A&D HL-300WP User's Manual

image

Contents

1. Installing Batteries Connecting The adapter Installing Batteries CAUTION When replacing batteries be careful not to apply too much force to the weighing pan An excessive force could damage the scale Close the rubber cap t Remove the battery cover and insert six batteries R6P LR6 AA size into the batterv compartment taking extreme care to that the polarities plus and minus are observed Be sure to lock the batterv cover again after installing the batteries Batterv cover lock Optional AC Adapter New six batteries R6P LR6 size adapter optional A CAUTION When using an AC adapter the scale does not comply with the IP65 The AC input requirement could be 100 120 220 230 or 240 volts 50 60Hz depending on the area where used so please verify that the adapter is correct Plug the AC adapter to the AC adapter 22 socket inside the batterv compartment gt lt Attach the batterv cover and fit the L OE O rubber cap AC Adapter jack Setting up the HL WP ANCAUTION Avoid installing the scale in direct sunlight as that mav cause discoloration or a malfunction Place vour HL WP on a firm weighing table so that the scale is level The scale will not perform accurately when it is not level Place the scale on the firm surface and adjust the feet so that the sprit level shows the scale is level for an accurate weighing 3
2. WEIGHING Before weighing Automatic Power Off Function If the scale is left ON and the stable indicator is displaved the automatic power off function turns the power off after approximatelv 5 minutes factorv setting To toggle the function disabled enabled press the ON OFF key while pressing the RE ZERO key The scale stores the setting and it will be shown by pressing both the RE ZERO and UNITS keys in the weighing mode See CALIBRATION about the UNITS key PoFFU Function disabled PoFF I Function enabled Error message E Overload The scale zero is out of range L Low batterv Calibration mav be required before weighing Read CALIBRATION first and if necessary calibrate your scale for accurate weighing Weighing procedures 1 Turn on the scale Press the ON OFF key to turn on the scale Then the scale displays all segments for a few seconds and then 0 will be displayed 2 Start weighing If you do not use a container for weighing Verify the reading is 8 If press the IRE ZEROJ to displav o Place objects on the weighing platform to weigh When the reading becomes stable the stable indicator is displayed If you use a container for weighing Place an empty container on the platform Wait for the stability indicator to be displayed and press the IRE ZEROJ key Place the objects to be weighed in the contai
3. Digital Scale HL WP Series INSTRUCTION MANUAL HL 1000WP HL 300WP HL 3000WP HL 3000LWP 1WMPD4000754B A amp D Company Limited SAFETV PRECAUTIONS All safety messages are identified by the following WARNING CAUTION of ANSI 2535 4 American National Standard Institute Product Safety Signs and Labels The meanings are as follows A WARNING A potentially hazardous situation which if not avoided could result in death or serious injury A CAUTION A potentially hazardous situation which if not avoided may result in minor or moderate injury product A WARNING A CAUTION IP65 Q This manual is subject to change without notice at any time to improve the Product specifications are subject to change without any obligation the part of the manufacture When using the HL WP the following safety precautions should always be followed Use only the specified AC adapter for the scale Other adapters may cause damage The AC adapter is optional Internal service or adjustments to this product should be performed by a qualified person Avoid installing the scale in direct sunlight which may cause discoloration or malfunctions Do not mix the type of batteries Replace all the batteries at the same time If the scale is not to be used for a long period of time remove all batteries from the battery compartment to avoid leakage Avoid overloading that c
4. brate zero CAL 0 will be displayed Wait for the stable indicator to be displayed and press the RE ZERO key LAL F will be displayed in a few seconds If only the zero calibration is to be done press the UNITS key The scale will display End and automatically return to the weighing mode 3 Span calibration Place the weight at the center of the platform for accurate calibration Wait for the stable indicator to be displayed and then press the RE ZERO key The display will show End and the scale will automatically return to the weighing mode Gravitv compensation If you have calibration weights at the capacity of the scale you can calibrate the scale with the weights instead of compensating for acceleration due to gravity The scale was calibrated at 9 798 m sec at the factory If the acceleration due to gravity at your location is not same compensate the scale by adjusting the acceleration due to gravity Refer The Value of Gravity at Various Locations and World Map and find your location value 1 Enter calibration mode Press the ON OFF key to turn the power off While pressing both the RE ZERO key and the UNITS key press the ON OFF key CAL will be displayed 2 Select a digit to be changed Press the UNITS key The previously set value for example 9190 will be displayed A digit after the comma will be chang
5. ed by pressing the RE ZERO key Press the UNITS key to move the comma and select a digit to be changed 3 Set the new value Change the value of the gravity acceleration using the RE ZERO and UNITS keys 4 Save the value in memory Press and hold the UNITS key until is displayed The scale will automatically return to the weighing mode SPECIFICATIONS MODEL HL 1000WP HL 300WP HL 3000WP HL 3000LWP Capacity 1000 x 0 5 g 300 x 0 1g 3000 x 1g X 2 2 x 0 001 Ib So 6 6 x 0 002 Ib Resolution 35 28 x 0 02 oz 10 58 x 0 01 oz 105 8 x 0 1 oz 216 3 3 x 0 1 oz 6 Ib 9 8 x 0 1 oz Non linearity 1g 0 2g 29 Repeatabilitv 0 59 0 14 19 0 015 5 C 35 C 417F 95 F Operating temp 10 C 40 C 14 F 104 F Less than 85 Displa 13 mm 0 51 inches 7segment liquid crystal displa Display update Approximately 10 times per second Power 6 x R6EP LR6 size batteries AC adapter Battery life Approximately 100 hours with manganese type 200 hours with alkaline cells at 20 C 68 F Platform size 128 W x 128 D mm 174 W x137 D mm 5 0 W x 5 0 D in 6 8 W x5 4 D in Dimensions 170 W x 219 D x 63 H mm 174 W x219 D x63 H mm 6 7 x 8 6 D x 2 5 H in 6 8 W x8 6 D x2 5 H in Weight approx 870 1 916 950 g 2 116 Calibration weight 1000g 0 19 300g 0 02g 3000g 0 2
6. g Accessories This manual Options AC adapter The Value of Gravity at Various Locations Amsterdam 9 813 m s Manila 9 784 m s Athens 9 807 m s Melbourne 9 800 m s Auckland NZ 9 799 m s Mexico City 9 779 m s Bangkok 9 783 m s Milan 9 806 m s Birmingham 9 813 m s New York 9 802 m s Brussels 9 811 m s Oslo 9 819 m s Buenos Aires 9 797 m s Ottawa 9 806 m s Calcutta 9 788 m s Paris 9 809 m s Cape Town 9 796 m s Rio de Janeiro 9 788 m s Chicago 9 803 m s Rome 9 803 m s Copenhagen 9 815 m s San Francisco 9 800 m s Cyprus 9 797 m s Singapore 9 781 m s Djakarta 9 781 m s Stockholm 9 818 m s Frankfurt 9 810 m s Sydney 9 797 m s Glasgow 9 816 m s Taichung 9 789 m s Havana 9 788 m s Taiwan 9 788 m s Helsinki 9 819 m s Taipei 9 790 m s Kuwait 9 793 m s Tokyo 9 798 m s Lisbon 9 801 m s Vancouver BC 9 809 m s London Greenwich 9 812 m s Washington DC 9 801 m s Los Angeles 9 796 m s Wellington NZ 9 803 m s Madrid 9 800 m s Zurich 9 807 m s HHHH ACCELERATION DUE TO GRAVITY N L World Map
7. ner Select the weighing unit Only for U S A models If you use the U S A model press the UNITS key to select weighing unit Normally scales power up in Ib or oz when shipped from the factory To power up in other units turn the scale off Press and hold the UNITS key then press the ON OFF key The scale will start with the next unit Note HL 300WP oz gt g gt 0z gt HL 1000WP 3000WP 3000LWP lb gt oz gt lb 0oz gt g7lb gt 4 CALIBRATION When to calibrate Calibration may be required when the scale initially installed if it is moved a substantial distance or in accordance with local regulations This is necessary because the weight of a mass in one location is not necessarily the same in another location Also with time and use mechanical deviations can occur The position of the UNITS key for the Calibration The 9 model has no UNITS key but the key Location of the UNITS key used to enter calibration is located under the overlay Calibration using a calibration weight Calibrate the scale with calibration weights at full capacity HL 1000WP 10009 0 19 HL 300WP 300g 0 029 HL 3000WP 30009 0 29 HL 3000LWP 30009 0 29 1 Enter calibration mode Press the ON OFF key to turn the power While pressing both the RE ZERO key and the UNITS key press the ON OFF key CAL will be displayed 2 Zero calibration Press the RE ZERO key to cali
8. ould cause damage to the scale Avoid using the weighing pan to move the scale as that could cause damage to the scale When the scale is used with an AC adapter the scale does not conform to IP 65 protection f Degree of protection against water Protected against water jets Degree of protection against solid foreign objects Dust tight _____ Code Degree of protection provided by enclosures of IEC 60529 PARTS DESCRIPTION ON OFF kev Turns the scale power on off RE ZERO kev Sets displav to zero or subtracts weight of container UNITS kev U S A models Changes weighing units Batterv cover Platform Displav Four leveling feet Rubber cap Batteries are not included t 1 is stable STABLE indicator Indicates when the reading NET indicator is used Indicates when NET weight is displaved Tare function Zero is correct ZERO indicator Indicates when the scale Polaritv AC adapter jack A tS 2 Batterv cover lock Batterv compartment Weighing unit g Weighing unit Ib Weighing unit oz gt U S A models only Weighing unit 16 07