Home

Accusplit AX602M500DEC User's Manual

image

Contents

1. Elapsed time Repeat mode Ht fac an Time of day The upper line shows the programmable timer value initially set at 0 00 00 0 while the middle line displays the current timer counting Time of Day clock display is at the lower line of the dis play CR indicates the current timer operating mode while the timer cycle counter is located at the upper left of the display Before starting the timer enter a countdown time first Then press START SPLIT to start timer running When the timer counts down to zero a 38 Timer Mode Press MODE until you enter the Timer mode 3 count down operation modes are available on this stopwatch e Count down repeat CR e Count down stop CS e Count down then count up CU The timer is set at the factory to the count down repeat CR mode At entering timer mode the mode message TIMER will be shown for a sec ond before timer count mode is displayed 3 second beep beep sound will be generated for a timer setting within one minute 15 second beep beep sound for 1 minute to 10 minutes setting and 30 second beep beep sound for over 10 minutes Pressing any key will stop the beep sound Under CR operating mode the timer value will be reloaded and count down will start again The timer cycle counter will be increased by one and updated on the display Under CS operating mode the timer after count ing down to 0 00 007 will stay at 0 0
2. adjust Press RECALL S4 or MODE to exit from Alarm setting mode 15 16 17 Chronograph and Recall Mode Press MODE until you enter the Chrono mode nin Ain ne rn iu AAAS LIS Lin mr T AN Lu LL a0 nian nn AHHH The stopwatch can measure up to 19 hours 59 minutes 59 99 seconds When you enter the Chronograph mode the display format is as below 83 18 19 To take a current split or lap time press START SPLIT The display will look like this 0G 8 4335 mua Py STOP 4935 The number of split lap times taken are shown in the upper left corner The corresponding split and lap times are displayed on the upper and middle line Press START SPLIT again the next split lap time will be shown and the number of split lap time is updated The upper line shows the split time the middle line shows the lap time and the accumulated elapsed time is displayed on the lower line Whenever the stopwatch stops running the STOP indicator will be ON Press the button START SPLIT to start the stopwatch As it runs the current elapsed time is shown on the lower line Split 800 G 00 00 28 Split time counter Lap time its Cumulative time B02 OS oy SPLIT p n H mar ig The stopwatch can store up to 500 split lap times The split lap times are stored into the memory as you press START SPLIT to take each split lap time Meanwhile the
3. Chronograph Data Recall Mode Press RECALL in Chronograph mode to recall stored split lap time memories The mode message will be shown up for one to two seconds as mode message display is enabled RECALL The split and lap time will be displayed on the upper and the middle line respectively The lower line shows the elapsed time between start and this split Press RECALL again to view the average lap time Average Lap Time indicator RECALL 805 SPLIT nnn rr 13 Le Lt nny inn uu ud Note Press RECALL continually to review all the stored split lap times The sequence starts from the last record to the first record when the stopwatch is running and vice versa when the stopwatch has been stopped 28 29 005 0 00 ni mimi LUU UE man f nn Ml g uu Z 86 Note watch is still running so run time continues to advance RECALL RECALL RECALL 30 31 when watch returns to Recall indicator turns off regular Chronograph mode 805 G07 ii RECALL D0 42 68 SHG During memory recall you can press either START SPLIT or STOP RESET to exit from chrono recall mode and jump to the chrono start stop or lap state respectively B82 0 00 0948 nanny 185 RECALL ee HIB RBE og ems RY After recalling the first record press RECALL once more to exit from Recall mode and go back to chronograph mode The RECAL icon will
4. as below nn np year day month date hr min second During clock display press START SPLIT to switch between 12 hr and 24 hr display mode To toggle chime ON or OFF you can press STOP e RESET The bell icon will be ON or OFF corre spondingly Normal Time Setting Press and hold RECALL S1 for 2 seconds to enter setting mode The normal time setting starts with second The second digits will be flashing You can change the flashing digit by pressing START SPLIT S3 button To speed up the setting you can press and hold START SPLIT for longer than 2 seconds to activate fast set ting To select other digits press STOP RESET S2 button The setting order is Second Minute Hour Year Month Date month date m d or 12 13 date month d m Sound ON or OFF Contrast darkness of the digits default is 9 then back to Second and recycles again Note when the second is to be set press START e SPLIT to reset the second digits to zero At the end of setting press RECALL S4 or MODE to exit from the setting mode and back to Time of Day Display Display for Sound ON or OFF setting SOUnd On Let the current status be ON SOUnd Press START SPLIT to toggle Sound ON or OFF Display for contrast adjustment COntT Let the current contrast be 5 5 12 14 15 Alarm Time Mode Press MODE until you enter Alarm mode This mode is use
5. distance from the least significant digit to the most significant digit The distance can be set in the range 0 000 to 1999 999 km or ML using START SPLIT S3 Press RECALL S4 or MODE to exit from the setting mode As an example the distance is set at 400m oot RY 0 4 km 400m Stop indicator 50 51 Press START SPLIT to record more lap times and show different speeds Note that as the speed exceeds the value 1999 999 km hr or 1999 999 mph Err will be shown and no storage will be made for that record duc e uog START SPLIT EE LAP nnn uuc ut tg Speed Mode Running Press START SPLIT to start the Speed timer The STOP indicator is OFF The maximum time can be up to 19 hr 59 min 59 99 sec DIST KW While the timer is running press START SPLIT to record the lap time and the corresponding speed in km hr or mph will be displayed on the upper line The lap counter shown on the upper left corner will advance by one START SPLIT To stop the speed measurement press STOP e RESET to stop the timer G04 25 40 Re uuu 34 i 034823 92 53 Before starting again you can reset the timer by pressing STOP RESET Speed Mode after reset nn LU UU uF Note When you reset the Speed timer the speed measurement starts again from a reset state and all speed records in memory will be cleared pro vided that the st
6. lap and split time will be frozen for 5 seconds After this 5 second period the lap and split time will return to normal In addition the fastest lap the slowest lap and the averages of all laps will also be recorded As you press STOP RESET to stop the chronograph the last lap split time will also be stored provided that the last lap split time is not the first lap split time i 20 21 When there are 5 free memories left the icon FULL will blink to remind you of the nearly full situation Whenever the storage is full extra split lap times will not be stored into memory but will still be shown on the display Any fastest and slowest laps will not be stored The memory coun ter will flash as the extra split lap times are being displayed The icon FULL will be steadily ON The maximum memory counter value is 500 To stop the chronograph press STOP RESET The indicator STOP will come on again to show the status Press STOP RESET as the stopwatch stops to reset the stopwatch while the split lap times will be kept in memory When the stopwatch starts running from reset state all the lap memo ries will be cleared 20 22 23 Reset the chronograph to 00 then press STOP e RESET to cycle through the time base modes 1 100s Note the change by looking at the bottom of the display Time base indicator Change to the 1 1000 of a minute chronograph mode by pressing STOP RESET a
7. turn OFF RECALL DATA Mode Press MODE until you enter DATA mode The mode message DATA will be shown for one to two seconds before the number of free memories is to be shown FREE 95 LAP You can press START SPLIT to scroll through all segments The current segment will come first Segment indicator gt Date Time shows watch is in DATA mode Stamp for this split 32 33 The header consisting of the date time stamp will be shown The number of laps in the segment will appear in the upper left while the segment num ber is displayed in the middle left If the segment shown is not your desired segment press START e SPLIT to reach the desired segment The current segment will be accessed first then it will cycle back to the 1st then 2nd and so on When you have found the segment you want you can press RECALL button consecutively to read the lap records from the first to the last lap Number of laps in ae this segment uu i uF a0 55 Segment number 892 2 00 285 34 35 onds to activate Delete One function DELETE ONE will be shown in blinking and beep sound will be generated dELETE OnE A ready period of 2 seconds will be counted At the end of the ready period all the lap records of the corresponding segment will be erased and a long beep sound will be heard Then the display will show the next segment If you don t want to delete the records
8. 0 00 0 until you press STOP RESET to reload the timer value Under CU operating mode the timer after counting down to 0 00 00 0 will count up and stop at 19 59 59 9 40 41 How to set the timer Press and hold RECALL S1 for 2 seconds to activate timer setting Timer setting starts with second digits which are shown blinking You can press START SPLIT S3 to advance the flashing digits Or you can press STOP RESET S2 to select other digits The setting follows the sequence second minute hour and timer operating mode CR CS and CU NOTE You can only set Hour Minute and Seconds The 1 10 second cannot be set Press and hold RECALL BBY oan ogo nin for 2 seconds Timer p setting starts with second digits 40 42 43 Pacer Mode Press MODE until you enter the Pacer mode In the Pacer mode you can set the standard pacer speed from 5 to 240 beats per minute in the following values 5 10 20 30 40 50 60 80 100 120 150 180 200 240 In Pacer mode the display will be PACER P 5 5 beats per minute The digits are flashing to indicate that the pace count is ready for setting Press STOP RESET to select the pace count Once the desired pace count is selected press START SPLIT to confirm the 42 Press STOP RESET S2 to move to minute digits Press STOP RESET S2 further to go to hour digits Hour digits can be adjusted
9. A ee S ACCUSPLIT BAON nn renin re vn VE Cummulative ie ISL OS Nef time non fag H Current LALELE j Button Operation uu LAP time e MODE used to mn 757 11 curren change the watch s Wut I vt sacs operating mode START SPLIT used o5 i to start the timer or Button stopwatch and for taking split and lap times RECALL used to recall recorded split and lap times memories STOP RESET used to stop and reset the stopwatch or timer This is only a brief description of these buttons Detailed uses of the buttons are different in particular functions and will be described later in the instructions Pressing MODE button will toggle among the modes above Note that there is no auto return function in the stopwatch Whenever you change modes the stopwatch will remain in that mode until the MODE button is pressed again 10 11 ACCUSPLIT products use a common setting procedure known as 1 S2 S3 S4 S1 2 sec Enter set function OR S1 4 sec Enter set function amp clear the current settings 2 Select field to be set selected field will flash S3 Set field to desired settings S4 Exit setting function Year Month and date Seconds Minutes MODE Time of Day Mode The starting point for operating your stopwatch is TIME OF DAY If TIME OF DAY is not displayed press Mode until it is Year 2008 Date January 1 Day of week Monday Time 12 00 am The display format is
10. ACCUSPLIT STOPWATCH COMPANY of the WORLD ACCUSPLIT Inc 6120 Stoneridge Mall Rd Suite 210 Pleasanton CA 94588 USA 800 965 2008 925 226 0888 FAX 925 463 0147 www ACCUSPLIT com support ACCUSPLIT com 980 314 IMPORTANT NOTE This stopwatch can store up to 500 split lap times However please note when there are 5 free mem ories left the icon FULL will blink to remind you of the nearly full situation Whenever the storage is full extra split lap times will NOT be stored into memory even though you reset your stopwatch and start a new event Extra split lap times will only be shown on the display but not recorded In order for the stopwatch to record the lap split times again you must delete the data in the DATA memory Please refer to the Data Mode section in the instruction manual for how to delete the memory ACCUSPLIT ACCUSPLIT EXCLUSIVE AX602M500 AX602M500DEC DIGITAL QUARTZ STOPWATCHES OPERATING INSTRUCTIONS INSTRUCTIONS Introduction You are about to enjoy an advanced Cumula tive and Lap memory professional digital quartz stopwatch with advanced timing features Models AX602M500 amp AX602M500DEC Stopwatches include Time of day Daily Alarm Chronograph stopwatch 500 memory Data register Count down timer Stroke Measurement timer and Pacer from 5 to 240 beats per minute Model AX602M500DEC Decimal Stopwatch includes Decimal timing 1 100 of a sec 1 1000 of a min
11. d for displaying the daily alarm time and allows you to enable or disable the alarm When you enter the Alarm Time mode the display shows the alarm time on the upper line while the date is shown in the middle of the display and the normal time is on the lower line J 7 70 Alarm A Ri uu Indicator an gt a AlarmTime day month date 1 in Sii Ht 1 0 nn hr min second Press START SPLIT conse COntT cutively to advance the contrast up to 16 then cycle back to 1 The contrast setting will be shown on the display NOTE The hour digits may be displayed in 12 hr or 24 hr format The year digits can be set from 2000 to 2099 The date adjusts automatically for odd and even months including February of leap years The day of week also adjusts automatically after you set the date To toggle the alarm ON or OFF press STOP RESET When alarm is ON the indicator e will be ON while it will be turned off when alarm is disabled When alarm time is reached the alarm signal will sound for 60 seconds Press any button to stop the alarm sound Setting Alarm Time Press and hold RECALL S1 for 2 seconds to ac tivate the alarm setting The alarm minute digits will flash as an indication Adjust the flashing digit by pressing START SPLIT S3 To set the alarm hour digits press STOP RESET S2 to switch to hour digits and then press START SPLIT S3 to
12. from 0 to 19 rin m AN Press STOP RESET S2 again to adjust the operating mode Press START to switch the operating modes among CR CS and CU At the end of setting press RECALL S4 or MODE to leave setting mode setting and start the pace count The display will show the elapsed time on the upper line the pace count number on the middle and the pace count value on the lower display Guo ai Bs Elapsed time Press STOP RESET to stop the pace count the display will freeze To restart the T7 pace count press START SPLIT oo 5 185 again Or press STOP RESET r nnan to reset the time elapsed and the pace count number p HH 44 45 Stroke Stride Measurement Press MODE until you enter the Stroke Measure ment mode The display will be as follows STROKE 0 0 In the Stroke or Strides Measurement mode the duration of 3 strokes is taken and the stroke frequency counts per minute is calculated If the stroke frequency falls out of the range of 10 180 Err will appear to show the error condition Press START SPLIT to start the measurement During the 1st second 180 0 will be shown and flashing as below 44 46 47 Speed Mode AX602M500 Model only Press MODE until you enter the Speed mode The display will be as follows Distance indicator only used in speed mode nnn i monn Distance mr ro rin wau Lut uu 4 Lap time Had HE Total
13. gain 1 1000M 22 Decimal Timing AX602M500DEC model only 1 The DEC Model can operate as a normal 1 100 second chronograph as well as decimal minute decimal second and decimal hour chronograph As you press MODE to enter the chronograph mode the normal 1 100 second chronograph display will be shown Time base indicator Go to the 1 10 000 hour chronograph by pressing STOP RESET again 1 10 000H Time base indicator 24 25 Please note that if the stopwatch is running no selection for chronograph operating modes can be made until the stopwatch has been stopped and reset Segmented run memory for lap split time storage A header consisting of the date time stamp is attached to each segment to indicate the moment when you began recording the particular timing segment To get to this feature press MODE in chronograph mode to enter DATA mode when the stopwatch has been stopped Records for dif ferent segments can be recalled read or deleted Detailed operation in DATA mode is described in Data Mode section later in this manual 26 27 During data recall the fastest lap time will be reviewed first TOPIE TE Fastest Lap Time indicator Recall indicator ran memory po por g N 000 0 160 LLI tou nny p UUJ G View the slowest lap time by pressing RECALL again Slowest Lap Time indicator af orota PHH 6000753 ri 003
14. orage is not under segmented run memory mode The Recall function is similar to chronograph recall If segmented run memory is selected the DATA mode can be accessed and records storing 52 54 55 Further presses of RECALL will retrieve the memories in ascending order or reverse order depending on whether the speed measurement is stopped or under operation respectively During Recall the Recall indicator is ON Note Speed mode and Chrono mode will not run simultaneously When Chrono mode is active Speed mode should be in reset state and vice versa both the speed and elapsed time can be retrieved Lap Time amp Speed Recall Similar to the Chrono Recall mode during speed measurement or Stop state you can press RECALL to recall the speed lap memories The Mode message will be shown for one to two seconds as the Mode message display is displayed The Speed and Lap time will be displayed on the upper and the middle lines The lower line shows the current time counting During Data recall the fastest speed will be reviewed first then the slow est speed and average speed 53 Please register your new stopwatch at www ACCUSPLIT com support or send this form to address on the back cover of this instruction booklet Email preferred NO PROOF OF PURCHASE LIMITED WARRANTY See label on back of unit for details or check http support ACCUSPLIT com
15. time Note that the default setting is KM Hence KM icon will be ON The upper line shows the distance or speed The lap time is in the middle line while the total time is displayed on the lower line 46 STROKE 180 0 At the end of the first second the display will become steady If measurement is stopped in the first second stroke frequency gt 180 error signal Err will be shown After the first second has elapsed the instantaneous measurement reading will be shown When you press STOP RESET the display will show the steady stroke measurement reading If the measurement lasts for more than 18 seconds stroke frequency lt 10 an error signal Err will be displayed When the measurement is stopped press STOP RESET to reset the displayed reading to 0 0 In Speed mode you can record a number of lap times and speeds for covering the distance you program into the chronograph Before starting to use the Speed mode you need to enter the dis tance as explained below Otherwise the speed measurement won t work Nothing will happen when you press START SPLIT Distance Setting Press RECALL S1 for 2 seconds to enter setting mode The unit icon flashes Distance units nnn m ie 600 i Huu L 48 49 Press START SPLIT S3 to toggle between KM and MILE To select the following digits press STOP RESET S2 The far right digit will blink and you can set the
16. ute 1 100 000 of an hour Model AX602M500 Speed Stopwatch includes Speed Measurement General Features e ACCUSPLIT X case with ergonomic design and no fail buttons 4 button operation Large LCD display with contrast adjustment 12 24 hour display Time of day and chime Daily alarm Full 1 100 second chronograph with working range from 0 to 19 hr 59 min 59 99 seconds with 500 memory records of split and lap time Recall function for recorded split and lap times Count Down timer with working range from 0 to 19 hr 59 min 59 9 seconds Press MODE to cycle through 3 Speed mode Normal Time mode AX602M500 only TIME t Alarm mode Stroke Measurement ALARMI STROKE t Pacer mode 8 Chronograph mode CHRONO PACER Timer mode TIMER RECALL LapTime Recall mode Data mode RECALL DATA Three operating modes Countdown Repeat Countdown Stop Countdown then count up for countdown timer Stroke Stride measurement basing on 3 Speed measurement AX602M500 Model only Decimal second minute and hour chronograph AX602M500DEC Model only Beep sound selectable Uses long life Lithium CR2032 battery for years of use between battery changes e Low battery check The operation of the stopwatch is divided into nine modes As you choose each mode a message will be displayed for a second before you enter the mode RECALL Button t START N ra and 3 SS SPLIT E SM O Be Axeo2msoo
17. you can press any key to exit from delete ready state before the end of the ready period The watch will go back to displaying the segment front page 34 As you continue to press RECALL during the dis play of the last lap you can advance to the next segment by pressing START SPLIT The front page of the segment will be shown Say the next segment is SEG 1 How to delete individual memory segments Search the desired segment first as described above During the display of the segment front page press and hold STOP RESET for 2 sec 33 How to delete all memory segments Instead of deleting one segment you can also delete all memory segments When you enter the Data mode you see the screen FREE XXX LAP Press and hold the STOP RESET for 3 seconds You will hear Beep beep beep for 3 seconds then a long Beep At this point all data in the memory will be deleted and DELETE ALL will show on the display If you don t want to delete the records you can press any key to exit DELETE ALL state before the end of the ready period to return to the seg ment front page display dELETE ALL 36 37 Note You cannot delete all segments while the stopwatch is running If nothing happens when you push and hold STOP RESET check to make sure the stopwatch is stopped 38 39 Number of cycles fii Ai Fit nn Timer setting Time in Countdown gt Fe WEA nn

Download Pdf Manuals

image

Related Search

Related Contents

つなぎかたガイド 第1版 (754KB)  Cirkuit Planet CKP KB6013  Betriebsanleitung  Runco VX VIDEO XTREME VX-33D Specifications  Numark Industries CDN 33 User's Manual  Tascam FW1082 User's Manual  R1P32中継ユニット取説  ASUS (ME176CX) User's Manual  Graphite 58G716 power drill  User Instructions - Flowserve Corporation  

Copyright © All rights reserved.
Failed to retrieve file