Home

AEG 8160 D User's Manual

image

Contents

1. has switched off during operation Solution The hood is connected to the electricity supply Check that the fan speed control is set to 1 20r3 The fan speed is set high enough for the task The grease filters are clean The kitchen is adequately vented to allow the entry of fresh air If set up for recirculation check that the charcoal filter is still effective If set up for extraction check that the ducting and outlets are not blocked The safety cut out service has been tripped Turn off the hob and then wait for the device to reset If the hood has been installed below the heights indicated in the installation instructions the motor will cut out frequently which will damage the hood If after all these checks the problem persists contact your local Service Force Centre quoting the model and serial number Please note that it will be necessary to provide proof of purchase for any in guarantee service calls In guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a mechanical or electrical breakdown Service and spare parts Inthe event of your apppliance requiring service or if you wish to purchase spare parts contact your local AEG Service Force Centre by telephoning 08705 929 929 Your call will be automatically routed to the Service Centre covering your postcode area Please ensure that you have read the sect
2. the holes 2 x 8 mm Insert the rawl plugs 7 and hang the hood on the wall again Adjust it horizontally with the screws 8 and secure it with the screws 9 Mount the chimney holder 10 with the rawl plugs 12 and the screws 11 Be careful that it is centered over the hood and horizontally aligned Fitting for ducting S Connect a tube between the hood air outlet and the wall or roof exhaust channel Fix it with the tube clamps supplied Fitting for recirculation K Mount the recirculation spigot with the two screws supplied Mounting the chimney Place the chimney 15 and fix it to the top chimney holder with the two screws 16 supplied Lower the bottom part of the chimney 17 and fasten it to the top of the hood with two screws supplied Note that the top part of the chimney can be mounted with the side grids up or down For use as a recirculation hood it must be mounted with the grids upwards Fig 6 Fig 6 12 Fig 7 13 530 550 i l l 599 899 Electrichob 500mm Gashob 650mm l Ly Wall bracket A q Cite e o A o 370 8190D t l i Ni 350 8160D l l Electrichob 500mm Gas hob 650mm es Charcoalandoil 700m Fig 8 14 15 AEG Hausger te GmbH Postfach 1036 D 90327 N rnberg http www aeg hausgeraete de Copyright by AEG LIIH8C
3. 8160 D Cooker hood Operating and Installation Instructions Contents Safety instructions 240unssnnnnnnnnnnnnnnnnnnnnnnnn nam 2 Description of the cooker hood meennn 3 Using the cooker hood ur2222u422400nnnnnennnnnnnnnnnen nen 4 Maintenance and cleaning 4 nenn 5 Wat to d i ru een 7 Service and Spare Parts uicis 8 Customer Care cooooooccccccconoonnnnnccnonononnnnncnnnnnnonnncnnnnnn nono 8 Guarantee Conditions anionini 9 Technical data 0004s4ssnnn nennen 10 Installation ee naar 11 N Safety instructions These warnings are provided in the interest of your safety Ensure that you understand them all before installing or using the appliance Your safety is of paramount importance If you are unsure about any of these meanings or warnings contactthe Customer Care department Please retain this instruction book for future reference particularly if the appliance is sold or left to another person Installation and service e Any electrical installation of the cooker hood must be carried out by a qualified electrician and the hood itself must be installed by someone with experience Installation made by an unqualified person can lead to loss of function of the cooker hood and possible damage to person and and or property e The cooker hood must be at least 50 cm above electric hobs or electric ranges or at least 65 cm above gas burners or gas ranges
4. e Ensure that the power cable is not damaged during installation e The cooker hood is only in stand by mode unless the plug or the fuse is disconnected e Thecooker hood cannot be connected to flues of other appliances that run on energy sources other than electricity Please keep to the provisions of official directives regarding fume discharge Use of the cooker hood e This appliance is for domestic use only in a normal household e Never leave any deep frying melting fat paraffin or any other inflammable liquid unattended on the hob In the event of fire Immediately switch off the cooker hood and the cooker Note Cover the fire Never use water e Never do any flamb cooking underneath the cooker hood It can cause a fire Remember that overheated fat may spontaneously ignite Never leave the frying pan unattended e Itis essential that the grease filter is regularly cleaned to help avoid fat dripping on to the hot zone and causing a fire Read the section on Maintenance and Cleaning in the instruction book Disposal e Prevent accidents when disposing of your cooker hood Disconnect the power plug from the wall socket and cut the power cord at the hood inlet Contact your local authority for information on where to dispose of the cooker hood Description of the cooker hood Functions There are two possible systems e Extraction of air to the outside using an optional venting kit and evacuation duct e Recirculat
5. ental damage neglect faulty installation unauthorised modification or attempted repair commercial use or failure to observe requirements and recommendations set out in the instruction book This guarantee does not cover such parts as light bulbs removable glass ware or plastic 3 Should guarantee repairs be necessary the purchaser must inform the nearest customer service office manufacturer s service or authorised agent AEG reserves the right to stipulate the place of the repair i e the customer s home place of installation or AEG workshop 4 The guarantee or free replacement includes both labour and materials 5 Repairs carried out under guarantee do not extend the guarantee period for the appliance Parts removed during guarantee repairs become the property of AEG 6 The purchaser s statutory rights are not affected by this guarantee European Guarantee If you should move to another country within Europe then your guarantee moves with you to your new home subject to the following qualifications The guarantee starts from the date you first purchased your product The guarantee is for the same period and to the same extent for labour and parts as exist in the new country of use for this brand or range of products This guarantee relates to you an cannot be transferred to another user Your new home is within the European Community EC or European Free Trade Area The product is installed and used in accordance
6. ion What to do if as the engineer will make a charge if the fault is not a mechanical or electrical breakdown even the appliance is under warranty Please note that proof of purchase is required for in guarantee service calls Help us to help you Please determine your type of enquiry before writing or telephoning When you contact us we need to know e Your name e Address and post code e Telephone number e Clear and concise details of the fault e Name and model of the appliance e E number This information can be found on the rating plate which can be seen when the grease filters are removed Customer Care For general enquiries concerning your AEG appliances or for further information on AEG products please contact our Customer Care Department Customer Care Department AEG Domestic Appliances 55 77 High Street Slough Berkshire SL1 1DZ Tel 08705 350 350 Guarantee conditions Guarantee Conditions AEG offer the following guarantee to the first purchaser of this appliance 1 The guarantee is valid for 12 months commencing when the appliance is handed over to the first retail purchaser which must be verified by purchase invoice or similar documentation The guarantee does not cover commercial use 2 The guarantee covers all parts or components which fail due to faulty workmanship or faulty materials The guarantee does not cover appliances where defects or poor performance are due to misuse accid
7. ion using an optional carbon _ filter Accessories Fig 1 The following are included with the cooker hood e 1 Adaptor 150 125 mm e 2Tube clamps e 1 hood canopy complete with controls lighting and fan motor e 1 telescopic chimney stack formed by U shaped upper section and U shaped lower section 1 reduction flange 150 125 mm 1 recirculation spigot e 1 plastic bag containing 2 wall hooks to fix the canopy hood 1 wall bracket to fix the chimney rawl plugs screws and documentation The following can be ordered from your retailer e Carbon KF8 filter alternatively KFL 60 80 The carbon filter is to be used when the hood is connected to the recirculation mode Using the cooker hood The control panel Best results are obtained by using a low speed for normal conditions and high speed when odours are more concentrated The control panel has two switches one for the lamp and one for the fan enabling you to select one of three speeds Fig 2 Turn the hood on a few minutes before you start cooking then you will get an underpressure in the kitchen It should be left on after cooking for about 15 minutes or until allodours have disappeared 0123 D wb Correct ventilation Fig 2 If the cooker hood is to work correctly there must be an underpressure in the kitchen It is important to keep the kitchen windows closed and have a window in an adjacent room open Important to know Not applicable f
8. lues of other N appliances that run on energy sources other than electricity Please keep to the provisions of official directives regarding fume discharge Electrical connection The electric outlet should be placed inside the chimney The hood hasapower cable 100 cm with an earth connection and the rated voltage is 220 240 V Connect the hood to the mains supply via a double pole switch which has 3 mm minimum clearance between the contacts 220 240 V The following is valid in the United Kingdom only As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug proceed as follows the wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol or coloured green or green and yellow the wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black the wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red 11 Mounting the cooker hood Fig 7 Position the template on the wall and mark the position and drill the holes 2 x 8 mm Mount the two rawl plugs with the hooks 3 Hang the hood on the hooks and level it with the adjustment screws 4 Remove the grease filters 5 and mark forthe two screws 6 Remove the hood and drill
9. or recirculation Great care must be taken if the hood is used at the same time as a burner or fireplace e g gas diesel coal or wood heaters water heaters etc as the hood will expel air which is required by these other appliances Attend to it by opening a window The negative pressure in the room must not exceed 0 04 mbar to prevent fumes being drawn back into the room by the cooker hood Maintenance and cleaning Before doing any maintenance work on the hood disconnect it N from the main supply by disconnecting the plug from the wall socket or unscrewing the fuse Cleaning the hood Clean the outside ofthe hood using a damp cloth and a mild detergent Never use corrosive abrasive or flammable cleaning products Cleaning the grease filters Clean the filter every month or every other month according to how much the hood is used The cleaner the filters the more grease they collect Remove the filters by Fig 3 e Push the handle towards the rear of the hood e Pullthe filter down at the front on which the grease collects Clean the filter in hot water using adetergent or in a dishwasher Let the filter dry before putting it back Note that a dishwasher may discolour the filter Changing and cleaning the carbon filter Only applicable for recirculation The carbon filters absorb smells and odours Unlike other carbon filters the LONGLIFE KF8 carbon filter canbe cleaned and reactivated At normal
10. use the filter should be cleaned every second month The best way to clean the filter is in the dishwasher Use normal detergent and choose the highest temperature 65 C Wash the filter separately so that no food parts gets stuck on the filter and later causes bad odours To reactivate the carbon the filter should be dried in an oven for 10 minutes with a temperature of maximum 100 C The KFL 60 80 carbon filter can not be reactivated ithas to be changed after 6 8 months of normal use After approximately three years of use the KF8 filter should be replaced with a new as the odour reduction capacity will be reduced To remove the filter Fig 4 e Remove the grease filters Press the red buttons A lower the front of the carbon filter e Remove the carbon filter e Replace in reverse order Fig 4 Clean the filters regularly The grease that collects in the filters N and the duct could ignite if a hot plate is left on or if overheating occurs Changing the light Disconnect the cooker hood from the main supply before changing the light To change the light Fig 5 e Remove the the glass diffuser e Replace the old bulb with a new one of the same type e Refitthe glass diffuser Fig 5 What to do if If your appliance fails to work properly please carry outthe following checks Symptom The cooker hood will not start The cooker hood is not working effectively The cooker hood
11. with our instructions and is only used domestically i e a normal household The product is installed taking into account regulations in your new country Before you move please contact your nearest Customer Care Centre listed below to give them details of your new home They will then ensure that the local Service Organisation is aware of your move and able to look after you and your appliances France Senlis 33 0 44 62 29 29 Germany Nurnberg 49 0 911 323 2600 Italy Pordenone 39 0 1678 47053 Sweden Stockholm 46 0 8 738 7910 UK Slough 44 0 1753 219899 Technical data Model 8160 D Size Height 800 1350 mm Width 598 mm Depth 470mm Light Max 1x11 W PL Grease filter 2 pcs Voltage 220 240 V Total power 170 W Fuse Rating 13 Amp Extra accessories Carbon filter KF 8 LONGLIFE P nr 942 118 609 Carbon filter KFL 60 80 610 899 421 10 Installation Unpacking Check that the cooker hood is not damaged Transportation damages should immediately be reported to the transport company Damages faults and missing parts should immediately be reported to the retailer Dispose carefully of the packaging material so that it is out of the way of small children Position The cooker hood should be mounted freely hanging on the wall The cooker hood must be at least 50 cm above electric hobs or electric ranges or at least 65 cm above gas burners or gas ranges The cooker hood cannot be connected to f