Home

Accusplit 625M8D User's Manual

image

Contents

1. e Press B to decrease the digits Press A to start pacer Press A again to the stop Press B to reset to zero Press E to turn the pacer s beep ON or OFF and the symbol will appear or disappear Upper display shows count up timer Ao Pw N 16 PRESET COUNTDOWN TIMER Press C to move the cursor to point to 1 60 tien the rotary switch to the desired minutes 1 60 Press A to start countdown timing Press A again to stop countdown timing Alarm Sounds Press B to return to the original setting OaRWNS To Show Count Up Timing 1 When the time is not up a Press E to check elapsed time b Press E again to return to countdown v 2 When the time is over a Press E to check the time from start flashes b Press E again to show overtime v flashes ACCUSPLIT ALLIANCE 625M8sD MULTIMODE TIMER STOPWATCH FUNCTIONS AND FEATURES DUAL TIMERS 1 second to 100 hours PRESET INTERVAL COUNTDOWNTIMER m special timer modes SU is Two Simultaneous Timers with one lin seconds Selectable preset timer intervals 1 2 3 5 10 12 15 20 25 30 35 40 45 50 55 and 60 minutes Selectable display of Count UP or Count DOWN 30 second warning beep 3 second start of 1 second warnings button Start Stop ID is Two IndependentTimers with own Start Stop button UP isTwo IndependentTimers counting UP with own Start Stop button e Single interval timing e Two button Reset to return to
2. 5 463 0147 www ACCUSPLIT com support ACCUSPLIT com 960 012A
3. ACCUSPLIT ALLIANCE 625M8sD MULTIMODE TIMER STOPWATCH OPERATING INSTRUCTIONS RECALL UP DOWN EE N START STOP an Te fa 05 15 37 34 44 09 6 X X K 60 SET MODE AUTO DUAL 25 35 ALLIANCE 625 MEMORY 8DUAL ROTARY SWITCH INTRODUCTION This unit has five modes Stopwatch Auto Repeat Countdown Timer Dual Display Countdown Timer Pacer and Preset Countdown Timer Press C MODE to change between modes Note Timing must be stopped and reset to zero to change modes MEMORY STOPWATCH SPLIT TIMING 1 2 3 gi p Press C to move the cursor to point to amp Press A to start stopwatch Press B repeatedly to remember the last 8 splits e Lower display shows cumulative split and upper display shows lap split e After 5 seconds the unit will unlock splits to display current running split time Press E to recall the last 8 splits Press A to stop counting Press B to reset to zero START STOP TIMING PI PWNs Press C to move the cursor to point to amp Press A to start counting Press A repeatedly to remember the last 8 time cuts Press E to recall the last 8 times outs Press A to stop counting Press B to reset to zero AUTO REPEAT COUNTDOWN TIMER 1 2 Press C to move the cursor to point to X AUTO Press D to enter set mode e Press B to set hours E to set minutes A to set seconds e Press A amp B at the same time to reset digits to zero Press A to start countd
4. own timing Press E to show the time from start Press E again to return to countdown timing v Press A again to stop counting Press B to return to the original setting When time is up the unit will beep once then start counting again The number of cycles completed is recorded in brackets in upper left of display WN HTARwW DUAL DISPLAY COUNTDOWN TIMER 1 Press C to move the cursor to point to X DUAL 2 Press E to change the dual display timer mode SU or Id or UP 3 Press D to adjust the timer on the lower display Press D again to adjust the timer on the upper display e Press B to set hours E to set minutes A to set seconds e Press A amp B at the same time to reset digits to zero e Press D again to complete the settings 4 SU Two countdown timers work simultaneously e Press A to start e Press A to stop STOP flashes e Press B to reset to the original settings Id Two countdown timers work independently e Press A to start stop lower display e Press B to start stop upper display e Press A amp B at the same time to reset to the original settings UP Two count up timers work independently e Press A to start stop lower display STOP flashes when stopped e Press B to start stop upper display STOP flashes when stopped e Press A amp B at the same time to reset to zero PACER WITH COUNT UP TIMER 1 Press C to move the cursor to point to X PACE 2 Press D to adjust the frequency e Press A to increase the digits
5. pre set interval and Two button Reset to zero during setting Alarm at zero for 5 seconds of interval Then selectable display of total elapsed time or overtime PACER RATE TIMER USER SELECTABLE AUTO REPEAT TIMER 1 second to 100 hours Repeat timer Alarm at zero for each repeat 3 second warnings if interval over 5 minutes Selectable display of time remaining in an interval or cumulative elapsed time Repeat timer counter to 99 8 DUAL MEMORY STOPWATCH 1 100 second to 10 hours Saves in memory the last 8 Dual Split Lap and Cum Splits Split Counter up to 99 Memory Review during timing 5 second Automatic Split release and return to running display beats per minute Timer up to 100 hours by second e Signal Pace Counter up to 10 000 e Selectable Pace Rate frequency from 10 to 240 by 10 e Selectable ON or OFF Pace Rate beep BATTERY see back of timer e CR 2032 3V lithium battery Panasonic or equivalent e Not water resistant l REGISTER NOW Please return Email preferred your AL625M8D Registration to the Repair Center address in the warranty and we will let you know about future products User NO PROOF OF PURCHASE LIMITED WARRANTY See label on back of unit for details or check http support ACCUSPLIT com Eat Right Walk More Live Wet The ACCUSPLIT Lifestyle ACCUSPLIT Inc e 2290M Ringwood Ave San Jose CA 95131 800 965 2008 e 925 226 0888 e FAX 92

Download Pdf Manuals

image

Related Search

Related Contents

ダウンロード  Service Manual  1 - ViewSonic  Mode d`emploi - Britax Römer  Guida per l`utente della stampante/copiatrice Xerox WorkCentre  Viktor - Stadler Form  Manual de Instalação  

Copyright © All rights reserved.
Failed to retrieve file