Aiphone PS-1225UL User's Manual
Contents
1.
2. PS 1225 MANUALEPM 0303 2 Al PHON E k DC POWER SUPPLY FOR INTERCOM Models PS 1225 wthoutAcpug PS 4225UL wvcsa Listed PS 12258S cE Listed This product is designed exclusively for use with Aiphone Intercom Systems INSTALLATION MANUAL PRECAUTIONS Q General prohibitions Prohibitions to dismantle the unit Q General precautions A WARNING Negligence could result in death or serious injury Do not connect the unit with any non specified power source Fire or electric shock could result 9 Do not connect any terminal on the unit to AC power lines O Keep AC cord away from being marred or crushed Fire or electric shock could result Do not plug or unplug with wet hands Electric shock could result Q Do not make the wires or DC output terminals shorted Fire or unit trouble could result Do not dismantle or alter the unit Fire or electric shock could result Keep AC plug away from moisture or dust Fire could result A CAUTION Negligence could result in injury or damage to property Do not install or make any wire terminations while power supply is plugged in it can cause electrical shock or damage to the unit Before plugging in the unit make sure the wires are not crossed or shorted It can cause fire or electric shock Do not install the unit in any of the following locations as it may cause the system to malfunction Ss High or extreme cold temperature areas under direct sunlight near equip
3. cts of material and workmanship und r normal use and service for a period of one year after delivery to the ultimate user and will repair free of charge or replace at no charge should it become defective upon which examination shalt disclose to be defective and under warranty Aiphone reserves unto itself the sole right to make the final decision whether there is a defect in materials and or workmanship and whether or not the product Is within the warranty This warranty shall not apply to any Aiphone product which has been subject to misuse neglect accident or to use in violation of instructions furnished nor extended to units which have been repaired or altered outside of the factory This warranty does not cover batteries or damage caused by batteries used in connection with the product This warranty covers bench repairs only and any repairs must be made at the shop or place designated in writing by Aiphone Aiphone will not be responsible for any costs incurred involving on site service calls ate FEEEHEE EEE sje ste ope ste ope spe ote spe opeope oe fe afe fee ope peapea ate aje ojo of afoobe ato ode fe ce e oe of she obese oe of of ole afoot nfo fe ake opo eje ete ate abe fe ote eto fe of abv ate oe abe abe ete oe oe ote afro IPHONE CO LTD NAGOYA JAPAN IPHONE CORPORATION BELLEVUE WA USA IPHONE EUROPE N V ANTWERP BELGIUM lt lt AIPHONE Providing Peace of Mind http www aiphone com Printed in Japan E
4. e Nominal voltage amp current rating amp current rating North American 120V 60Hz Universal 230V 50Hz 2A min European 2A min United Kingdom 230V 50Hz 2A min North American 240V 60Hz 2A min Australian 240V 50Hz 2A min UL LISTED MOUNTING Mount the power supply Attach mounting bracket to box or wall on mounting bracket z 83 5mm 8 5186 Single gang box or wall X X Screw or Wood screw x 2 D Plug AC cord into Connect DC wires socket securely observing polarity Connect grounding wire 2 BEFORE ASKING FOR REPAIRS if your intercom system does not work properly or malfunctions do not attempt to change or rectify wiring Ask qualified personnel If the system is not being used PS 1225 can be unplugged 3 SPECIFICATIONS Power source AC 100V 240V 50 60Hz Power consumption 37W 65 82VA Secondary output voltage DC 12V Secondary output current 2 54 Dimensions amp weight 167H x 90W x 52D mm 6 9 16 H x 3 9 16 W x 2 D Approx 430g 0 95 Ibs except AC cord Ambient temperature 0 C 40 C 82 F 104 F ae ofesfe she obo ofeofestostecfosfonte obese ste ofesfeateatectoofeateofe ate af oe obo apa of oe fe abe afeafe spe spe ate spe opo afo afe opr ole faoto abe abe ole ob ol ole oleate ete toate av abe oe oe oe be oe abe abe teete WARRANTY Aiphone warrants its products to be tree from defe
5. ment that varies in Wi Package contents temperature in front of air conditioner inside a refrigerated area etc Places subject to moisture or humidity extremes such as bathroom cellar greenhouse etc Power supply PS 1225 Places subject to environmental conditions such as dust oil chemicals salt etc PS 1225UL or PS 12258 AC cord amp plug except PS 1225 Mounting bracket e Packet of screws INSTALLATION MANUAL Places subject to constant vibration or impact Places subject to steam or smoke near heating equipment or cooking surfaces Places subject to direct rain or outdoors IMPORTANT In case your System and or Power Supply malfunctions or is in apparent trouble unplug the Power Supply from AC outlet o Protection cover forare 4 Ef Grounding terminal Type of plug varies by model AC cord inlet DC output terminals E AC cord requirements for PS 1225 Rating 125V 2A for use with 100 125V AC 250V 2A for use with 200 240V AC Cord length min 1 8m 6 max 2m 6 7 Type Must comply with requirements set out by the Safety Approval Certification Organization in each country of use AC cord inlet Specified EN60320 or equivalent Employ a plug in shape and ratings matched with AC outlet to be used AC cord AC cord Plug configuration Usage Nominal voltage Plug configuration Usag
Download Pdf Manuals
Related Search
Related Contents
Master Template 2.0 - User Guide CE TECH 29523 Installation Guide Microprocessors Lab Manual Please read manual carefully before starting PARIS - MODE D`EMPLOI (9782742435340) a pdf version here…. AvverTenze ImporTAnTI ImporTAnT SAFeGUArDS Cher Client, Merci d`avoir acheté un produit SOVEMA. uClinux on SmartFusion cSoC using ARM Cortex Foreign Student Resource Guide Copyright © All rights reserved.
Failed to retrieve file