Home
Agilent Technologies 11899A User's Manual
Contents
1. tions of the instrument power line switch o O The OFF symbols are used to mark the positions of the instru ment power line switch The CE mark is a reg istered trademark of the European Commu nity CE The CSA mark is a reg istered trademark of the Canadian Stan dards Association The C Tick mark is a registered trademark of the Australian Spec trum Management Agency This text denotes the instrument is an Industrial Scientific and Medical Group 1 Class A product ISM1 A Typographical Conven tions The following conventions are used in this book Key type for keys or text located on the keyboard or instrument Softkey type for key names that are displayed on the instru ment s screen Display type for words or characters displayed on the computer s screen or instru ment s display User type for words or charac ters that you type or enter Emphasis type for words or characters that emphasize some point or that are used as place holders for text that you type WARNING WARNING WARNING WARNING WARNING WARNING General Safety Considerations General Safety Considerations This product has been designed and tested in accordance with IEC Publica tion 61010 1 Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use and has been supplied in a safe condition The instruction documentation cont
2. 8120 4754 90 90 230 Part number shown for plug is the industry identifier for the plug only Number shown for cable is the Agilent Technologies part number for the complete cable including the plug 11 Returning the Instrument for Service Returning the Instrument for Service The instructions in this section show you how to properly return the instru ment for repair or calibration Always call the Agilent Technologies Instrument Support Center first to initiate service before returning your instrument to a service office This ensures that the repair or calibration can be properly tracked and that your instrument will be returned to you as quickly as possi ble Call this number regardless of where you are located Refer to Agilent Technologies Service Offices on page 15 for a list of service offices Agilent Technologies Instrument Support Center 800 403 0801 If the instrument is still under warranty or is covered by an Agilent Technolo gies maintenance contract it will be repaired under the terms of the warranty or contract the warranty is at the front of this manual If the instrument is no longer under warranty or is not covered by an Agilent Technologies mainte nance plan Agilent Technologies will notify you of the cost of the repair after examining the unit When an instrument is returned to a Agilent Technologies service office for servicing it must be adequately packaged and have a complete
3. Agilent 11899A Probe Power Supply Operating and Service Note For use with the Agilent Technologies 83400 series lightwave sources and receivers ede Agilent Technologies Copyright Agilent Technologies 2000 All Rights Reserved Repro duction adaptation or trans lation without prior written permission is prohibited except as allowed under copy right laws Agilent Part No 11899 90004 Printed in USA April 2000 Agilent Technologies Lightwave Division 1400 Fountaingrove Parkway Santa Rosa CA 95408 1799 USA 707 577 1400 Notice The information contained in this document is subject to change without notice Com panies names and data used in examples herein are ficti tious unless otherwise noted Agilent Technologies makes no warranty of any kind with regard to this material includ ing but not limited to the implied warranties of mer chantability and fitness for a particular purpose Agilent Technologies shall not be lia ble for errors contained herein or for incidental or conse quential damages in connec tion with the furnishing performance or use of this material Restricted Rights Legend Use duplication or disclo sure by the U S Government is subject to restrictions as set forth in subparagraph c 1 Gi of the Rights in Technical Data and Computer Software clause at DFARS 252 227 7013 for DOD agencies and sub paragraphs c 1 and c 2 of the Commercial Computer Soft
4. ains information and warnings that must be followed by the user to ensure safe operation and to maintain the product in a safe condition There are many points in the instrument which can if contacted cause personal injury Be extremely careful Any adjustments or service procedures that require operation of the instrument with protective covers removed should be performed only by trained service personnel These servicing instructions are for use by qualified personnel only To avoid electrical shock do not perform any servicing unless you are qualified to do so The opening of covers or removal of parts is likely to expose dangerous voltages Disconnect the Agilent 11899A from all voltage sources while it is being opened The power cords on system instruments are connected to internal capacitors that may remain live for five seconds after disconnecting the plug from its power supply If this instrument is not used as specified the protection provided by the equipment could be impaired This instrument must be used in a normal condition in which all means for protection are intact only To prevent electrical shock disconnect the Agilent 11899A from mains before cleaning Use a dry cloth or one slightly dampened with water to clean the external case parts Do not attempt to clean internally WARNING WARNING WARNING CAUTION CAUTION CAUTION CAUTION CAUTION Genera
5. cal contact or dust Instrument damage can result from using packaging materials other than the original materials Never use styrene pellets as packaging material They do not adequately cushion the instrument or prevent it from shifting in the carton They may also cause instrument damage by generating static electricity Pack the instrument in the original shipping containers Original materials are available through any Agilent Technologies office Or use the following guidelines e Wrap the instrument in antistatic plastic to reduce the possibility of damage caused by electrostatic discharge e For instruments weighing less than 54 kg 120 Ib use a double walled cor rugated cardboard carton of 159 kg 850 Ib test strength e The carton must be large enough to allow approximately 7 cm 3 inches on all sides of the instrument for packing material and strong enough to accom modate the weight of the instrument e Surround the equipment with approximately 7 cm 8 inches of packing ma terial to protect the instrument and prevent it from moving in the carton If packing foam is not available the best alternative is S D 240 Air Cap from 13 Returning the Instrument for Service Sealed Air Corporation Commerce California 90001 Air Cap looks like a plastic sheet filled with air bubbles Use the pink antistatic Air Cap to reduce static electricity Wrapping the instrument several times in this ma terial will prot
6. description of the failure symptoms attached When describing the failure please be as spe cific as possible about the nature of the problem Include copies of additional failure information such as the instrument failure settings data related to instrument failure and error messages along with the instrument being returned Preparing the instrument for shipping Write a complete description of the failure and attach it to the instrument Include any specific performance details related to the problem The following 12 CAUTION CAUTION Returning the Instrument for Service information should be returned with the instrument e Type of service required e Date instrument was returned for repair e Description of the problem e Whether problem is constant or intermittent e Whether instrument is temperature sensitive e Whether instrument is vibration sensitive e Instrument settings required to reproduce the problem e Performance data Company name and return address Name and phone number of technical contact person Model number of returned instrument Full serial number of returned instrument List of any accessories returned with instrument Cover all front or rear panel connectors that were originally covered when you first received the instrument Cover electrical connectors to protect sensitive components from electrostatic damage Cover optical connectors to protect them from damage due to physi
7. ect the instrument and prevent it from moving in the carton 4 Seal the carton with strong nylon adhesive tape 5 Mark the carton FRAGILE HANDLE WITH CARE 6 Retain copies of all shipping papers 14 Agilent Technologies Service Offices Agilent Technologies Service Offices Before returning an instrument for service call the Agilent Technologies Instrument Support Center at 800 403 0801 visit the Test and Measurement Web Sites by Country page at http Awww tm agilent com tmo country English index html or call one of the numbers listed below Agilent Technologies Service Numbers Austria Belgium Brazil China Denmark Finland France Germany India Italy Ireland Japan Korea Mexico Netherlands Norway Russia Spain Sweden Switzerland United Kingdom United States and Canada 01 25125 7171 32 2 778 37 71 11 7297 8600 86 10 6261 3819 45 99 12 88 398 10 855 2360 01 69 82 66 66 0180 524 6330 080 34 35788 39 02 9212 2701 01 615 8222 81 426 56 7832 82 2 3770 0419 5 258 4826 020 547 6463 22 73 5 7 59 7 095 797 3930 34 91 631 1213 08 5064 8700 01 735 7200 01 344 366666 800 403 0801 15
8. ght net 0 9 kg 2 b shipping 1 8 kg 4 Ib Power Cords Power Cords Cable Part Length Plug Type No Plug Description in cm Color Country 250V 8120 1351 Straight BS1363A 90 228 Gray United Kingdom Cyprus Nigeria 8120 1703 90 30 228 MigtGray imbabw R Singapore 250V 8120 1369 Straight NZSS198 ASC 79 200 Gray Australia New s Zealand 90 8120 0696 87 221 Mint Gray 8120 1689 Straight CEE7 Y11 79 200 Mint Gray East and West A o Europe Saudi 8120 1692 90 79 200 Mint Gray Arabia So Africa 8120 2857p Straight Shielded 79 200 Coco Brown India unpolarized in many nations 8120 1378 Straight NEMA5 15P 90 228 Jade Gray United States 8120 1521 90 90 228 Jade Gray Canada Mexico Philippines 8120 1992 Straight Medical UL544 96 244 Black Taiwan 250V 8120 2104 Straight SEV1011 79 200 Mint Gray Switzerland 8120 2296 1959 24507 79 200 Mint Gray PRE i SN Type 12 90 Part number shown for plug is the industry identifier for the plug only Number shown for cable is the Agilent Technologies part number for the complete cable including the plug 10 Power Cords Cable Part E Length Plug Type No Plug Description in cm Color Country 220V 8120 2956 Straight DHCK107 79 200 Mint Gray Denmark TE 8120 2957 90 79 200 Mint Gray 250V 8120 4211 Straight SABS164 79 200 Jade Gray Republic of South 8120 4600 90 79 200 aii India 100V 8120 4753 Straight MITI 90 230 Dark Gray Japan
9. l Safety Considerations This is a Safety Class 1 product provided with a protective earthing ground incorporated in the power cord The mains plug shall only be inserted in a socket outlet provided with a protective earth contact Any interruption of the protective conductor inside or outside of the product is likely to make the product dangerous Intentional interruption is prohibited No operator serviceable parts inside Refer servicing to qualified personnel To prevent electrical shock do not remove covers For continued protection against fire hazard replace line fuse only with same type and ratings type T 0 315A 250V for 100 120V operation and 0 16A 250V for 220 240V operation The use of other fuses or materials is prohibited Verify that the value of the line voltage fuse is correct e For 100 120V operation use an IEC 127 5x20 mm 0 315 A 250 V Agilent part number 2110 0449 e For 220 240V operation use an IEC 127 5x20 mm 0 16 A 250 V Agilent Technologies part number 2110 0448 Before switching on this instrument make sure that the line voltage selector switch is set to the line voltage of the power supply and the correct fuse is installed Assure the supply voltage is in the specified range This product is designed for use in Installation Category II and Pollution Degree 2 per IEC 1010 and 664 respectively VENTILATION REQUIREMENTS When installing the product in a cabinet the convection into and out of the
10. n or maintenance No other warranty is expressed or implied Agilent Technologies specifically dis claims the implied warranties of merchantability and fitness for a particular purpose Exclusive Remedies The remedies provided herein are buyer s sole and exclusive remedies Agilent Technolo gies shall not be liable for any direct indirect special inci dental or consequential dam ages whether based on contract tort or any other legal theory Safety Symbols CAUTION The caution sign denotes a hazard It calls attention to a procedure which if not cor rectly performed or adhered to could result in damage to or destruction of the product Do not proceed beyond a cau tion sign until the indicated conditions are fully under stood and met WARNING The warning sign denotes a hazard It calls attention to a procedure which if not cor rectly performed or adhered to could result in injury or loss of life Do not proceed beyond a warning sign until the indicated conditions are fully understood and met The instruction man A ual symbol The prod uct is marked with this warning symbol when it is necessary for the user to refer to the instructions in the manual The laser radiation symbol This warning symbol is marked on products which have a laser output The AC symbol is used to indicate the required nature of the line module input power The ON symbols are used to mark the posi
11. product must not be restricted The ambient temperature outside the cabinet must be less than the maximum operating temperature of the product by 4 C for every 100 watts dissipated in the cabinet If the total power dissipated in the cabinet is greater than 800 watts then forced convection must be used Always use the three prong ac power cord supplied with this instrument Failure to ensure adequate earth grounding by not using this cord may cause instrument damage Do not connect ac power until you have verified the line voltage is correct Damage to the equipment could result General Safety Considerations CAUTION This instrument has autoranging line voltage input Be sure the supply voltage is within the specified range Contents Contents The Agilent 11899A Probe Power Supply Ata Glance 7 Performance Characteristics 9 Power Cords 10 Returning the Instrument for Service 12 Agilent Technologies Service Offices 15 The Agilent 11899A Probe Power Supply At a Glance The Agilent 11899A Probe Power Supply At a Glance PROBE POWER SUPPLY GROUND GROUND DC OUT DC OUT 15V 12 6V 12 6V 15V The Agilent 11899A probe power supply provides regulated DC power at the front panel receptacles for operation of one or two probes The following prod ucts are compatible with the power supply e Agilent 85024A High Frequency Probe e Agilent 41800A Active Probe e Agilent 834XX family of light
12. ware Restricted Rights clause at FAR 52 227 19 for other agencies Warranty This Agilent Technologies instrument product is war ranted against defects in material and workmanship for a period of one year from date of shipment During the war ranty period Agilent Technol ogies will at its option either repair or replace products which prove to be defective For warranty service or repair this product must be returned to a service facility desig nated by Agilent Technolo gies Buyer shall prepay shipping charges to Agilent Technologies and Agilent Technologies shall pay ship ping charges to return the product to Buyer However Buyer shall pay all shipping charges duties and taxes for products returned to Agilent Technologies from another country Agilent Technologies war rants that its software and firmware designated by Agi lent Technologies for use with an instrument will execute its programming instructions when properly installed on that instrument Agilent Tech nologies does not warrant that the operation of the instru ment or software or firmware will be uninterrupted or error free Limitation of Warranty The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by Buyer Buyer supplied software or interfac ing unauthorized modifica tion or misuse operation outside of the environmental specifications for the product or improper site preparatio
13. wave sources and receivers One of the following options is required for operation in a particular country e Option 100 for 100 volt operation e Option 120 for 120 volt operation e Option 220 for 220 volt operation e Option 240 for 240 volt operation The Agilent 11899A Probe Power Supply At a Glance An extender cord Agilent 10131B can also be ordered to increase the length between the power supply and the probe This manual provides operating and service information for the probe power supply Perform all work at a static safe workstation Failure to protect against electrostatic discharge could result in damage to the instrument For informa tion on static safe workstations and protection against electrostatic discharge refer to the User s Guide for your Agilent Technologies 83400 series product Performance Characteristics Performance Characteristics The following table contains performance characteristics for the Agilent 11899A probe power supply These are not specifications but are pro vided as information useful in operating the power supply Probe Driving Capability 1 or 2 probes Power Output 12 6 volts 350 mA and 15 volts 500 mA male connectors Power Input 88 112 volts 50 60 Hz option 100 105 135 volts 50 60 Hz option 120 193 247 volts 50 60 Hz option 220 211 269 volts 50 60 Hz option 240 Dimensions 81 mm wide 65 mm high 121 mm long 3 2 in x 2 6 in x 4 8 in Wei
Download Pdf Manuals