1. 5 XW 1 2 H 94 Operating Temperature 10 to 120 F Humidity 90 relative humidity non con densing Battery 2 AAA Alkaline batteries Transmitter Frequency 319 5 MHz Transmitter Range 500 feet open air Compatibility not UL investigated FCC Notice This device complies with FCC Rules Part 15 operation is subject to the following two condi tions 1 This may not cause harmful interference 2 This device must accept any interference that may be received including interference that may cause undesired operation Changes or modifications not expressly approved by Interactive Technologies Inc can void the user s authority to operate the equipment Specifications EL FCC Notice CS eee interlogig Security amp LiFe SAFETY GRouP ITI 2266 SECOND STREET NORTH NorTH SAINT PauL MN 800 777 2624 www interlogixinc com Cavpx ESL GBC i SENTROL 2001 Interlogix Inc Interlogix Concord and Concord Express are trademarks of Interlogix Inc ITI and SuperBus are registered trademarks of Interlogix Inc
2. adjacent but less visi ble place Materials and Tools Needed 0 Hermetically sealed external switches sealed reed switch that supply a minimum 250 milli second open or closure on alarm only normally closed circuits can be used on the Simon panel QO Stranded 22 gauge wire U Small wire cutters C Sensor and magnet spacers optional Installation Guidelines 1 Install the magnet on the opening edge of the door or movable part of a window 2 Position the switch on the door or window frame within one inch of the magnet 3 Remove the cover from the Door Window Sensor Pass the wires on the external switch through the rear opening at the bottom of the Door Window Sensor 5 Attach each wire to one side of the screw terminal 31 255 Press the screw terminal over the wire posts 6 Mount the sensor Programming Follow these instructions to program the touchpad 1 Open the control panel cover 2 Enter Utility Access Code 1 or 2 using the red num bered buttons 3 Press Add from the Start Menu Press the Sensor Remote button from the Main menu until you hear the location you wish to use with the sen Sor The order of names the Control Panel uses are key chain remote touchpad remote front door back door garage door bedroom guest room child s room utility room living room dining room bathroom laundry room kitchen office den garage special chime base ment upstairs downstairs hal
3. ITI Part No 60 670 95R ITI SAW Door Window Sensor Document Number 466 1559 Rev B March 2002 Product Summary Door Window Sensors can be installed on doors windows or many other objects that open and close The sensors transmit signals to the Control Panel when a magnet mounted near the sensor is moved away from or closer to the sensor Installation Guidelines Use the following guidelines for installing Door Window sensors U Mount the sensor on the door frame and the magnet on the door If the sensor is to be used on double doors mount the sensor on the least used door and the magnet on the other door Q If possible locate sensors within 100 feet of the panel While a transmitter may have a range of 500 feet or more out in the open the environment at the installa tion site can have a significant effect on transmitter range Sometimes a change in sensor location can help overcome adverse wireless conditions U Make sure the alignment arrow on the magnet points to the alignment mark on the sensor Q Place sensors at least 5 inches above the floor to avoid damaging them Q Avoid mounting sensors in areas where they will be exposed to moisture or where the operating tempera ture 10 120 F will be exceeded U Use spacers not included to keep sensors and magnets away from metal or metallic surfaces such as foil wall paper Materials Needed L 6 flathead screws Q Screwdriver or brad driver The fo
4. it only tests sensor operation for the cur rent conditions You should perform a sensor test after any change in environment equipment or program ming If a Sensor Fails the Sensor Test If sirens do not beep when a sensor is tripped use an ITI RF Sniffer 60 401 test tool to verify that the sensor is trans mitting Constant beeps from the RF Sniffer indicate a run away faulty sensor Replace the sensor To improve sensor communication you can reposition the sensor 0 relocate the sensor U if necessary replace the sensor To reposition a sensor 1 Rotate the sensor and test for improved sensor commu nication at 90 and 180 degrees from the original posi tion 2 If poor communication persists relocate the sensor as described as follows To relocate a sensor 1 Test the sensor a few inches from the original position 2 Increase the distance from the original position and retest until an acceptable location is found 3 Mount the sensor in the new location 4 Ifno location is acceptable replace the sensor To replace a sensor 1 Test a known good sensor at the same location 2 If the transmission beeps remain below the minimum level avoid mounting a sensor at that location 3 Ifthe replacement sensor functions contact ITI for repair or replacement of the problem sensor Specifications Compatibility Simon Basic Simon II Simon 3 Concord Express QuikBridge Case dimensions L 4
5. llowing illustrations and procedure describe how to install the Door Window sensor Installation Instructions Sensor Align Arrow and Mark Door Frame 2 AAA Batteries Figure 1 Sensor and Magnet Positions and Alignment To install Door Window sensors 1 Remove the sensor cover by pressing the button on the narrow end Remove the batteries to access the mounting holes 3 Mount the sensor base with two 6 flathead screws at the locations shown in Figure 2 If you need to connect external switches they should be installed at this point Use the procedure for connecting external switches Mounting Holes cS a Figure 2 Mounting Hole Locations Bottom View 4 Remove the magnet from its base Line up the arrow on the magnet with the mark on the sensor 5 Mount the magnet base no more than 3 8 inch away from the sensor base Replace the magnet cover 6 Re install the batteries and circuit board and attach the sensor cover to the sensor base Note When window or door construction does not allow the Programming De transmitter to be installed next to the magnet use an external switch to install the Door Window Sensor Connecting External Switches External switches used with Door Window Sensors allow you to protect doors and windows when there is inadequate room for directly mounting the sensor or when you want to locate the Door Window Sensor in an
6. lway medicine cabinet closet attic Each name may be used more than once Note When adding sensors if you wish to use a more descriptive location you may press the option button to use the compass directions north north east east south east south south west west north west 5 Press DONE 6 Enter the sensor type number 10 for exterior door 14 for interior door and 13 for window with the red num bered keys Note If you wish to use a sensor number other than the next available enter a 2 digit sensor number with the red numbered keys immediately after entering the sensor type 7 Press the button on the top of the sensor cover removed Testing Door Window Sensors used with the Simon Control Panel The following steps describe the guidelines for testing sen sors 1 Open the Control Panel cover 2 Enter the Utility Access Code 1 or 2 using the red num bered buttons 3 Press the Test button once Press DONE 5 Trip the sensor move the magnet away from the sen sor and do not replace the magnet until the Control Panel indicates the number of RF packets received 6 Note the number of siren beeps indicating how many RF packets the Control Panel received from the sensor You should hear 7 8 beeps We recommend that you test the sensors after all program ming is completed and whenever a sensor related problem occurs Note While the sensor test is a valuable installation and service tool
Download Pdf Manuals
Related Search
Related Contents
Midi2Org_16 - Orgautomatech T04TCAr07 Phonix LGL52FPG mobile phone case D-Link (DES-3550) (DHDES3550) MODULES SOLAIRES ISSOL – Garanties limitées 取扱説明書 - シャープ Samsung MW872-S מדריך למשתמש USER MANUAL - Zep Equipment EVM-7 Series Environmental Monitor Quick Start Guide Copyright © All rights reserved.