Home

Aiphone GF-SW User's Manual

image

Contents

1. 10 C 60 C 14 F 140 F GF BC 0 C 40 C 32 F 104 F GF 1D 0 C 40 C 32 F 104 F Rain hood option GF Entrance station is weather resistant but for best results it should be protected from direct weather conditions Install a rain hood GF H to protect it from direct rainfall Filling in name amp Fill in directory or address on the transparent plate with an oil soluble pen etc and attach the address plate to mocure z e Plate 1 or paper Plate or paper Pressing on either side a i Pressing on either side abe goz ape anat plate Lehi address plate or Gae T 5 g Setting up after In case an apartment station is replaced after all the wiring is done turn the power switch off replacement and back on again on GF BC Then reprogram that apartment station only Operations At the end of communication hang up the handset on cradle If a handset is off the hook call tone will still ring at two stations But for approx 45 sec after called the inside audio is activated on that apartment station and heard at the entrance Momentarily hang up handset and resume communication While an apartment station rings with a call from an entrance station a call from the doorbell button will not be heard Cleaning Clean GF equipment with a soft cloth dampened with neutral household cleanser Never use any abrasive cleaner or cloth SPECIFICATIONS v Power source DC 24V GF BC supplied by PS 24ME or
2. DIN11 available from Aiphone HOW TO RESET BREAKER Power switch When system malfunctions check the wiring Check the fuse of power supply Turn off the power switch of GF BC and turn on again resetting the whole system operation So Green LED lit Apartment station Apartment 3 Apartment 1 Apartment 2 Chassis inside view 1 Doctor call Auto door strike upon visiting patient call in JP1 At the Apartment station remove JP1 jumper Press LIGHT button and see Call tone off indicator blinks Press LIGHT again to release Call tone off indicator goes out Note At the station set for Doctor NYA inlet hole pean ee call it is not possible to control EEE eke IES EE PELA a SR Ea Pe te oe J entrance light with LIGHT button l 2 Connect Doorbell Button only to fo Bus control unit either one of two apartment stations to avoid malfunction Junction point Provides dry closure contact for Employ a terminal block of adequate ringing while the Doorbell button size to distribute multiple Bus lines i held down gt gt to GF DA Speech Module Adjusting call tone volume or off MOUNTING Call tone volume can be adjusted to 3 positons It is suggested to mount the station at the height of 150cm 5 from the floor MUTED MID HIGH When the control is set to MUTED position Call tone off
3. a power supply as specified e Current consumption Max 700mA Standby 30mA 8 call one entrance v Call in tone Two types of call tones one from entrance station a other from doorbell button distinguishable e Talk path Single channel non open v Communication Simultaneous with handset no calling or communication between apartment stations Wiring 2 wires common Bus GF BC to Entrance station s amp Apartment stations via junction point throughout system e Type of Cable 2 conductors solid copper amp non braided polyethylene insulation 0 8mm dia 1 6mm dia 20AWG 14AWG ii al Junction point to GF 1D farthest 300m 980 Junction point to Entrance station 300m Total wiring distance 2500m 1 5 miles SEG to ower supy m MAWB to Sach GP DA light power supply 30m 980 Bus line capacity Multiple Bus lines divided at junction point e Apartment station max 50 on a Bus line s Entrance station max 3 on a Bus line Per system 150 pcs in total Apartment station ber apartment max 2 pcs Entrance station Per system max 5 pcs GF DA Per panel max 25 pcs GF SW Door release terminals EL EL rated less than 4A resistance load AC DC 24V for dry closure contact for door release A i a a a a i A a a a a a g eje WARRANTY Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period 4 Of one year a
4. 0801 A Ss Al PHONE TWO WIRE BUS APARTMENT SYSTEM GF SYSTEM INSTALLATION MANUAL This Manual is enclosed in GF BC Bus Control Unit box Operation Manual is enclosed in GF 1D Apartment Station box 1 GF DA amp GF DP Speech module amp Panel GF SW amp GF 1 4P Call SW module amp Panel Before actually installing the equipment the contents of this Manual must be thoroughly read and understood GF 2F or GF 3F 2 or 3 module Front frame GF 1D After installation please keep the GF BC Apartment station Installation Manual containing instructions for wiring amp programming as well as WARRANTY GF 2B or GF 3B Bus control unit or 3 module Back box OOOO OOOO ha Precautions on Installation amp Wiring A WARNING Negligence could result in death or serious injury to people AN CAUTION Negligence could result in injury to people or damage to property Q General Prohibitions 9 Prohibitions to subject the unit to water D Prohibitions to dismantle the unit ZN WARNING These devices are electrical Wiring must be performed by qualified personnel D Do not modify or alter the equipment Do not connect any power source other than specified to terminals Doing so may S cause fire or damage the unit The equipment must not be exposed to water or any other liquid 9 Make sure wires are connected properly before plugging the power supply into an electrical outlet S AC outlet mu
5. ONS ee Module back b bled Two module back boxes x2 Three module back boxes x3 mat ct Joint pipe ea 2 Back boxes W mm W inch One row 110 4 5 16 Joint pipe 2 Two rows 245 9 5 8 Three rows 380 15 Four rows 515 20 1 4 Five rows 650 25 9 16 Six rows 785 30 7 8 Seven rows 920 36 1 4 Eight rows 1055 41 9 16 pol spall ns gel Nine rows 1190 46 1 8 25mm 25mm For best results the back box es must be D 1 mounted strictly horizontally 44m 1 3 H d Key Mount back box EA sa than Mount back box not more than 15mm 1 2 in recess 15mm 1 2 in recess D MOUNTING ENTRANCE STATION e ATTACH Front frame amp panels Modules on bracket Joint pipe lt lt Se Assemble panels of speech amp Gall SW modules into front i frame from the back J Hexagonal wrench l supplied w GF BC seme eww ewww ew ew ww ew ww ew ew ew ew ew ew ew ew ew ew ew ew ew ew ew ew ew ew ew ew ew ew ew ew ew ew ew ew ew ew ew ew ew ew ew ew ew ew ew ew ew ew ee eB ew ee sexe e ewww m m m m m we wn ww ww ew ww ew ew ew ew ew ew ew ew ew ew ew ew m ew ew ew ew ew ew ew ew ew ew ew ew BM HW HK g Attach the Modules onto Plug the wires into connectors Mounting Bracket between the Modules L Always run the wire Connector under the plastic cover for drainage i Interconnecting Modules with Plug in Connectors As shown the Modules 1 Conn
6. as the door release button is held down Entrance station 2 GF DA Speech Module Back view to MAW B Light of Entrance 1 See page 5 for wiring U Ac Dc 24v gt AC DC 24V i i l less than 4A less than 4A AC LET Electric Door release 5P connector from upper socket of a module below an J resistance load T resistance load AC Electric Door release PT Power transformer Put a conductor into insert When mounting multiple rows of panels After wiring amp setting mount the lock terminals attach the metal plates and tighten screws on module mounted bracket to back box the brackets Fed oo front frame panel to To release a conductor Metal plat the bracket press UNLOCK button eal a then pull the conductor Mounting a ior a Light bracket es om Adjustable screw holes UNLOCK button J Hexagonal wrench To next apartmens APARTMENT See next page To next apartmens Q AC power line CONTROL i AC 230V input UNIT amp Tih e POWER JOO SUPPLY DC 24V 0 9A output Red Black white DH Blu nw aoe Option unused 3 MAW B Relay Light control Orange Orange lt TIMER For controlling light at the entrance AC use Aiphone s MAW B relay which provides dry closure contact MOUNTING Screw hole switch Power on LED DIN rail Pull down lever 5 gt DIN rail for GF BC W
7. ation channel is established with Entrance station instantly Hearing single BEEP tone means the station correctly set Hang up handset Apartment station 1 Entrance station BEEP TONE k w o K ST gt T J gt 5 D 3 3 D BEEP tone LIGHT button is set Turns on entrance light controlled by MAW B relay Hexagonal wrench Press a first call button Fora second station if installed lift second handset and press the same call button 1 Beep tone sounds twice Second Apartment station 1 Entrance station DOUBLE BEEP TONE Hexagonal wrench D Press a first call button TE Step 3 Go to each apartment consecutively and program each handset station in the same manner as in Step 2 Step 4 when completed press PROGRAM switch on Do not forget to replace GF DA Speech Module again to finish the MN N the rubber cap JM lt Mi 0 programming y T 2 i To correct wrong setting Apartment station Entrance station Lift handset Keep pressing a call button to clear until a continuous tone is heard Consecutively operate same way for next call button if any OUDER Following Step 2 Reset on apartment station s that have been cleared For 2 station apartment Clearing a call button cancels programming for two stations correctly set or not Individually reprogram both stations TECHNICAL PRECAUTIONS Temperature GF Entrance station
8. ect the Modules 2 Pass the connecting wire through joint pipe pre must be connected in a as shown in drawings opened and plug to CN1 of Call SW of next row daisy chained manner EE Speech module Back view S CN4 Call SW modules CNT Call SW CN2 modules l 2 CN1 CN2 Back view Locating Speech module GF DA in the middle row GF C 80cm 3 1 8 connecting wire In advance pass a 80cm 3 1 8 long connecting wire through joint pipes wee ee eee ee ee ee ee ee ee m ee ew ee ew ee ew m ee ew ee m ee m ee ee ee ee ew ee m m m ee m ee ee ee ee ew ee ew ee ee ee ew MOUNTING amp WIRING GF Entrance Station SETTING Entrance SET switches To set for Entrance stations 1 5 set DIP switches on Speech Module GF DA as shown below All the Entrance stations will malfunction if positioned in any other manner Entrance station 1 Entrance station 2 Entrance station 3 Entrance station 4 Entrance station 5 Entrance station 1 GF DA Speech Module Shipped in 1 position Back view Door release timer Mid point Momentary 20 range 0 5 M Shipped in Momentary position 0 5 sec duration Turn counterclockwise completely re Turn clockwise to obtain longer second 0 5 20 sec duration ot duration 20 sec duration Turn up to the mid point Momentary activation Turn to any point between 20 M Activated as long
9. fter delivery to the ultimate user and will repair free of charge or replace at no charge should it become defective upon which examination shall disclose to be defective and under warranty Aiphone reserves unto itself the sole right to make the final decision whether there is a defect in materials and or workmanship and whether or not the product is within the warranty This warranty shall not apply to any Aiphone product which has been subject to misuse neglect accident or to use in violation of instructions furnished nor extended to units which have been repaired or altered outside of the factory 4 This warranty does not cover batteries or damage caused by batteries used in connection with the unit 4 This warranty covers bench repairs only and any repairs must be made at the shop or place designated in writing by Aiphone Ke Aiphone will not be responsible for any costs incurred involving on site service calls ojo da ofe of ote fe dr ote ofe ofe ofe ofo dr ofo ofo ofe dr ofo ole ofe d sfe d ote ole ofo ole ofe dr ofe ofo dr of ofo ole d ofo d of ofo dr fe ofe d ofo d of d dr ofe dr d ofo d fe fe d ofe d dr d ofe d AIPHONE CO LTD NAGOYA JAPAN AIPHONE CORPORATION BELLEVUE WA USA 0 Al PHON E AIPHONE EUROPE N V ANTWERP BELGIUM Providing Peace of Mind GF I M E 0801A 8 Printed in Thailand E Station capacity ELEEEEEREEEEEE EES
10. indicator blinks 1 Cable Notes 1 Cut out a hole for surface Call tone volume Handset cable run control 2 SERVICE button terminal block amp switch is optional 83 5mm 3 To avoid pinching keep wires 3 5 16 away from PC board section MUTED MID gt HIGH Bottom view Loosen a screw on front case Lift the front case off the chassis and pull it away Mount chassis on an electrical box Connect incoming wires on terminal block Remount front case on chassis tightening the screw SETTING UP SYSTEM Prior to setting up GF system make sure all the stations have been installed and wired in proper manner Leave the front frame amp module panels unattached Step 1 Press PROGRAM switch on GF DA Speech Module uan the rubber cap Then push Pee E pe eee PROGRAM SW momentarily When front panels are already mounted open unscrewing the bottom screw Turn on power switch of GF BC Power switch Breaker SETTING FOR LIGHT button OPTION In use LED In use LED Wait for approx 15 sec and see the LED steadily lit soi Pi Blinks for aAa 15 sec ee R a E TA T T aX u nse on b a L While In use blinks within 15 sec press an assigned call button Unscrew Hexagonal wrench L m m m me em em ew ew ew ew ew ew ee m ee eee m m m the in use LED is steadily lit and blocks out any calling Step 2 At an Apartment station 1 lift handset Communic
11. ply PS 2410LD AC 230V Relay for Packet of screws Packet of screws Packet of screws external light OPERATION MANUAL INSTALLATION MANUAL e DIN ra aeee Hexagonal wrench La cover S Fuse Entrance station FRONT FRAME MODULE GF DP GF DA Panel only Speech module Connector GF 3B GF 3F 3 module back box 3 module front frame Packet of screws Mounting bracket GF 1P GF 2P Joint pipe x 2 Packet of screws 1 call button panel 2 call button panel Metal plate Do not discard GF SW Call switch module Directory card plate amp paper Connector GF 4P e Weather stripping for reinforcement 3 call button panel 4 call button panel GF 2F 2 module front frame I Weather stripping for reinforcement GF BP GF AP GF AD Packet of screws i pal eaaeo 2 module back box OPTION gt Blank panel Address panel Address module ee ppe x2 GF H Rain hood ee ea i n i ate aper GF C 80cm 3 1 8 Connector connecting wire Do not discard wee ew ew ee ew m m m ee m ee ew ee ee ee eK KH d Open a hole in the wall for mounting back box es It is suggested to mount the back box at the height of 150cm 5 up to box center Allow a space of 2mm 1 8 or more on each side of back box in the wall BACK BOX DIMENSI
12. st be away from moisture and dust S Z CAUTION Do not install or make any wire terminations while power supply is plugged in or it could cause S electrical shock or damage the unit Mount the intercom on wall in a convenient location but not where it could be bumped or jarred Do not install the unit in any of the following locations as it may cause the system to malfunction High or extreme cold temperature area under direct sunlight near equipment that varies in temperature in front of air conditioner inside a refrigerated area etc Places subject to moisture or humidity extremes Places subject to environmental conditions such as oil dust chemicals salt etc Places subject to constant vibration or impact GENERAL PRECAUTIONS 1 The equipment except the entrance station is designed for indoor use only Do not install them outdoors 2 The system is not operable during a power failure 3 In areas where broadcasting station antennas are close by intercom system may be affected by radio frequency interference 4 Keep all wiring at least 30cm 1 away from AC100 240V wiring fluorescent lighting or dimmer switches Otherwise cross AC wiring at a 90 angle SYSTEM COMPONENTS galia station Bus control unit amp Power supply OPTION r OPTION Doorbell Button i GF 1D l GF BC PS 24ME E AC 230V PS 2410LC AC 120V MAW B Apartment station Two wire Bus control unit Power sup