Home

MEAN WELL LPF-60D-24 power supply unit

image

Contents

1. max a a oe S 1 Hiccup a Protection 4 50 95 lo Typical LED power supply l V curve File Name LPF 60D SPEC 2014 01 15 60W Single Output Switching Power Supply L P P 6 0 D series E DIMMING OPERATION N oY AC N Blue AC L Brown V Red V Black DIA BN e DIM White DC ouT LPF 60D X Built in 3 in 1 dimming function output constant current level can be adjusted through output cable by 1 10Vdc 10V PWM signal or resistance between DIM and DIM X Please DO NOT connect DIM to V gt lt Reference resistance value for output current adjustment Typical Single driver 10KQ 20KQ 30KQ 40KQ 50KQ 60KQ 70KQ 80KQ 9OKQ 100KQ OPEN Resistance Multiple drivers value KUTIA AAGA 10K Q N 20K 0 N 30K 2 N140K Q N 50K Q N 160K Q N 70K Q N 80KQ N 90KQ N 100KQ N dimming operation Percentage of rated current 10 20 30 40 50 60 70 80 90 100 95 108 X 1 10V dimming function for output current adjustment Typical Dimming value 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V OPEN Output current 10 20 30 40 50 60 70 80 90 100 95 108 X 10V PWM signal for output current adjustment Typical Frequency range 100Hz 3KHz Duty value 10 20 30 40 50 60 70 80 90 100 OPEN Output current 10 20
2. 30 40 50 60 70 80 90 100 95 108 gt lt Using the built in dimming function on LPF 60D can t turn the lighting fixture totally dark Please refer to the connection method below to achieve 0 brightness of the lighting fixture connecting to the LED power supply unit Dimming connection diagram for turning the lighting fixture ON OFF N L Relay Switch Adjuster E N j 10K 100K Ohms resistance 1 10V DC Voltage i 10V PWM Signal DIM Blue AC L DIM White Brown LPF 60D v o Black Blue o ACIN vit Red LED Lighting Fixture Using a switch and relay can turn ON OFF the lighting fixture 1 Output constant current level can be adjusted through output cable by connecting a resistor or 1 10Vdc or 10V PWM signal between DIM and DIM 2 The LED lighting fixture can be turned ON OFF by the switch File Name LPF 60D SPEC 2014 01 15
3. 40 80 C 10 95 RH TEMP COEFFICIENT 0 03 C 0 50 C VIBRATION 10 500Hz 5G 12min 1cycle period for 72min each along X Y Z axes UL8750 CSA C22 2 No 250 0 08 except for 48V 54V EN61347 1 EN61347 2 13 independent IP67 J61347 1 J61347 2 13 approved design refer to UL60950 1 TUV EN60950 1 SAFETY amp WITHSTAND VOLTAGE I P O P 3 75KVAC EMC ISOLATION RESISTANCE P O P 100M Ohms 500VDC 25 C 70 RH EMC EMISSION Compliance to EN55015 EN61000 3 2 Class C 260 load EN61000 3 3 EMC IMMUNITY Compliance to EN61000 4 2 3 4 5 6 8 11 EN61547 EN55024 light industry level surge 2KV criteriaA MTBF 396 7K hrs min MIL HDBK 217F 25 C OTHERS DIMENSION 162 5 43 32mm L W H PACKING 0 45Kg 32pces 15 4Kg 0 93CUFT All parameters NOT specially mentioned are measured at 230VAC input rated load and 25 C of ambient temperature Ripple amp noise are measured at 20MHz of bandwidth by using a 12 twisted pair wire terminated with a 0 1uf amp 47uf parallel capacitor Tolerance includes set up tolerance line regulation and load regulation Please refer to DRIVING METHODS OF LED MODULE Derating may be needed under low input voltages Please check the static characteristics for more details Suitable for indoor use or outdoor use without direct sunlight exposure Please avoid immerse in the water over 30 minutes Length of set up time is measured at cold first start Turning ON OFF the power supply may le
4. Characteristics 100 4 100 4 90 F 4 80 J 230VAC 80 d Input only 60 F J 70 J 50 FA S S 60H J 40 4 lt Q sob 3 20 J S ao J ji 1 L 1 1 1 L L j iji L i i L i i 40 30 0 15 30 40 50 60 70 HORIZONTAL 90 100 125 135 145 155 165 175 180 200 230 305 AMBIENT TEMPERATURE C INPUT VOLTAGE V 60Hz File Name LPF 60D SPEC 2014 01 15 60W Single Output Switching Power Supply L P P 6 0 D series E Power Factor Characteristic Constant Current Mode 99 98 a ee aa a EE 93 A M0 m2 77VAC eee 1 15 VAC 92 91 0 9 89 8 8 87 86 85 84 50 60 70 80 90 100 60W PF D O 6 6s 6 OG O 6 6 ecooooond LOAD E EFFICIENCY vs LOAD 48V Model LPF 60D series possess superior working efficiency that up to 90 can be reached in field applications 93 92 sa 90 a ne wa STA S oe gt 87 S CAO Z me Ia NZ 4 277VAC 2 a YL XNK E 230VAC m 83 A f 115VAC 32 81 A 80 7 79 78 10 20 30 40 50 60 70 80 90 100 LOAD E DRIVING METHODS OF LED MODULE This LED power supply is suggested to work in constant current mode area CC to drive the LEDs yy In the constant current region the highest voltage at the output of the driver 100 3 _ _ depends on the configuration of the end systems Should there be any compatibility issues please contact MEAN WELL Constant gs Current area 60
5. 60W Single Output Switching Power Supply L P F 6 0 D series E Features e Universal AC input Full range up to 305VAC e Built in active PFC function e High efficiency up to 90 e Protections Short circuit Over current Over voltage Over temperature Cooling by free air convection Fully isolated plastic case Fully encapsulated with IP67 level Note 6 e Class II power unit no FG e Class 2 power unit e Built in 3 in 1 dimming function 1 10Vdc or PWM signal or resistance Suitable for LED lighting and moving sign applications Compliance to worldwide safety regulations for lighting ie e Suitable for dry damp wet locations TAIWAN e 5 years warranty EXCELLENCE 2012 E O WW NYA SELV IP67 amp AL for 48V 54V only cA US except for 48v 54v SPECIFICATION 412 CBCE MODEL LPF 60D 12 LPF 60D 15 LPF 60D 20 LPF 60D 24 LPF 60D 30 LPF 60D 36 LPF 60D 42 LPF 60D 48 LPF 60D 54 DC VOLTAGE 12V 15V 20V 24V 30V 36V 42V 48V 54V CONSTANT CURRENT REGION Note 4 7 2 12V 9 15V 12 20V 14 4 24V 18 30V 21 6 36V 25 2 42V 28 8 48V 32 4 54V RATED CURRENT 5A 4A 3A 2 5A 2A 1 67A 1 43A 1 25A 1 12A RATED POWER 60W 60W 60W 60W 60W 60 12W 60 06W 60W 60 48W OUTPUT RIPPLE amp NOISE max Note 2 150mVp p 150mVp
6. ad to increase of the set up time The power supply is considered as a component that will be operated in combination with final equipment Since EMC performance will be affected by the complete installation the final equipment manufacturers must re qualify EMC Directive on the complete installation again Direct connecting to LEDs is suggested but is not suitable for using additional drivers SAFETY STANDARDS Note 6 NOTE SONOARWHY gt o File Name LPF 60D SPEC 2014 01 15 MW MEAN WELL 60W Single Output Switching Power Supply LP F 60 D series ui SS ii iii ao a ary E Mechanical Specification Case No LPF 60B Unit mm 162 5 300 20 30020 ACIN Blue Ti o V Red AC L Brown cl R V Black SJTW 18AWG X2C X DIM Blue L UL2464 18AWG X 2C V V DIM White 113 5 UL2464 22AWG X 2C DIM DIM X T case Max Case Temperature E Recommend Mounting Direction E Block Diagram Fosc 100KHz EMI FILTER PEC POWER B RECTIFIERS N I P 0 amp SWITCHING amp RECTIFIERS CIRCUIT 3 PTER eo V O LP i F DETECTION x st OLP PWM8PFC ex CIRCUIT CONTROL ex 0 V P E Derating Curve E Static
7. p 150mVp p 150mVp p 200mVp p 250mVp p 250mVp p 250mVp p 350mVp p VOLTAGE TOLERANCE Note 3 4 0 4 0 4 0 4 0 4 0 4 0 4 0 4 0 4 0 LINE REGULATION 0 5 0 5 0 5 0 5 0 5 0 5 0 5 0 5 0 5 LOAD REGULATION 2 0 1 5 1 0 0 5 0 5 0 5 0 5 0 5 0 5 SETUP RISE TIME Note 7 1000ms 80ms 115VAC at full load 1000ms 80ms 230VAC HOLD UP TIME Typ 16ms 230VAC 16ms 115VAC at full load VOLTAGE RANGE Note 5 90 305VAC 127 431VDC FREQUENCY RANGE 47 63Hz POWER FACTOR Typ PF gt 0 97 115VAC PF gt 0 95 230VAC PF gt 0 92 277VAC at full load Please refer to Power Factor Characteristic curve INPUT EFFICIENCY Typ 86 87 88 89 90 90 90 90 90 AC CURRENT Typ 0 8A 115VAC 0 4A 230VAC 0 32A 277VAC INRUSH CURRENT Typ COLD START 55A twidth 270 s measured at 50 Ipeak at 230VAC LEAKAGE CURRENT lt 0 75mA 240VAC OVERCURRENT note4 29 108 Protection type Constant current limiting recovers automatically after fault condition is removed PROTECTION SHORT CIRCUIT Hiccup mode recovers automatically after fault condition is removed 15 17V 17 5 21V 23 27V 28 35V 34 40V 41 49V 46 54V 54 63V 59 66V OVERVOLTAGE Protection type Shut down and latch off o p voltage re power on to recover OVER TEMPERATURE Shut down o p voltage re power on to recover WORKING TEMP 40 70 C Refer to Derating Curve WORKING HUMIDITY 20 95 RH non condensing ENVIRONMENT STORAGE TEMP HUMIDITY