Home
        Superior Essex 09-097-92
         Contents
1.   09 100 92 50 24  0 51  0 69  18  290  430  5 000  1 524  1 615  735  46 x 25 x 20   09 104 92 100 24  0 51  0 88  22  500  745  5 000  1 524  2 745  1 245  58 x 25 x 20   09 108 92 200 24  0 51  1 18  30  905  1 345  2 500  762  2 510  1 135  58 x 25 x 20   09 110 92 300 24  0 51  1 41  36  1 300  1 935  2 500  762  3 540  1 605  62 x 30 x 24   09 112 92 400 24  0 51  1 59  40  1 680  2 500  2 500  762  4 815  2 185  72 x 35 x 36   09 116 92 600 24  0 51  1 92  49  2 450  3 645  1 250  381  3 350  1 520  62 x 30 x 24  amp   09 118 92 900 24  0 51  2 29  58  3 555  5 290  1 250  381  5 060  2 295  72 x 35 x 36 z  09 120 92 1 200 24  0 51  2 62  67  4 660  6 935  1 250  381  6 525  2 960  78 x 40 x 39 2  09 121 92 1 500 24  0 51  2 91  74  5 755  8 565  1 000  305  6 455  2 930  78 x 40 x 39 o  09 124 92 1 800 24  0 51  3 17  81  6 855  10 200  1 000  305  7 650  3 470  84 x 40 x 42 5  09 125 92 2 100 24  0 51  3 45  88  8 015  11 930  1 000  305  9 190  4 170  96 x 40 x 48    09 126 92 2 400 24  0 51  3 64  93  9 035  13 445  750  229  7 950  3 605  96 x 40 x 48 Q          FREQUENTLY ASKED QUESTIONS    Product FAQs for OSP copper cables are available online   SuperiorEssex com Comm productFAQs aspx       FOR EXTREME RISK ENVIRONMENTS    For extreme direct burial or lashed aerial installations  this cable  is available with the  M feature  See the  Mechanical Protection    M  for Extreme Risk Environments  in the  Technical Info   section for more information        CROWS SUP
2.  5 000  1 524  1 340  610  46 x 25 x 20   09 031 92 25 19  0 90  0 81  21  415  620  5 000  1 524  2 320  1 050  58 x 25 x 20   09 034 92 50 19  0 90  1 07  27  740  1 100  5 000  1 524  4 315  1 955  72 x 35 x 36   09 038 92 100 19  0 90  1 41  36  1 345  2 000  5 000  1 524  7 425  3 370  78 x 40 x 39   09 057 92 6 22  0 64  0 42  11  95  140  5 000  1 524  540  245  36x 18 x 14   09 059 92 12 22  0 64  0 50  13  150  225  5 000  1 524  860  390  44 x 18 x 20   09 062 92 25 22  0 64  0 63  16  245  365  5 000  1 524  1 390  630  46 x 25 x 20   09 065 92 50 22  0 64  0 80  20  410  610  5 000  1 524  2 295  1 040  58 x 25 x 20   09 069 92 100 22  0 64  1 05  27  730  1 085  5 000  1 524  4 265  1 935  72x35x36   09 073 92 200 22  0 64  1 42  36  1 345  2 000  2 500  762  3 650  1 655  62 x 30 x 24   09 075 92 300 22  0 64  1 70  43  1 945  2 895  1 250  381  2 720  1 235  62 x 30 x 24   09 077 92 400 22  0 64  1 92  49  215356 775  1 250  381  3 455  1 570  62 x 30 x 24   09 081 92 600 22  0 64  2 32  59  3 710  5 520  1 250  381  5 250  2 380  72 x 35 x 36   09 083 92 900 22  0 64  2 81  71  5 455  8 120  1 250  381  7 615  3 455  84 x 40 x 42   09 085 92 1 200 22  0 64  3 19  81  7 140  10 625  1 250  381  10 100  4 580  96 x 40 x 48   09 092 92 6 24  0 51  0 39  9 9  80  120  5 000  1 524  465  210  36x 18x14   09 094 92 12 24  0 51  0 45  11  110  165  5 000  1 524  615  280  36x 18 x 14   09 097 92 25 24  0 51  0 55  14  180  270  5 000  1 524  1 065  485  46 x 25 x 20 
3. 52   2        Number of Pairs  12 or less  Over 12    DC Resistance Unbalance  Maximum      Dielectric Strength    Maxi Conduct  E tore DC Potential   Volts    Maximum Average    Minimum Insulation Attenuation  Resistance   68  F  20  C    Conductor Size Resistance   68  F  20  C  772 kHz   68  F  20  C  Ohms sheath Individual Conductor Conductor  AWG  mm  gigohm mile  gigohm km  dB kft  dB km  mile  km  Average Pair to Conductor to Shield  19  0 90  1 0  1 6  3 2  10 5  45 0  28 0  w5 5 0 4 500 10 000  22  0 64  1 0  1 6  4 5  14 8  91 0  56 5  1 5 5 0 3 600 10 000  24  0 51  1 0  1 6  5 6  18 4  144 0  89 5  15 50 3 000 10 000     For cables with 12 pair or less  the maximum average attenuation may be increased by 10  over the values shown     Minimum Near End Crosstalk  NEXT       772 kHz  PSWUNEXT Mean  dB  47  PSWUNEXT Worst Pair  dB  42    Minimum Far End Crosstalk  FEXT       772 kHz  Conductor Size  AWG  Ag 22 24  PSELFEXT Mean  dB kft  51 49 49  PSELFEXT Worst Pair  dB kft  45 43 43    SUPERIOR  F  1 2 A ESSEX Rev 1 12 Ed 11 0    Toll Free 800 551 8948   Fax 770 657 6807   SuperiorEssex com Comm    CASPIC   FSF RDUP PE 89    PART NUMBERS AND PHYSICAL CHARACTERISTICS                Approx  Reel Size  Nominal Diameter Approx  Weight Standard Length Shipping Weight FxTxD   Part Number Pair Count AWG  mm  in  mm  Ibs kft  kg km  ft  m  Ibs  kg  in   09 026 92 6 19  0 90  0152  13  155  230  5 000  1 524  885  400  44 x 18 x 20   09 028 92 12 19  0 90  0 62  16  235  350 
4. CASPIC      RDUP PE 89     FSF    i       tt Hi HNN       SPECIFICATIONS    PRODUCT DESCRIPTION  CASPIC   FSF Cables are designed for direct burial applications   CASPIC FSF cables are recommended for use in high risk areas where  additional mechanical or rodent protection is required  CASPIC FSF may  be used aerially  but must be attached to a support strand     APPLICATIONS    Direct burial where additional mechanical protection    Conductor Solid Annealed Copper is requried or desired  Dual insulation consisting of an inner layer of foamed  natural   Lashed aerial where additional mechanical protection  Insulation polyolefin over which is applied a solid  skin  layer of is requried or desired    Twisted Pairs     lt  25 Pair Core     gt  25 Pair Core    Filling Compound    polyolefin colored in accordance wi    h industry standards    Individual insulated conductors  twisted into pairs with    varying lay lengths  specific color  pair identification    Pairs are assembled into a cylindrica    Cables larger than 25 pair are assem  which are then used to assemble  are identifiable using color coded    80  C ETPR compound  completely fi    combinations provide    core    bled into units   he core  units  binders    ling the interstices    between the pairs and under the core wrap       FEATURES    Twisted into pairs with varying  lay lengths    Core wrap  Filled core  Dual shield design    Fully flooded shield interfaces    BENEFITS    Minimizes crosstalk    Provides thermal 
5. ERIOR 13    Rev 1 12 Ed 11 0 Toll Free 800 551 8948   Fax 770 657 6807   SuperiorEssex com Comm ESSEX     
6. protection  Moisture resistant  Rodent resistant    Inhibits corrosion  and water migration    Core Wrap Non hygroscopic  dielectric tape applied over the core   Black  polyethylene jacket   Provides a tough  protective  Corrugated  copolymer coated  8 mil aluminum tape covering designed to withstand  mesrak applied directly over the core wrap  does not butt exposure to direct sunlight   or overlap at any point along the length of the cable  atmospheric temperature  flooded shield interfi  EEEE changes and stresses expected  Rodent resistant  corrugated  copolymer coated  6 mil in standard installations  Outer Shield steel tape applied directly over the aluminum and  overlaps  flooded shield interface  Jacket Black  polyethylene  Identifying information includes a telephone handset   Jacket Marking cable code  pair count  AWG  date of manufacture       and sequential length markings at 2 foot intervals    ANSI ICEA S 84 608 2007  RDUP 7 CFR 1755 890  PE 89   RoHS compliant    ELECTRICAL SPECIFICATIONS    Capacitance Unbalance Capacitance Unbalance  Pair to Pair   1 kHz Pair to Ground   1 kHz    Maximum Individual Maximum RMS Maximum Individual Maximum Average  pF   1kft  pF   1km  pF   1kft  pF   1km  pF  1kft  pF   1km  pF  1 kft  pF   1km     80  145    800  2 625     80  145  25  45  800  2 625  175  574     Standards Compliance    D  o      3  Zz      n   e   an  v   a    e   d  fz   m  a    Average Mutual  Capacitance   1000 Hz  nF mile  nF km     83  7  52  4   83   4  
    