1. m Includes a 1 GB Transportable Memory Module TMM cache and chassis mount remote supercap power module for data cache backup m RAID levels supported RAID 0 1 5 6 10 50 60 see the RAID Configuration Options section later in this table RAID Configuration Options not available for embedded RAID R2XX RAIDO Factory preconfigured RAID striping option Enable RAID 0 Setting Requires a minimum of one hard drive R2XX RAID1 Factory preconfigured RAID mirroring option Enable RAID 1 Setting Requires exactly two drives with the same size speed capacity R2XX RAID5 Factory preconfigured RAID option Enable RAID 5 Setting Requires a minimum of three drives of the same size speed capacity R2XX RAID6 Factory preconfigured RAID option Enable RAID 6 Setting Requires a minimum of four drives of the same size speed capacity R2XX RAID10 Factory preconfigured RAID option Enable RAID 10 Setting Requires an even number of drives minimum of four drives of the same size speed capacity CO NOTE Although RAID levels 50 and 60 are not orderable from the factory they are N supported for selected controllers as shown in Table 6 Cisco UCS C22 M3 High Density SFF Rack Mount Server 19 CONFIGURING the SERVER 20 Approved Configurations 1 1 CPU Configurations Select an embedded RAID option from Table 5 on page 18 or one PCle RAID controller from Table 6 on page 18 You may also select an appropriate optional
2. CAB 9K10A EU SFS 250V 10A ID SFS 250V 10A IS PID Description Power Cord SFS 250V 10A Argentina Power Cord 250VAC 10A 3112 Plug Australia Power Cord SFS 250V 10A China AC Power Cord 250V 10A PRC Power Cord 250VAC 10A CEE 7 7 Plug EU Power Cord SFS 250V 10A India Power Cord SFS 250V 10A Israel Cisco UCS C22 M3 High Density SFF Rack Mount Server Images i 2500 mm 7 A HE Cordset rating 10 A 250 500 V MAX Plug EL 219 IRAM 2073 Length 8 2 ft Connector EL 701 IEC60320 C13 5 oy Plug EL 210 7E jk iO TN Cordset rating 10 A 250 V 500 V MAX 7 Y Length 2500mm Connector EL 701C EN 60320 C15 o BS 1363A 13 AMP fuse Plug EL 218 CCEE GB2009 i Cordset rating 10A 250V Connector EL 701 o IEC60320 C13 3 UNTU IOONI Cordset rating 10A 16 A 250 V Length 8 ft 2 in 2 5 m Plug EL 208 if S Cordset rating 16A 250V m ra 2500mm IEC60320 C13 31 CONFIGURING
3. 4 or 8 DIMMs total The DIMMs will be placed by the factory as shown in the following table Number of DIMM Placement DIMMs per Channels A and D are not used with memory mirroring CPU 2 CPU 1 CPU 2 1 DIMM in Channel B 1 DIMM in Channel E 1 DIMM in Channel C 1 DIMM in channel F 4 CPU 1 CPU 2 2 DIMMs in Channel B 2 DIMMs in Channel E 2 DIMMs in Channel C 2 DIMMs in Channel F m Select the memory mirroring option NO1 MMIRROR as shown in Table 4 on page 14 NOTE System performance is optimized when the DIMM type and quantity are equal rd for both CPUS Cisco UCS C22 M3 High Density SFF Rack Mount Server 15 CONFIGURING the SERVER 16 Caveats Do not mix 1333 MHz and 1600 MHz DIMMs Do not mix DIMM types RDIMM LRDIMM or UDIMM Do not select more than two different types of DIMMs only two PID types allowed For 2 CPU configurations install a minimum of 2 DIMMs one per CPU If you use different sizes of DIMMs the quantity of each size of DIMM must be even 2 4 or 6 For example 4 UCS MR 1X082RY A DIMMs and 6 UCS MR 1X162RY A DIMMs Also the sum of all PIDs must adhere to the maximum quantity rule of 12 DIMMs for 2 CPU systems By default all DIMMs run at 1 35 V which yields 1333 MHz memory speeds To run the memory DIMMS at 1600 MHz you need to go into the BIOS or set the policy with UCSM service profile to run in Performance Mode This forces the DIMMs to operate at 1 5 V and yields 1600 M
4. 1102 mm 89 x 33 x 47 in 2261 x 838 x 1194 mm 29 2 in 741 mm 231 49 lb 105 kg 284 lb 129 kg No 42RU 2100 lb 954 kg Not applicable Q NOTE The AC input connector is an IEC 320 C 14 15 A 250 VAC power inlet Cisco UCS C22 M3 High Density SFF Rack Mount Server 57 SUPPLEMENTAL MATERIAL Figure 9 Cisco R42610 Rack Front view door closed Front view door open Front view door removed 58 Cisco UCS C22 M3 High Density SFF Rack Mount Server SUPPLEMENTAL MATERIAL PDUS Cisco RP Series Power Distribution Units PDUS offer power distribution with branch circuit protection Cisco RP Series PDU models distribute power to up to 24 outlets The architecture organizes power distribution simplifies cable management and enables you to move add and change rack equipment without an electrician With a Cisco RP Series PDU in the rack you can replace up to two dozen input power cords with just one The fixed input cord connects to the power source from overhead or under floor distribution Your IT equipment is then powered by PDU outlets in the rack using short easy to manage power cords The C series severs accept the zero rack unit ORU PDU See Figure 10 Figure 10 Zero Rack Unit PDU PID RP208 30 2P U 2 Breakers En C13 plugs Cisco RP Series PDU models provide two 20 ampere A circuit breakers for groups of receptacles The effects of a tripped circu
5. 6 7 2 1600 UCS CPU E52430LB E52430L v2 2 4 60 15 6 7 2 1600 UCS CPU E52420B E52420 v2 2 2 80 15 6 7 2 1600 UCS CPU E52407B E52407 v2 2 4 80 10 4 6 4 1333 UCS CPU E52403B E52403 v2 1 8 80 10 4 6 4 1333 Intel Xeon E5 2400 UCS CPU E5 2470 E5 2470 2 30 95 20 8 8 0 1600 UCS CPU E5 2450 E5 2450 2 10 95 20 8 8 0 1600 UCS CPU E5 2440 E5 2440 2 40 95 15 6 7 2 1333 UCS CPU E5 2430 E5 2430 2 20 95 15 6 7 2 1333 UCS CPU E5 2430L E5 2430L 2 00 60 15 6 6 4 1333 UCS CPU E5 2420 E5 2420 1 90 95 15 6 7 2 1333 UCS CPU E5 2407 E5 2407 2 20 80 10 4 6 4 1066 UCS CPU E5 2403 E5 2403 1 80 80 10 4 6 4 1066 Notes 1 If higher or lower speed DIMMs are selected than what is shown in the table for a given CPU the DIMMs will be clocked at the lowest common denominator of CPU clock and DIMM clock Cisco UCS C22 M3 High Density SFF Rack Mount Server 11 CONFIGURING the SERVER Approved Configurations 1 1 CPU configurations m Select any one CPU listed in Table 3 2 2 CPU Configurations m Select two identical CPUs from any one of the rows of Table 3 on page 11 Caveats m You can select either one CPU or two identical CPUs m If you select one CPU only one PCle slot the full height slot on riser 1 is available for use m For optimal performance select DIMMs with the highest clock speed for a given processor see Table 3 on page 11 If you select DIMMs whose speeds are lower or higher than that shown in the tables suboptimal performance will
6. DIMMs all the DIMMs in the server must be the same speed Cisco UCS C22 M3 High Density SFF Rack Mount Server 51 SUPPLEMENTAL MATERIAL Recommended Memory Population This section explains the recommended DIMM population order rules for the C22 M3 server m All DIMMs must be DDR3 DIMMs m Mixing of Registered and Unbuffered DIMMs is not allowed per platform m Do not mix 1333 MHz DIMMs with 1600 MHz DIMMs Follow Table 27 when populating DIMMs in the server Table 27 Recommended DIMM Population Total DIMMs in Blue Slots Black Slots Blue Slots Black Slots System Bank 1 Bank 2 Bank 1 Bank 2 Al B1 C1 A2 B2 C2 D1 El F1 D2 E2 F2 me ne EE e me EE wa mes wa oea ma e ma mee mea mee owe e Notes 1 For 48 GB there are two possible sweet spot configurations 6 x 8 GB occupies 1 DPC so there is a possibility of increasing total memory size in the system beyond 48 GB by going to 2 DPC while still maintaining memory speed at 1600 MHZ If there is no plan to increase total memory size in the system beyond 48 GB then 12 x 4GB is more price effective at this time 2 For 96 GB there are two possible optimal configurations 6 x 16GB occupies 1 DPC so there is a possibility of increasing total memory size in the system beyond 96 GB by going to 2 DPC while maintaining the maximum memory speed at 1600 MHZ 12 x 8GB gives the peak performance for this configuration and is recommended
7. Service includes flexible hardware replacement options including replacement in as little as two hours There is also access to Cisco s extensive online technical resources to help maintain optimal efficiency and uptime of the unified computing environment You can choose a desired service listed in Table 19 Table 19 Cisco SMART net for UCS Service Product ID PID On Site Description CON PREM C22M3S Yes ONSITE 24X7X2 UCS C22 M3 Server SFF CON OSP C22M3S Yes ONSITE 24X7X4 UCS C22 M3 Server SFF CON OSE C22M3S Yes ONSITE 8X5X4 UCS C22 M3 Server SFF CON OS C22M3S Yes ONSITE 8X5XNBD UCS C22 M3 Server SFF CON S2P C22M3S No SMARTNET 24X7X2 UCS C22 M3 Server SFF CON SNTP C22M3S No SMARTNET 24X7X4 UCS C22 M3 Server SFF CON SNTE C22M3S No SMARTNET 8X5X4 UCS C22 M3 Server SFF CON SNT C22M3S No SMARTNET 8X5XNBD UCS C22 M3 Server SFF Cisco UCS C22 M3 High Density SFF Rack Mount Server 41 CONFIGURING the SERVER SMART net for UCS Hardware Only Service For faster parts replacement than is provided with the standard Cisco Unified Computing System warranty Cisco offers the Cisco SMART net for UCS Hardware Only Service You can choose from two levels of advanced onsite parts replacement coverage in as little as four hours SMART net for UCS Hardware Only Service provides remote access any time to Cisco support professionals who can determine if a return materials authorization RMA is required You can choose a service liste
8. Unit ID Off Unit ID not active LED is integrated into unit ID button On blue Unit ID is activated Cisco UCS C22 M3 High Density SFF Rack Mount Server 61 SUPPLEMENTAL MATERIAL Table 31 Front Panel LEDs continued LED System Status Fan Status Temperature Status Power Supply Status Network Link Status 62 LED State Off On green On amber Blinking amber Off On green On amber Blinking amber Off On green On amber Blinking amber Off On green On amber Blinking amber Off On green Meaning Undefined Server is in normal operating condition Server is in a degraded operational state For example m Power supply redundancy is lost CPUs are mismatched At least one CPU is faulty At least one DIMM is faulty At least one drive in a RAID configuration failed Server is in a critical fault state For example m Boot failed m Fatal CPU and or bus error is detected m Server is in over temperature condition Undefined Fans are operating and no error condition has been detected Fans are in a degraded operational state indicating that one of the fans has a fault Critical fault state indicating that two or more fans have a fault Undefined System is operating at normal temperature and no error conditions have been detected One or more temperature sensors exceeded a warning threshold One or more temperature sensors exceeded a cri
9. dual port Fibre Channel HBA Half UCSC PCIE Q2672 Qlogic QLE2672 CSC 16Gb Fibre Channel HBA with SR Optics Half UCSC PCIE E16002 Emulex LPe16002 M6 16Gb Fibre Channel HBA with SR Optics Half 24 Cisco UCS C22 M3 High Density SFF Rack Mount Server CONFIGURING the SERVER Approved Configurations 1 No PCle RAID controller m If you did not choose a PCle RAID controller for example you selected embedded RAID LSI MegaSR or no RAID controller at all you can select up to one PCle option card listed in Table 8 on page 24 for 1 CPU configurations or up to two cards for 2 CPU configurations 2 One PCle RAID controller m If you selected a PCle RAID controller you cannot select any additional PCle cards for 1 CPU configurations however you can select one additional optional PCle card for 2 CPU configurations NOTE If a PCle RAID controller is installed any optional PCle card you select will be installed in the full height slot RAID controllers are always installed in the half height slot unless you change the OPROM setting to enable the full height slot slot 1 for RAID Caveats m Only a single Cisco UCS 1225 Virtual Interface Card VIC card is supported and it must be installed in the full height slot of riser 1 which is the only slot that supports NCSI m All PCle cards will fit in either riser 1 or riser 2 except the VIC card which must be installed in the full height slot of riser 1 The Cisco 1225
10. for a summary of the supported RAID configuration options Table 29 Supported RAID Configurations Embedded Internal PCle Internal PCle Drives RAID RAID 1 RAID 2 Supported 1 2 Installed ne ms DO Server CPUs PCle Slots C22 M3 SFF Enabled Not allowed Not allowed Installed Enabled Not allowed Not allowed Notes 1 If you want to boot from a device other than the 9270CV 8i 9240 8i or 9220 81 MegaRAID PCle cards you can leave the cards installed Just disable the OPROM for their slots and the system will boot even with the cards installed 2 A available slot O occupied slot U unsupported slot slot 2 is not supported in 1 CPU systems 3 The OPROM is enabled for the default PCle RAID controller slots If you want to enable a different slot you must go into the BIOS and enable the OPROM for the desired slot and disable the OPROM for the default PCle slot see Figure 8 on page 56 Cisco UCS C22 M3 High Density SFF Rack Mount Server 55 SUPPLEMENTAL MATERIAL RAID Option ROM OPROM Settings The server contains an Option ROM OPROM for the PCle slots The server has a finite amount of option ROM with which it can boot up devices Go into the BIOS and disable the OPROM on the PCle slots not used for booting so that resources are available for the slots that are used for booting An example OPROM BIOS screen is shown in Figure 8 Figure 8 Example BIOS Screen for OPROM Aptio Setup Ut
11. if there is no plan of increasing the total memory in the future 52 Cisco UCS C22 M3 High Density SFF Rack Mount Server SUPPLEMENTAL MATERIAL Additional DIMM Populations The list in Table 28 is not a complete list of all supported DIMM populations but highlights common configuration options Table 28 Supported DIMM Configurations Total Total CPU1 CPU1 CPU2 CPU 2 i nk DIMMs Capacity PU2DIMMS DIMMs Capacity eed ae 1 x 4 GB 1 AGB 1x4GB 1 4 GB 2 8 GB 2 x 4 GB 2 8GB 2x4GB 2 8 GB 4 16 GB 1x 8 GB 1 BGB 1x8GB 1 8 GB 2 16 GB 3 x 4 GB 3 12GB 3x4 GB 3 12 GB 6 24 GB 4x4 GB 4 16 GB 4x4GB 4 16 GB 8 32 GB 2 x 8 GB 2 16 GB 2x8 amp GB 2 16 GB 4 32 GB 1 x 16 GB 1 16 GB 1x 16GB 1 16 GB 2 32 GB 5 x 4 GB 5 20GB 5x4GB 5 20 GB 10 40 GB 6 x 4 GB 6 24GB 6x4GB 6 24GB 12 48 GB 3 x 8 GB 3 24GB 3x8 GB 3 24 GB 6 48 GB 4 x 8 GB 4 32 GB 4x8GB 4 32 GB 8 64 GB 2 x 16 GB 2 32 GB 2x16 GB 2 32 GB 4 64 GB 3 x 8 GB 3 x 4 GB 6 36 GB 3x8GB 3x4GB 6 36 GB 12 72 GB 5 x 8 GB 5 40GB 5x8GB 5 40 GB 10 80 GB 6 x 8 GB 6 48GB 6x8GB 6 48 GB 12 96 GB 3 x 16 GB 3 48GB 3x 16 GB 3 48 GB 6 96 GB 3 x 16 GB 3 x 4 GB 6 60GB 3x16GB 3x4GB 6 60 GB 12 120 GB 4x 16 GB 4 64GB 4x 16 GB 4 64 GB 8 128 GB 3x 8 GB 3 x 16 GB 6 72GB 3x8GB 3 x16 GB 6 72 GB 12 144 GB 5 X 16 GB 5 80 GB 5x16 GB 5 80 GB 10 160 GB 6 x 16 GB 6 96 GB 6x16 GB 6 96 GB 12 192 GB 6 x 32 GB 6 192 GB 6x 32 GB 6 192 GB 12 384 GB Notes 1 UCS MR 1X082RY A UCS MR 1X041RY A 2 UCS MR 1X082RY A
12. improve signal quality Table 9 Available Twinax Cables Product ID PID PID Description SFP H10GB CU1M 10GBASE CU SFP Cable 1 M SFP H10GB CU3M 10GBASE CU SFP Cable 3 M SFP H10GB CU5M 10GBASE CU SFP Cable 5 M SFP H10GB ACU7M 10GBASE CU SFP Cable 7 M SFP H10GB ACU10M 10GBASE CU SFP Cable 10 M Approved Configurations 1 Choose Up to Two Twinax Cables for Each Network Card Ordered m You may choose one or two twinax cables for each compatible PCle network card ordered The cables can be different lengths however you would normally order two cables of equal lengths to connect to the primary and redundant network switching equipment Choose Optional SFP Modules Optical Cisco SFP modules are listed in Table 10 Table 10 Available SFP Modules Product ID PID PID Description SFP 10G SR 10GBASE SR SFP Module 850 nm multimode SR 3 3V LC connector with Digital Optical Monitoring DS SFP FC8G SW 8 Gbit SFP Module 850 nm multimode SR 3 3V LC connector with Digital Optical Monitoring 26 Cisco UCS C22 M3 High Density SFF Rack Mount Server CONFIGURING the SERVER Approved Configurations 1 Choose Up to Two SFP Modules for Each Network Card Ordered m You may choose one or two SFP optical modules cables for each compatible PCle network card ordered You would normally order two modules for connecting to the primary and redundant network switching equipment With the SFP optical modules you can u
13. more important the technology becomes to your business These services allow you to Cisco UCS C22 M3 High Density SFF Rack Mount Server Optimize the uptime performance and efficiency of your UCS Protect your vital business applications by rapidly identifying and addressing issues Strengthen in house expertise through knowledge transfer and mentoring Improve operational efficiency by allowing UCS experts to augment your internal staff resources Enhance business agility by diagnosing potential issues before they affect your operations 43 CONFIGURING the SERVER You can choose a service listed in Table 23 Table 23 UCS Computing Combined Support Service Service On nn Product ID PID Level GSP Site Description CON NCF2 C22M3S NCF2 No CMB SPT SVC 24X7X2 UCS C22 M3 Server SFF CON NCF2P C22M3S NCFZP Yes CMB SPT SVC 24X7X20S UCS C22 M3 Server SFF CON NCF4P C22M3S NCF4P Yes CMB SPT SVC 24X7X40S UCS C22 M3 Server SFF CON NCF4S C22M3S NCFAS Yes CMB SPT SVC 8X5X4OS UCS C22 M3 Server SFF CON NCFCS C22M3S NCFCS Yes CMB SPT SVC 8X5XNBDOS UCS C22 M3 Server SFF CON NCFE C22M3S NCFE No CMB SPT SVC 8X5X4 UCS C22 M3 Server SFF CON NCFP C22M3S NCFP No CMB SPT SVC 24X7X4 UCS C22 M3 Server SFF CON NCFT C22M3S NCFT No CMB SPT SVC 8X5XNBD UCS C22 M3 Server SFF Unified Computing Drive Retention Service With the Cisco Unified Computing Drive Retention UCDR Service you can obtain a new disk drive in ex
14. supply see Table 13 Prior to making a power supply selection the UCS Power Calculator should be run to determine the right size power supply for your server configuration A fully configured C22 M3 server may require the 650 W power supply The UCS Power Calculator can be found at the following link https mainstayadvisor com Go Cisco Cisco UCS Power Calculator aspx Table 13 Power Supply PIDs Product ID PID PID Description UCSC PSU 450W 450 W power supply UCSC PSU 650W 650 W power supply Cisco UCS C22 M3 High Density SFF Rack Mount Server 33 CONFIGURING the SERVER STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM The reversible cable management arm mounts on either the right or left slide rails at the rear of the server and is used for cable management Use Table 14 to order a cable management arm Table 14 Cable Management Arm Product ID PID PID Description UCSC CMA1 Cable Management Arm for C22 rack servers NOTE If you order and install a cable management arm you will need the longest Q power cable available For more information about the cable management arm see the Cisco UCS C22 M3 Installation and Service Guide at this URL http www cisco com en US docs unified computing ucs c hw C22 install C22 pdf 34 Cisco UCS C22 M3 High Density SFF Rack Mount Server CONFIGURING the SERVER STEP 11 ORDER A TRUSTED PLATFORM MODULE Trusted Platform Module TPM is a computer chip mic
15. supporting up to eight SAS SATA drives RAID 0 1 5 10 m PCle RAID controllers these consume PCle slots e LSI MegaRAID 9270CV 8i with 1 GB Transportable Memory Module TMM data cache and chassis mounted remote supercap for data cache power backup supporting RAID 0 1 5 6 10 50 and 60 and up to eight internal SAS SATA drives e LSI MegaRAID 9240 81 RAID 8 port PCle RAID controller supporting RAID 0 1 5 10 and 50 and up to eight internal SAS SATA drives e LSI MegaRAID 9220 81 RAID 8 port PCle RAID controller supporting RAID 0 1 and 10 and up to eight internal SAS SATA drives Interfaces m Rear panel e One DB9 serial port connector e Four USB 2 0 port connectors e One DB15 VGA connector e One 10 100 1000 Ethernet management port e Two 1 GbE 10 100 1000 Mbps capable Ethernet LOM ports m Front panel e Two USB 2 0 ports Front Panel m A front panel controller provides status indications and control buttons Power subsystem One 450 W power supply or one 650 W power supply depending on server configuration and loading Prior to making a power supply selection the UCS Power Calculator should be run to determine the right size power supply for your server configuration A fully configured C22 M3 server may require the 650 W power supply The UCS Power Calculator can be found at the following link https mainstayadvisor com Go Cisco Cisco UCS Power Calculator aspx Fans Chassis m Five fans for front to rear coolin
16. the SERVER Table 12 Available Power Cords Product ID PID PID Description Images CAB 9K10A IT Power Cord 250VAC 10A CEI 23 16 VII Plug Italy C15M EN60320 C15 CAB 9K10A SW Power Cord 250VAC 10A MP232 Plug Switzerland iem EE n Length BR Ein 25m ZTN CAB 9K10A UK Power Cord 250VAC 10A BS1363 Plug 13 A fuse UK EE P y aa m Cordset rati BE 250 en Connector I a EL 701C EN 60320 C15 s BS aan i pn fuse 8 CAB 9K12A NA Power Cord 125VAC 13A NEMA 5 15 Plug North America Cordset rating 13A 125V 8 2 feet 2 5m CAB 250V 10A BR Power Cord 250V 10A Brazil ma En Em Nn i m brit D niel CAB JPN 3PIN Power Cord 3PIN Japan Image not available 32 Cisco UCS C22 M3 High Density SFF Rack Mount Server CONFIGURING the SERVER STEP 9 ORDER POWER SUPPLY The C22 M3 server accommodates one power supply A lightly loaded server can operate from one 450 W power supply A fully loaded server might need to be powered with a 650 W power
17. 120 VAC nominal 200 to 240 VAC nominal Range 47 to 63 Hz single phase 50 to 60 Hz nominal 7 6 A maximum at 100 VAC 3 65 A maximum at 208 VAC 11 A peak 35 C 208 VAC 650 W Main power 12 VDC Standby power 12 VDC CSCI Platinum Q NOTE AC input connector is an IEC 320 C 14 15A 250VAC power inlet For configuration specific power specifications use the Cisco UCS Power Calculator at this URL https mainstayadvisor com Go Cisco Cisco UCS Power Calculator aspx 66 Cisco UCS C22 M3 High Density SFF Rack Mount Server TECHNICAL SPECIFICATIONS Environmental Specifications The power specifications for the C22 M3 server are listed in Table 36 Table 36 UCS C22 M3 Environmental Specifications Parameter Minimum Temperature operating 41 to 95 F 5 to 35 C Maximum temperature is to be derated by 1 degree C for every 305 m 1000 ft of altitude above sea level Temperature nonoperating 40 to 149 F 40 to 65 C Humidity RH nonoperating 10 to 90 non condensing Altitude operating O to 3 000 m 0 to 10 000 ft Altitude nonoperating O to 12 192 m 0 to 40 000 ft Sound Power level Measure 5 9 A weighted per ISO7779 LWAd Bels Operation at 73 F 23 C Sound Pressure level Measure 46 A weighted per ISO7779 LpAm dBA Operation at 73 F 23 C Cisco UCS C22 M3 High Density SFF Rack Mount Server 67 TECHNICAL SPECIFICATIONS Compliance Requirements The regulatory
18. 1A RHEL 2S UG 3A RHEL HA 2S 1A RHEL HA 2S 3A RHEL RS 25 1A RHEL RS 25 3A RHEL SFS 2S 1A RHEL SFS 2S 3A BMC BMC 012 BMC SE 4C BMC SE 6C BMC SE 8C BMC SE 10C BMC AE 4C BMC AE 6C BMC AE 8C BMC AE 10C RHEL 2 Socket 1 Guest 1Yr Svcs Required RHEL 2 Socket 1 Guest 3Yr Svcs Required RHEL 2 Socket 4 Guest 1Yr Svcs Required RHEL 2 Socket 4 Guest 3Yr Svcs Required RHEL 2 Socket U Guest 1Yr Svcs Required RHEL 2 Socket U Guest 3Yr Svcs Required RHEL Option High Availability 2 Socket 1Yr Svcs Required RHEL Option High Availability 2 Socket 3Yr Svcs Required RHEL Option Resilient w Ha 2 Socket 1 Yr Svcs Required RHEL Option Resilient Storage w HA 2 Socket 3 Yr Svcs Reqd RHEL Option Scalable File System 2 Socket 1 Yr Svcs Required RHEL Option Scalable File System 2 Socket 1 Yr Svcs Required BMC BPPM Per Server BMC BladeLogic Standard Edition 4 Cores Support Required BMC BladeLogic Standard Edition 6 Cores Support Required BMC BladeLogic Standard Edition 8 Cores Support Required BMC BladeLogic Standard Edition 10 Cores Support Required BMC BladeLogic Advanced Edition 4 Cores Support Required BMC BladeLogic Advanced Edition 6 Cores Support Required BMC BladeLogic Advanced Edition 8 Cores Support Required BMC BladeLogic Standard Edition 10 Cores Support Required Nexus 1000V for Hyper V and vSphere N1K VSG UCS BUN N1K VLEM UCS 1 VSG VLEM UCS 1 UCS Director Over half off N1K and VSG w purchase of UCS B C Series
19. 48 for the location of the internal USB connector Cisco UCS C22 M3 High Density SFF Rack Mount Server CONFIGURING the SERVER STEP 13 SELECT OPERATING SYSTEM AND VALUE ADDED SOFTWARE Several operating systems and value added software programs are available Select as desired from Table 17 Table 17 OSs and Value Added Software for 2 CPU servers PID Description Product ID PID Microsoft Windows Server MSWS 08R2 STHV MSWS 08R2 ENHV MSWS 08R2 DCHV2S MSWS 12 ST2S MSWS 12 DC2S MSWS 12 ST2S NS MSWS 12 DC2S NS MSWS 12R2 ST2S MSWS 12R2 DC2S MSWS 12R2 ST2S NS MSWS 12R2 DC2S NS SUSE SLES SVR 2S 1G 1A SLES SVR 25 1G 3A SLES SVR 25 1G 5A SLES SVR 2S UG 1A SLES SVR 2S UG 3A SLES SVR 2S UG 5A SLES SHA 2S 1A SLES SHA 2S 3A SLES SHA 2S 5A SLES HGC 25 1A SLES HGC 25 3A SLES HGC 25 5A SLES SAP 2S 1G 1A SLES SAP 2S 1G 3A SLES SAP 2S 1G 5A SLES SAP 2S UG 1A SLES SAP 2S UG 3A SLES SAP 2S UG 5A Windows Svr 2008 ST media R2 ST 1 4CPU 5CAL Windows Svr 2008 EN media R2 EN 1 8CPU 25CAL Windows Svr 2008 R2 2 CPU Data Center Windows Server 2012 Standard 2 CPU 2 VMs Windows Server 2012 Datacenter 2 CPU Unlimited VMs Windows Server 2012 Standard 2 CPU 2 VMs No Cisco SVC Windows Server 2012 Datacenter 2 CPU Unlim VM No Cisco SVC Windows Server 2012 R2 Standard 2 CPU 2 VMs Windows Server 2012 R2 Datacenter 2 CPU Unlimited VMs Windows Server 2012 R2 Standard 2 CPU 2 VMs No Cisco SVC Windows Server 2012 R2 D
20. Broadcom 5709 Dual Port Ethernet PCle Adapter for M3 Yes No No Servers N2XX ABPCI03 M3 Broadcom 5709 Quad Port 10 100 1Gb NIC w TOE iSCSI for M3 Use RJ45 Ethernet cable Servers Net Ad Use Intel SFP Intel X520 Dual Port 10Gb SFP Adapter UCSC PCIE ITG Intel X540 Dual Port 10GBase T Adapter UCSC PCIE IRJ45 Intel i350 Quad Port 1Gb Adapter Use RJ45 Ethernet cable UCSC PCIE BTG Yes No No Broadcom 57712 Dual Port 10GBASE T w TOE iSCSI Host Bus Adapters HBAs N2XX AEPCIO3 Emulex LPe 11002 Dual Port 4Gb Fibre Channel HBA Ne Preinstalled do not change SFP N2XX AEPCIO5 Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA Ne Preinstalled do not change SFP N2XX AQPCIO3 QLogic QLE2462 Dual Port 4Gb Fibre Channel HBA Ne Preinstalled do not change SFP 28 Cisco UCS C22 M3 High Density SFF Rack Mount Server PCle Cards CONFIGURING the SERVER Table 11 PCle Card Compatibility continued Cisco SFP Modules PCle Cards Twinax Cables SFP 10G SR DS SFP FC8G SW N2XX AQPCI05 QLogic QLE2562 Dual Port 8Gb Fibre Channel HBA No Preinstalled do not change SFP UCSC PCIE Q2672 Qlogic QLE2672 CSC 16Gb Fibre Channel HBA with SR Optics No Preinstalled do not change SFP UCSC PCIE E16002 Emulex LPe16002 M6 16Gb Fibre Channel HBA with SR Optics Ne Preinstalled do not change SFP Notes 1 This card supports a 4x10 Gbps OSFP to SFP breakout fiber cable Figure 5 Network Card Connections Network P l
21. For more information about the R42610 rack see RACKS page 57 Cisco UCS C22 M3 High Density SFF Rack Mount Server OPTIONAL STEP ORDER PDU OPTIONAL STEP ORDER PDU An optional power distribution unit PDU is available from Cisco for the C Series rack servers including theC22 M3 server This PDU is available in a zero rack unit RU style see Table 25 Table 26 PDU Options Product ID PID PID Description RP208 30 2P U 2 Zero RU PDU For more information about the PDU see PDUS page 59 Cisco UCS C22 M3 High Density SFF Rack Mount Server 47 SUPPLEMENTAL MATERIAL SUPPLEMENTAL MATERIAL CHASSIS An internal view of the C22 M3 chassis with the top cover removed is shown in Figure 6 Figure 6 C22 M3 SFF With Top Cover Off ol gt B SD DD ION OD O e Q O O O on o O OP O O O O O O O O O MO O SS O O O ef APO 285200 Drives RTC battery on motherboard hot swappable acc
22. Hz speeds provided The DIMMs are 1600 MHz devices The CPUs chosen support 1600 MHz operation NOTE 32 GB LRDIMMs run at a maximum speed of 1333 MHz for 1 DPC and 2 DPC even though their specified maximum speed is 1600 MHz Q NOTE In this server 4 GB UDIMMs run slower than their specified maximum speed of 1600 MHz In addition the following rules apply to UDIMMs m 1 DPC 1333 MHz is supported at 1 35 V and 1 5 V m 2 DPC 1066 MHz is supported at 1 35 V and 1 5 V For more information regarding memory see CPUs and DIMMs page 49 Cisco UCS C22 M3 High Density SFF Rack Mount Server CONFIGURING the SERVER STEP 4 SELECT RAID CONFIGURATION NOTE If you do not select a PCle RAID controller or one of the embedded RAID upgrade options you will have an embedded SATA only RAID controller that supports up to four SATA only drives RAID 0 1 10 NOTE When creating a RAID volume follow these guidelines m Use the same capacity for each drive in the volume m Use either all SAS drives or all SATA drives m Use either all HDDs or all SSDs NOTE The number of RAID groups virtual drives supported per controller is as follows note however that this server can have a maximum of only eight internal physical drives m LSI MegaRAID SAS 9270CV 8i RAID controller card 64 m LSI MegaRAID 9240 81 RAID controller card 16 m LSI MegaRAID 9220 81 RAID controller card 16 The RA
23. ID controller choices are 1 Embedded RAID on motherboard Q NOTE Embedded RAID is not available with VMWare NOTE The RAID configuration options listed in Table 6 on page 18 are not available if you choose embedded RAID in this case you must configure RAID yourself using separate software bu 2 PCle RAID controllers Cisco can provide factory configured RAID systems depending on the RAID controller chosen and the number of drives ordered Factory configured RAID options are listed with each RAID card description RAID levels 50 and 60 are supported although they are not available as factory configured RAID options Cisco UCS C22 M3 High Density SFF Rack Mount Server 17 CONFIGURING the SERVER Select RAID Options Select one RAID controller either embedded RAID n Table 5 or hardware RAID using a PCle RAID controller and an appropriate RAID configuration option listed in Table 6 on page 18 Table 5 Available Embedded RAID LSI MegaSR Options Product ID PID PID Description Embedded RAID UCSC RAID ROM5 Onboard RAID consisting of a plug in storage controller unit SCU supporting up to 8 internal SAS SATA drives SAS and SATA drives can be mixed This option supports RAID 0 1 and 10 and operates at 3 Gb s Operating systems supported are Windows and Linux only no VMware support UCSC RAID ROM55 Onboard RAID consisting of two plug in modules an SCU plus a software key module s
24. Nexus 1000V License Paper Delivery 1 CPU for bundles VSG License Paper Delivery 1 CPU for bundles CUIC PHY SERV BM U CUIC PHY SERV U CUIC TERM Cisco Cloupia Resource Lic One Phy Server node bare metal Cisco Cloupia Resource Lic One physical Server node Acceptance of Cisco Cloupia License Terms 38 Cisco UCS C22 M3 High Density SFF Rack Mount Server CONFIGURING the SERVER Table 17 OSs and Value Added Software for 2 CPU servers continued PID Description Product ID PID VMware 5 VMW VS5 STD 1A VMware vSphere 5 Standard for 1 Processor 1 Year Support Rqd VMW VS5 STD 2A VMware vSphere 5 Standard for 1 Processor 2 Year Support Rqd VMW VS5 STD 3A VMware vSphere 5 Standard for 1 Processor 3 Year Support Rad VMW VS5 STD 4A VMware vSphere 5 Standard for 1 Processor 4 Year Support Rad VMW VS5 STD 5A VMware vSphere 5 Standard for 1 Processor 5 Year Support Rad VMW VS5 ENT 1A VMware vSphere 5 Enterprise for 1 Processor 1 Year Support Rad VMW VS5 ENT 2A VMware vSphere 5 Enterprise for 1 CPU 2 Yr Support Rad VMW VS5 ENT 3A VMware vSphere 5 Enterprise for 1 CPU 3 Yr Support Rad VMW VS5 ENT 4A VMware vSphere 5 Enterprise for 1 Processor 4 Year Support Rad VMW VS5 ENT 5A VMware vSphere 5 Enterprise for 1 CPU 5 Yr Support Rad VMW VS5 ENTP 1A VMware vSphere 5 Enterprise Plus for 1 Processor 1 Year Support Rqd VMW VS5 ENTP 2A VMware vSphere 5 Enterprise Plus for 1 CPU 2 Yr Support Rad VMW VS5 ENTP 3A VMware vSphere 5 Ent
25. RAID configuration listed in Table 6 on page 18 NOTE In 1 CPU configurations PCle slot 1 is the default slot supported for an internal drive RAID controller PCle slot 2 is not supported for 1 CPU systems o NOTE If you do not select a PCle RAID controller or one of the embedded RAID upgrade options from Table 5 on page 18 you will have an embedded SATA only RAID controller that supports up to four SATA only drives RAID 0 1 10 and slot 1 can be used for a PCle RAID controller see Table 8 on page 24 2 2 CPU Configurations Select an embedded RAID option from Table 5 on page 18 or one PCle RAID controller from Table 6 on page 18 You may also select an appropriate optional RAID configuration listed in Table 6 on page 18 NOTE In 2 CPU configurations PCle slot 2 is the default slot supported for an internal drive RAID controller PCle slot 1 can be used for a PCle expansion card including the VIC card You can change the default card slot for a RAID controller to slot 1 by going into the BIOS and reconfiguring the option ROM OPROM settings Keep in mind however that if you use slot 1 for a RAID controller you will not be able to install a VIC card which can be installed only in slot 1 NOTE If you do not select a PCle RAID controller or one of the embedded RAID upgrade options from Table 5 on page 18 you will have an embedded SATA only RAID controller that supports up to four SATA on
26. RATING SYSTEM MEDIA KIT page 40 STEP 15 SELECT SERVICE and SUPPORT LEVEL page 41 OPTIONAL STEP ORDER RACK s page 46 OPTIONAL STEP ORDER PDU page 47 Cisco UCS C22 M3 High Density SFF Rack Mount Server 9 CONFIGURING the SERVER STEP 1 VERIFY SERVER SKU Verify the product ID PID of the server as shown in Table 2 Table 2 PID of the C22 M3 High Density SFF Rack Base Server Product ID PID Description UCSC C22 M3S UCS C22 M3 SFF with rail kit without PSU CPU memory HDD SSD or PCle cards The Cisco C22 M3 server m Includes a rail kit UCSC RAIL1 m Does not include power supply CPU memory hard disk drives HDDs solid state drives SSDs or plug in PCle cards Q NOTE Use the steps on the following pages to configure the server with the components that you want to include 10 Cisco UCS C22 M3 High Density SFF Rack Mount Server CONFIGURING the SERVER STEP 2 SELECT CPU s The standard CPU features are m Intel Xeon E5 2400 v2 or E5 2400 series processor family CPUs m Intel C600 chipset m Cache size of up to 25 MB Select CPUs The available CPUs are listed in Table 3 Table 3 Available Intel CPUs Xeon E5 24xx Family Clock Cache Highest DDR3 Er N EN cores GPL Dame MHz Intel Xeon E5 2400 v2 UCS CPU E52470B E52470 v2 2 4 95 25 10 8 0 1600 UCS CPU E52450B E52450 v2 2 5 95 20 8 8 0 1600 UCS CPU E52440B E52440 v2 1 9 95 20 8 7 2 1600 UCS CPU E52430B E52430 v2 2 5 80 15
27. RIAL Figure 7 aa O O gt u D lt D 50 A M A2 ee p B2 C1 NEE C2 D1 D2 Physical Layout of CPU DIMM Channels and Banks CPU1 285209 Cisco UCS C22 M3 High Density SFF Rack Mount Server SUPPLEMENTAL MATERIAL Memory Population Rules When considering the memory configuration of your server you should consider the following items Each channel has two DIMM slots for example channel A slots A1 and A2 Each channel can operate with one or two DIMMs installed If a channel has only one DIMM populate slot 1 first the blue slot When both CPUs are installed populate the DIMM slots of each CPU identically Fill blue sl
28. Spec Sheet CISCO Cisco UCS C22 M3 High Density Rack Mount Server Small Form Factor Hard Disk Drive Model CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR SAN JOSE CA 95134 Rev B 14 JANUARY 5 2015 WWW CISCO COM CONTENTS OVERVIEW 2 ic taeda eat kende ursa DETAILED VIEWS 2 n sk sk ak sk sk ak ai Chassis Front VIEW sous ears SEKER OE we owes RAL SESE SSE ROE ws Chassis Rear View SS SS SS eee eee eee eee eee eee Se BASE SERVER STANDARD CAPABILITIES and FEATURES CONFIGURING the SERVER e ase STEP 1 VERIFY SERVER SKU aaan ee STEP 2 SELECT CPU S aaa oee STEP 3 SELECT MEMORY aaa STEP 4 SELECT RAID CONFIGURATION aaa oen en STEP 5 SELECT DRIVES aaa STEP 6 SELECT PCle OPTION CARD s annen STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES STEP 8 SELECT AC POWER CORD S aaan STEP 9 ORDER POWER SUPPLY aaneen STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM STEP 11 ORDER A TRUSTED PLATFORM MODULE aaa STEP 12 ORDER OPTIONAL USB 2 0 DRIVE anne STEP 13 SELECT OPERATING SYSTEM AND VALUE ADDED SOFTWARE STEP 14 SELECT OPERATING SYSTEM MEDIA KIT aan STEP 15 SELECT SERVICE and SUPPORT LEVEL ee OPTIONAL STEP ORDER RACK S sk ks ke sk es kas 46 OPTIONAL STEP ORDER PDU 0 sk sk sk ak sk ak ee AD SUPPLEMENTAL MATERIAL oi ce sk ak ak ak ak ak tt AG GRASS ae EE EE OT OE TE OE EE EET OE TE IG 48 CPUS ANG BINMMS ent ane eee bo
29. UCS MR 1X041RY A 3 UCS MR 1X162RY A UCS MR 1X041RY A 4 UCS MR 1X162RY A UCS MR 1X041RY A 5 UCS MR 1X082RY A UCS MR 1X162RY A 6 UCS MR 1X082RY A UCS MR 1X162RY A Cisco UCS C22 M3 High Density SFF Rack Mount Server 53 SUPPLEMENTAL MATERIAL Low Voltage DIMM Considerations The C22 M3 server can be ordered with low voltage 1 35 V DIMMs only Note the following considerations m Low voltage DIMMs within the server must have the identical manufacturer type speed and size m Low voltage DIMMs and standard voltage DIMMs can be mixed in the same server Note that this causes the system BIOS to default to standard voltage operation Performance Mode That is the server cannot operate in Power Saving Mode unless all DIMMs are low voltage DIMMs m CPUs that have a maximum memory frequency less than 1333 MHz support low voltage DIMMs operating in Power Saving Mode only and do not support Performance Mode 54 Cisco UCS C22 M3 High Density SFF Rack Mount Server SUPPLEMENTAL MATERIAL RAID Summary m ROM5 and ROM55 embedded RAID upgrade options each support up to 8 drives m The LSI MegaRAID SAS 9270CV 8i 9240 8i and 9220 81 RAID controller cards each support up to 8 drives NOTE If you do not select a PCle RAID controller or one of the embedded RAID l upgrade options ROM5 or ROM55 you will have an embedded SATA only RAID a controller that supports up to four SATA only drives RAID 0 1 10 See Table 29
30. UCS UCWD7 HW ONLY Drive UCS HW DR Retention UCWD5 For more service and support information see the following URL Service Level 24x 7x4 Onsite 8x5xNBD Onsite Product ID PID CON UCWDZ C22M3S CON UCWD5 C22M3S http www cisco com en US services ps2961 ps10312 Unified Computing Services Overview pdf For a complete listing of available services for Cisco Unified Computing System see this URL http www cisco com en US products ps10312 serv_group_home html Cisco UCS C22 M3 High Density SFF Rack Mount Server 45 OPTIONAL STEP ORDER RACK s OPTIONAL STEP ORDER RACK s The optional R42610 rack is available from Cisco for the C Series servers including the C22 M3 SFF server This rack is a standard 19 inch rack and can be ordered with a variety of options as listed in Table 25 Racks are shipped separately from the C22 M3 SFF server 46 Table 25 Racks and Rack Options Product ID PID RACK UCS RACK UCS2 RACK BLANK 001 RACK CBLMGT 001 RACK CBLMGT 011 RACK FASTEN 001 RACK FASTEN 002 RACK JOIN 001 Notes PID Description Cisco R42610 expansion rack no side panels Cisco R42610 standard rack w side panels Filler panels qty 12 1U plastic toolless Cable mgt D rings qty 10 metal Cable mgt straps qty 10 Velcro Mounting screws qty 100 M6 Cage nuts qty 50 M6 Rack joining kit 1 Use these same base PIDs to order spare racks available only as next day replacements
31. VIC card must be plugged into slot 1 which supports NCSI m Additional considerations for the Cisco 1225 VIC card Supports 10G SFP optical and copper twinax connections The server supports installation of only one Cisco VIC 1225 card and it is supported only in PCle slot 1 Slot 1 can operate while the server is in standby power mode Requires that the server has CIMC firmware version 1 4 6 or later installed There is a heartbeat LED on the top of the card that indicates when firmware is active To use this card for UCS integration Cisco UCS Manager mode with Cisco UCS Manager 2 1 0 or later the minimum card firmware and uboot image level is 2 1 0 306 B To help ensure that your operating system is compatible with the card you have selected check the Hardware Compatibility List at this URL http www cisco com en US products ps10477 prod technical reference list html Cisco UCS C22 M3 High Density SFF Rack Mount Server 25 CONFIGURING the SERVER STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES Copper twinax cables and SFP optical modules may be ordered to support the two port network cards that are available with the server Choose Optional Twinax Cables Table 9 lists the copper twinax cables available for the PCle cards You can choose cable lengths of 1 3 5 7 or 10 meters The two longer cables 7 and 10 meters are active which means that they contain active components within the SFP housing to
32. al features of the rear panel Figure 3 Chassis Rear View n Oi poe Ese JE Pce2 MI di SAI ol dls Sse sec AE ae CO ORO SE Da BO 302159 En Power supply on Serial port DB 9 connector Slot 2 Low profile PCle slot on riser 2 VGA video port DB 15 connector PCle Gen 3 slot x8 half height half length Slot 1 Standard profile PCle slot on riser 1 10 100 1000 Base T Ethernet dedicated PCle Gen 3 slot x16 full height half length management port a Dual 1 Gb Base T Ethernet ports two 9 Rear Identification button LED ONE EEN Cisco UCS C22 M3 High Density SFF Rack Mount Server 5 BASE SERVER STANDARD CAPABILITIES and FEATURES BASE SERVER STANDARD CAPABILITIES and FEATURES Table 1 lists the capabilities and features of the base server Details about how to configure the server for a particular feature or capability for example number of processors disk drives or amount of memory are provided in CONFIGURING the SERVER page 9 Table 1 Capabilities and Features Capability Feature Chassis CPU Chipset Memory NIC Expansion slots Internal storage devices Video Description Single rack unit 1RU chassis One or two Intel Xeon E5 2400 v2 or E5 2400 series processor family CPUs Intel C600 chipset 12 DIMM slots Embedded dual port Intel 1350 PCle based Gigabit Ethernet controller Two riser cards with one PCle card slot in each riser m Riser 1 controlled
33. ance 9 in 233 mm Weight Maximum 8 HDDs 2 CPUs 12 DIMMs 1 power supply 27 78 lbs 12 6 kg Bare 0 HDD 0 CPU 0 DIMM no power supply 23 48 lbs 10 65 kg Power Specifications The general power specifications for the C22 M3 SFF server 450 W power supply are listed in Table 34 Table 34 UCS C22 M3 SFF 450 W Power Supply Specifications Description Specification AC input voltage AC input frequency Maximum AC input current Maximum AC inrush current Maximum output power for the power supply Power supply output voltage Power supply efficiency 90 to 264 VAC self ranging 100 to 120 VAC nominal 200 to 240 VAC nominal Range 47 to 63 Hz single phase 50 to 60 Hz nominal 6 A maximum at 100 VAC 3 A maximum at 208 VAC 9 A peak 35 C 208 VAC 450 W Main power 12 VDC Standby power 12 VDC CSCI Platinum Cisco UCS C22 M3 High Density SFF Rack Mount Server 65 TECHNICAL SPECIFICATIONS Q NOTE AC input connector is an IEC 320 C 14 15A 250VAC power inlet The general power specifications for the C22 M3 SFF server 650 W power supply are listed in Table 34 Table 35 UCS C22 M3 SFF 650 W Power Supply Specifications Description Specification AC input voltage AC input frequency Maximum AC input current Maximum AC inrush current Maximum output power for the power supply Power supply output voltage Power supply efficiency 90 to 264 VAC self ranging 100 to
34. atacen 2 CPU Unlim VM No Cisco Svc SUSE Linux Enterprise Srvr 1 2 CPU 1 Phys SUSE Linux Enterprise Srvr 1 2 CPU 1 Phys SUSE Linux Enterprise Srvr 1 2 CPU 1 Phys SUSE Linux Enterprise Svr 1 2 CPU Unl Vrt SUSE Linux Enterprise Svr 1 2 CPU Unl Vrt SUSE Linux Enterprise Svr 1 2 CPU Unl Vrt 5yr Support Reqd SUSE Linux High Availability Ext 1 2 CPU 1yr Support Reqd SUSE Linux High Availability Ext 1 2 CPU 3yr Support Reqd SUSE Linux High Availability Ext 1 2 CPU 5yr Support Reqd SUSE Linux GEO Clustering for HA 1 2 CPU 1yr Support Reqd SUSE Linux GEO Clustering for HA 1 2 CPU 3yr Support Reqd SUSE Linux GEO Clustering for HA 1 2 CPU 5yr Support Reqd SLES for SAP Applications 1 2 CPU 1 Phys 1yr Support Reqd SLES for SAP Applications 1 2 CPU 1 Phys 3yr Support Reqd SLES for SAP Applications 1 2 CPU 1 Phys 5yr Support Reqd SLES for SAP Applications 1 2 CPU Unl Vrt 1yr Support Reqd 1yr Support Reqd 3yr Support Reqd Dyr Support Reqd 1yr Support Reqd 3yr Support Reqd v SLES for SAP Applications 1 2 CPU Unl Vrt 3yr Support Reqd SLES for SAP Applications 1 2 CPU Unl Vrt 5yr Support Reqd Cisco UCS C22 M3 High Density SFF Rack Mount Server 37 CONFIGURING the SERVER Table 17 OSs and Value Added Software for 2 CPU servers continued PID Description Product ID PID Red Hat Enterprise Linux RHEL 25 1G 1A RHEL 25 1G 3A RHEL 25 4G 1A RHEL 25 4G 3A RHEL 25 UG
35. by CPU 1 e Slot 1 PCle Gen 3 slot x16 extended connector Cisco CNIC half length full height with NCSI and Cisco CNIC support The Cisco 1225 virtual interface card requires an NCSI slot m Riser 2 controlled by CPU 2 e Slot 2 PCle Gen 3 slot x8 connector half length half height no NCSI support m Up to eight 2 5 inch SAS SATA hot swappable hard disk drives HDDs or solid state drives SSDs m One connector on the motherboard that can accommodate a USB 2 0 drive You can order an 8 or 16 GB drive for this connector and use it as a hypervisor or license dongle The 8 or 16 GB USB drive comes blank The Emulex Pilot 3 Integrated Baseboard Management Controller provides video m Matrox G200e video controller m Integrated 2D graphics core with hardware acceleration m Supports all display resolutions up to 1920 x 1200 x 16 bpp resolution at 60 Hz m 24 bit color depth for all resolutions less than 1600x1200 m 8 MB video memory Cisco UCS C22 M3 High Density SFF Rack Mount Server BASE SERVER STANDARD CAPABILITIES and FEATURES Capability Feature Description Storage controller The following RAID options are available m Embedded RAID 3 Gbps these implementations of RAID do not consume a PCle slot e Embedded SATA only RAID controller supporting up to four SATA only drives RAID 0 1 10 or e ROM5 RAID upgrade supporting up to eight SAS SATA drives RAID 0 1 10 or e ROM55 RAID upgrade
36. change for a faulty drive without returning the faulty drive In exchange for a Cisco replacement drive you provide a signed Certificate of Destruction CoD confirming that the drive has been removed from the system listed is no longer in service and has been destroyed Sophisticated data recovery techniques have made classified proprietary and confidential information vulnerable even on malfunctioning disk drives The UCDR service enables you to retain your drives and ensures that the sensitive data on those drives is not compromised which reduces the risk of any potential liabilities This service also enables you to comply with regulatory local and federal requirements If your company has a need to control confidential classified sensitive or proprietary data you might want to consider one of the Drive Retention Services listed in Table 24 Q kom NOTE Cisco does not offer a certified drive destruction service as part of this service Table 24 Drive Retention Service Options i en Service Service Service Description Program Name Level GSP Service Level Product ID PID SMART net for UCS UCSD7 24x7x4 Onsite CON UCSD7 C22M3S Service with Drive UCS DR Retention UCSD7 8x5xNBD Onsite CON UCSD5 C22M3S 44 Cisco UCS C22 M3 High Density SFF Rack Mount Server CONFIGURING the SERVER Table 24 Drive Retention Service Options continued Service Description service Service Program Name Level GSP SMART net for
37. compliance requirements for C Series servers are listed in Table 37 Table 37 UCS C Series Regulatory Compliance Requirements Parameter Description Regulatory Compliance Products should comply with CE Markings per directives 2004 108 EC and 2006 95 EC Safety UL 60950 1 Second Edition CAN CSA C22 2 No 60950 1 Second Edition EN 60950 1 Second Edition IEC 60950 1 Second Edition AS NZS 60950 1 GB4943 2001 EMC Emissions 47CFR Part 15 CFR 47 Class A AS NZS CISPR22 Class A CISPR22 Class A EN55022 Class A ICESOO3 Class A VCCI Class A EN61000 3 2 EN61000 3 3 KN22 Class A CNS13438 Class A EMC Immunity EN55024 CISPR24 EN300386 KN24 leerde Americas Headquarters Asia Pacific Headquarters Europe Headquarters Casco Systems Inc Cisco Systems USA Pte Lid Cisco Systems International BV Amsterdam San Jose CA singapore The Netherlands Casco has more than 200 offices worldwide Addresses phone numbers and fax numbers are listed on the Cisco Website al www cisco com go olfices Cesco and the Cisco Logo are trademarks of Cisco Systems Inc and or its affikates in the US and other countries A listing of Cisco s trademarks can be found at wwwcmcocom go lrademarks Third party trademarks mentioned are the property of their respective owners The use of the word partner does not imply a parinership relationship between Cisco and any other company 1005R 68 Cisco UCS C22 M3 High Density SFF Rack Mount Server
38. d in Table 20 Table 20 SMART net for UCS Hardware Only Service Service On er Product ID PID Level GSP Site Description CON UCW7 C22M3S UCW7 Yes UC PLUS 24X7X40S UCS C22 M3 Server SFF CON UCW5 C22M3S UCW5 Yes UC PLUS 8X5XNBDOS UCS C22 M3 Server SFF Unified Computing Partner Support Service Cisco Partner Support Service PSS is a Cisco Collaborative Services service offering that is designed for partners to deliver their own branded support and managed services to enterprise customers Cisco PSS provides partners with access to Cisco s support infrastructure and assets to help them m Expand their service portfolios to support the most complex network environments m Lower delivery costs m Deliver services that increase customer loyalty Partner Unified Computing Support Options enable eligible Cisco partners to develop and consistently deliver high value technical support that capitalizes on Cisco intellectual assets This helps partners to realize higher margins and expand their practice PSS is available to all Cisco PSS partners but requires additional specializations and requirements For additional information see the following URL www cisco com go partnerucssupport The two Partner Unified Computing Support Options include m Partner Support Service for UCS m Partner Support Service for UCS Hardware Only Partner Support Service for UCS provides hardware and software support including triage support for third pa
39. e Card Optical SFP Modules pr Fiber Optic Cables aes f iy a zi ad Redundant Top of Rack E Access Switches i Jae Network PCle Card T bes winax Copper Cables ee CT en Redundant Top of Rack X Access Switches RE Cisco UCS C22 M3 High Density SFF Rack Mount Server 29 CONFIGURING the SERVER STEP 8 SELECT AC POWER CORD s Using Table 12 select the appropriate AC power cords You can select a minimum of no power cords and a maximum of two If you select the option R2XX DMYMPWRCORD no power cord is shipped with the server Table 12 Available Power Cords Product ID PID PID Description Images R2XX DMYMPWRCORD No power cord dummy PID to Not applicable allow for a no power cord option CAB N5K6A NA Power Cord 200 240V 6A North America CAB AC L620 C13 AC Power Cord NEMA L6 20 C13 z 2M 6 5ft TE n ER CELF TH em CAB C13 CBN CABASY WIRE JUMPER CORD 27 L C13 C14 10A 250V CAB C13 C14 2M CABASY WIRE JUMPER CORD PWR 2 Meter C13 C14 10A 250V CAB C13 C14 AC CORD PWR JMP IEC60320 C14 IEC6 0320 C13 3 0M ra ES Er ee 30 Cisco UCS C22 M3 High Density SFF Rack Mount Server CONFIGURING the SERVER Table 12 Available Power Cords Product ID PID SFS 250V 10A AR CAB 9K10A AU SFS 250V 10A CN CAB 250V 10A CN
40. e card from Table 8 on page 24 to be installed in slot 1 B The optional PCle RAID controllers are all half height If you choose one of these cards in a 2 CPU configuration only the full height PCle card slot will be available for an additional optional PCle card m Note that only a single Cisco UCS 1225 Virtual Interface Card VIC card is supported and it must be installed in the full length full height PCle slot slot 1 on riser 1 which is the only slot that supports NCSI So take this into account when populating RAID controller cards m You can choose only one type of RAID controller either embedded RAID or a PCle RAID controller If you choose embedded RAID slot 1 in a 1 CPU system and slots 1 and 2 in a 2 CPU system are available for adding optional PCle cards m For PCle RAID controllers you can choose an optional RAID configuration RAID 0 1 5 6 or 10 which is preconfigured at the factory The RAID level you choose must be an available RAID choice for the controller selected RAID levels 50 and 60 are supported depending on the RAID controller selected although they are not available as configuration options Q NOTE For more important information regarding RAID support see RAID Summary page 55 and RAID Option ROM OPROM Settings page 56 Cisco UCS C22 M3 High Density SFF Rack Mount Server 21 CONFIGURING the SERVER STEP 5 SELECT DRIVES The standard disk drive features are B 2 5 inch small fo
41. e standard PCle card offerings are m Converged Network Adapters CNAs B Network Interface Cards NICs m Host Bus Adapters HBAs Select PCle Option Cards The available PCle option cards are listed in Table 8 Table 8 Available PCle Option Cards Product ID PID PID Description Baak Converged Network Adapters CNAs _UCSC PCIE CSC 02 Cisco VIC 1225 Dual Port 10Gb SFP CNA Half UCSC PCIE C10T 02 Cisco VIC 1225T Dual Port 10GBaseT CNA Half UCSC PCIE C40Q 02 Cisco VIC 1285 Dual Port 40Gb QSFP CNA Half UCSC PCIE ESFP Emulex OCe11102 FX dual port 10 GbE FCoE CNA Half UCSC PCIE Q8362 Qlogic QLE8362 dual port 10 GbE FCoE CNA Half Network Interface Cards NICs N2XX ABPCI01 M3 Broadcom 5709 Dual Port Ethernet PCle Adapter w TOE for M3 Servers Half N2XX ABPCI03 M3 Broadcom 5709 Quad Port 10 100 1Gb NIC w TOE iSCSI for M3 Servers Half UCSC PCIE BTG Broadcom 57712 Dual Port 10GbE 10G BaseT w TOE Half N2XX AIPCIO1 Intel 10GbE 2 Port Niantec Controller with Copper SFP Cable Half UCSC PCIE IRJ45 Intel Quad Port GbE controller this is a quad port 1350 controller Half UCSC PCIE ITG Intel X540 Dual Port 10GBase T Adapter Half UCSC PCIE B3SFP BROADCOM 57810 10Gb AFEX SFP Half Host Bus Adapters HBAs N2XX AEPCIO3 Emulex LPe 11002 4Gb Fibre Channel PCle Dual Channel HBA Half N2XX AEPCIO5 Emulex LPe 12002 8Gb dual port Fibre Channel HBA Half N2XX AQPCI03 Qlogic QLE2462 4Gb dual port Fibre Channel HBA Half N2XX AQPCI05 Qlogic QLE2562 8Gb
42. erprise Plus for 1 Processor 3 Year Support Rqd VMW VS5 ENTP 4A VMware vSphere 5 Enterprise Plus for 1 Processor 4 Year Support Rqd VMW VS5 ENTP 5A VMware vSphere 5 Enterprise Plus for 1 Processor 5 Year Support Rqd VMW VC5 STD 1A VMware vCenter 5 Server Standard 1 yr support required VMW VC5 STD 2A VMware vCenter 5 Server Standard 2 yr support required VMW VC5 STD 3A VMware vCenter 5 Server Standard 3 yr support required VMW VC5 STD 4A VMware vCenter 5 Server Standard 4 yr support required VMW VC5 STD 5A VMware vCenter 5 Server Standard 5 yr support required UCS VMW TERMS Acceptance of Terms Standalone VMW License for UCS Servers Cisco UCS C22 M3 High Density SFF Rack Mount Server 39 CONFIGURING the SERVER STEP 14 SELECT OPERATING SYSTEM MEDIA KIT Select the optional operating system media listed in Table 18 Table 18 OS Media Product ID PID PID Description RHEL 6 RHEL 6 Recovery Media Only Multilingual SLES 11 SLES 11 media only multilingual MSWS 08R2 STHV RM Windows Svr 2008 R2 ST 1 4CPU 5CAL Media MSWS 08R2 ENHV RM Windows Svr 2008 R2 EN 1 8CPU 25CAL Media MSWS 08R2 DCHV RM Windows Svr 2008 R2 DC 1 8CPU 25CAL Media MSWS 12 ST2S RM Windows Server 2012 Standard 2 CPU 2 VMs Recovery Media MSWS 12 DC2S RM Windows Server 2012 Datacenter 2 CPU Unlimited VM Rec Media MSWS 12R2 ST2S RM Windows Server 2012 R2 Standard 2 CPU 2 VMs Recovery Media MSWS 12R2 DC2S RM Windows Server 2012 R2 Datacen 2 CPU Unlim
43. essed through front panel Front panel operations board PCle riser 2 PCle slot 2 Power supply Cooling fans five accessed through rear panel Drive backplane Trusted platform module socket on motherboard not visible under PCle riser 2 48 Cisco UCS C22 M3 High Density SFF Rack Mount Server SUPPLEMENTAL MATERIAL DIMM slots on motherboard 12 Integrated SAS RAID connectors on motherboard left to right SCU Port 0 SCU_Port 1 CPU and heatsinks 2 Software RAID 5 key header on motherboard PCle riser 1 PCle slot 1 RAID SCU option ROM header on motherboard Internal USB 2 0 port on motherboard under PCle riser 1 RAID backup unit Mounting point for SuperCap power module CPUs and DIMMs Physical Layout Each CPU has three DIMM channels m CPU1 has channels A B and C m CPU 2 has channels D E and F Each DIMM channel has two banks Bank 1 and Bank 2 The blue colored DIMM banks are for Bank 1 and the black colored are for Bank 2 As an example DIMM slots A1 B1 and C1 belong to Bank 1 while A2 B2 and C2 belong to Bank 2 Figure 7 shows how banks and channels are physically laid out on the motherboard The DIMM slots on the top channels A B and C are associated with CPU 1 while the DIMM slots on the bottom channels D E and F are associated with CPU 2 Bank 1 slots blue are populated before Bank 2 slots black Cisco UCS C22 M3 High Density SFF Rack Mount Server 49 SUPPLEMENTAL MATE
44. g N 1 redundant Power supply m The power supply is equipped with a fan Cisco UCS C22 M3 High Density SFF Rack Mount Server 7 BASE SERVER STANDARD CAPABILITIES and FEATURES Capability Feature Description Integrated management Cisco Integrated Management Controller CIMC processor Depending on your CIMC settings the CIMC can be accessed through the 1 Gb Ethernet dedicated management port the 1 Gb Ethernet LOM ports or a Cisco 1225 virtual interface card Notes 1 NCSI network communications services interface protocol The slot stays active when the server is in standby power state 2 CNIC Cisco network interface card Cisco UCS C22 M3 High Density SFF Rack Mount Server CONFIGURING the SERVER CONFIGURING the SERVER Follow these steps to configure the Cisco UCS C22 M3 High Density SFF Rack Server STEP 1 VERIFY SERVER SKU page 10 STEP 2 SELECT CPU s page 11 STEP 3 SELECT MEMORY page 13 STEP 4 SELECT RAID CONFIGURATION page 17 STEP 5 SELECT DRIVES page 22 STEP 6 SELECT PCle OPTION CARD s page 24 STEP 7 ORDER OPTIONAL NET WORK CARD ACCESSORIES page 26 STEP 8 SELECT AC POWER CORD s page 30 STEP 9 ORDER POWER SUPPLY page 33 STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM page 34 STEP 11 ORDER A TRUSTED PLAT FORM MODULE page 35 STEP 12 ORDER OPTIONAL USB 2 0 DRIVE page 36 STEP 13 SELECT OPERATING SYSTEM AND VALUE ADDED SOFT WARE page 37 STEP 14 SELECT OPE
45. ility Copyright 0 2011 American Megatrends Inc re Advance AA b PCIe Link Speed Configuration Cont Lgu Pe POTE Bank SPEEN TON PCIe Root Forts LOM Port 0 Legacy OptionROM LOM Port 1 Legacy OptionROM All PCIe Slots Oot ionRow Enabled PCIe SlotID 1 OptionROH Enabled PCIe SlotID 2 Opt LonROM Enabled version 2 14 1219 Copyright tC 2011 American Megatrends Inc 56 Cisco UCS C22 M3 High Density SFF Rack Mount Server SUPPLEMENTAL MATERIAL RACKS The Cisco R42610 rack see Figure 9 is certified for Cisco UCS installation at customer sites and is suitable for the following equipment m Cisco UCS B Series servers and fabric interconnects m Cisco UCS C Series and select Nexus switches The rack is compatible with hardware designed for ElA standard 19 inch racks Rack specifications are listed in Table 30 Table 30 Cisco R42610 Rack Specifications Parameter Dimensions H x W x D Dimensions H x W x D with packaging Distance from front mounting rail to rear mounting rail Weight Weight with packaging Side panels included Equipment mounting capacity Static load capacity Dynamic load capacity Standard Rack 78 74 x 24 x 43 38 in 2000 x 610 x 1102 mm 89 x 33 X 47 in 2261 x 838 x 1194 mm 29 2 in 741 mm 299 83 lb 136 kg 354 ID 161 kg Yes 42RU 2100 lb 954 kg Not applicable Expansion Rack 78 74 x 23 58 X 43 38 in 2000 x 599 x
46. it are limited to a receptacle group Simply press a button to reset that circuit Cisco UCS C22 M3 High Density SFF Rack Mount Server 59 SUPPLEMENTAL MATERIAL Motherboard USB Port The C22 M3 SFF motherboard has one general purpose USB socket as shown in Figure 11 Figure 11 Motherboard USB Port EER 3 twa zi C3 i 1 2 Y ST ZR N EI vr dij Jho nl 55 FANS oft bp jame Lem die O O O O O O O O O Oe OP O oe O we O a O Ke O O aa ee Internal USB 2 0 port on motherboard under PCle riser 1 60 Cisco UCS C22 M3 High Density SFF Rack Mount Server SUPPLEMENTAL MATERIAL LED Indicators The server contains LED indicators on the front and rear panels Their functions are described in the following sections Front Panel Figure 12 shows the front panel LEDs Figure 12 Front Panel LEDs ae EN EEN Ee EE o eea EE ene EE See Table 31 for the functions of the front panel LEDs Table 31 Front Panel LEDs LED LED State Meaning Power Off Server power is off LED is integrated into power button On amber Server power is soft off power is supplied only to the CIMC and some motherboard functions On green Card power is on
47. ited VM Rec Media 40 Cisco UCS C22 M3 High Density SFF Rack Mount Server CONFIGURING the SERVER STEP 15 SELECT SERVICE and SUPPORT LEVEL A variety of service options are available as described in this section Unified Computing Warranty No Contract If you have noncritical implementations and choose to have no service contract the following coverage is supplied m Three year parts coverage Next business day NBD onsite parts replacement eight hours a day five days a week 90 day software warranty on media Ongoing downloads of BIOS drivers and firmware updates UCSM updates for systems with Unified Computing System Manager These updates include minor enhancements and bug fixes that are designed to maintain the compliance of UCSM with published specifications release notes and industry standards SMART net for UCS For support of the entire Unified Computing System Cisco offers the Cisco SMART net for UCS Service This service provides expert software and hardware support to help sustain performance and high availability of the unified computing environment Access to Cisco Technical Assistance Center TAC is provided around the clock from anywhere in the world For UCS blade servers there is Smart Call Home which provides proactive embedded diagnostics and real time alerts For systems that include Unified Computing System Manager the support service includes downloads of UCSM upgrades The Cisco SMARTnet for UCS
48. ly drives RAID 0 1 10 and slots 1 and 2 can be used for PCle cards see Table 8 on page 24 Caveats In 1 CPU configurations there is only one full height PCle slot available located on riser 1 Slot 2 is not supported in 1 CPU systems If you choose embedded RAID you can select one optional PCle card from Table 8 on page 24 to be installed in slot 1 If you choose a PCle RAID controller from Table 5 on page 18 it will be installed in slot 1 by default and you will not be able to select any optional PCle card from Table 8 on page 24 Cisco UCS C22 M3 High Density SFF Rack Mount Server CONFIGURING the SERVER Note that only a single Cisco 1225 Virtual Interface Card VIC card is supported and it must be installed in the full length full height PCle slot slot 1 on riser 1 which is the only slot that supports NCSI So take this into account when populating RAID controller cards You can have either a PCle RAID controller or a VIC card in slot 1 Slot 2 is not supported in 1 CPU systems m In 2 CPU configurations there are two PCle slots available one full height slot slot 1 and one half height slot slot 2 If you choose embedded RAID you can select up to two optional PCle cards from Table 8 on page 24 to be installed in slots 1 and 2 If you choose a PCle RAID controller from Table 5 on page 18 it will be installed in slot 2 by default and you will be able to select one additional optional PCl
49. ly one of the two populated channels provides data Table 4 Available DDR3 DIMMs Product ID PID PID Description Voltage jie DIMM Options UCS MR 1X041RY A AGB DDR3 1600 MHz RDIMM PC3 12800 1R x4 1 35v 1 35 V 1 UCS MR 1X082RY A 8GB DDR3 1600 MHz RDIMM PC3 12800 2R x4 1 35v 1 35 V 2 UCS MR 1X162RY A 16GB DDR3 1600 MHz RDIMM PC3 12800 2R x4 1 35v 1 35 V 2 UCS ML 1X324RY A 32GB DDR3 1600 MHz LR DIMM PC3 12800 4R x4 1 35v 1 35 V 4 Memory Mirroring Option NO1 MMIRROR Memory mirroring option 14 Cisco UCS C22 M3 High Density SFF Rack Mount Server CONFIGURING the SERVER Approved Configurations 1 1 CPU configuration without memory mirroring m Select from 1 to 6 DIMMs Refer to Memory Population Rules page 51 for more detailed information 2 1 CPU configuration with memory mirroring m Select either 2 or 4 DIMMs The DIMMs will be placed by the factory as shown in the following table Number of DIMM Placement in Channels DIMMs Channel A is not used with memory mirroring 2 CPU 1 1 DIMM in Channel B 1 DIMM in Channel C 4 CPU 1 2 DIMMs in Channel B 2 DIMMs in Channel C m Select the memory mirroring option NO1 MMIRROR as shown in Table 4 on page 14 1 2 CPU configuration without memory mirroring m Select from 1 to 6 DIMMs per CPU 2 to 12 DIMMs total Refer to Memory Population Rules page 51 for more detailed information 2 2 CPU configuration with memory mirroring m Select 2 or 4 DIMMs per CPU
50. ots in the channels first A1 D1 B1 E1 C1 F1 Fill black slots in the channels second A2 D2 B2 E2 C2 F2 Any DIMM installed in a DIMM socket for which the CPU is absent is not recognized For optimum performance populate at least one DIMM per memory channel per CPU When populating DIMM slots multiples of 6 DIMMs are best for achieving optimum performance since there are 3 memory channels per CPU socket and 2 CPUs must be populated At 1 DPC and 2 DPC 1600 MHz DIMMS will run at 1600 MHz provided the CPU supports 1600 MHz DIMMs and 1333 MHz DIMMs will run at 1333 MHz When mixing DIMMs the following rules need to be followed When mixing DIMMs of different densities sizes populate DIMMs with the highest density first For example if you have to mix 16 GB with 8 GB DIMMs populate 16 GB DIMMs in blue slots or bank 1 and then 8 GB in black slots or bank 2 When mixing DIMMs with different ranks populate DIMMs with the higher rank first For example populate 16 GB 2R or 8 GB 2R before 4 GB 1R DIMMs DIMMs of different sizes 4 GB 8 GB 16 GB can be mixed within a channel Total memory size in each single channel should be the same For example if you are mixing 4 GB and 8 GB DIMMs to achieve total 72 GB 6x8 GB 6x4 GB for a server then populate blue slots with 8 GB DIMMs and black slots with 4 GB DIMMs and total memory size should be 12 GB for each of the 3 channels for both CPUs When mixing
51. ported per controller is as follows Nd m LSI MegaRAID SAS 9270CV 8i RAID controller card 64 m LSI MegaRAID 9240 8i RAID controller card 16 m LSI MegaRAID 9220 81 RAID controller card 16 Approved Configurations 1 Embedded RAID LSI MegaSR m Select up to eight SAS SATA drives note that none of the RAID configuration options listed in Table 6 on page 18 can be chosen for embedded RAID You can mix SAS and SATA drives 2 LSI MegaRAID 9270CV 8i with data cache and supercap LSI MegaRAID 9240 8i and LSI MegaRAID 9220 8i m Select up to eight SAS SATA drives listed in Table 7 on page 22 You can mix SAS and SATA drives 3 None of the Above m If you did not select embedded RAID or a PCle RAID controller you can only select up to four SATA drives which will be controlled by the embedded SATA only RAID controller Caveats m You can mix SATA and SAS drives m If you select one or more SAS drives you must select either a PCle RAID controller from Table 6 on page 18 or an embedded RAID option from Table 5 on page 18 m If you select four or less SATA only drives you can select a PCle RAID controller from Table 6 on page 18 or an embedded RAID option from Table 5 on page 18 or neither If you select neither the drives will be controlled by the embedded SATA only RAID controller Cisco UCS C22 M3 High Density SFF Rack Mount Server 23 CONFIGURING the SERVER STEP 6 SELECT PCle OPTION CARD s Th
52. pply AC LED State Off Blinking amber On amber Off Blinking green On green Meaning The power supply is operating normally An event warning threshold has been reached but the power supply continues to operate A critical fault threshold has been reached causing the power supply to shut down for example a fan failure or an over temperature condition There is no AC power to the power supply AC power OK DC output not enabled AC power OK DC outputs OK 1GbE Link Speed 1GbE Link Status 10 100 1000 Base T Link Status 10 100 1000 Base T Link Speed Off On amber On green Off On green Blinking green Off On green Blinking green Off On amber On green Link Speed 10 Mbps Link Speed 100 Mbps Link Speed 1 Gbps No Link Link is active Traffic is present on the active link No Link Link is active Traffic is present on the active link Link Speed 10 Mbps Link Speed 100 Mbps Link Speed 1 Gbps Unit ID LED is integrated into unit ID button 64 Off On blue Unit ID not active Unit ID is activated Cisco UCS C22 M3 High Density SFF Rack Mount Server TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Dimensions and Weight Table 33 UCS C22 M3 Dimensions and Weight Parameter Value Height 1 70 in 43 2 mm Width 16 93 in 430 mm Depth 26 0 in 660 4 mm Front Clearance 3 in 76 mm Side Clearance 1 in 25 mm Rear Clear
53. result 12 Cisco UCS C22 M3 High Density SFF Rack Mount Server CONFIGURING the SERVER STEP 3 SELECT MEMORY The standard memory features are m DIMMs Clock speed 1600 or 1333 MHz Ranks per DIMM 1 2 or 4 Operational voltage 1 35 V or 1 5 V Registered ECC DDR3 DIMMS RDIMMS unregistered DIMMs UDIMMS or load reduced DIMMs LRDIMMs B Memory is organized with three memory channels per CPU with up to two DIMMs per channel as shown in Figure 4 Figure 4 C22 M3 SFF Memory Organization 2 3 z 2 Et E Bm f a g a DI D2 Chan D Chan E Chan F 12 DIMM sockets 3 memory channels per CPU up to 2 DIMMs per channel Cisco UCS C22 M3 High Density SFF Rack Mount Server 13 CONFIGURING the SERVER Select DIMMs Select the memory configuration The available memory DIMMs are listed in Table 4 NOTE When memory mirroring is enabled the memory subsystem simultaneously writes identical data to two channels If a memory read from one of the channels returns incorrect data due to an uncorrectable memory error the system automatically retrieves the data from the other channel A transient or soft error in one channel does not affect the mirrored data and operation continues unless there is a simultaneous error in exactly the same location on a DIMM and its mirrored DIMM Memory mirroring reduces the amount of memory available to the operating system by 50 because on
54. rm factor B Hot pluggable m Sled mounted Select Drives The available drives are listed in Table 7 Table 7 Available Hot Pluggable Sled Mounted HDDs or SSDs Product ID PID PID Description Capacity HDDs UCS HDD250G1F111 250 GB 6Gb SATA 7 2K RPM SATA 250 GB UCS HDD300GI2F105 300 GB 6Gb SAS 15K RPM SFF SAS 300 GB A03 D300GA2 300 GB 6Gb SAS 10K RPM SFF SAS 300 GB A03 D500GC3 500 GB SATA 7 2K RPM SFF SATA 500 GB A03 D600GA2 600 GB 6Gb SAS 10K RPM SFF SAS 600 GB UCS HDD900GI2F106 900 GB 6Gb SAS 10K RPM SFF SAS 600 GB A03 D1TBSATA 1 TB SATA 7 2K RPM SFF SATA 1 TB SSDs UCS SD200GOKS2 EP 200 GB 2 5 inch Enterprise Performance SAS SAS 200 GB UCS SD400GOKS2 EP 400 GB 2 5 inch Enterprise Performance SAS SAS 400 GB UCS SD800GOKS2 EP 800 GB 2 5 inch Enterprise Performance SAS SAS 800 GB UCS SD480GOKS2 EV 480 GB 2 5 inch Enterprise Value 6 G SATA SSD SATA 480 GB UCS SD240GOKS2 EV 240 GB 2 5 inch Enterprise Value 6 G SATA SSD SATA 240 GB UCS SD120GOKS2 EV 120 GB 2 5 inch Enterprise Value 6 G SATA SSD SATA 120 GB UCS SD100GOKA2 G 100 GB Read SSD SATA 100 GB UCS SD400GOKA2 G 400 GB Read SSD SATA 400 GB 22 Cisco UCS C22 M3 High Density SFF Rack Mount Server CONFIGURING the SERVER NOTE When creating a RAID volume follow these guidelines G m Use the same capacity for each drive in the volume m Use either all SAS drives or all SATA drives m Use either all HDDs or all SSDs NOTE The number of RAID groups virtual drives sup
55. ro ne obese ken E Eb SD sa KEE a oe 49 Mile NE ie vs AAR APE TOT ON EER SO EF ORE RE deens 49 Memory Population Rules ss ss ss ss ee ss ss ss ss se ss SS ee se 51 Recommended Memory Population eee eee eee ee 52 Additional DIMM Populations ss ss ss 0 cc ee ee ee ss ss eee eee eee 53 Low Voltage DIMM Considerations 2 2 cee eee ee eee eee eee 54 RAID SUMING siese ee nn na he eae ee 55 RAID Option ROM OPROM Settings eee ee eee eee eee ee 56 RACKS mannen eneen REN Reen 57 POUS 4 AE EET ER ET ETE ORE DERDES 59 Motherboard USB Port 226646 bd4EN DEe eeERHEN EEG e DEES he ES BT Re DE aw EG 60 LED IMGICALONS beennaad et 61 BEONE PANG eeens eenen enen 61 Nee KRETA OTTO tikedo eee ewe ee eee eee DE OS OR 63 TECHNICAL SPECIFICATIONS ss es es ss sa RR RR as ak RR ss aas sees OD Dimensions and Weight 0 cee SS ss SS ss eee SS ss SS ss Se ee 65 Power Specifications eee eee eee eee eee ee eee eee ee 65 Environmental Specifications eee eee eee eee 67 Compliance Requirements 0 eee eee ee ee tee eee eee eee 68 Cisco UCS C22 M3 High Density SFF Rack Mount Server OVERVIEW OVERVIEW The Cisco UCS C22 M3 small form factor SFF drive Rack Server combines economics and a density optimized feature set from entry level enterprise to SMB with applications such as scale out virtualization IT and web infrastructure VPN servers file print
56. rocontroller that can securely store artifacts used to authenticate the platform server These artifacts can include passwords certificates or encryption keys A TPM can also be used to store platform measurements that help ensure that the platform remains trustworthy Authentication ensuring that the platform can prove that it is what it claims to be and attestation a process helping to prove that a platform is trustworthy and has not been breached are necessary steps to ensure safer computing in all environments The TPM ordering information is listed in Table 15 Table 15 Trusted Platform Module Product ID PID PID Description UCSX TPM1 001 Trusted Platform Module NOTE The module used in this server conforms to TPM v1 2 1 3 as defined by the Trusted Computing Group TCG It is also SPl based Q Cisco UCS C22 M3 High Density SFF Rack Mount Server 35 CONFIGURING the SERVER 36 STEP 12 ORDER OPTIONAL USB 2 0 DRIVE You may order one optional USB 2 0 drive One socket on the motherboard can accommodate an 8 or 16 GB drive The 8 or 16 GB drive if ordered is blank and comes installed on the motherboard It can be used for a hypervisor or a license dongle The USB drive ordering information is listed in Table 16 Table 16 USB 2 0 Drive Product ID PID PID Description UCS USBFLSHA 8GB 8 GB Flash USB Drive for C22 C24 UCS USBFLSHB 16GB UCS Servers 16GB Flash USB Drive See Figure 6 on page
57. rty software backed by Cisco technical resources and level three support 42 Cisco UCS C22 M3 High Density SFF Rack Mount Server CONFIGURING the SERVER See Table 21 Table 21 Partner Support Service for UCS Product ID PID Service Level GSP On Site Description CON PSJ1 C22M3S CON PSJ2 C22M3S CON PSJ3 C22M3S CON PSJ4 C22M3S PSJ1 PSJ2 PSJ3 PSJ4 No No No No UCS SUPP PSS 8X5XNBD UCS C22 M3 Server SFF UCS SUPP PSS 8X5X4 UCS C22 M3 Server SFF UCS SUPP PSS 24X7X4 UCS C22 M3 Server SFF UCS SUPP PSS 24X7X2 UCS C22 M3 Server SFF Partner Support Service for UCS Hardware Only provides customers with replacement parts in as little as two hours See Table 22 Table 22 Partner Support Service for UCS Hardware Only Product ID PID Service Level GSP O n Site Description CON PSW2 C22M3S CON PSW3 C22M3S CON PSW4 C22M3S PSW2 PSW3 PSW4 No No No UCS W PL PSS 8X5X4 UCS C22 M3 Server SFF UCS W PL PSS 24X7X4 UCS C22 M3 Server SFF UCS W PL PSS 24X7X2 UCS C22 M3 Server SFF Unified Computing Combined Support Service Combined Services makes it easier to purchase and manage required services under one contract SMARTnet services for UCS help increase the availability of your vital data center infrastructure and realize the most value from your unified computing investment The more benefits you realize from the Cisco Unified Computing System Cisco UCS the
58. se common fiber optic cables widely available See the Figure 5 on page 29 for typical SFP and twinax connections to the network cards Caveats Check the table on the following page for compatibility between the PCle network cards and SFPs or twinax cables NOTE The table shows all PCle network cards for all C series servers Not all of the cards shown in the table are supported in this server The intent of the table is to show compatibility between cards and twinax cables or SFPs Cisco UCS C22 M3 High Density SFF Rack Mount Server 27 CONFIGURING the SERVER Table 11 PCle Card Compatibility Twinax Cisco SFP Modules Cables SFP 10G SR DS SFP FC8G SW Converged Network Adapters CNAs UCSC PCIE BSFP Broadcom 57712 Dual Port 10Gb SFP w TOE iSCSI ice le UCSC PCIE CSC 02 Yes Yes No Cisco VIC 1225 Dual Port 10Gb SFP CNA UCSC PCIE C10T 02 No No No Cisco VIC 1225T Dual Port 10GBaseT CNA UCSC PCIE C40Q 02 Cisco VIC 1285 Dual Port 40Gb QSFP CNA UCSC PCIE C40Q 03 Cisco VIC 1385 Dual Port 40Gb QSFP CNA w RDMA UCSC PCIE ESFP Emulex OCe11102 FX dual port 10 GbE FCoE CNA Gen 3 CNA UCSC PCIE QSFP QLogic QLE8242 CU dual port 10 GbE FCoE CNA Use Qlogic SFP UCSC PCIE B3SFP Broadcom 57810 10Gb A FEX SFP UCSC PCIE Q8362 Qlogic QLE8362 dual port 10 GbE FCoE CNA EI Use Qlogic SFP UCSC PCIE E14102 Emulex OCe14102 UX dual port 10 GbE FCoE CNA Network Interface Cards NICs N2XX ABPCIO1 M3
59. servers and appliances Building on the success of the Cisco UCS C Series Servers the Cisco UCS C22 M3 server and the Cisco 1225 VIC further extend the capabilities of the Cisco UCS portfolio in a 1RU form factor with the addition of the Intel Xeon E5 2400 v2 and E5 2400 series processor family CPUs which delivers the best combination of performance and efficiency gains In addition the Cisco UCS C22 M3 server offers 12 DIMM slots up to eight disk drives two PCle slots and two 1 Gigabit Ethernet LAN on motherboard LOM ports that provide both price performance in a compact 1U form factor Figure 1 Cisco UCS C22 M3 High Density SFF Rack Server Front View Cisco UCS C22 M3 High Density SFF Rack Mount Server 3 DETAILED VIEWS DETAILED VIEWS Chassis Front View Figure 2 shows the Cisco UCS C22 M3 High Density SFF Rack Server Figure 2 Chassis Front View nn OE dode TET anno EE 4 a nn mee En IE ae OOO OOO OOO kl C22 M3S 302158 En Power button power status LED 6 Power supply status LED 2 Identification button LED Network link activity LED 3 System status LED 8 USB 2 0 ports two 4 FanstatusLED status LED 9 Patt out asset Pullout asset tag MEET status EE up to eight hot swappable 2 5 inch drives 4 Cisco UCS C22 M3 High Density SFF Rack Mount Server DETAILED VIEWS Chassis Rear View Figure 3 shows the extern
60. tical threshold Undefined AC power supplies are operating and no error condition has been detected One or more power supplies are in a degraded operational state One or more power supplies are in a critical fault state Undefined Link pulses detected on any of the LOM ports but no activity Cisco UCS C22 M3 High Density SFF Rack Mount Server SUPPLEMENTAL MATERIAL Table 31 Front Panel LEDs continued LED LED State Meaning Blinking green Activity on any of the LOM ports Hard Drive Fault Off The hard drive is operating properly On amber The hard drive has failed Blinking amber The hard drive is rebuilding Hard Drive Activity Off There is no hard drive in the hard drive sled no access no fault On green The hard drive is ready Blinking green The hard drive is reading or writing data Rear Panel Figure 13 shows the rear panel LEDs Figure 13 Rear Panel LEDs 285202 Power supply fault LED 10 100 1000 Ethernet dedicated management link status LED Power supply AC OK LED 10 100 1000 Ethernet dedicated management link speed LED 3 1 Gb Ethernet link speed LED Rear Identification button LED Cisco UCS C22 M3 High Density SFF Rack Mount Server 63 SUPPLEMENTAL MATERIAL See Table 32 for the functions of the rear panel LEDs Table 32 Rear Panel LEDs LED Power Supply Fault Power Su
61. upporting up to 8 internal SAS SATA drives SAS and SATA drives can be mixed This option supports RAID 0 1 5 and 10 and operates at 3 Gb s Operating systems supported are Windows and Linux only no VMware support NOTE VMware ESX ESXi or any other virtualized environments are not supported for use with the embedded MegaRAID controller Hypervisors such as Hyper V Xen or KVM are also not supported for use with the embedded MegaRAID controller Table 6 Available Hardware RAID Options Product ID PID PID Description RAID Controllers Note that PCle RAID controllers are installed by default in slot 1 for 1 CPU systems and slot 2 for 2 CPU systems UCSC RAID 9240 aI LSI MegaRAID 9240 8i m Supports up to 8 internal SAS SATA drives SAS and SATA drives can be mixed m RAID levels supported RAID 0 1 5 10 50 see the RAID Configuration Options section later in this table UCSC RAID 9220 al LSI MegaRAID 9220 8i m Supports up to 8 internal SAS SATA drives SAS and SATA drives can be mixed m RAID levels supported RAID 0 1 10 see the RAID Configuration Options section later in this table 18 Cisco UCS C22 M3 High Density SFF Rack Mount Server CONFIGURING the SERVER Table 6 Available Hardware RAID Options continued Product ID PID PID Description UCS RAID9270CV 8i LSI MegaRAID 9270CV 8i with supercap power backup m Supports up to 8 internal SAS SATA drives SAS and SATA drives can be mixed
Download Pdf Manuals
Related Search
Related Contents
Genelec 5040B Active Subwoofer Operating Manual Käyttöohje Digitus USB 3.0 SATA II FUCSINA FENICADA ZIEHL NEELSEN Vincotech ISE User Manual Novedades Tricalc 9.0.10 Bosch 2609256B19 this document - Land Rover Owners Club of Southern Africa User's Guide - Ariadne Software Copyright © All rights reserved.