1. SECTION 4 Ducting CAUTION ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES 1 Connect the ducting to the fan s duct collar Figure 4 Secure in place using tape or screw clamp Always duct the fan to the outside through a wall or roof cap Ducting Y SECTION 5 Wiring CAUTION MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION CAUTION ALL ELECTRICAL CONNECTIONS MUST BE MADE IN ACCORDANCE WITH LOCAL CODES ORDINANCES OR NATIONAL ELECTRICAL CODE IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN NOTE This unit includes a side access panel for wiring that does not require the removal of the fan s blower assembly If you choose to wire the unit from the inside you will need to remove the blower assembly and internal wiring compartment Both methods are equally effective 1a External Wire Compartment Remove the wire compartment cover screw and place cover in a secure place Figure 5 Wire Compartment Cover 2 of 12 1b Internal Wire Compartment Remove the three screws holding the blower assembly in place and lift assembly out of housing Figure 6 Remove the wire compartment cover screw and place the cover in a secure place Figure 7 Screws Venturi Figure 6 NOTE If the fan motor plug is connected to the fan Wire housing receptacle unplug Compartment so
2. Instruction Safety Sheet 2 Choose the location for your fan To ensure the best air and sound performance it is recommended that the length of ducting and the number of elbows be kept to a minimum and that insulated hard ducting be used Larger duct sizes will reduce noise and airflow restrictions This fan will require at least 8 of clearance in the ceiling or wall and will mount through drywall up to 3 4 thick The fan mounts between 16 or 24 on center joists using the 4 provided mounting rails 3 Select the most convenient electrical knockout and remove using a straight blade screw driver S Figure 1 SECTION 2 pure New Construction 1 Install the rails on the housing and position the housing next to the joist Line up housing so that it will be flush with the finished ceiling Secure the ends of the rails with screws or nails not included to the joists and slide the housing into the final position Figure 2 SECTION 3 Existing Construction 1 Set housing in position between the joist and trace an outline onto the ceiling material Figure 3 Set housing aside and cut opening being careful not to cut or damage any electrical or other hidden utilities Install the rails on the housing and position the housing in the previously cut hole so that it is flush with the finished ceiling Secure the ends of the rails to the joists Figure 2 210572080 Rev A 8 05 WWW AIRKINGLIMITED COM
3. l aide Guide de d pannage Trouble Cause Possible Solution Sugg r e 1 Le ventilateur ne fonctionne pas lorsque Un fusible peut tre grill ou un disjoncteur Remplacer le fusible ou r initialiser le disjoncteur l interrupteur est a la position en marche peut tre d cle nch La fiche de raccord du moteur n est Couper l alimentation l unit Retirer la grille et brancher le moteur dans pas connect e le r ceptacle dans le cabinet Remettre l alimentation sur l unit 1c Le c blage n est pas raccord correctement Couper l alimentation de l unit V rifier que tous les fils sont raccord s 1d La moteur est terminee Remplacez la moteur 2 Le ventilateur fonctionne mais l air circule Obstruction dans les conduits d vacuation V rifier pour toute obstruction dans les conduits Les plus courantes sont plus lentement que la normale des nids d oiseau dans le chapeau de toit ou mural l o le ventilateur s vacue vers l ext rieur 3 Le ventilateur fonctionne de mani re plus 3a Le moteur est l che 3a Couper l alimentation l unit Retirer la grille et v rifier que toutes les bruyante que la normale vis sont compl tement serr es Remettre l alimentation sur l unit 3b L h lice du ventilateur frotte contre le cabinet de l unit 3b Appeler votre marchand pour un service 210572080 Rev 8 05 WWW AIRKINGLIMITED COM 10 of 12 GARANTIE LIMITEE Tous les produits fabriqu s
4. Certains Etats ne permettent pas de limitation sur la dur e de la garantie implicite ou l exclusion ou la limitation de dommages indirects ou accessoires ainsi ces limitations et exclusions peuvent ne pas s appliquer vous Cette garantie vous donne des droits l gaux sp cifiques et vous pouvez aussi avoir des droits qui varient d un Etat l autre et d une province l autre POUR DES PIECES OU DE L ASSISTANCE TECHNIQUE Veuillez appeler au 1 800 465 7300 DU LUNDI AU VENDREDI ENTRE 8 00 HRE ET 16 00 HRE HNE VEUILLEZ NE PAS RETOURNER CE PRODUIT A LENDROIT DE L ACHAT D ORIGINE R f rencer le type et le style du produit localis sur l tiquette l int rieur du produit lorsque vous appelez Pour plus d information veuillez visiter le site Web de Air King au www airkinglimited com Installateur Date d installation Endroit de l achat Num ro de mod le 210572080 Rev 8 05 WWW AIRKINGLIMITED COM 11 of 12 DIAGRAMME DES PIECES DE REMPLACEMENT de pi ce de pi ce Description de remplacement Cabinet du ventilateur 581202033 Traverses de Montage 581299002 Couvercle de Cable Externe 581202007 Vis 581999010 Vis 581999010 Joint Collet 581202029 Collet de M tal 585202002 Clapet 585202006 Bague 585202003 Barre 555202005 Ressort 555202004 Harnais de la Lumi re 581202034 Couvercle de Cable Interne 581202035 Vis 581999010 Harnais du Capuchon du Moteur AK80LSL 582202007 Harnais du Capuchon du M
5. ELECTRIQUES DANS L EAU AVERTISSEMENT PERMETTRE LAMPOULE DE SE REFROIDIR AVANT DE LA REPLACER 3 Remplacement de l ampoule d brancher l alimentation de l unit Enlever la grille en la tirant vers le bas et en pressant ensemble les ressorts de la grille pour d gager le b ti Figure 12 2 Installer la grille en pressant ensemble les deux extr mit s Ampoules Fluorescentes enlever les ampoules en des ressorts et en les installant dans les fentes du ch ssis balan ant vers l avant et l arri re tout en appliquant une du ventilateur Pousser la grille en position Figure 11 pression externe pour d gager l ampoule du socle Remplacer l ampoule avec le mod le 13W 02700 de Air King ou une ampoule compacte compatible d un maximum de 13 watts deux tiges tube quad allumage instantan sans scintillement Lumi re de Nuit d visser l ampoule de lumi re de nuit de son socle et la remplacer avec une ampoule de lumi re de nuit de type C7 d un maximum de 4 watts culot de type cand labre 3 Restaurer l alimentation et tester votre installation SECTION 7 Utilisation et entretien AVERTISSEMENT VOUS ASSURER QUE L ALIMENTATION Fi 12 EST COUPEE AU PANNEAU DE SERVICE AVANT DE COMMENCER igure L INSTALLATION 1 Nettoyage de la grille Retirer la grille et utiliser un d tergent doux tel que du liquide pour la vaisselle puis s cher
6. du compartiment pour le raccordement et replacer le couvercle du compartiment en le fixant avec la vis qui fut enlev e pr c demment SECTION 6 Compl tion de l installation 1 WWW AIRKINGLIMITED COM Si l assemblage de la soufflante du ventilateur a t enlev durant le processus de raccordement r installer la soufflante en inversant les instructions a l tape 1b de la Section 5 Cablage Brancher le cordon a raccordement rapide dans le r ceptacle Ce cordon ne s ajuste que d une seule fa on dans le r ceptacle Figure 9 Installer les deux ampoules fluorescentes incluses de 13 watts dans les socles de la lampe en alignant les tiges sur la base de l ampoule au socle du support de lampe en pressant vers le support de lampe jusqu ce que l ampoule se mette en place et qu il soit fermement appuy dans le socle du support de lampe Installer une ampoule de type C7 d un maximum de 4 watts culot de type cand labre de la lumi re de nuit non comprise dans le support de lampe lat ral Figure 10 9 of 12 d un chiffon doux NE JAMAIS UTILISER D ABRASIF OU DE POUDRE A RECURER S cher compl tement la grille avant de la r installer Pour r installer la grille vous r f rer la Section 6 Compl tion de l installation 2 Nettoyage de l assemblage du ventilateur nettoyer toutes les pi ces avec un chiffon sec ou passer d licatement l aspirateur dans le ventilateur NE JAMAIS IMMERGER DES PI CES
7. par Air King Limited sont garantis pour un an partir de la date d achat contre les d fauts de main d uvre et ou de mat riel De plus tous les ventilateurs vacuateurs chaufferettes combin s ventilateur lumi re et ou les chaufferettes et les hottes de cuisine sont garantis pour cing ann es partir de la date d achat contre les d fauts de main d uvre et ou de mat riel Cette garantie ne couvre pas de co ts de transport ou de main d uvre ou le co t de remplacement de composantes faisant partie d entretien de routine tels que Filtres graisse des hottes de cuisine filtres au charbon ou combin filtre graisse charbon ampoules lectriques de remplacement dans les hottes de cuisine ou les combin s ventilateur lumi re chaufferette pour salle de bain Aussi tout dommage ou d faillance caus par un abus une mauvaise utilisation une installation fautive ou un entretien incorrect ne sera pas couvert par cette garantie De mani re effectuer une r clamation sous cette garantie vous devez tre l acheteur original du produit Il vous sera exig de pr senter la facture d achat originale Air King qui d montrera La date d achat l endroit de l achat et le mod le achet Le manquement rencontrer ces exigences annulera votre garantie Air King ne sera pas tenu responsable de quelque blessure corporelle ou dommage la propri t ou l immeuble que ce soit caus directement ou indirectement par le produit
8. your warranty Air King will not be held responsible for any bodily injury or damages to personal property or real estate whether caused directly or indirectly by the product Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages and some states do not allow limitations on how long an implied warranty lasts so these exclusions or limitations may not apply to you This warranty gives you specific legal rights and you may have other rights which vary from state to state and province to province FOR PARTS OR TECHNICAL ASSISTANCE Please call 1 800 465 7300 MONDAY THROUGH FRIDAY BETWEEN THE HOURS OF 8 AM AND 4 00 PM EST PLEASE DO NOT RETURN PRODUCT TO PLACE OF PURCHASE Reference the type and style of product located on label inside of the product when you call For more information please visit our website wwwairkinglimited com Installer Installation Date Place of Purchase Model Number 210572080 Rev A 8 05 WWW AIRKINGLIMITED COM 5 of 12 REPLACEMENT PARTS DIAGRAM Description Replacemen Fan Housing 991202033 eins Description Replacement Part Mounting Rails 5512990 Reflector Support Bracket 991202036 02 External Wire Cover 5812020 Blower Wheel 992202003 07 Screw 5519990 Screw 982202002 Screw 5519990 Motor 992202001 Gasket Collar 5512020 Screw 55120
9. 2037 Metal Collar 5552020 13 Watt PLC Lamp Holder 581202038 Damper 989202006 Light Reflector 991202015 Bushing 9892020 Bushing 551202018 Rod 5552020 Clip 99120201 05 Spring 989202004 Lamp Harness 99120203 Light Harness 9912020 Screw 99120204 34 Internal Wire Cover 9912020 Glass Lens 55520200 Screw 5519990 Grill 99120202 alrlalRIRl8lwl o NJ oa cn 8 oo gt 38 Motor Cap Harness AK80LSL 9822020 Lens Clips 99120202 Motor Cap Harness AK100LSL 9822020 Grill Springs 99120200 Screw 5519990 Nuts 99120204 Blower Screws 9822020 2 x 13 Watt Ballast NINININININININININININ 99120204 Motor Plate 9822020 Outlet Gasket 99120204 05 oo MI oD 210572080 Rev A 8 05 Venturi 10 Ground Screw 55199900 9822020 WWW AIRKINGLIMITED COM 14 ga Ground Wire DIN COP RY DH AF OO CO ooN 55199900 6 of 12 INSTRUCTIONS IMPORTANTES MANUEL D OPERATION e e Mod les Z g Ventilateur d Evacuation AK80LSL AK100LSL Ventilation Products J Ventilateur d vacuation LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D ASSEMBLER INSTALLER OP RER O DE R PARER LE PRODUIT D CRIT PROTEGEZ VOUS MEME ET LES AU
10. 80 Rev A 8 05 WWW AIRKINGLIMITED COM 7 of 12 INSTRUCTIONS D INSTALLATION AVERTISSEMENT VOUS ASSURER QUE L ALIMENTATION EST COUPEE AU PANNEAU DE SERVICE AVANT DE COMMENCER L INSTALLATION SECTION 1 Pr paration du Ventilateur d vacuation 1 Sortir le ventilateur de sa boite et confirmer que toutes les pi ces sont pr sentes En plus du ventilateur d vacuation vous devriez avoir 1 Grille 1 Ensemble de clapet attach 4 Traverses de Montage 2 Ampoules Fluorescentes de 13 watts 1 Feuillet d instructions s curit 2 Choisir un emplacement pour votre ventilateur Pour assurer la meilleure performance du d bit d air et sonore il est recommand que la longueur des conduits et que le nombre de coudes soient gard s au minimum et que des conduits rigides isol s soient utilis s Ce ventilateur n cessitera au moins 20 3cm 8po de d gagement dans le plafond ou le mur et s installe au travers de cloison s che d une paisseur de jusqu 1 9cm 3 4po Le ventilateur s installe entre 40 6cm ou 61cm 16po ou 24po au centre des solives l aide des quatre 4 traverses de montage incluses 3 S lectionner l alv ole d fongable la mieux appropri e et l enlever l aide S d un tournevis lame plate Figure 1 SECTION 2 Nouvelle Construction Figure 1 1 Installer les traverses sur le ch ssis et positionner le ch ssis pr s de la solive Aligner le ch ssis pour qu il soit effleurement ave
11. E ELECTRIQUE RECOURREZ AUX SERVICES D UN ELECTRICIEN QUALIFIE REMARQUE cette unit poss de un panneau d acc s lat ral pour le c blage qui ne requiert pas l enl vement de l assemblage de la soufflante du ventilateur Si vous choisissez de raccorder l unit par l int rieur vous aurez besoin d enlever l assemblage de la soufflante et le compartiment de c blage int rieur Les deux m thodes sont galement efficaces 1a Compartiment de C blage Ext rieur enlever la vis du couvercle du compartiment c blage et mettre ce couvercle dans un endroit fiable Figure 5 WWW AIRKINGLIMITED COM 8 of 12 Couvercle du Compartiment de Cablage 1b Compartiment de Cablage Int rieur enlever les trois vis REMARQUE si le raccord du moteur de ventilateur est raccord au r ceptacle du ch ssis le d brancher afin que l assemblage de la soufflante soit compl tement enlev 2 210572080 Rev 8 05 retenant en place l assemblage de la soufflante et soulever pour sortir l assemblage hors du ch ssis Figure 6 Enlever la vis du couvercle du compartiment c blage et mettre ce couvercle dans un endroit fiable Figure 7 Venturi Figure 6 Couvercle du Compartiment de C blage Figure 7 Courir le c blage partir d un commutateur mural approuv et de capacit appropri e Un fil de neutre blanc un fil de mise la terre vert ou cuivre nu et trois fils vivants les fils n
12. IMPORTANT INSTRUCTIONS OPERATING MANUAL Models AK80LSL AK100LSL e e Ventilation Products g READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE INSTALL OPERATE OR MAINTAIN THE PRODUCT DESCRIBED PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND OR PROPERTY DAMAGE RETAIN INSTRUCTIONS FOR FUTURE REFERENCE GENERAL SAFETY INFORMATION When using electrical appliances basic precautions should always be followed to reduce the risk of fire electric shock and injury to person including the following Read all instructions before installing or using exhaust fan Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer Before servicing or cleaning the unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors This unit must be grounded To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit fasten a prominent warning device such as a tag to the service panel WARNING TO REDUCE THE
13. RISK OF FIRE ELECTRIC SHOCK 4 Installation work and electrical wiring must be done by DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL qualified person s in accordance with all applicable codes DEVICE and standards including fire related construction 5 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities CAUTION FOR GENERAL VENTILATING USE ONLY DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS 10 Acceptable for use over a bathtub or shower when installed in a GFCI protected branch circuit 11 NEVER place a switch where it can be reached from a tub or shower WARNING DO NOT USE IN KITCHENS SAVE THESE INSTRUCTIONS 210572080 Rev A 8 05 WWW AIRKINGLIMITED COM 1 of 12 INSTALLATION INSTRUCTIONS CAUTION MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION SECTION 1 Preparing the Exhaust Fan 1 Unpack fan from the carton and confirm that all pieces are present In addition to the exhaust fan you should have 1 Grill 1 Damper Assembly attached 4 Mounting Rails 2 13 Watt Fluorescent Bulbs 1
14. TRES EN OBSERVANT TOUTE L INFORMATION DE SECURITE FAILLIR A SE CONFORMER AUX INSTRUCTIONS PEUT RESULTER EN BLESSURE PERSONNELLE GRAVE ET OU EN DOMMAGE A LA PROPRIETE CONSERVER CES INSTRUCTIONS POUR REFERENCES FUTURES INSTRUCTIONS GENERALES DE SECURITE Lors de l utilisation d appareils lectriques des pr cautions de base doivent toujours tre suivies pour r duire les risques d incendie de choc lectrique et de blessures corporelles incluant ce qui suit 1 Bien lire toutes les instructions avant d installer ou d utiliser AVERTISSEMENT POUR USAGE DE VENTILATION le ventilateur d vacuation G N RALE EXCLUSIVEMENT NE PAS UTILISER POUR VACUER 2 Utiliser cette unit seulement de la mani re pour laquelle le DU MATERIEL ET DES VAPEURS DANGEREUSES OU EXPLOSIVES fabricant l a con u Si vous aviez des questions veuillez 6 Lors de coupe ou de per age des murs et plafonds ne pas contacter le fabricant f ae endommager le filage lectrique et autres utilit s cach es 3 Avant d effectuer un service ou de nettoyer l unit couper ne a f ee te a 7 Les ventilateurs avec conduits doivent toujours tre vacu s l alimentation lectrique dans le panneau de distribution et Pe ie f nu i ME vers l ext rieur verrouiller le dispositif de d connexion afin d viter que ne oe l alimentation ne revienne accidentellement Lorsque le 8 Cette unit doit tre mise la terre dispositif ne peut tre verrouill fixer so
15. c le plafond fini Fixer les extr mit s des traverses avec des clous ou des vis non comprises aux solives et glisser le ch ssis sa position finale Figure 2 Traverses de Montage SECTION 3 Construction Existante 1 Placer le ch ssis en position entre les solives et tracer un contour sur le mat riau du plafond Figure 3 Mettre le chassis de c t et d couper l ouverture en prenant soin de ne pas couper ou endommager des c bles lectriques 210572080 Rev 8 05 dissimul s ou autres utilit s Installer les traverses sur le ch ssis et positionner le ch ssis dans le trou perc pr c demment afin qu il soit effleurement avec le plafond fini Fixer les extr mit s des traverses aux solives Figure 2 SECTION 4 Conduits AVERTISSEMENT TOUS LES CONDUITS DOIVENT TRE CONFORMES AUX CODES DU BATIMENT LOCAUX ET NATIONAUX 1 Raccorder le conduit au collet de conduit du ventilateur Figure 4 Fixer en place l aide de ruban ou de serre joint Toujours vacuer le ventilateur vers l ext rieur au travers de chapeau mural ou de toit Conduits SECTION 5 C blage AVERTISSEMENT VOUS ASSURER QUE L ALIMENTATION EST COUPEE AU PANNEAU DE SERVICE AVANT DE COMMENCER L INSTALLATION AVERTISSEMENT TOUTES LES CONNEXIONS DOIVENT TRE FAITES EN CONFORMITE AVEC LES CODES ELECTRIQUES LOCAUX OU NATIONAUX SI VOUS N ETES PAS FAMILIER AVEC LES METHODES D INSTALLATION DE CABLAG
16. compartment cover securing with the screw that was removed earlier SECTION 6 Completing the Installation 1 Ifthe fan s blower assembly was removed during the wiring process reinstall the blower by reversing the directions in Step 1bin Section 5 Wiring 2 Plug the fan s quick connect motor cord into the receptacle This cord will only fit one way into the receptacle Figure 9 3 Install the two included 13 watt fluorescent bulbs into the lamp holders by lining up the pins on the bulb base to the socket of the lamp holder and pressing towards the lamp holder until the bulb snaps into place and is firmly seated in the lamp holder Install a 4 watt maximum type C7 candelabra base night light not included into the side lamp holder Figure 10 4 Install the grill by squeezing the two ends of the springs together and installing them up into the slots on the fan s housing Push the grill up into position Figure 11 3 of 12 CAUTION ALLOW BULBS TO COOL BEFORE REPLACING 3 Changing the Light Bulb Disconnect power to the unit Remove grill by pulling downward on grill and squeezing grill springs together to release from housing Figure 12 Flourescent Bulbs Remove bulbs by gently rocking bulb back and forth while applying outward pressure to release the bulb from the base Replace with Air King model 13W02700 or a compatible 13 watt maximum two pin quad tube insta
17. he roof cap or wall cap where the fan exhausts to the outside 3 Fan is operating louder than normal 3a Motor is loose 3a Turn off power to unit Remove grill and check that all screws are fully tightened Restore power to unit 3b Fan blade is hitting housing of unit 3b Call your dealer for service 210572080 Rev A 8 05 WWW AIRKINGLIMITED COM 4 of 12 LIMITED WARRANTY All products manufactured by Air King Limited are warranted for one year from the date of purchase against defects in workmanship and or material In addition all ventilating exhaust fans heaters combination fan lights and or heaters and range hoods are guaranteed for five years from the date of purchase against defects in workmanship and or material This warranty does not cover any labor or shipping costs or the cost of replacement components as part of routine maintenance such as range hood grease filters charcoal filters or combination charcoal grease filters replacement light bulbs in range hoods or bathroom fan light bulb heater combinations As well any damage or failure caused by abuse misuse abnormal usage faulty installation or improper maintenance will not be covered by this warranty In order to make a claim on this warranty you must be the original consumer of the product You will be required to present to Air King the original bill of sale showing date of purchase place of purchase and model purchased Failure to meet these requirements will void
18. lidement un avis 9 Pour viter des dommages aux roulements des moteurs et ou d avertissement tel qu une tiquette au panneau de des h lices bruyantes ou d s quilibr es emp cher la distribution poussi re de cloison s che poussi re de construction etc 4 Le travail d installation et le c blage lectrique doivent tre d atteindre l unit de puissance effectu s par une des personne s qualifi e s en conformit z avec tous les codes et normes applicables incluant la ae a a ECS Gana trale ot eae au Mendes VENTILATEUR AVEC UN R GULATEUR DE VITESSE LECTRONIQUE 5 De l air en quantit suffisante est requis pour la bonne combustion et l vacuation de gaz par le conduit chemin e 10 Acceptable pour utilisation au dessus d une baignoire ou provenant d quipement de br lage au combustible pour d une douche lorsque install dans un circuit prot g par un pr venir un refoulement Suivre les directives du fabricant disjoncteur de fuite de terre de l quipement de chauffage et les normes de s curit telles 11 que celles publi es par la National Fire Protection Association NFPA et de la American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE et de celles des AVERTISSEMENT NE PAS UTILISER DANS LES CUISINES autorit s locales du code NE JAMAIS placer un interrupteur un endroit qui puisse tre atteint de la baignoire ou de la douche CONSERVER CES INSTRUCTIONS 2105720
19. nt on flicker free compact fluorescent bulb Night Light Unscrew night light bulb from socket and replace with a 4 watt maximum type C7 candelabra base 5 Restore power and test your installation night light bulb SECTION 7 Use and Care CAUTION MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE SERVICING THE UNIT 1 Cleaning the Grill Remove grill and use a mild detergent such as dishwashing liquid and dry with a soft cloth NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS Completely dry grill before reinstalling Refer to instructions in Section 6 Finishing the Installation to reinstall grill 2 Cleaning the Fan Assembly Wipe all parts with a dry cloth or gently vacuum the fan NEVER IMMERSE ELECTRICAL PARTS IN WATER Troubleshooting Guide Trouble Probable Cause Suggested Remedy 1 Fan does not operate when the switch is on 1a A fuse may be blown or a circuit tripped 1a Replace fuse or reset circuit breaker 1b Connector plug from motor is not plugged in 1b Turn off power to unit Remove Grill and plug motor into receptacle in housing Restore power to unit 1c Wiring is not connected properly 1c Turn off power to unit Check that all wires are connected 1d Motor has stopped operating 1d Replace motor 2 Fan is operating but air moves slower than normal 2 Obstruction in the exhaust ducting 2 Check for any obstructions in the ducting The most common are bird nests in t
20. oir violet et jaune raccord s l interrupteur un pour chaque fonction Fixer les c bles lectriques au ch ssis l aide de connecteur lectrique approuv Vous assurer que vous laissez suffisamment de c ble dans la bo te pour permettre le raccordement au r ceptacle du ventilateur Par l o vous avez choisi d acc der la bo te de jonction du ventilateur raccorder un fil Blanc de la maison aux deux fils Blancs du ventilateur Raccorder un fil vivant Noir du commutateur mural au fil Noir du ventilateur celui ci est pour le contr le du ventilateur Raccorder le second fil vivant violet du commutateur mural au fil Violet du ventilateur celui ci est pour le contr le de la lumi re principale Raccorder un troisi me fil vivant Jaune du commutateur mural au fil Jaune du ventilateur celui ci pour le contr le de la lumi re de nuit Raccorder le fil de mise la terre de la maison au fil Vert du ventilateur Figure 8 Utiliser des m thodes de raccordement approuv es pour toutes les connexions Alimentation provenant de la r sidence ja Fil Chaud Violet Fil Chaud Jaune REMARQUE les fils du r ceptacle du ventilateur pourraient n cessiter d tre tir s l ext rieur du compartiment pour le raccordement Tirer uniquement les trois fils l ches l ext rieur du compartiment Des fils additionnels y sont pr sents 4 Regrouper soigneusement les fils l int rieur
21. oteur AK100LSL 582202012 Vis 581999009 Vis de la Soufflante 582202004 Plaque de Moteur 582202005 Venturi 552202006 D Description de remplacement Griffe de Support du R flecteur 591202036 Roue de la Soufflante 582202003 Vis 582202002 Moteur 582202001 Vis 581202037 Socle de Lampe PLC de 13 watts 581202038 R flecteur de la Lumi re 591202015 Bague 591202018 Clip 981202017 Harnais de la Lampe 591202039 0 Vis 581202040 Lentilles de Verre 585202001 Grille 581202020 Clip de Lentilles 991202021 Ressorts de la grille 591202006 Ecrou 581202041 2 x Ballasts de 13 watts 581202042 Joint Ext rieur 581202043 Vis 10 de mise a la terre 581999002 Fil de mise a la terre de calibre 14 581999003 Tl Bool MD S eo 0 NJ cn 8 co ro gt 38 S ro ro a a a ro ro no n oo MI oD 210572080 Rev A 8 05 WWW AIRKINGLIMITED COM 12 of 12
22. the blower assembly can un Cover be completely removed 2 Run wiring from an approved wall switch carrying the appropriate rating One neutral white one ground green or bare copper and three hot black purple yellow leads connected to the switch one for each function Secure the electrical wires to the housing with an approved electrical connector Make sure you leave enough wiring in the box to make the connection to the fan s receptacle 3 From where you have chosen to access the fan s junction box connect the White wire from the house to the two White wires from the fan Connect one Hot Black wire from the wall switch to the Black wire from the fan this is the fan control Connect second Hot Purple wire from the wall switch to the Purple wire from the fan this is the main light control Connect the third Hot Yellow wire from the wall switch to the Yellow wire from the fan this is the night light control Connect the ground wire from the house to the Green wire from the fan Figure 8 Use approved methods for all connections Supply from house Purple Ground Hot Yellow Figure 8 210572080 Rev A 8 05 WWW AIRKINGLIMITED COM NOTE The fan s receptacle wires might need to be pulled outside compartment for connection Only pull the three loose wires outside of compartment Additional wires will be present 4 Carefully tuck wires back inside wire compartment and replace wire