Home

Tripp Lite SmartPro 230V 3kVA 2.7kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, LCD, USB, DB9 Serial

image

Contents

1. High Voltage Transfer to Battery 278 Power Setpoint SPECIAL FEATURES Cold Start Startup in Battery Mode g During a Power Failure Cold start operation supported High Availability UPS Features Hot swappable batteries Greater than 95 efficiency GREEN UPS Individually controllable load banks Schedulable daily hours of economy mode operation CERTIFICATIONS UPS Certifications CE ROHS Restriction of Hazardous Substances UPS Certification Details IEC 62040 1 IEC 62040 2 Class A EMI GOST WARRANTY Product Warranty Period Worldwide 2 year limited warranty 2015 Tripp Lite All rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of continuous improvement Green Energy Saving Features Specifications are subject to change without notice Photos may differ slightly from final products 9 95
2. detailed e PowerAlert Software with USB UPS and site power data plus enables a variety of UPS setup and configuration options Super fast switchover Serial amp EPO cabling from line to battery power occurs within milliseconds to maintain operation of connected equipment without e 4 post rackmount installation kit interruption or reboot 98 line mode efficiency offers reduced heat emissions and operating costs Network e Set of 3 C13 C14 power cables management interfaces support communications via USB RS 232 and optional SNMPWEBCARD network e Instruction manual interface HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X Network communications ports enable detailed monitoring of equipment load levels self test data and utility power conditions Includes PowerAlert monitoring software and complete cabling Switched output load banks enable scheduled and real time remote reboot and load shedding of select outlets Emergency Power Off EPO interface LCD display panel easily rotates for viewing in rackmount or tower configurations Audible alarm with push button momentary alarm cancel and silent mode configuration options Programmable self test Field replaceable hot swappable battery modules Features e Tripp Lite SMX3000XLRT2UA line interactive 2U rack tower UPS with 3000VA 3kVA capacity and extended runtime options e Line interactive UPS with Automatic Voltage
3. Regulation AVR corrects brownouts and overvoltages from 158 to 278V e C20 AC power inlet 8 C13 and 1 C19 output receptacles Two independently switchable output load banks e Maintains uninterrupted operation of connected networking equipment during blackouts surges brownouts and overvoltages e High 98 efficiency rating in line power mode offers reduced power consumption and BTU emisssions e Internal batteries offer 11 1 minutes at 50 load 1350W and 3 9 minutes at 100 load 2700W 1 5 Tripp Lite ERRON 35th Street amp Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Extended runtime is available with optional external battery packs BP48V24 2U limit 1 BP48V60RT 3U multi pack compatible and BP48V27 2US multi pack compatible External battery configurations require the use of Tripp Lite s External Battery Configuration Software see manual Hot swappable user replaceable internal batteries and external battery packs can be replaced with no disruption to connected equipment Front panel LCD monitoring screen with MODE and ENTER buttons reports operating mode with 5 bar battery charge graphic plus 7 selectable screens of detailed UPS and site power information LCD interface also supports a number of advanced user setup and operating preferences Ships with 4 post rackmount installation hardware Optional 2POSTRMKITWM enables 2 post rackmount wallmount installation Optional 2 9USTAND enables tower pla
4. Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com SmartPro 230V 3kVA 2 7kW Line Interactive Sine Highlights Wave UPS Extended Run SNMP Webcard 2U eee out pe Rack Tower LCD USB DBO Serial interactive 2U rack tower UPS Sine Wave MODEL NUMBER SMX3000XLRT2UA e 230V output Corrects brownouts and overvoltages from 158V to 278V e 0 9 Power Factor Interactive LCD interface e Extended runtime options up to 2700W e 4 post compatible mounting accessories e 98 line mode efficiency 2 switched load banks e USB RS232 EPO and slot for SNMPWEBCARD option e 230V C20 inlet 8 C13 amp 1 C19 outlets Description Applications Tripp Lite SmartPro Line Interactive UPS with enhanced LCD interface offers network grade power protection for Ideal for server networking and critical server network and telecommunications equipment Line Interactive Uninterruptible Power Supply UPS Ao ee telecommunications equipment with built in Auto Voltage Regulation AVR actively corrects brownouts and overvoltages back to usable levels while maintaining a full battery charge in case of power failure Tripp Lite s unique configuration excels in Package Includes exceptionally poor power environments with two separate levels of voltage boost to correct both slight e SMX3000XLRT2UA UPS system undervoltages and severe brownout conditions Interactive LCD interface reports UPS operating mode
5. cement Built in USB RS 232 and optional SNMPWEBCARD accessory monitoring options HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X Included PowerAlert UPS monitoring software Built in Emergency Power Off EPO interface with cable Specifications OUTPUT Output Volt Amp Capacity VA 3000 Output kVA Capacity kVA Output Watt Capacity Watts 2700 NO wo N Output kW Capacity kW Power Factor Nominal Output Voltage s 220V 230V 240V Supported i Nominal Voltage Details 230v nominal inverter output voltage Frequency Compatibility 50 60 Hz Output Voltage Regulation Line 46 15 Mode Output Voltage Regulation Battery Mode Output Receptacles 8 C13 1 C19 Included Output Power Cables Set of 3 C13 to C14 power cables included Load Management Receptacles Two switchable single outlet C13 load banks Output AC Waveform AC Mode Pure Sine wave 5 Output AC Waveform Battery Mode Pure Sine wave INPUT Rated input current Maximum Load 14 1A Nominal Input Voltage s Supported 230V AC UPS Input Connection Type C20 inlet 2 9 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Input Circuit Breakers Input Phase Single Phase BATTERY Full Load Runtime min 3 9 min 2700w Half Load Runtime min 11 1 min 1350w Expandable Battery Runtime Ex
6. ditions SURGE NOISE SUPPRESSION EMI RFI AC Noise Suppression PHYSICAL Tripp Lite ieee YY 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Included Mounting Accessory eee 4 post rackmount installation hardware included Description Installation Form Factors Supported i l 2 post rackmount 2POSTRMKITWM Wallmount POSTRMKITWM Tower 2 9USTAND with Optional Accessories Primary Form Factor Rackmount UPS Power Module Dimensions hwd in 30 17 0 xX 19 5 ae Module Dimensions 89x44 4x495 Rack Height U Spaces UPS Power Module Weight Ibs 62 8 UPS Power Module Weight kg 28 5 UPS Shipping Dimensions hwd in 9 x 23 75 x 20 5 UPS Shipping Dimensions hwd 22 9 x 60 3 x 52 1 Shipping Weight Ibs Shipping Weight kg Cooling Method UPS Housing Material Steel O alol N o w N oO ENVIRONMENTAL Operating Temperature Range 32 to 104 degrees Fahrenheit 0 to 40 degrees Celsius Storage Temperature Range 5 to 122 degrees Fahrenheit 15 to 50 degrees Celsius Relative Humidity 158 AC Mode Efficiency Rating 100 0 98 Load COMMUNICATIONS LINE BATTERY TRANSFER 6 milliseconds AC to battery mode 1 millisecond Battery to AC mode Low Voltage Transfer to Battery 158 Power Setpoint 0 to 95 non condensing 4 5 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com
7. tended runtime supported via optional external battery packs External Battery Pack Compatibility BP48V24 2U limit 1 BP48V60RT 3U multi pack compatible BP48V27 2US multi pack compatible UPS Input Connection Description IEC320 C20 input connection accepts a variety of user supplied detachable C19 output cordsets to match country or site specific power sources DC System Voltage VDC Battery Recharge Rate Included Less than 5 hours from 10 to 90 typical full load discharge Batteries Internal UPS Replacement Battery RBC58 2U Cartridge Battery Access Front panel battery access door Battery Replacement Description Hot swappable replaceable batteries VOLTAGE REGULATION USER INTERFACE ALERTS amp CONTROLS Front panel LCD information and configuration screen offers detailed UPS and site power status and operating Front Panel LCD Display data plus configuration of voltage operating mode alarm function and a variety of additional options see manual for detailed LCD configuration and monitoring options 3 pushbutton switches control OFF ON power status MODE selection and MUTE ENTER control functions fai ily si i m cancel switch silent m larm configuration option Alarm Cancel Operation Aeara miod alarm can be temporarily silenced using alarm cancel switch silent mode alarm configuration optio Audible Alarm Audible alarm indicates UPS startup power failure low battery overload UPS fault and remote shutdown con