnet mask and gateway address Caution This setting will cause the IP address to be reset to 192 168 1 1 You will loose connectivity with the switch management software after the reboot is completed and you can login again with this IP address Factory Default Except IP Address Resets all switch parameters to the factory default settings but retains the current IP address subnet mask and gateway settings saved in flash memory If the DHCP client is enabled it remains enabled after this reset and assignment of the IP address subnet mask and gateway settings are managed by the DHCP server 33 How to Start an AT GS950 24 WEB Management Session Disabling Factor
18. friendly MV Allied Telesis AT GS950 24 Gigabit Ethernet Smart Switch How to Start a WEB Management Session 613 001499 Rev B AV Allied Telesis the solution the network Copyright 2011 Allied Telesis Inc All rights reserved No part of this publication may be reproduced without prior written permission from Allied Telesis Inc Allied Telesis and the Allied Telesis logo are trademarks of Allied Telesis Incorporated All other product names company names logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners Allied Telesis Inc reserves the right to make changes in specifications and other information contained in this document without prior written notice The information provided herein is subject to change without notice In no event shall Allied Telesis Inc be liable for any incidental special indirect or consequential damages whatsoever including but not limited to lost profits arising out of or related to this manual or the information contained herein even if Allied Telesis Inc has been advised of known or should have known the possibility of such damages How to Start an AT GS950 24 WEB Management Session This document contains the procedures to start you Web management session on the AT GS950 24 switch The following topics are discussed m QO n Oagoaadoada a Q Establishing a Remote Connection to the Web Br
19. h to permanently save your changes How to Start an AT GS950 24 WEB Management Session Delete User Name To delete a user name that you have previously added perform the and Password following procedure 1 From the main menu on the left side of the page click the System folder The System folder expands From the System folder select Administration The Administration Page is shown in Figure 10 on page 23 Identify the user name that you want to delete and click Delete The user name is removed from the Administration table Note The default user name cannot be modified or deleted The default password can be modified From the main menu on the left side of the page select Save Configuration to Flash to permanently save your changes 25 How to Start an AT GS950 24 WEB Management Session User Interface Configuration SNMP Interface 26 This procedure explains how to enable and disable the user interfaces on the switch With this procedure you can enable or disable the AT GS950 24 SNMP Agent For more information about SNMP see the AT GS950 Web User Guide The Web Server Status is displayed as Enabled for your information only The Web Server cannot be disabled To enable or disable the AT GS950 24 SNMP interface perform the following procedure 1 From the main menu on the left side of the page click the System folder The System folder expands From the System folder select User Interface
20. hen DHCP is enabled the software reverts to the previously saved IP address value when the switch is power cycled or rebooted If no IP address has been previously saved the IP address value reverts to 192 168 1 1 If you enable DHCP and then save your configuration you are saving the DHCP setting Enabled The next time the switch boots up it will use the DHCP process to establish the IP address used to manage the AT GS950 24 switch If you enter a new IP address after disabling DHCP and save your configuration the DHCP setting Disabled and the new IP address on the switch is saved The next time the switch boots up it will respond to the IP address that you entered when you re establish contact with the AT S109 Management software How to Start an AT GS950 24 WEB Management Session DHCP Auto Configuration 20 If you need to automatically update the switch s configuration files via a remote server the DHCP Auto Configuration feature is available for this purpose via the DHCP server Note You must enable the DHCP client so that this feature can operate with the DHCP server See DHCP Client Configuration on page 18 for more information To configure this feature on the switch perform the following procedure 1 From the main menu on the left side of the page click the System folder The System folder expands 2 From the System folder select System The DHCP Auto Configuration Settings Page is show
21. ices from the pull down menu Enable The secure SSL mode is active You must log in to the switch s management using the HTTPS mode on your browser Disable The secure SSL mode is inactive You must log in to the switch s management using the HTTP mode on your browser 39 How to Start an AT GS950 24 WEB Management Session 4 Click Apply The SSL setting that you have selected is now active 5 From the main menu on the left side of the page select Save Configuration to Flash to permanently save your changes 40 How to Start an AT GS950 24 WEB Management Session System Log Configuration The System log is designed to monitor the operation the AT GS950 24 switch by recording the event messages it generates during normal operation These events may provide vital information about system activity that can help in the identification and solutions of system problems To configure the System log perform the following procedure 1 From the main menu on the left side of the page click the System folder The System folder expands 2 From the System folder select System Log Configuration The System Log Configuration Page is displayed See Figure 21 System Log Configuration Syslog Status Disable v Time Stamp Enable Messages Buffered Size 1 200 50 Syslog Server IP 0 0 0 0 Facility local0 Logging Level info Apply Clear Refresh Figure 21 System Log Configuration Page 41 How to Start an
22. main menu on the left side of the page select Save Configuration to Flash to permanently save your changes How to Start an AT GS950 24 WEB Management Session System Time Manually Setting System Time The procedures in this section describe how to configure the system time by manually entering the time or through SNTP and how to configure the daylight savings time feature See the following sections o Manually Setting System Time on page 14 o Setting SNTP on page 15 O Setting Daylight Savings Parameters on page 16 To set the system time manually perform the following procedure 1 From the main menu on the left side of the page click the System folder The System folder expands 2 From the System folder select System Time The System Time Page is displayed See Figure 7 System Time Clock Mode Local Time Current Time 1 Jan 2009 11 57 32 Time Zone Date Time Settings Clock Mode Local Time v Local Time Settings Date Setting YYYY MM DD 2009 1 14 Time Setting HH MM SS 11 gt 57 32 Simple Network Time Protocol SNTP Settings SNTP Primary Server 0 0 10 10 SNTP Secondary Server 0 0 0 0 SNTP Poll Interval 1 Min 1 60 Time Zone Additional Time Parameters Daylight Saving Time Status Disabled From Month Day HH MM January 2 01 00 00 To Month Day HH MM January 01 00 00 DST Offset 1hr Apply Figure 7 System Time Pag
23. n in Figure 8 DHCP Auto Configuration Settings Auto Configuration State Disable v Figure 8 DHCP Auto Configuration Settings Page 3 From the Auto Configuration State field select one of the following choices from the pull down menu Enable The DHCP Auto Configuration feature is active Note You must enable the DHCP client so that this feature can operate with the DHCP server See DHCP Client Configuration on page 18 for more information Disable The DHCP Auto Configuration feature is inactive 4 Click Apply The DHCP Auto Configuration setting that you have selected is now active 5 From the main menu on the left side of the page select Save Configuration to Flash to permanently save your changes How to Start an AT GS950 24 WEB Management Session System Management Information This section explains how to assign a name location and contact information for the AT GS950 24 switch This information helps in identifying each specific AT GS950 24 switch among other switches in the same local area network Entering this information is optional Note Allied Telesis recommends that you assign a name to the switch Naming each switch can help you identify the specific switch you want to manage among others It can also help to avoid performing a configuration procedure on the wrong switch To set a switch s administration information perform the following procedure 1 From the main men
24. nds after pressing Apply button Figure 17 Factory Default Reset Reboot Page with Password Entry Enter the same password that you defined when you previously set the Factory Default Reset field to Disable Click Apply The initial Factory Default Reset Reboot Page is displayed with the Factory Default Reset field Enabled See Figure 14 on page 32 In the Reboot section the Reboot Type field now includes the options presented in its pull down menu for returning the switch configuration to the factory default values See Configure Factory Default Values on page 32 for more information From the main menu on the left side of the page select Save Configuration to Flash to permanently save your changes How to Start an AT GS950 24 WEB Management Session Pinging a Remote System This procedure instructs the AT GS950 24 switch to ping a node on your network This procedure is useful in determining whether an active link exists between the switch and another network device Note The device you are pinging must be a member of the Default VLAN and within the same local area network as your switch In other words the port on the switch through which the node is communicating with the switch must be an untagged or tagged member of the Default VLAN To ping a network device perform the following procedure 1 From the main menu on the left side of the page select the Tools folder The Tools folder expands 2 From th
25. ng a xxx xxx xxx xxx format 4 Click Add The IP address is added to the IP Access List table in the Accessible IP column How to Start an AT GS950 24 WEB Management Session Note You can add up to 10 IP address to the IP Access List table Delete an IP Address List Entry How to Start an AT GS950 24 WEB Management Session 5 From the IP Restriction Status field select one of the following choices from the pull down menu Enable This selection restricts the access to the AT S109 management software to the IP addresses in the table listed under Accessible IP Disable This selection allows unrestricted access to the AT S109 management software Click Apply Access to the management software is now restricted to those IP addresses listed in the IP Access List table From the main menu on the left side of the page select Save Configuration to Flash to permanently save your changes To delete an IP address from the IP Access List perform the following procedure 1 From the main menu on the left side of the page click the System folder The System folder expands From the System folder select IP Access List The IP Access List Page is displayed See Figure 6 on page 11 Select Delete next to the IP address that you want to remove The IP address is removed from the IP Access List table If you remove the last IP address from the table the IP Restriction Status field is set to Disable From the
26. o permanently save your changes How to Start an AT GS950 24 WEB Management Session Returning the AT S109 Management Software to the Factory Default Values This procedure returns all AT S109 Management software parameters to their default values and deletes all tagged and port based VLANs on the switch This procedure causes the switch to reboot The switch does not forward network traffic during the reboot process Some network traffic may be lost To return the AT S109 Management software to the default settings do the following procedure 1 From the Tools folder select Reboot The Reboot Page is shown in Figure 14 on page 32 For the Reboot Type field use the pull down menu to select one of the following Factory Default Resets all switch parameters to the factory default settings including the IP address subnet mask and gateway address Warning This setting will cause the IP address to be reset to 192 168 1 1 You will loose connectivity with the switch management software after the reboot is completed Factory Default Except IP Address Resets all switch parameters to the factory default settings but retains the IP address subnet mask and gateway settings If the DHCP client is enabled it remains enabled after this reset For the Reboot Status field use the pull down menu to select Start to begin the reboot Click Apply The switch is rebooted You must wait for the switch to complete the
27. on page 32 for more information Note Refer to the AT GS950 Installation guide for more information about how to use the eco friendly button to reboot or reset the switch Note The AT S109 Management software default values are listed in the AT GS950 Web User Guide If your switch is located in a controlled environment such as a locked switching closet or limited access equipment room it may be desirable to have the ability to easily reset the switch to factory defaults at any time by using either the front panel ecofriendly switch or the AT S109 management software However if your switch is installed in an uncontrolled environment you may want to protect the switch s configuration from unwanted or accidental resets The AT S109 management software allows you to disable the factory default reset feature and lock it with your own password When this is done two areas are affected o The reset and factory default reset features on the front panel ecofriendly switch are disabled o The factory default reset feature in the AT S109 management software is disabled However you can still reset the switch via the management software without affecting the switch s configuration The factory default reset can be enabled again by using the password that you initially defined when disabling this function How to Start an AT GS950 24 WEB Management Session Caution Since you define this password as part of the process o
28. ot Type Normal ba avow Note System will reset in a few seconds after pressing Apply button Figure 14 Factory Default Reset Reboot Page 3 Go to the lower part of the page to the Reboot section 4 In the Reboot Type field select Normal from the pull down menu When the switch is rebooted with this selection all configuration parameters that are saved in flash memory are loaded into the switch s active memory Note Two additional options are available in the Reboot Type field The procedures for these options are described in Configure Factory Default Values 5 Click Apply The switch immediately begins to reload the AT S109 Management software and configuration parameters This process takes approximately two minutes to complete You can not manage the device during the reboot After the reboot is finished you can log in again if you want to continue to manage the switch This procedure returns all AT S109 Management software parameters to their factory default values and deletes all tagged and port based VLANs on the switch Note The AT S109 Management software default values are listed in the AT GS950 Web User Guide How to Start an AT GS950 24 WEB Management Session Caution This procedure causes the switch to reboot The switch does not forward network traffic during the reboot process Some network traffic may be lost To return the AT S109 Management software to the default settings per
29. owser Interface on page 4 Web Browser Tools on page 8 Configuration of IP Address Subnet Mask and Gateway Address on page 9 IP Access List Configuration on page 11 DHCP Client Configuration on page 18 System Management Information on page 21 User Name and Password Configuration on page 23 User Interface Configuration on page 26 System Information Display on page 28 Pinging a Remote System on page 37 Pinging a Remote System on page 37 Returning the AT S109 Management Software to the Factory Default Values on page 43 Quitting a Web Browser Management Session on page 44 Note To permanently save your new settings or any changes to the configuration file select Save Configuration to Flash from the main menu on the left side of the page How to Start an AT GS950 24 WEB Management Session Establishing a Remote Connection to the Web Browser Interface The AT GS950 24 switch is shipped with a pre assigned IP address of 192 168 1 1 After your initial login you may want to assign a new IP address to your switch To manually assign an IP address to the switch refer to Configuring an IP Address Subnet Mask and Gateway Address on page 10 To configure the switch to obtain its IP configuration from a DHCP server refer to Enabling and Disabling the DHCP Client on page 14 Whether you use the pre assigned IP address or assign a new on
30. ration to Flash from the main menu on the left side of the page How to Start an AT GS950 24 WEB Management Session Setting Daylight Savings Parameters If you want to configure the switch for daylight savings time perform the following procedure 1 From the main menu on the left side of the page click the System folder The System folder expands From the System folder select System Time The System Time Page is displayed See Figure 7 on page 14 In the Daylight Savings Time Status field select Enabled Specify the Month Day Hour and Minute when Daylight Savings will take effect in the From time fields Specify the Month Day Hour and Minute when Daylight Savings will end in the To time fields Using the pull down menu specify the Daylight Savings offset in the DST Offset field You can select either 1 hr or 1 2 hr Save your new settings or any changes to the configuration file by selecting Save Configuration to Flash from the main menu on the left side of the page How to Start an AT GS950 24 WEB Management Session DHCP and ATI Web Discovery Tool The AT GS950 24 Gigabit Ethernet Smart switch is managed through a web browser interface only The factory default IP address is 192 168 1 1 The switch does not have a local console connector which means that you cannot learn what the switch s management IP address is on a web browser without first knowing what the address is Once the IP address is known
31. reboot process before establishing your management session again 43 How to Start an AT GS950 24 WEB Management Session Quitting a Web Browser Management Session To exit a web browser management session close the web browser 44
32. sponds to the user name entered in step 3 enter a password of up to 12 alphanumeric characters in the box next to the Password field The Password field is case sensitive To confirm the password entry retype the password in the box next to the Confirm Password field Click Add to activate your changes on the switch From the main menu on the left side of the page select Save Configuration to Flash to permanently save your changes To modify the a user name password perform the following procedure From the main menu on the left side of the page click the System folder The System folder expands From the System folder select Administration The Administration Page is shown in Figure 10 on page 23 Identify the user name that you want to change and click Modify in the Action column The Modify Administration Page is displayed See Figure 11 Note The default user name cannot be modified or deleted The default password can be modified Modify Administration User Name manager Password Confirm Password _Apply Figure 11 Modify Administration Page To change a password enter a password of up to 12 alphanumeric characters in the box next to the Password field To confirm the above password retype the password in the box next to the Confirm Password field Click Apply to activate your changes on the switch From the main menu on the left side of the page select Save Configuration to Flas
33. t Reset Factory Default Reset Disable v New Password Maximum length is 12 Confirm Password Apply Reboot Reboot Type Normal had Note System will reset in a few seconds after pressing Apply button How to Start an AT GS950 24 WEB Management Session Figure 15 Factory Default Reset Reboot Page with Password Entry 5 Inthe New Password field enter a password of up to 12 characters in length It is case sensitive There is not a default password for this field Caution Since you define this password as part of the process of disabling this function Allied Telesis has no knowledge of it You are responsible for keeping the password in a safe place If it is lost Allied Telesis does not have a way to help you recover it 6 Re enter the same password in the Confirm Password field 7 Click Apply The following message is displayed By clicking on Accept the Factory Default Reset function will be Disabled on both the switch management software and the physical front panel ecoFriendly button If you loose this password ATI cannot recover it for you By Clicking on Cancel the Factory Default Reset function will remain Enabled on both the switch management software and the physical front panel ecoFriendly button 8 Click Accept on the message The Factory Default Reset page changes and displays the Factory Default Reset feature as Disabled See Figure 16 Factory Default Reset Factory Default Reset Disable
34. u on the left side of the page click the System folder The System folder expands 2 From the System folder select Management The Management Page is displayed See Figure 9 for the AT GS950 24 Management Page Management System Description AT GS950 24 System Object ID 1 3 6 1 4 1 207 1 4 167 System Name System Location System Contact Caeo Figure 9 AT GS950 24 Management Page 3 Configure the following parameters as necessary System Description Specifies the Allied Telesis switch model You cannot change this parameter System Object ID Indicates the unique SNMP MIB object identifier that identifies the switch model You cannot change this parameter 21 How to Start an AT GS950 24 WEB Management Session 22 System Name Specifies a name for the switch for example Sales The name is optional and may contain up to 15 characters System Location Specifies the location of the switch The location is optional and may contain up to 30 characters System Contact Specifies the name of the network administrator responsible for managing the switch This contact name is optional and may contain up to 30 characters Click Apply From the main menu on the left side of the page click on Switch Info The Switch Information page is displayed See AT S109 Home Page on page 6 for more information From the main menu on the left side of the page select Save Configuration to Flash to permanently sa
35. uration of IP Address Subnet Mask and Gateway Address on page 9 to manually assign a subnet mask or DHCP Client Configuration on page 18 to activate the DHCP client Default Gateway This parameter displays the default gateway IP address Refer to Configuration of IP Address Subnet Mask and Gateway Address on page 9 to manually assign a gateway address or DHCP Client Configuration on page 18 to activate the DHCP client Automatic Network Features Section DHCP Mode This parameter displays the status of the DHCP client on the switch For information about setting this parameter refer to DHCP Client Configuration on page 18 29 How to Start an AT GS950 24 WEB Management Session Switch Reboot 30 Password Protection of Factory Reset You can reboot the AT GS950 24 switch by either pressing the front panel eco friendly switch between 5 to 9 seconds or by using the Normal reboot function provided in the AT S109 management software In addition to rebooting the switch you have the option to reset the AT GS950 24 switch configuration parameters to the original factory default settings There are two ways to accomplish this o Press the front panel ecofriendly button for more than 10 seconds and release it O Reboot the switch in the AT S109 management software and follow the procedures to reset to factory defaults See Switch Reboot on page 31 and Configure Factory Default Values
36. ve your changes How to Start an AT GS950 24 WEB Management Session User Name and Password Configuration Password protection is always enabled for access to the AT S109 Management software This section explains how to create new users names and passwords and how to modify or delete existing users for the web interface See the following sections o Add New User Name and Password on page 23 o Modify User Name and Password on page 24 o Delete User Name and Password on page 25 Add New User The default User Name and Password is manager and friend both Name anq Without the quotes To configure new User Name and Password information perform the following procedure Password 1 From the main menu on the left side of the page click the System folder The System folder expands 2 From the System folder select Administration The Administration Page is displayed See Figure 10 Administration User Name Maximum length is 12 Password Maximum length is 12 Confirm Password Add Index Username Password Action 1 manager TERS Modify Figure 10 Administration Page 3 To create a user name enter a user name in the box next to the User Name field You can enter a value of up to 12 alphanumeric characters The User Name field is case sensitive 23 How to Start an AT GS950 24 WEB Management Session 24 Modify User Name and Password To add a password that corre
37. y 34 Default Reset Feature 5 Click Apply The switch begins the reboot process You must wait approximately two minutes for the switch to complete the reboot process before you can re establish your management session and network traffic begins flowing normally again The factory default reset feature allows anyone to reset the switch to the factory default configuration You may disable this feature More details are available concerning Password Protection of Factory Reset on page 30 To disable the factory default reset feature perform the following procedure 1 From the main menu on the left side of the page select the Tools folder The Tools folder expands From the Tools folder select Reboot The Factory Default Reset Reboot Page is displayed See Figure 14 on page 32 Go to the Factory Default Reset section on the upper part of the page You will find a field called Factory Default Reset This selection allows you to reset the switch configuration to the factory default settings by using the Reboot procedures outlined in Configure Factory Default Values on page 32 Note The AT S109 Management software default values are listed in the AT GS950 Web User Guide To disable the factory default reset feature select Disable on the pull down menu of the Factory Default Reset field The Factory Default Reset Reboot Page changes to include fields for entering a password See Figure 15 Factory Defaul
Download Pdf Manuals
Related Search
Related Contents
Digitaler Anrufbeantworter Digital Answering Machine Samsung C6625 XBT F - Schneider Electric Vogel's PUC 2715 Pole 150cm, silver Manual de instalación, funcionamiento y logements aux besoins des locataires Samsung LS24C65UDW/EN Uporabniški priročnik New Bigfoot GAP User guide - V-Data Sprint Nextel BRUTE I686 User's Manual Copyright © All rights reserved.