ADC RF Signal Management SignalOn Series User's Manual

image

Contents

1. SPEC SHEET SignalOn Series RF Signal Management 25 A A ee bz be chin ete fs Advanced broadband services are being developed and launched at an ever accelerating pace While these services vary they have one thing in common Whether it be high speed data video on demand or IP telephony broadband subscribers expect a reliable high quality experience at an affordable price ADC s SignalOn Series has been designed with these demanding service requirements in mind This next generation RF signal management platform provides unmatched density RF performance and reliability all at a competitive price With its patented hitless make before break attenuator circuit design maintaining your RF signal network has never been easier www adc com e 1 952 938 8080 1 800 366 3891 SignalOn Series RF Signal Management Typical Downstream Configuration Mln REIR ey ee ee 6 IRD Receiver IRD Receiver IRD Receiver gt HA A gt IRD Receiver C S E A ve 2 S T a Amplifiers lod o B ser BRERA ia g L y DE Taa oye PE Fiber outside plant to subscribers processors ae Ln rel us modulators C S gt C A E T IS Redundant Amplifiers E S with RF Switch CMTS for HSD VoIP C Combiner RW 7 S Splitter A Amplifier VOD servers Typical Upstream Configuration Ni A A Network q diagnostics test gear S A QPSK set top S contr
2. e Blind mate power bus connector with 8 Position 2 RU Powered Chassis gold on gold contacts requires no cabling front view e Chassis mounted AC DC and DC DC power supply options e Redundant powering with dual load shared power supplies for increased availability e External 24 Vdc powering option i 180 le Fo as 3 r g Ge m a reia v A e NEBS Level 3 compliant sE 8 Position 2 RU Powered Chassis rear view www adc com 1 952 938 8080 1 800 366 3891 SignalOn Series Actives Forward Path Amplitier Actives Amplitier Modules PERFORMANCE ATTRIBUTE Bandwidth Optimum RF input Minimum full gain Gain adjustment range Tilt adjustment range Gain flatness Return loss input and output ports Noise figure CTB1 cso1 IMD1 Monitor ports Power dissipation Operating temperature Dimensions Power connector Thermal shock Office vibration Mechanical shock Accelerated aging NEBS Ordering Information BNC connector 20 dB Forward Amplifier 50 1000 MHz 20 dBmV per channel 20 0 dB 10 1 dB in 0 5 dB steps 10 1 dB 50 MHz in 0 5 dB steps 0 4 dB from 50 to 870 MHz 0 5 dB from 870 to 1000 MHz 19 0 dB from 50 to 870 MHz 16 5 dB from 870 to 1000 MHz 7 3 dB from 50 to 870 MHz 7 6 dB from 870 to 1000 MHz 73 1 dB 81 7 dB 78 2 dB Amplifier front view 30 dB Forward Amplifier 50 1000 MHz 10 dBmV per channel 30 0 dB 10 1 dB in
3. 0 5 dB steps 10 1 dB 50 MHz in 0 5 dB steps 0 45 dB from 50 to 870 MHz 0 65 dB from 870 to 1000 MHz 18 0 dB from 50 to 870 MHz 15 0 dB from 870 to 1000 MHz 5 7 dB from 50 to 870 MHz 6 2 dB from 870 to 1000 MHz 78 9 dB 84 5 dB 83 7 dB 20 dB test point for both RF input and RF output 17W max O 50 degrees C 8 55 H x 1 67 W x 7 81 D gold on gold slide on contacts Meets MIL STD 202 Method 107 Meets GR 63 Core Section 5 4 2 Meets MIL STD 202 Method 213 Meets MIL STD 202 Method 108 Meets NEBS Level 3 Note Measured with 110 channel loading and optimum RF input level at full gain and no tilt Specifications are typical worst case numbers across the given frequency range unless otherwise noted and are subject to change without notice www adc com 1 952 938 8080 1 800 366 3891 www adc com SignalOn Series RF Signal Management Actives Power Supply Modules Description Power Supply Modules Specifications PERFORMANCE ATTRIBUTE Input voltage Efficiency Output voltage Output power Amplifiers supported Redundancy Operating temperature Dimensions Power connector Test points Fan Alarm relays TTL contacts NEBS Ordering Information AC DC 90 264 Vac 50 60 Hz 75 nominal 24 Vdc 5 200W 24 Vdc 8 33 Amps Up to nine 30 dB amplifiers Yes dual load sharing O 50 C 8 55 H x 1 67 W x 12 96 D gold on gold slide on contacts 24 Vdc output test poi
4. 80 1 800 366 3891 hoe SignalOn Series o RF Signal Management Ordering Information Splitter Combiner with Pad and Monitor Modules www adc com 1 952 938 8080 1 800 366 3891 SignalOn Series RF Signal Management Passives Directional Coupler Modules 5 MHz to 1 GHz Catalog Number _ N MD 4 Application Type R Rear narrowcast signal port Connector Type DC Value wpe Circuit Quantity Single circuit Triple circuit Directional Coupler Ordering Information Description Catalog Number Directional Coupler Modules www adc com 1 952 938 8080 1 800 366 3891 hoe SignalOn Series o RF Signal Management Passives Conditioning and Monitor Modules Features e Typically placed at the input to the forward path optical transmitter this module allows for conditioning and grooming of the RF signal gain and slope It is designed as 1 1 input to output with two MBB circuits in A series for pad and EQ placement q yy e 20 dB front facing monitor port e NEBS Level 3 compliant l Triple C 8 M F Connectors Ordering Information Description Catalog Number Conditioning and Monitor Modules triple circuit 20 dB O dB default BNC connector N MMB320FMO Attenuation Equalization Pad EQ Pad 20 dB monitor Conditioning and monitor module schematic www adc com 1 952 938 8080 1 800 366 3891 SignalOn Series RF Signal Manageme
5. N ACC LE 08 N ACC LE 09 N ACC LE 10 N ACC LE 11 N ACC LE 12 N ACC LE 13 2 OB plug in 3 dB plug in 4 dB plug in 5 dB plug in 6 dB plug in 7 dB plug in 8 dB plug in 9 dB plug in 10 dB plug in 11 dB plug in 12 dB plug in 13 dB plug in DC Power Upgrade Kits for N ACC PWRKIT 08B N ACC PWRKIT 20B 2 RU chassis used to power 8 position 5 RU chassis used to power 20 position Power Supply Accessories N ACC CBL DC DC N ACC FAN Power cord for power supply Fan replacement kit for power supply Module Conversion Kits to install 1 RF Worx passive module into SignalOn chassis N ACC BRKT RFW 2 RF Worx reverse amps into powered SignalOn chassis N ACC BRKT RA 1 SignalOn passive module into MAXNET chassis N AMCK 01 18 SignalOn passive modules into MAXNET Chassis N AMCK 18 Blank Module Covers N ACC BLANK 01 N ACC BLANK 02 Single blank panel cover Dual blank panel cover Bulkhead Testpoint Panels Single panel with 2 F 81 bulkhead connectors N MTPF2 Single panel with 2 F 81 bulkhead connectors N MTPF6 1 MAXNET is a trademark of ATX Networks Website www adc com From North America Call Toll Free 1 800 366 3891 e Outside of North America 1 952 938 8080 Fax 1 952 917 3237 e For a listing of ADC s global sales office locations please refer to our website ADC Telecommunications Inc P O Box 1101 Minneapolis Minnesota USA 55440 1101 Specifications published here are current as of
6. dules ADC s Return Path Amplifier was designed specifically to solve problems particular to your environment Providing greater density unparalleled cable management greater functionality and redundant powering the return path amplifier is part of the system approach to integrating all signal management functions in a common format and modular system To mount modules in SignalOn chassis use these amplifiers in conjunction with N ACC BRKT RA mounts 1 or 2 amps see page 16 Features e Fixed 22 dB e Low distortion characteristics e Low noise figure e 5 200 MHz bandwidth e Two 20 dB monitor ports input and output e BNC or F connectors e AC or DC powering e Power redundancy optional Ordering Information Reverse Path Amplifier Modules BNC connectors 57 prm UE rr WORX H dB AMP 5 200 MHI r 0 1 E Ko host y i af OT E PR 1 0 k PP ant Reverse Path Amplifier mm x 31 mm x 203 mm RFX AMP 22B 22 dB Fixed Gain www adc com 1 952 938 8080 225 x 1 2 x 8 0 RFX AMP 22F 1 800 366 3891 SignalOn Series RF Signal Management Accessories Ordering Information Description Cable Management Kits includes rack mount cable management rings 2 brackets 2 2 5 x 5 5 cable rings 4 brackets 4 2 5 x 5 5 cable rings Chassis Extender Brackets for 2 position chassis 23 rack 8 position chassis 23 rack 20 position chassis ETSI 21 rack Insert
7. g over a decade of RF amplifier design aMi experience ADC s SignalOn amplifiers have been engineered to meet these demanding service Amplifier requirements Featuring operation from 50 MHz to front view 1 GHz the amplifiers offer excellent performance and reliability SignalOn amplifiers and associated power supplies can be housed in the same chassis as the SignalOn passive products for increased design flexibility With its electronically variable gain and slope controls you can adjust signal levels in your network with no service downtime SignalOn amplifiers feature non service affecting gain and slope controls This capability along with the patented make before break attenuator pad 20 Position 5 RU Powered Chassis design of the splitters and combiners allow for with mixture of passive hitless RF signal adjustment critical for today s and active modules carrier class broadband service applications Features 7 W y CA A k e i J m N L J e Operation from 50 MHz to 1 GHz e GaAs technology with near 100 surface mount design for high performance 20 Position 5 RU Powered Chassis e Meets MIL 202 specs for quality and reliability rear view e Mounts in same SignalOn chassis as passive modules for maximum design flexibility e Digitally variable gain and slope control for non service affecting signal level adjustments e 20 dB monitor points on both input and output signals for testing and troubleshooting
8. his switch usually is less that 10 milliseconds Switch status failure LEDS and RF level bar graphs are mounted on the front panel of the switch module Switching threshold 3 dB or Dual RF Switch Module 6 dB and alarm contact closures are located on the rear of module Features e Continuous monitoring of primary and secondary e Detects both high and low power failures e User selectable switching threshold 3 dB or 6 dB e Fail over switching time lt 10 ms Easily configured for redundancy or A B switch applications Front panel bar graph display provides indication of RF power and switching threshold Indication of switch status provided by front o panel LED and rear terminal block contacts e Automatic switchback after A path is restored oo e Easily configured switching threshold levels via e Front panel LED status and dual power rear DIP switch level displays ieee o e One step calibration e Alarm contact for remote failure monitoring e Auto switch back feature to primary input e Available in BNC and F connector configurations Pace e Built in delay to prevent from false switching e Single or dual modules e Automatic or manual modes of operation e NEBS Level 3 compliant Ordering Information Description Catalog Number Redundant RF Switch Modules www adc com 1 952 938 8080 1 800 366 3891 SignalOn Series RF Signal Management Actives Reverse Path Amplitier Mo
9. ion Withdrawal Tools BNC insertion tool with 12 handle BNC insertion tool with 24 handle F connector insertion tool Terminating Plugs BNC terminating plug 75 Q 1 0 BNC high performance terminating plug 75 Q 1 F terminating plug 75 Q 1 0 F high performance terminating plug 75 Q 1 Attenuator Pads XX dB pads aty 25 replace XX with 00 through 26 1 5 dB pads 5 of each pad value total qty 25 6 10 dB pads 5 of each pad value total qty 25 11 15 dB pads 5 of each pad value total qty 25 16 20 dB pads 5 of each pad value total qty 25 21 25 dB pads 5 of each pad value total qty 25 3 6 9 12 15 dB pads 5 of each pad value total qty 25 0 3 9 12 15 dB pads 5 of each pad value total qty 25 75 Q termination pads qty 25 Kit Intended for 0 db default MBB modules MO modules Kit intended for 6 db default MBB modules M6 modules Catalog Number N ACMK 01P N ACMK 04P EB 17B EB 35B EB 87B BT2000 12 BT2000 24 SC FG BNC TP1 BNC TP2 CF TP1 CF TP2 N ACC AP XX N ACC AP S1 N ACC AP S2 N ACC AP S3 N ACC AP S4 N ACC AP S5 N ACC AP MO N ACC AP M6 N ACC TP 75 BNC Terminating Plugs BNC TP 1 and TP 2 CF TP 1 and TP 2 rs gt A F Terminating Plugs 1 952 938 8080 1 800 366 3891 www adc com SignalOn Series Accessories Ordering Information Description Catalog Number Equalizer Pads N ACC LE 02 N ACC LE 03 N ACC LE 04 N ACC LE 05 N ACC LE 06 N ACC LE 07
10. lp to limit overdriving active devices further downstream and will help limit transmitter laser clipping and overdriving of RF amplifiers in the distribution plant 1 952 938 8080 1 800 366 3891 hoe SignalOn Series o RF Signal Management Ordering Information Plain Splitter Combiner Modules BNC connector 2 1 plain N MPB12 4 1 plain N MPB14 8 1 plain N MPB18 3 x 2 1 plain N MPB32 2 x 4 1 plain N MPB24 F connector 2 1 plain N MPF12 4 1 plain N MPF14 8 1 plain N MPF18 3 x 2 1 plain N MPF32 2 x 4 1 plain N MPF24 BNC connector O dB default 2 1 combiner with monitor N MCB12MO 2 1 splitter with monitor N MSB12MO 2x4 1 combiner with monitor N MCB24MO 2x4 1 splitter with monitor N MSB24MO 2x4 1 splitter combiner with monitor N MXB24MO 3x2 1 combiner with monitor N MCB32MO 3x2 1 splitter with monitor N MSB32MO 4 1 combiner with monitor N MCB14MO 4 1 splitter with monitor N MSB14MO 8 1 combiner with monitor N MCB18MO 8 1 splitter with monitor N MSB18MO 6 dB default 2 1 combiner with monitor N MCB12M6 2 1 splitter with monitor N MSB12M6 2x4 1 combiner with monitor N MCB24M6 2x4 1 splitter with monitor N MSB24M6 2x4 1 splitter combiner with monitor N MXB24M6 3x2 1 combiner with monitor N MCB32M6 3x2 1 splitter with monitor N MSB32M6 4 1 combiner with monitor N MCB14M6 4 1 splitter with monitor N MSB14M6 8 1 combiner with monitor N MCB18M6 8 1 splitter with monitor N MSB18M6 www adc com 1 952 938 80
11. nt Passives L Band Satellite Splitter Modules 950 MHz to 2 15 GHz ADC s new L Band series satellite splitter modules are engineered for the highest performance in the 950 MHz to 2 15 GHz frequency range These plain splitter combiner modules feature dual port power passing capability for powering LNB All L Band modules are available with precision F or BNC connectors and are NEBS Level 3 compliant yuan i Catalog Number DE N ML ds Connector Type Configuration pe f t E K 6 Housed in a single module E L Band Satellite Splitter Ordering Information L Band Satellite Splitter Modules BNC connector 2 1 splitter 4 1 splitter 8 1 splitter 3x2 1 splitter 2x4 1 splitter F connector 2 1 splitter 4 1 splitter 8 1 spliter 3x2 1 splitter 2x4 1 splitter All L Band modules feature dual port power passing capability Pass Pass 1 1 2 3 2 4 Pass Pass 2 Way Splitter di 4 Way Splitter 00 Y On Un la UY N Pass 8 Way Splitter www adc com 1 952 938 8080 1 800 366 3891 SignalOn Series RF Signal Management Actives Introduction 9 8 i Today s broadband services require high quality a headend infrastructure that offers excellent performance reliability and design flexibility Furthermore your infrastructure solution should Gr maximize the uptime of carrier class services like a VoIP VOD and HSD as applications evolve and your network changes Leveragin
12. nts Field replaceable unit Fan fail output power fail Remote inhibit input power fail output power fail Meets NEBS Level 3 1 952 938 8080 E A d 48 Power Supply front view Catalog Number N MV48DC DC DC 36 72 Vdc nominal 80 nominal 24 Vdc 5 192W 24 Vdc 8 Amps Up to nine 30 dB amplifiers Yes dual load sharing O 50 C 8 55 H x 1 67 W x 12 96 D gold on gold slide on contacts 24 Vdc output test points Field replaceable unit Fan fail output power fail Remote inhibit input power fail output power fail Meets NEBS Level 3 1 800 366 3891 SignalOn Series RF Signal Management Actives RF Switch Modules The ADC SignalOn RF Switch Module RFSM is designed for use with the SignalOn 8 position or 20 position powered chassis All RF connections to the switch are made through standard 75 Q BNC or F connectors on the rear of the module All operating controls and indicators are located on the front panel with configuration controls located on the rear of the module The primary function of the module is to monitor the RF signal gain of the operating primary A input and switch to the backup B input if the gain of the primary path rises or falls below the pre set customer selected threshold Should the A input side go above or fall below the threshold of the unit the RFSM will rapidly switch the input trom the failed input to the secondary input T
13. ol network Fiber plant l from subscribers a IHE S TEO l C i E Sl Pe _ J C E CMTS for HSD VoIP C Combiner S Splitter A Amplifier VOD servers www adc com 1 952 938 8080 1 800 366 3891 SignalOn Series RF Signal Management Chassis l a R d l ka eis e a z a 32 Position 4 RU Drawer Catalog Number N C B n 4 Position 1 RU Chassis Power Kit Type 2 position chassis 1 RU black Active Chassis 20 position powered chassis 5 RU black N C20VYB 20 position powered chassis 5 RU NEBS N C20VY NEBS 8 position powered chassis 2 RU black N CO8HYB www adc com 1 952 938 8080 1 800 366 3891 www adc com SignalOn Series RF Signal Management Passives Introduction The SignalOn Series combined with the innovative cable management of the chassis provides engineers with a variety of products to simplity the RF signal management challenge Passives RF Splitter Combiner Modules 5 MHz to 1 GHz Catalog Number N M 0 TO Make Before Break Attenuation Module Type Plain splitter combiner C Combiner with pad monitor Configuration S Splitter with pad monitor X Splitter and combiner with pad monitor 2 x 4 1 module only Connector Type 3 x 2 1 and 2 x 4 1 housed in a single module Leave last two digits blank for plain modules Pad and Monitor Module with Make Before Break A
14. the date of publication of this document Because we are continuously improving our products ADC reserves the right to change specifications without prior notice At any time you may verify product specifications by contacting our headquarters office in Minneapolis ADC Telecommunications Inc views its patent portfolio as an important corporate asset and vigorously enforces its patents Products or features contained herein may be covered by one or more U S or foreign patents An Equal Opportunity Employer 102721AE 5 08 Revision 2008 2006 ADC Telecommunications Inc All Rights Reserved
15. ttenuation Plain Splitter Combiner Module Features e Industry s highest density with standard F and BNC connectors e Industry s best performance and specifications e Individual performance certificate shipped with every module e Patented make before break attenuator pad design for hitless signal balancing e Chassis supports both passive and active modules e Clear chassis door provides protection and clear view of modules e Clear attenuator pad covers and patented pad guides for simplitied maintenance e High quality precision F or BNC connectors e Designed to exceed NEBS requirements for grounding bonding e Independent EMI near and far field testing e Ten year warranty on all passive modules e Available in 1 RU 2 RU 4 RU and 5 RU chassis e NEBS Level 3 compliant Selection of default pad option for pand and monitor modules The make before break attenuation feature requires that a default attenuation padding value be chosen tor the module The two options are MO O dB loss on the splitter or combiner leg when attenuator pad is removed The MO option is used in systems where the attenuator pad values will range from O dB to 10 dB M6 6 dB loss on the splitter or combiner leg when attenuator pad is removed The M6 option is typically used in systems where the attenuator pad values range from 10 dB to 25 dB In this situation the additional 6 dB of loss that is placed in line when the pad is removed will he

Download Pdf Manuals

image

Related Search

Related Contents

GrandTec P498 User's Manual  SoundStation2W User Guide And Administrator Guide  用 户 须 知 - CkHealth.de  Fachrichtung Informationsmanagement und Informationstechnologie  user manual. - Roald S. Rossnes  OPERATING INSTRUCTIONS BLUE VANE SCORING EQUIPMENT  Hunter Engineering DSP9200 Specification Sheet  LES COMMANDES  CG-SSW24GTR CG-SSW16GTR 取扱説明書  Análise e Desenvolvimento de Sistema de Informação Fabril  