Home

Aiphone NEW-5 User's Manual

image

Contents

1. gang box with the supplied two screws For surface wall mounting cut off either top or bottom section of chassis for cable inlet and attach the chassis to wall with the supplied two wood screws Cautions DO NOT CONNECT ANY TERMINAL ON ANY UNIT TO AC POWER LINES Be sure to unplug power supply from AC outlet before you open the unit or make wiring connections Avoid running the connecting wires through doors windows or desks which may pinch and disconnect the wires NEW 5 must be installed in as dry and dust free environment as possible SINGLE GANG BOX w mud ring When a sub station connected to NEW 5 adaptor places a call masters A amp B can be signalled simultaneously Upon being answered by either master the call is cancelled at the other master Master stations A amp B can select and call any sub connected to NEW 5 No priority Communication is established to the master who first answers the calling sub No break in on the communication between a master and a sub by the other master When master A is in communication with a sub connected to NEW 5 or when making an All call announcement the OCCUPIED LED transmit monitor LED lights up on Master B Master B can however call another sub simultaneously but there is a possibility that crosstalk may occur 7 All call function will override existing communications After the All call concludes the operation retur
2. 3819 100 py AIPHONE PARALLEL CALL ADAPTOR NEM Parallel call adaptor INSTRUCTIONS __ oh NEW 5 is a parallel call adaptor for use with Aiphone s NEM NEM A Type A system Calls from sub stations max 5 connected to NEW 5 can signal two masters simultaneously Rie ite S Sub Master A Je amp PS Power supply Button to open NEM NEM A Type A A etc c n Number of subs the front cover connected to NEW 5 PS 24C n Unit requirements Master station Use only Type A version of NEM NEM A masters for the parallel call application Sub stations All the standard subs can be connected to NEW 5 a c NEW 5 adaptor As shown above multiple numbers Master B n 4 5 wt z of NEW 5 max 8 can be connected per system each n E o NEW Se up to subs ere power a su suffices for max eight 5 RE gs a ree etc at E NB U BGM adaptor can oi be used in a system with pie ge men u En nE NEW 5 M ES NEM NEM A Type A eS Installation Be sure to connect all the terminals for both Masters A amp B If wiring to either Master is left undone or discon nected all the NEW S function will be dead The system will work even when power switch on either Master is turned off if only wiring to both masters is complete Wall mounting NEW 5 mounts on single gang box Open the front cover from the chassis pushing the button at the bottom Mount the chassis to single
3. become defective upon which examination shall disclose to be defective and under warranty Aiphone reserves unto itself the sole right to make the final decision whether there is a defect in materials and or workmanship and whether or not the product is within the warranty This warranty shall not apply to any Aiphone product which has been subject to misuse neglect accident or to use in violation of instructions furnished nor extended to units which have been repaired or altered outside of the factory This warranty does not cover batteries or damage caused by batteries used in connection with the product This warranty covers bench repairs only and any repairs must be made at the shop or place designated in writing by Aiphone Aiphone will not be responsible for any costs incurred involving on site service calls Aiphone Co Ltd Nagoya Japan INTERCOM SYSTEMS Aiphone Corporation Bellevue WA USA a Al SHON i HOME BUSINESS INDUSTRY Printed in Japan E NEW 5 I E 1089A
4. ns to normal When master A is making All call followed by master B s All call only the announcement of Master A will be heard at the subs connected to NEW S ON A BR WN m PARALLEL CALL ADAPTOR Run each 2 conductor cable individually NEW 2 S bs f Subs 2 mim NA A 1 wa a a A T S F ta NAA 2 NA A 5 oo Vin PS 12C R C NAA a E E E an E ane M A STER B ESR SEE F T NEM 10 MASTER A i marant LHILY NEM 10A NEM 10 IT f Type A NEM 10A Type A a ee PS 24C a PS 24C SUPPLY SUPPLY Subs Power source DC 12V Use a power supply PS 12C or PS 12A One power supply suffices for multiple numbers of NEW 5 adaptors Wiring 2 individual wires between NEW 5 and subs Wiring distance Between NEW 5 and subs Between NEW 5 and masters Diameter_ 0 65mm 0 8mm 1 0mm Diameter 0 65mm 0 8mm 1 0mm Between adaptor amp power supply Up to 50 with 20AWG 15m w 0 8 mm No of NEW 5 adaptor Max 8 adaptors per 40 call master Talk channel Separate communication channel for each master but with possibility of crosstalk Dimensions amp weight W x Hx D 155 x 230 x nny Sik x 9 1 16 x 1 11 16 Approx 550g 1 21 Ibs WARRANTY Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of one year after delivery to the ultimate user and will repair free of charge or replace at no charge should it

Download Pdf Manuals

image

Related Search

Related Contents

Alginet tissus    MT4 Hydra Trade Manager V.3.0 User Manual    Mark Levinson N 51 User's Manual  User manual: CXE180 Universal amplifier  Display Extender Audio & Skew  Trouver un emploi avec internet - ref.804  Sony XS-HF78 User's Manual  Behringer 1C User's Manual  

Copyright © All rights reserved.
Failed to retrieve file