Home
Allen & Heath AP5197 User's Manual
Contents
1. STATUS C 0 3 0 c c OS a Le ee ae CMW WW Ww a a Y Configuring the controls The faders switches and LED indicators are configured using the iDR System Manager software or iLive Surface or Editor software Note that the LEDs are 3 colour and can display green red yellow or off Refer also to the Help file that comes with the software ALLENGHEATH LED SOFTKEYS HHEN CM Cm 1 A Cm cm LED SOFTKEYS co co a a a ee E w OOOO FADER Further information visit the Allen amp Heath web site for information on the full PL product range www allen heath com If further assistance is required please contact Allen amp Heath technical support PL 6 User Guide AP5197 issue 4
2. Heath Ltd All rights reserved installation before switching the equipment on PL 6 User Guide AP5197 issue 4 Number of devices The maximum number of PL devices that can be connected depends on their type cable lengths and PL Anet Bus Speed Up to 22x PL 6 devices may be connected in an iDR system with the half soeed PL Anet Bus setting Fewer devices may be connected if long distances full bus speed or other PL types are also involved Long distances up to 300m 1000 and star point connection are possible if the optional PL 9 PL Anet hub is used Before starting please refer to the PL Combinations Calculator spreadsheet available on the A amp H web site ow 02 00000000 os 2222 OO OOOOOO PL Anet SERIAL NETWORK eo o om fo J O oJ ene 9 o ii WALL PLATES AND REMOTE CONTROLLERS IN OUT IN OUT C TERMINATION 000 10 OA 10 10 10 000 00 OIO 00 00 00 20 10 10 10 10 10 00 10 10 10 10 10 10 10 10 10 O10 J D PL Anet is the proprietary Allen amp Heath system for daisy chaining remote controllers It is an RS485 serial connection that uses CAT5 STP cable to communicate bet
3. ALLEN amp H EATH PL 6 Fader Remote AP5197 User Guide CE Introduction The PL 6 is one of several remote control devices available for the iDR 4 8 audio mix processor and iLive mixing systems It is part of the Allen amp Heath PL Series of wall plates and remote controllers It can be mounted into a plinth or custom furniture or used free standing A suitable template with cutting details is provided for custom application The PL 6 interfaces with the Allen amp Heath PL Anet serial port Multiple PL 6 units can be daisy chained together along with other PL Anet devices using CAT5 cable A terminator is provided for plugging into the last unit in the chain For information on the full range of PL products available visit http www allen heath com The PL 6 control and indicator functions are programmed using the iDR System Manager software or the iLive Surface TouchScreen or Editor software Space is provided next to the controls for custom labelling The PL 6 is ideal as a remote mix controller for example as a simple operator controlled fader panel in an installed sound system or as a personal musicians on stage mix controller with in ear monitors The installer can program the unit according to the requirements of the application providing the degree of control needed by the day to day operator 8 Faders can be configured individually for input output group or crosspoint level control or monitor level Minimum and maximum ranges can be s
4. TO AVOID DAMAGE ONLY CONNECT COMPATIBLE REMOTE CONTROL EQUIPMENT TO THE PL Anet PORT ALLEN amp HEATH PL 6 SERIAL NUMBER C Made in the UK by ALLEN amp HEATH LIMITED TERMINATOR NJ i PLUG AN5249 End of chain termination As with any RS485 system the last PL device needs to have a terminating resistor fitted to its output port The PL 6 is shipped with an RJ45 terminator plug with this resistor built in Plug the terminator into the last unit in the PL Anet chain If the PL 6 is the only unit connected make sure the terminator is plugged into its output port A Testing the wiring Before powering up the system make sure all the wiring is inspected and continuity tested This is important as wiring errors may result in damage to the equipment Powering up the PL system Ensure that the iDR 4 8 PL Anet port is active Its green active LED should be lit If not use the iDR System Manager software Communications Option menu to activate the port Plug in the PL Anet cable The screen will display icons on the right hand toolbar for each PL device it recognises Check that the PL 6 front panel status LED displays green If red or yellow is displayed then check for wiring or equipment faults
5. et 16 Switches arranged as two per fader can be configured as combinations of level up down mute toggle polarity toggle audio monitor select or preset recall 24 LED indicators arranged as three per fader can be configured as combinations of 3 colour signal meters mute status or preset related 3 colour LED indication Controls can be configured as unused if not required A single 3 colour Status LED displays PL Anet power and communication status Custom labels can be fitted into the recessed areas provided Recommended height is 6mm NOTE Check the Allen amp Heath web site for the latest version of iDR or iLive firmware and software www allen heath com IMPORTANT A Observe the local standards which may apply This product complies with the European to the installation regarding the grade of cable and Electromagnetic Compatibility directive 2004 108 EC installation methods NOTE Any changes or modifications to the equipment not approved by Allen amp Heath could void Do not install the equipment where it is the compliance of the equipment Whilst we believe subject to moisture heat vibration or excessive the information in this guide to be reliable we do not movement assume responsibility for inaccuracies We also reserve the right to make changes in the interest of further product development A Connect this equipment to the Allen amp Heath PL Anet port only Test for correct wiring and Copyright 2011 Allen amp
6. ween devices over long distances It requires a terminator at the last unit in the chain PL Anet only works with Allen amp Heath PL devices The connection includes 20V DC to power the connected devices The iDR 8 port is shown here ree DR LINK AUDIO IN AUDIO OUT ere e CAUTION 20V DC L DIGITAL EXPANDER I TO AVOID DAMAGE ONLY CONNECT COMPATIBLE REMOTE CONTROL EQUIPMENT TO THE PL ANET PORT Mounting into furniture Cutting template details are shown here for mounting the PL 6 into a plinth or other furniture Secure the unit in place using 4x fixing screws up to 3 5mm diameter 51 92 DIA 4 CUTOUT 170 5 A N 156 5 Allows 1mm clearance each side 225 Grounding The exposed metal panels are grounded through the PL Anet cable shield There are no dangerous voltages inside PL Anet connections Underside RJ45 ports are provided for connecting to PL Anet These are recessed so that the cables can be hidden from view The IN port connects to the previous unit in the chain The OUT port connects to the next unit or end of chain termination Use flame retardent CAT5 STP shielded twisted pair RJ45 cables IN PL Anet OUT K previous nex CAUTION 20V DC
Download Pdf Manuals
Related Search
Related Contents
HyperAuthor - e-Archivo Principal - Universidad Carlos III de Madrid For more information, please contact us Evoke-1S Bedienungsanleitung appendix xi cdap smart card user manual ficha técnica: dipacxon d/d Guide de l`utilisateur CENTRIX/EVENTIX USER`S MANUAL 西部地区 加グ",=ヨカ Maxtor 1 16 Channel Digital Video Recorder User's Manual Copyright © All rights reserved.