Home
Aiphone HM-7 User's Manual
Contents
1. K4 2 BLACK wires PS 12S or PS 12C _ in North America BLACK wires Power Supply PS 712S or PS 12C in North America Power Supply CH B may be used in place of the CH BC whose color codes corre RED wire RED wire 2 BLACK wires es eee eee eee ed HM 7 ALL MASTER SYSTEM WITH 2 CH B DOOR STATIONS Selector button 6 on any master is to communicate with CH B door station 1 and selector button 7 with CH B door station 2 STATION STATION STATION STATION STATION Sees 1 2 3 4 12C in North America BLACK wires To EXISTING DOOR BELL BLACK Wires To EXISTING DOOR BELL REQUIRED Master station HM 7 also serves as a substation IF ALL MASTER CAPABILITY IS NOT In this illustration station 7 is allowed to call only station one However all other stations in the system may call station 7 Station selection wires may be omitted at any station to de velop a communication system to meet your requirements STATION STATION STATION STATION STATION STATION STATION 1 2 3 4 o T al 5 6 i ze PA l MASTER STATION INSTALLATION New Construction Provide 4 gang concrete box 4 gang plaster ring Or 4 gang plaster ring with box for installation of HM 7 master and install as shown Boxes and plaster rings are standard items available from most electrical supply houses Existing Construction Cut 3 x 7 1 4
2. wall mounting Plaster rings and or concrete boxes are available from almost all electrical supply outlets CH B door station can be surface mounted in standard l gang box and incorporates push button for operation of standard or existing door chime Chime system not included or supplied by Aiphone Electric lock switch can be used forremote control of door release Other remote functions such as switching of outside lights etc is possible using relay Relay not supplied nor manufactured by Aiphone COMPONENTS AVAILABLE EL 9S Electric door release Requires HM 7 7 call master station separate transformer B th tant door station oe eee PS 12C CSA amp UL approved power supply PG 3 3 watt paging amplifier Allows available only in North America paging from HM 7 master through a 8 ohm PS 12S Power supply for system Standard horn speaker everywhere except in North America INSTALLATION Do not attempt to install your intercom system until you have read and thoroughly understood the installation pro cedure Aiphone s warranty is void if system is installed in a manner other than described in this manual Lay out your system in advance Determine the exact location of each station We recommend that the maximum number of station locations be pre wired even though you may not initially be installing the maximum number of stations available to your system This way should you decide to add a sta
3. 80 mm x 190 mm opening into wall at desired location and insert provided mounting ring as shown INSTALLATION OF DOOR STATION CH B 1 Attach the unit to l gang box with the supplied 2 screws SX REMOVE l 2 When mounting to wall conductors may be pulled out either from top or IAN bottom of the back case As shown remove the outlet part of A nack E the case when passing conductors through the top 4 HM 7 ALL MASTER SYSTEM WITH TWO CH B DOOR STATIONS IN PARALLEL Selector button 7 on any master is to communicate with either CH B door station Communication between master and one door station can be heard at the other door station STATION STATION STATION STATION STATION 4 5 STATION STATION DOOR STATION CH B a0 oe PS 12C or PS 12S To EACH EXISTING BLACK DOOR BELL wires BLACK wires EL 9S PS 12S or AC PS 12C S Y POWER SUPPLY TRANSFORMER 8V TO 16V BY OTKERS 1 Gang box Connecting Screw x2 wires tilly 2 oe l Unial j an D Hal IO Connecting wires oe OPERATION OF MASTER STATION 2 CALL BY TONE CE Ae Calling aes 1 Depress the selector button of the desired station iced ead as a I 2 To call by tone momentarily depress both private and talk buttons 3 To call by voice depress talk button and speak 1 SELECT 4 To listen release talk button 5 Upon com
4. AIPHONE NAMES amp FUNCTIONS QADOQQE Speaker Microphone Directory card OFF button Station selector buttons ALL MASTER HOME INTERCOM SYSTEM MODELS HM 7 Master Station CH B Door Station INSTRUCTIONS FRONT VIEW SIDE VIEW REAR VIEW ae SO uie A IPHONE MODEL Hae 7 VOLUME ACTUAL HM 7 TERMINAL LOCATION Occupied lamp T for calling out and talking Door release button for receiving call and talking Mounting screws for power supply connection Volume control for on amp occupied lights D a Privacy button ON lamp E for connecting door station Talk button Connecting terminals L dry make contact for door release SPECIFICATIONS Power source DC 12 volt Use PS 12S AC adaptor PS 12C in North America Current consumption 500 mA maximum Station selection Push button station selection from each HM 7 master station Wiring Up to 14 conductors may be required Please refer to wiring diagram showing system that meets your requirements FEATURES All master system every HM 7 station can call every other station Open voice hands free communication at called station Up to 8 master stations or 7 master stations with up to 2 paralleled door stations can be connected Privacy switch on all master stations eliminates eavesdropping HM 7 masters fit standard 4 gang plaster ring or 4 gang concrete box for semi flush
5. YOUR INTERCOM STATIONS Your Aiphone intercom stations may be cleaned with a soft cloth dampened with household cleanser such as Mr Clean or Fantastik k k k We at AIPHONE are proud of our products Our designers and engineers strive to bring you the finest in communication equipment Each item has been carefully tested and inspected before leaving our factory Properly installed and used your Aiphone intercom system should give years of trouble free service We are pleas WARRANTY Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of one year after delivery to the ultimate user and will repair free of charge or replace at no charge should it become defective upon which examination shall disclose to be defective and under warranty Aiphone reserves unto itself the sole right to make the final decision whether there is a defect in materials and or workmanship and whether or not the prod uct is within the warranty This warranty shall not apply to any Aiphone product which has been subject to misuse neglect accident or to use in violation of instructions furnisheu nor extended to units which have been repaired or altered outside of the factory This warranty does not cover batteries or damage caused by batteries used in connection with the product This warranty covers bench repairs only and any repairs must be made at the shop or place d
6. es ignated in writing by Aiphone Aiphone will not be responsible for any costs incurred involving on site service calls ad Aiphone Co Ltd Nagoya Japan F Aiphone Corporation Bellevue Washington HM 71 0784 A PRINTED IN JAPAN E ss He Sait a aed is d biat Wwe fi ALL OVE
7. pleting conversation depress OFF button NOTE HM 7 master station OFF button when depressed puts station in standby position as well as OFF position OFF button MUST BE DEPRESSED on all master stations except station initiating a call or system will not work Receiving 1 Unless privacy switch is in depressed position no action is required and communication is hands free 2 With privacy switch in depressed position release same by momentarily depressing talk button then resuming hands free operation as above Monitoring _1 Depress selector button of the station you wish to monitor 2 Check room station to be monitored to insure privacy button is in off position Receiving call from door station 1 Door station signals call through home s chime door bell system 2 Depress door selector button at any master station 3 Operate talk button at master station for communication with door station Door station operation is hands free 4 For remote opening of door with optional EL 9S electric door lock depress door release button on master station TO PREVENT ELECTRIC SHOCK DO NOT CONNECT ANY TERMINAL ON ANY UNIT TO AC POWER LINES BE SURE TO REMOVE PLUG O PS 12S OR PS 12C FROM POWER OUTLET BEFORE YOU MAKE WIRING CONNECTIONS i Do not pinch connecting wires in windows doors or desks Do not spray water on the CH B unit HM 7 must be installed in as dry and dust free environment as possible CLEANING
8. tion later you can avoid running additional cables to exist ing stations WIRING REQUIRED HM 7 master stations a total of up to 14 conductors may be required CH B door station 4 conductors required 2 conductors from each door station connect to HM 7 master station system and 2 conductors connect to existing doorbell or doorbell supplied by others Refer to the chart below and select the proper wire gauge to meet your requirements AWG WIRE SIZE 24 AWG 400 DISTANCE 0 5 mm 120m DIAMETER OF WIRE DISTANCE 200 m 300 m 400 m 22 AWG 20 AWG 18 AWG 650 1000 1650 0 65 mm 0 8 mm NOTE Due to sensitivity of this system avoid running cable or mounting units in proximity of electrical wiring or dimmer controls HM 7 ALL MASTER SYSTEM STATION m STATION STATION STATION STATION STATION 3 a4 a6 ne 7 wW R 1 T E W R N G Cc 0 L o U R Cc o 0 E H E R E HM 7 ALL MASTER SYSTEM WITH ONE CH B DOOR STATION STATION STATION STATION STATION STATION STATION STATION Any master station may 2 4 re CH B CH BC 1 3 5 6 27 4 m E communicate with CH B door her ae station by selecting No 7 button cH Te ae 4 a 20 z o DOOR STATION m7 y CH 8 ela y i taalo DARM Or perre d as follows EET spond as follows 2 D 2 2 2 R Terminal O ie y ee ke Terminal E i Trasi R R RS i ac pni ja