Home

Bosch ISM-BLA1-LM motion detector

image

Contents

1. module mounts on top of a Blue Line detector by removing the detector from its mounting base installing the module on the detector base and reattaching the detector and the module lens Ensure there is enough space above the detector for the nightlight module Wiring Considerations The three module wires attach to the terminal block of the Blue Line detector Americas Europe Middle East Africa Asia Pacific Parts Included Quant Component 1 Nightlight module 1 Test filter 1 Literature pack Technical Specifications Environmental Considerations Complies with EN50131 Environmental Class II Security Grade 2 Relative Humidity Up to 95 non condensing Up to 85 for UL installations 10 C to 49 C 14 F to 120 F For UL Listed product installations O C to 49 C 32 F to 120 F Temperature operating Mechanical Properties Color White 2 5 cm x 6 4 cm x 3 2 cm 1 0in X2 5in X 1 25 in High impact ABS plastic Dimensions Material Output Light Intensity 0 1 cd at 30 cm 1 ft Power Requirements Current Draw LEDs lit Standby Power Brightness level set low 40 mA Brightness level set high 75 mA No internal standby battery Standby power must be provided by the control unit or by a UL Listed bur glary power supply Ordering Information ISM BLA1 LM Blue Line Nightlight Module Fits all Blue Line detectors ISM BLA1 LM Represented by Robert Bosch SEA Pte Lt
2. Intrusion Systems ISM BLA1 LM Blue Line Nightlight Module BOSCH Invented for life ISM BLA1 LM Blue Line Nightlight Module The Blue Line ISM BLA1 LM Nightlight Module attaches to the Blue Line detectors When the detector senses a presence the module s LEDs light and provide illumination up to the equivalent of bright moonlight 0 1 cd at 30 cm 1 ft from the detector Functions Unique Interface The Blue Line Nightlight Module mounts on top of and is wired to a Blue Line detector This unique interface between module and detector makes installation fast easy and inexpensive Once the detector is mounted and wired to the control panel you simply add the module with no additional wiring needed Basic Operation The nightlight module has a photo sensor and four LEDs under a diffusing lens It mounts on draws its power from and is controlled by any Blue Line detector Once installed and set if the detector senses motion and the photo sensor does not detect light the LEDs light Settings Brightness The brightness level can be set for low or high by positioning a jumper during module installation Duration gt Modular construction fits all Blue Line detectors gt High quality affordable and easy to install gt Exterior switches control light duration short or long and on or off gt Two installer selectable brightness levels gt Aesthetic design The length of time the LEDs remain lit is s
3. d Security Systems 11 Bishan Street 21 Singapore 573943 Phone 65 6258 5511 Fax 65 6571 2698 apr securitysystems bosch com www boschsecurity com Bosch Security Systems Inc Bosch Security Systems B V 130 Perinton Parkway P O Box 80002 Fairport New York 14450 USA 5600 JB Eindhoven The Netherlands Phone 1 800 289 0096 Phone 31 40 2577 284 Fax 1 585 223 9180 Fax 31 40 2577 330 security sales us bosch com emea securitysystems bosch com www boschsecurity us www boschsecurity com Bosch Security Systems Inc 2010 Data subject to change without notice 71642545163 Cur en US V12 2 Dec 2010
4. et with an external switch on the side of the module Short duration is approximately 20 sec to 30 sec while long duration is approximately 2 min to 4 min On Off Use the external On or Off switch on the side of the module to determine if the LEDs light when motion is detected Field Testing The module comes with a piece of black plastic for covering the photo sensor for field testing the module www boschsecurity com 2 ISM BLA1 LM Blue Line Nightlight Module Certifications and Approvals Region Certification 89 336 EEC EN50130 4 1996 A1 1998 A2 2003 EN61000 4 2 1995 A1 1998 A2 2001 EN61000 4 3 2002 A1 2002 A2 2005 EN61000 4 4 1995 A1 2000 A2 2001 EN61000 4 5 1995 A1 2001 EN61000 4 6 1996 A1 2001 A2 2001 A3 2005 EN61000 4 11 1994 A1 2001 GOST 12997 84 GOST R 50009 2000 GOST R 51317 3 2 99 GOST R 51317 3 3 99 GOST R MEK 60065 2002 ANSR Intrusion Detection Units UL639 ANSR7 Intrusion Detection Units Certified for Canada cULus Europe CE Russia GOST USA UL Belgium INCERT B 509 0009 a Installation Configuration Notes Compatibility Information The BLA1 LM Nightlight Module is compatible with the following products Detectors BLD1 Blue Line TriTech Detectors BLD1 P Blue Line Pet Friendly TriTech Detectors BLP1 Blue Line PIR Detector BLP1 P Blue Line Pet Friendly PIR Detector BLQ1 Blue Line quad PIR Detector Mounting Considerations The nightlight

Download Pdf Manuals

image

Related Search

Related Contents

Eureka! Tents AS1000 User's Manual  Manuale dell`utente  Audiovox APS997E Installation Manual  FM3101 user manual 1.3  Rapoo E9180P  1月 - 本巣市  Samsung CLX-3170FN Manual de Usuario  Sandberg Cover iPad Mini Soft White  Liste des ouvrages CRD Ajaccio Décembre 2012  SOARIAN Manuals  

Copyright © All rights reserved.
Failed to retrieve file