Home
A&D UT-302PBT User's Manual
Contents
1. ie 2 Product Identification LED Wireless connecting indicator O Wireless Reset Key Es Wireless Power Button MEMORY Recall Button Power amp Measure Button LCD Display LJ Battery compartment lid Description of LCD Display Degrees of Temperature Memory Symbol Celsius and Sets of BG 700 O IC Scale ecords i ODF cabrones pam Cm Scan in Smiling face t Progress Indicating temperature Low battery is lower than Warning 38 C 100 4 F Frowning face Indicating temperature is equal or higher than 38 C 100 4 F Battery Installation Low battery warning When the battery power becomes low the it low battery symbol will appear on the display The thermometer can still be used during this time but the batteries should be replaced as soon as possible If the batteries run out completely Lo will be displayed along with the low battery symbol In this case the batteries will need to be replaced before using the thermometer again Replacing the Battery 1 Use a Phillips head screwdriver to loosen battery cover screw Remove the battery cover 2 Insert or replace 2 x 1 5 V AAA alkaline batteries into the battery compartment ensuring to match the indicated polarity symbols Always use new batteries e 3 Place the battery cover on the thermometer and tighten the Screw to secure it in place ins
2. 4 26 Blacklands Way Abingdon Business Park Abingdon OX14 1DY United Kingdom Oxfordshire Telephone A amp D ENGINEERING INC 44 1235 550420 44 1235 550485 1756 Automation Parkway San Jose California 95131 USA Telephone A amp D AUSTRALASIA PTY LT 32 Dew Street Thebarton South Austr Telephone 1 408 263 5333 61 8 352 3033 1 408 263 0119 D alia 5031 AUSTRALIA 61 8 352 7409 2014 A amp D Medical All rights reserved
3. A amp D Medical MODEL UT 302PBT on Be m p p m oa RON 8 Index Introduction Important Information Before Use Product Identification Description of LCD Display Battery Installation Changing Modes C F Switchable Tips for Measuring Human Temperature Measuring Body Temperature in the Ear Memory Function Operating The Bluetooth Function Care and Maintenance Applied Standards Error Codes Technical Specifications FCC Statement EMC Tables O oO A CQ OW N mE ek Ge lt ae ae a a o o a a A A Oo Introduction Utilizing infrared technology this thermometer takes temperatures in seconds by measuring heat generated by the ear canal or other objects This product conforms to the provisions of the EC directive MDD 93 42 EEC Its advantages include 1 Wireless communication Bluetooth class 2 2 Intended use For home clinic and hospital use to determine human body temperature Illuminated back light display 10 user memory C F switchable function Probe cover free Waterproof probe design One second reading Auto power off for power saving Low battery indicator Warning indication for battery condition and measuring range Large LCD display O O Q W a _ N Important Information Before Use When using this product please be sure to follow all the notes listed below Any action against these no
4. applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the UT 302PBT Thermometer is used exceeds the applicable RF compliance level above the UT 302PBT Thermometer should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as reorienting or relocating the UT 302PBT Thermometer b Over the frequency range 150 kHz to 80 MHz field strengths should be less than 3 V m 19 EMC Tables Recommended separation distances between portable and mobile RF communications equipment and the UT 302PBT Thermometer The UT 302PBT Thermometer monitor is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the UT 302PBT Thermometer can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communication
5. drum damage or in the healing period after operative procedures In all of these cases please consult your doctor Use of the thermometer on different persons can be inappropriate in the event of certain acute infectious diseases because of the possible spread of germs despite cleaning and disinfection If you have any doubts please consult your doctor This thermometer may only be used without a disposable protective cover If you have been lying on one ear for some time the temperature is slightly raised Wait a little while or measure in the other ear As ear wax can affect the measurement you should clean the ear before measuring if necessary 6 Measuring Body Temperature in the Ear 1 Remove the front cover Remove the cover cap Remove the cap by gently pushing it up 1 and then pulling it off forwards 2 2 Press the Power button to switch the thermometer on Following a successful self test the device emits two short beeps 3 Make sure that the sensor tip and also the ear canal are clean As the ear canal is slightly curved you have to pull the ear slightly up and backwards before inserting the sensor tip This is important so that the sensor tip can be pointed directly at the eardrum Insert the probe into the ear canal the probe must insert well to ensure an accurate temperature measurement then press the Power amp Measure button for about 1 second release the button and y
6. he interference by one of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on a circuit different from that to which the receiver is connected 4 Consult the dealer or an experienced audio TV technician for help 5 FCC Caution To assure continued compliance example use only shielded interface cables when connecting to computer or peripheral devices Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment 16 FCC Statement 6 This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation 7 This device complies with FCC radiation exposure limits set forth for an uncontrolled environment End users must follow the specific operating instructions for satisfying RF exposure compliance This transmitter must not be co located or operating in conjunction with any other antenna or transmitter EMC Tables Guidance and manufacturer s declaration electromagnetic emission The UT 302PBT Thermometer is intended for use in the electromagnetic environment specified below The cus
7. m Power frequency magnetic fields should be at 50 60 Hz levels characteristic of a typical location in a magnetic field IEC typical 61000 4 18 EMC Tables Guidance and manufacturer s declaration electromagnetic immunity The UT 302PBT Thermometer is intended for use in the electromagnetic environment specified below The customer or the user of the UT 302PBT Thermometer should assure that itis used in such an environment Immunity IEC 60601 test Compliance Electromagnetic environment guidance test level level Radiated 3 V m 3 V m Portable and mobile RF communications equipment RF IEC 80 MHz to 2 5 should be used no closer to any part of the UT 302PBT 61000 4 3 GHz Thermometer including cables than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Recommended separation distance 2VP 2 4 P 80 MHz to 800 MHZ 3 P 800 MHz to 2 5 Ghz where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer and d is the recommended separation distance in metres m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol NOTE 1 At 80 MHz and 800 MHz the higher frequency range
8. ou will hear 1 short beep sound means complete the measurement Measuring Body Temperature in the Ear Under 1 year S Have child lay flat with the head 7S sideways so that the ear is facing ZEN upwards Gently pull the ear straight back Wee Rasy p wai 5 You may take out the device to read the measurement result 6 The backlight display will remain light for approximately 5 seconds each time the Power amp Measure button is pressed after each reading is completed and each time the Memory button is pressed to recall a previous reading 7 The thermometer will automatically shut off after one minute without use 368 838882 368 i 1year Stand behind and slightly to the side of the child adult Gently pull the ear up and back to straighten the ear canal Qm instruction 1 To ensure accuracy please wait at least 20 seconds between successive readings 2 Clean the thermometer lens again after use Wait at least 10 minutes between consecutive readings to ensure accuracy 8 Measuring Body Temperature in the Ear The Readings If the temperature measurement is below 38 C a Smiling Face will be appear next to the reading If the reading is 38 C or above a Frowning Face will be displayed Memory Function Memory Recall You can recall up to 10 measurements of all currently sto
9. red measurements in memory to share with your physician or trained healthcare professional 1 While in power on mode press once briefly on the Memory button then pass it again to show the last measurement accompanied by GO symbol 2 Continue to press the Memory button to view the next previously stored measurement so 3 1 then all the way to og s 3 Automatically on the 11th measurement when the 10 memories have been used up any new measurement will be recorded and the oldest memory deleted 10 Operating The Bluetooth Function 1 Turn the ear thermometerto the back side 2 Turn on the wireless power From off to on while the thermometer searches for other Bluetooth compatible devices the LED connection indicator will flash When the device connects successfully to health monitoring devices and Bluetooth capable devices such as a computer PDA or mobile phone the LED will remain lit At conclusion of temperature measurement the reading will be sent to the health monitoring device and the reading will automatically stored in memory 3 To disconnect from health monitoring devices turn off the wireless power From on to off and the LED will no longer be lit Operating The Bluetooth Function What You Need The host computer or terminal system to run Serial Port Profile SPP A personal computer with Operating system Windows 95 or later A Smar
10. s equipment transmitters and the UT 302PBT Thermometer as recommended below according to the maximum output power of the communications equipment Rated maximum Separation distance according to frequency of transmitter output power of m keer a 150kHzl080MHZ 80MHzto800MHZ 800 MHzto2 5 GHz d 1 2V P d 12 P d 124 P 0 01 0 12 0 12 0 23 01 0 38 0 38 0 73 1 12 13 23 10 3 8 3 8 73 100 12 12 23 For transmitters rated at a maximum output power not listed above the recommended separation distance d in metres m can be estimated using the equation applicable to the frequency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer NOTE 1 At 80 MHz and 800 MHz the separation distance for the higher frequency range applies NOTE2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people 20 This device includes RF transmitter with wireless communication TUV NO 0197 The device shall be disposed in accordance with national laws after their useful lives Refer to struction Type BF equipment Sensor 21 AND A amp D Company Limited 1 243 Asahi Kitamoto shi Saitama 364 8585 JAPAN Telephone A amp D INSTRUMENTS LTD 81 48 593 1111 81 48 593 1119 Unit 2
11. t Phone with Android system Others PDA etc instruction Please refer to the instruction manual of your personal computer for how to install Serial Port Profile SPP Bluetooth LED FAST BLINKING indicate this UT 302 PBT is at linking state waiting to be linked by other Bluetooth terminal system like Smart Phone SLOW BLINKING indicate UT 302 PBT is waiting for connection from other master Bluetooth device ACTIVE indicate Bluetooth connection have been established successfully 12 Operating The Bluetooth Function Communications Interface Using Bluetooth communications terms the UT 302PBT is a slave device To connect the UT 302PBT to a master device you must initiate the connection by first pairing with the UT 302PBT To complete the pairing process the 0000 number must be provided to the master as the Bluetooth Pass Key Bluetooth PIN Code Once the pairing is complete the UT 302PBT will automatically reconnect to the master device when possible The four digit Bluetooth Pass Key must be entered only during the pairing to a new master instruction To connect to a new device new master the UT 302PBT must be out of range from the previous master or unpaired from that master Care and Maintenance Probe and Tip EX Clean the probe and tip with an lt N S alcohol swab before and after each measurement P XN DJ Thermometer Use a soft dry cloth to clean thermome
12. ter body Never use abrasive cleaning agents thinners or benzene for cleaning Do not scratch the surface of the probe lens or the display Do not expose the thermometer to extreme temperatures humidity direct sunlight or shock Applied Standards This product conforms to the provisions of the EC directive MDD 93 42 EEC The following standards apply to design and or manufacture of the products EN12470 5 Clinical thermometers Part 5 Performance of infrared ear Thermometers with maximum device AST M E 1965 98 Standard Specification for Infrared Thermometers for Intermittent Determination of Patient Temperature IEC EN 60601 1 Medical electrical equipment Part1 General requirements for safety IEC EN 60601 1 2 Medical electrical equipment Part2 Collateral standard Electromagnetic compatibility Requirements and tests 14 Error Codes When a malfunction or incorrect temperature measurement occurs an error message will appear as described below LCD Display Cause Solution Operate the thermometer The temperature measured is only between the lower than 34 C 93 2 F specified temperature ranges If necessary clean the sensor tip In the event of a repeated The temperature measured is error message contact higher than 43 C 109 4 F your retailer or Customer Services Operate the thermometer only between the specified temperature ranges The opera
13. tices may cause injury or affect the accuracy 1 Do not disassemble repair or remodel the thermometer Be sure to clean the thermometer lens each time after usage Avoid direct finger contact with the lens No modification of this equipment is allowed It is recommended that user take 3 temperatures If they are different use the average reading Do not expose the thermometer to extreme temperature very high humidity or direct sunlight Avoid extreme shock or dropping the device Before the measurement patients and thermometer should stay in steady state room condition for at least 30 minutes Avoid measuring temperature in 30 minutes after exercise bathing or returning from outdoor 10 To protect the environment dispose of empty batteries at appropriate collection sites according to national or local regulations 11 Please use the thermometer solely for its intended purpose 12 Carefully hold the device when in use to avoid dropping the device 13 Allow one minute between successive measurements as slight variations may occur if measurements are taken over a short period of time Use average temperatures instead 14 There are no absolute body temperature standards Keep reliable records of your personal temperature to serve as areference for judging a fever 15 Under any circumstances the temperature taking result is ONLY for reference Before taking any medical action please consult your physician
14. ting temperature is not in the range from 16 C 35 C 60 8 F 95 0 F Technical Specifications Measuring range 34 C 43 C 93 2 F 109 4 F Measuring accuracy 35 5 C 42 C 95 9 F 107 6 F 0 outside the range 0 Operating environment de 16 C 35 C 60 8 F 95 F A with relative humidity up to 85 non condensing Storage Transportation environment ssc 25 C 55 C 13 F 131 F with relative humidity up to 85 non condensing Display resolution 0 1 C or F Power supply 2x1 5 VAAA alkaline batteries Weight approx 70g without batteries Dimensions approx 6 2in x 1 7in x 2 1in L x W x H 2 C 0 4 F 3 C 0 5 F 15 FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occurina particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct t
15. tomer or the user of the UT 302PBT Thermometer should assure thatitis used in such an environment Emissions test Compliance Electromagnetic environment guidance RF emissions CISPR 11 Group 1 The UT 302PBT Thermometer uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF emissions Class B CISPR 11 Harmonic Not The UT 302PBT Thermometer is suitable for use in all emissions applicable establishments including domestic establishments and IEC 61000 3 2 those directly connected to the public low voltage power Voltage Not supply network that supplies buildings used for domestic fluctuations applicable Purposes flicker emissions IEC 61000 3 3 Guidance and manufacturer s declaration electromagnetic immunity The UT 302PBT Thermometer is intended for use in the electromagnetic environment specified below The customer or the user of the UT 302PBT Thermometer should assure that itis used in such an environment IEC 60601 Compliance m Immunity test ost level level Electromagnetic environment guidance Electrostatic 6kV t 6 kV Floors should be wood concrete or ceramic discharge ESD contact contact tile If floors are covered with synthetic IEC61000 4 2 t8kVair 8kVair material the relative humidity should be at least 30 Power frequency 3A m 3 A
16. truction Battery operated 1 Please properly dispose of the batteries away from small children and heat 2 Itis recommended to remove the batteries if the unit will not be used for an extended period of time 3 Batteries must be disposed of in accordance with local environmental and institutional policies 4 Changing Modes C F Switchable This thermometer can display result in either degrees Fahrenheit F or degrees Celsius C Changing C F please make sure the device is in power on condition Press the Power Scan button hold it and then press the Memory button to toggle between C and F gt Tips for Measuring Human Temperature Bear in mind that the thermometer needs to have been in the room in which the measurement is taken for at least 30 minutes before use Some people produce different readings in their left and right ear In order to record temperature changes always measure a person s temperature in the same ear The ear thermometer may be used by children only under adult supervision Measurement is usually possible over the age of 6 months In infants under 6 months the ear canal is still very narrow so the temperature of the eardrum often cannot be recorded and the result displayed is often too low The measurement must not be taken in an ear affected by inflammatory diseases e g discharging pus or secretion after possible ear injuries e g ear