MEAN WELL SP-75-24
Contents
1. MEAN WELL E Mechanical Specification CaseNo 920A Unit mm 60 65 ra x E ses PA LE LT BEEN NAN ANNONA AANAANAAN ANA ADJ h wD o UU UULUUUUULUU UUUU of q 31 Ke 4 o 12 eo 2 ep ee o nnannonnnnnnnondMiEm e di 34 f f N q 45 Terminal Pin No Assignment foU UI mum TUA Pin No Assignment Pin No Assignment pe 1 DC OUTPUT V 4 ACIN eee ris 2 DC OUTPUT V 5 ACIL 3 FG 11 max m of Remote ON OFF CN3 Molex 5046 02 or equivalent optional 5 o ol z 2 Pin No Assignment Mating Housing Terminal AL LAL m 1 RC Molex 5051 Molex 2759 o LL Q 2 RC or equivalent or equivalent 25 117 6 M4 L 6mm 179 E Block Diagram g PFC fosc 67KHz PWM fosc 134KHz P o M PFC POWER REST ASRS t TOV RECTIFIERS CIRCUIT SWITCHING FILTER T BOE t CONSTANT ae CURRENT dz LIMITING amp FG 0 4 15 9 s av Hec DETECTION CIRCUIT CONTROL MEN A O V P li Derating Curve E Output Derating VS Input Voltage Ta 25 C For 3 3V 5V 7 5V type With 18CFM Forced AIR 80 1 80 1 For 12V output or above ar gt 40 4 mur x Q 50 E 9 o 4 20 J 3 aL L L i fi L 1 fi I 1 fi R ii 10 0 10 20 30 40 50 60 70 HORIZONTAL 85 100 m 135 155 230 264 AMBIENT TEMPERATURE C INPUT VOLTAGE VAC 60Hz File Name SP 75N SPEC
2. 2012 08 29
3. ENV50204 EN55024 light industry level criteria A MTBF 208 8K hrs min MIL HDBK 217F 25 C OTHERS DIMENSION 179 97 33mm L W H PACKING 0 58Kg 20pcs 12Kg 0 64CUFT 1 All parameters NOT specially mentioned are measured at 230VAC input rated load and 25 C of ambient temperature 2 Ripple amp noise are measured at 20MHz of bandwidth by using a 12 twisted pair wire terminated with a 0 1uf amp 47uf parallel capacitor 3 Tolerance includes set up tolerance line regulation and load regulation NOTE 4 The power supply is considered a component which will be installed into a final equipment The final equipment must be re confirmed that it still meets EMC directives For guidance on how to perform these EMC tests please refer to EMI testing of component power supplies as available on http www meanwell com 5 Derating may be needed under low input voltages Please check the derating curve for more details File Name SP 75N SPEC 2012 08 29 MW SP 75 75W Single Output with PFC Function
4. MW SP 75 75W Single Output with PFC Function E Features Universal AC input Full range Built in active PFC function PF gt 0 93 EA Protections Short circuit Overload Over voltage Built in constant current limiting circuit Low profile 33mm thickness LED indicator for power on 100 full load burn in test Fixed switching frequency at PFC 67KHz PWM 134KHz 3 years warranty PO Al 42 CBC SPECIFICATION MODEL SP 75 3 3 SP 75 5 SP 75 7 5 SP 75 12 SP 75 13 5 SP 75 15 SP 75 24 SP 75 27 SP 75 48 DC VOLTAGE 3 3V 5V 7 5V 12V 13 5V 15V 24V 27V 48V RATED CURRENT 15A 15A 10A 6 3A 5 6A 5A 3 2A 2 8A 1 6A CURRENT RANGE 0 15A 0 15A 0 10A 0 6 3A 0 5 6A 0 5A 0 3 2A 0 2 8A 0 1 6A RATED POWER 49 5W 75W 75W 75 6W 75 6W 75W 76 8W 75 6W 76 8W RIPPLE amp NOISE max Note 2 80mVp p 80mVp p 80mVp p 80mVp p 80mVp p 80mVp p 100mVp p 100mVp p 100mVp p OUTPUT VOLTAGE ADJ RANGE 3 14 3 63V 4 75 5 5V 7 13 8 25V 11 4 13 2V 12 8 14 9V 14 3 16 5V 22 8 26 4V 25 7 29 7V 45 6 52 8V VOLTAGE TOLERANCE Note 3 2 0 2 0 2 0 2 0 2 0 2 0 1 0 1 0 1 0 LINE REGULATION 0 5 0 5 0 5 0 5 0 5 0 5 0 5 0 5 0 5 LOAD REGULATION 1 0 1 0 1 0 0 5 0 5 0 5 0 5 0 5 0 5 SETUP RISE TIME 800ms 60ms at full load HOLD UP TIME Typ 36ms at
5. full load VOLTAGE RANGE Note 5 85 264VAC 120 370VDC FREQUENCY RANGE 47 63Hz POWER FACTOR Typ PF gt 0 93 230VAC 0 96 115VAC at full load INPUT EFFICIENCY Typ 70 76 79 81 82 82 83 83 83 AC CURRENT Typ 1 3A 115VAC 0 7A 230VAC INRUSH CURRENT Typ COLD START 45A 230VAC LEAKAGE CURRENT lt 2mA 240VAC 105 150 rated output power OVERLOAD p mA SEES PROTECTION Protection type Constant current limiting recovers automatically after fault condition is removed 3 8 4 46V 5 75 6 75V 8 63 10 13V 13 8 16 2V 15 53 18 23V 17 25 20 25V 27 6 32 4V 31 05 36 45V 55 2 64 8V OVER VOLTAGE Protection type Shut down o p voltage re power on to recover FUNCTION REMOTE CONTROL OPTION CN3 4 10VDC POWER OFF 0 0 8VDC POWER ON WORKING TEMP 10 60 C Refer to output load derating curve WORKING HUMIDITY 20 90 RH non condensing ENVIRONMENT STORAGE TEMP HUMIDITY 20 85 C 10 95 RH TEMP COEFFICIENT 0 05 C 0 50 C VIBRATION 10 500Hz 2G 10min 1cycle 60min each along X Y Z axes SAFETY STANDARDS UL60950 1 TUV EN60950 1 approved WITHSTAND VOLTAGE lP O P 3KVAC I P FG 2KVAC O P FG 0 5KVAC SAFETY amp ISOLATION RESISTANCE l P O P lIP FG O P FG 100M Ohms 500VDC 25 C 70 RH fis 4 EMC EMISSION Compliance to EN55022 CISPR22 Class B EN61000 3 2 3 EMC IMMUNITY Compliance to EN61000 4 2 3 4 5 6 8 11
Download Pdf Manuals
Related Search
Related Contents
GiiNii GN-711W User's Manual Fluke FLUKE-125/003 Datasheet ノマドスーツケース取扱説明書 ver. 4-2011-07-11 1 Fluorometer Function and Description Unpacking KOHLER K-700-NY Installation Guide Quaternäre Pumpe der Agilent Serie 1200 Manuel Anglais Un héritage sans testament. Patrimoine et générations futures 1 - パイオニア Copyright © All rights reserved.