ADTRAN 61175044L2-22B User's Manual
Contents
1. Disconnects battery pack from the system if the battery voltage falls below 40 VDC Prevents damage to batteries CIRCUIT BREAKE 3 amp circuit breaker Protects unit from over current Rocker button extends out from front panel when tripped Reset by pushing in on the rocker button An18 AWG or larger ground wire is required to connect additional ground connector to ground bus in customer equipment room ELECTRICAL SPECIFICATIO AC input 115 V nominal Range 90 to 132 VAC DC output 54 V 60 W average 100 W peak Battery charging 16 hr nominal 24 hr maximum TELECOMMUNICATIONS COD Battery discharge Up to 8 hours JOBAid 61175044L2 22B December 2002 Technical Support 1 888 4ADTRAN 1 888 423 8726 Copyright 2002 ADTRAN All Rights Reserved BATTERY BACKUP UNIT JOBAID 61175044L2 22B MOUNTING INSTRUCTIONS Unpack the Total Access 750 850 Battery Backup Unit and inspect for damage If damage is apparent refer to your carrier or supplier for remedy BATTERY BACKUP UNIT 1175044L2 1 N Note It is not necessary to remove the batteries during installation process CLEI SIMPBBBARA The battery box must be mounted with the following minimum clearances Top 9 for Total Access 750 850 Top 5 for Total Access 612 616 624 Left Side 5 Right Side 1 Bottom 3 AD 1175044 BATTERY p as Using the template provided mark and drill three pilot
2. C 1175044L2 BATTERY BACKUP The device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Changes or modifications not expressly approved by ADTRAN could void the user s authority to operate this equipment CAUTION During Total Access 750 wall installation position the chassis so front panels face up Note The connection for the Total Access 850 will be identical to the Total Access 750 54 VDC Output to Total Access 750 To Alarms AC DC Power Supply Battery Charging Unit P N 1175043Lx 1175044L2 BATTERY BACKUP 54 VDC Battery Charging Discharging Line AC Power Input CAUTION During wall installation position the Total Access 612 616 624 as shown in 61200624L1 19A AC Power Input JOBAid 61175044L2 22B December 2002 Technical Support 1 888 4ADTRAN 1 888 423 8726 Copyright 2002 ADTRAN All Rights Reserved
3. holes for 10 mounting screws Insert 10 x 3 4 flat head wood screws supplied into the three pilot holes leaving 1 16 space between the screw head and the backboard CAUTION Fully loaded Battery box weighs 30 Ibs 6 7 Remove the two closure screws on the battery box and open the cover Note Battery Backup Unit is designed for use with the Total Access 612 616 624 750 and 850 units Use a long shaft screwdriver to tighten the three support screws WARRANTY Warranty for Carrier Network products manufactured by ADTRAN and supplied under Buyer s order for use in the U S is ten 10 years except for batteries which carry manufacturer s warranty For a complete copy of ADTRAN s U S Carrier Network Equipment Warranty 877 457 5007 Document 414 TELECOMMUNICATIONS CODES hs CAUTION SUBJECT TO ELECTROSTATIC DAMAGE OR DECREASE IN RELIABILITY HANDLING PRECAUTIONS REQUIRED MAINTENANCE Life expectancy 3 5 years on standby use Battery performance is adversely affected by extreme emperatures Old barreries should be recycled Reference 60000120 36A for further information Mount the battery box on the three support screws on the backboard BATTERY SPECIFICATIONS Batteries 7 Amp hr 4 batteries per pack Case size 6 W x 3 3 4 Hx2 1 2 D Battery type Lead acid Voltage 54 VDC Backup Time Up to 8 hours Wire Gauge 18 AWG Preferred Temperature 68 F 20
4. AD AC DC POWER SUPPLY AND BATTERY CHARGER P N 1175043L1 CLEI SIMPAAAARA P N 1175043L2 CLEI SIMPAADARA P N 1175043L3 CLEI SIMPAAEARA 1175043Lx GRN OK YEL DISCHARGING YEL FAIL RED FAIL OFF FAIL OFF NOT CONNECTED Note The AC DC Power Supply and Battery Charger is designed for use with the Total Access 750 and 850 It is not used with the Total Access 612 616 624 units ha CAUTION SUBJECT TO ELECTROSTATIC DAMAGE OR DECREASE IN RELIABILITY HANDLING PRECAUTIONS REQUIRED 1 2 AC DC POWER SUPPLY AND BATTERY CHARGER MOUNTING INSTRUCTIONS Remove the Total Access 750 850 AC DC Power Supply ADTRAN P N 1175043Lx from the box and inspect for damage If damage is apparent contact your carrier or supplier Place the power supply with the power cord oriented downward Use four 6 x 3 8 machine screws supplied to mount the power supply to either side of the Total Access 750 850 shelf Note Threaded mounting holes are provided on both sides of the shelf Note For battery backup installations it is recommended to mount the power supply on the left side of the Total Access 750 850 shelf next to the battery cover hinge Note Alternatively the power supply can be mounted to the backboard with four 6 x 1 wood screws not supplied S ADRAN 1175043Lx OT He E130853 LISTED GRN OK YEL FAIL RED FAIL OFF FAIL GRN OK YEL DIS
5. CHARGING RED LOW OFF NOT CONNECTED The device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Changes or modifications not expressly approved by ADTRAN could void the user s authority to operate this equipment WARRANTY Warranty for Carrier Network products manufactured by ADTRAN and supplied under Buyer s order for use in the U S is ten 10 years For a complete copy of ADTRAN s U S Carrier Networks Equipment Warranty 877 457 5007 Document 414 JOBAID PRICING AND AVAILABILITY 800 827 0887 TECHNICAL SUPPORT 888 4ADTRAN RETURN FOR REPAIR 256 963 8722 61175044L2 22B STATUS LEDS AC Power Operation AC power only Battery Operation AC power supply or battery backup GREEN OK GREEN OK charging YELLOW Power Fail YELLOW Discharging RED Power Fail RED Low lt 40 V QO OFF Power Fail OFF Disconnected RELAYS Alarm Relay Provided for customer use Condition Alarm Relay Normal Open AC Power Failure Battery Backup engaged Cycles open closed once per second if AC voltage lt 88 Vrms at full load and battery backup is connected Battery voltage lt 45V Stays closed if voltage lt 45 VDC to indicate that battery is becoming depleted Battery Disconnect Relay