Cisco Intel E5-2609v2 4C 2.5GHz
Contents
1. Cisco UCS B200 M3 Blade Server 19 CONFIGURING the SERVER STEP 5 CHOOSE ADAPTERS The adapter offerings are m Cisco Virtual Interface Cards VICs Cisco developed Virtual Interface Cards VICs to provide flexibility to create multiple NIC and HBA devices The VICs also support adapter Fabric Extender and Virtual Machine Fabric Extender technologies m Converged Network Adapters CNAs Emulex and QLogic Converged Network Adapters CNAs consolidate Ethernet and Storage FC traffic on the Unified Fabric by supporting FCoE m Cisco UCS Storage Accelerator Adapters Cisco UCS Storage Accelerator adapters are designed specifically for the Cisco UCS B series M3 blade servers and integrate seamlessly to allow improvement in performance and relief of I O bottlenecks Q NOTE There are two slots on the server One accommodates Cisco Emulex and QLogic I O adapters or Cisco Storage Accelerator adapters as well as other options and one is a dedicated slot for the VIC 1240 adapter only Table 9 shows which adapters plug into each of the two slots Only the VIC 1240 adapter plugs into the VIC 1240 adapter slot All other adapters plug into the mezzanine adapter slot NOTE You must have a B200 M3 configured with 2 CPUs to support cards that plug Ca into the mezzanine connector The VIC 1240 adapter is supported on both 1 and 2 CPU configured systems Choose a Mezzanine Adapter The supported mezzanine adapters
2. m Optimize the uptime performance and efficiency of your UCS m Protect your vital business applications by rapidly identifying and addressing issues m Strengthen in house expertise through knowledge transfer and mentoring a Improve operational efficiency by allowing UCS experts to augment your internal staff resources Enhance business agility by diagnosing potential issues before they affect your operations 32 Cisco UCS B200 M3 Blade Server CONFIGURING the SERVER You can choose a service listed in Table 21 Table 21 UCS Computing Combined Support Service Service On Product ID PID Level 3 Description Site GSP CON NCF2 B200M3 NCP2 No CMB SPT SVC 24X7X2 UCS B200 M3 Blade Server CON NCF2P B200M3 NCF2P Yes CMB SPT SVC 24X7X20S UCS B200 M3 Blade Server CON NCF4P B200M3 NCF4P Yes CMB SPT SVC 24X7X40S UCS B200 M3 Blade Server CON NCF4SB200M3 NCF4S Yes CMB SPT SVC 8X5X40S UCS B200 M3 Blade Server CON NCFCSB200M3 NCFCS Yes CMB SPT SVC 8X5XNBDOS UCS B200 M3 Blade Server CON NCFE B200M3 NCFE No CMB SPT SVC 8X5X4 UCS B200 M3 Blade Server CON NCFP B200M3 NCP No CMBSPTSVC24X7X4 UCS B200 M3 Blade Server CON NCFT B200M3 NCFT No CMB SPT SVC 8X5XNBD UCS B200 M3 Blade Server Unified Computing Drive Retention Service With the Cisco Unified Computing Drive Retention UCDR Service you can obtain a new disk drive in exchanse for a faulty drive without returning the faulty drive In exchanse for a Cisco replacement drive yo
3. 2204XP VIC 1240 VIC 1280 4x 10Gb Figure 21 on page 55 2204XP VIC 1240 Emulex or QLogic I O adapter or 4x10Gb Figure 22 on page 55 Cisco UCS Storage Accelerator 4 x 10 Gb 2204XP VIC 1240 Port Expander Card for VIC 1240 4x 10Gb Figure 23 on page 56 2204XP None Emulex or QLogic I O adapter 2x10Gb Figure 24 on page 56 2104XP PID N20 16584 2104XP VIC 1240 None 2x10Gb Figure 25 on page 57 2104XP VIC 1240 Cisco UCS Storage Accelerator 2x10Gb Figure 26 on page 57 Notes 1 Specifically the UCSB MEZ QLG 03 QLogic or UCSB MEZ ELX 03 Emulex adapter 22 Also see Network Connectivity on page 44 for more information To help ensure that your operating system is compatible with the adapter you have selected please check the Hardware Compatibility List at this URL Caveats http www cisco com en US products ps10477 prod technical reference _list html If a VIC 1240 adapter is not installed you must choose an Emulex or QLogic I O adapter to be installed in the mezzanine slot see also Network Connectivity on page 44 Cisco UCS B200 M3 Blade Server CONFIGURING the SERVER STEP 6 ORDER A TRUSTED PLATFORM MODULE Trusted Platform Module TPM is a computer chip microcontroller that can securely store artifacts used to authenticate the platform server These artifacts can include passwords certificates or encryption keys A TPM can also be used to store platform measurements that help ensure that the platform remains trust
4. BMC BladeLogic Standard Edition 6 Cores Support Required BMC BladeLogic Standard Edition 8 Cores Support Required BMC BladeLogic Standard Edition 10 Cores Support Required BMC BladeLogic Advanced Edition 4 Cores Support Required BMC BladeLogic Advanced Edition 6 Cores Support Required BMC BladeLogic Advanced Edition 8 Cores Support Required BMC BladeLogic Standard Edition 10 Cores Support Required Acceptance of Terms Standalone BMC License for UCS Servers Cisco UCS B200 M3 Blade Server 27 CONFIGURING the SERVER Table 15 OSs and Value Added Software for 2 CPU servers continued PID Description VMware 5 VMW VS5 STD 1A VMW VS5 STD 2A VMW VS5 STD 3A VMW VS5 STD 4A VMW VS5 STD 5A VMW VS5 ENT 1A VMW VS5 ENT 2A VMW VS5 ENT 3A VMW VS5 ENT 4A VMW VS5 ENT 5A VMW VS5 ENTP 1A VMW VS5 ENTP 2A VMW VS5 ENTP 3A VMW VS5 ENTP 4A VMW VS5 ENTP 5A VMW VC5 STD 1A VMW VC5 STD 2A VMW VC5 STD 3A VMW VC5 STD 4A VMW VC5 STD 5A UCS VMW TERMS Product ID PID VMware vSphere 5 Standard for 1 Processor 1 Year Support Rqd VMware vSphere 5 Standard for 1 Processor 2 Year Support Rqd VMware vSphere 5 Standard for 1 Processor 3 Year Support Rqd VMware vSphere 5 Standard for 1 Processor 4 Year Support Rad VMware vSphere 5 Standard for 1 Processor 5 Year Support Rqd VMware vSphere 5 Enterprise for 1 Processor 1 Year Support Rqd VMware vSphere 5 Enterprise for 1 CPU 2 Yr Support Rqd VMware vSphere 5 Enterprise for 1 CPU
5. DIMM Population Rules When considering the memory configuration of your server you should take into account the following NM For optimum performance populate at least one DIMM per memory channel per CPU Mm Do not mix RDIMMs with LRDIMMs m Each channel has three DIMM slots for example channel A slots AO A1 and A2 A channel can operate with one two or three DIMMs installed If a channel has only one DIMM populate slot 0 first the blue slot m When both CPUs are installed populate the DIMM slots of each CPU identically Fill bank 0 blue slots in the channels first AO EO BO FO CO GO DO HO Fill bank 1 black slots in the channels second A1 E1 B1 F1 C1 G1 D1 H1 Fill bank 2 white slots in the channels third A2 E2 B2 F2 C2 G2 D2 H2 m Observe the DIMM rules shown in Table 24 Table 24 DIMM Rules for B200 M3 Servers DIMM Parameter DIMMs in the Same Channel DIMMs in the Same Bank DIMM Capacity RDIMM 16 8 or 4 GB DIMMs in the same channel for For best performance DIMMs in the example AO A1 A2 can have same bank for example AO BO different capacities CO DO should have the same capacity LRDIMM 32 GB You cannot mix 32 GB LRDIMMs with You cannot mix 32 GB LRDIMMs with any RDIMM any RDIMM DIMM Speed 1866 1600 or 1333 MHz DIMMs will run at the lowest speed of DIMMs will run at the lowest speed the DIMMs CPUs installed of the DIMMs CPUs installed DIMM Type RDIMMs
6. DR SR LRDIMM DR SR LRDIMM DR SR 1 3V 1 5V 1 3V 1 5V 13V 1 5V 1 3V 1 5 V 1 3 V 1 5V 1 3V 1 5 V 1333 1333 1333 1333 1066 NA 1066 1600 1600 1600 1600 1600 1600 16 GB 1333 1066 NA 16 GB 1333 8 GB 1066 8 GB 1066 NA 1333 NA 1333 NA 1600 NA 1600 NA 1866 NA 1866 NA 1333 NA 1333 NA 1600 NA 1600 NA 1866 NA 1866 NA 1066 NA 1066 NA 1066 NA 1333 NA 1333 MNA 1333 1 NA not applicable 2 These DIMMs operate at 1333 MHz instead of 1600 MHz when used with any E5 2600 CPUs They operate at 1600 MHz when used with E5 2600 v2 CPUs that support 1600 and 1866 MHz speeds 3 1866 MHz DIMMs are only offered and supported with E5 2600 v2 CPU configured servers 16 For optimum performance do not mix DIMMs with different frequencies If you mix DIMM frequencies the system defaults to the lower frequency Do not mix RDIMMs with LRDIMMs DIMMs for CPU 1 and CPU 2 when populated must always be configured identically Memory mirroring reduces the amount of available memory by 50 quantity of DIMMs must be even for mirroring By default starting with UCSM 2 0 4 DIMMs run in memory performance mode 1 5v by BIOS default which yields faster memory speeds than when the BIOS is set for the memory to run in power savings mode Memory speed is dependent on factors such as CPU choice DIMM choice DIMM population how many DIMMs per channel are populated Cisco UCS B200 M3 Blade Server CONF
7. 2 CPU Unl Vrt 1yr Support Reqd 1yr Support Reqd 3yr Support Reqd 5yr Support Reqd 1yr Support Reqd 3Yr Support Reqd A Ma ED da SLES for SAP Applications 1 2 CPU Unl Vrt 3yr Support Reqd SLES for SAP Applications 1 2 CPU Unl Vrt 5yr Support Reqd 26 Cisco UCS B200 M3 Blade Server CONFIGURING the SERVER Table 15 OSs and Value Added Software for 2 CPU servers continued PID Description Product ID PID Red Hat Enterprise Linux RHEL 2S 1G 1A RHEL 2S 1G 3A RHEL 2S 4G 1A RHEL 2S 4G 3A RHEL 2S UG 1A RHEL 2S UG 3A RHEL HA 2S 1A RHEL HA 2S 3A RHEL RS 2S 1A RHEL RS 2S 3A RHEL SFS 2S 1A RHEL SFS 2S 3A BMC BMC 012 BMC SE 4C BMC SE 6C BMC SE 8C BMC SE 10C BMC AE 4C BMC AE 6C BMC AE 8C BMC AE 10C UCS BMC TERMS RHEL 2 Socket 1 Guest 1Yr Svcs Required RHEL 2 Socket 1 Guest 3Yr Svcs Required RHEL 2 Socket 4 Guest 1Yr Svcs Required RHEL 2 Socket 4 Guest 3Yr Svcs Required RHEL 2 Socket U Guest 1Yr Svcs Required RHEL 2 Socket U Guest 3Yr Svcs Required RHEL Option High Availability 2 Socket 1Yr Svcs Required RHEL Option High Availability 2 Socket 3Yr Svcs Required RHEL Option Resilient w Ha 2 Socket 1 Yr Svcs Required RHEL Option Resilient Storage w HA 2 Socket 3 Yr Svcs Reqd RHEL Option Scalable File System 2 Socket 1 Yr Svcs Required RHEL Option Scalable File System 2 Socket 1 Yr Svcs Required BMC BPPM Per Server BMC BladeLogic Standard Edition 4 Cores Support Required
8. 66 oes ew oe eee EI Oe Gre Se ee A Se Gee 37 gas ei Mi eV so OJ ono oe no nm Ae Ree eee mnm 37 DIMM Population Rules L Le ee ee a a 39 DIMM Population Order cc eee tee et k ee ke ee ne ee tee ees 40 Upgrade and Servicing Related Parts 41 Drive and Blade Server Blanking Panels 41 Upgrading your Server from Intel Xeon E5 2600 to Intel Xeon E5 2600 v2 CPUs or downgrading from Intel Xeon E5 2600 v2 to Intel Xeon E5 2600 CPUs 41 Adding an Additional CPU with CPU heat sink 42 Motherboard Lithium Battery cee eee ee ee eee 42 CPU Removal and Installation pick n place Tool Set 42 Thermal Grease with syringe applicator for CPU to Heatsink Seal 42 Air Baffle Replacement Kit 0 cee ee te ete te ee eee 43 CPU Heat Sink Cleaning Kit Le te et eee tee ee 43 Network Connectivity ce et te eee ee ee ee ee ee ene 44 VIC ZANA O o 3 34 oc oad cee heaters eee HERG Booed ee ee ee eee 45 Mezzanine Adapters 0c cece wee ee ee ew eee ee eee eee eee eet eee 46 B200 M3 Configured with 1 CPU 1 et ee te ee ee ee 47 B200 M3 Configured with 2 CPUS Le ee te eee 51 TECHNICAL SPECIFICATIONS aaa ana na aaa a aaa DO Dimensions and Weight cece ee ee ee eee ee eee eee ee m a o ete o o a a 58
9. CPUs Number of DIMM Placement in Banks with memory mirroring implemented DIMMs per CPU CPU 1 CPU 2 2 2 DIMMs in Bank 0 AO BO 2 DIMMs in Bank 0 EO FO 4 4 DIMMs in Bank 0 AO BO CO DO 4 DIMMs in Bank 0 EO FO GO HO 61 3 DIMMs in Bank 0 AO BO CO 3 DIMMs in Bank 0 EO FO GO 3 DIMMs in Bank 1 A1 B1 C1 3 DIMMs in Bank 1 E1 F1 G1 8 4 DIMMs in Bank 0 AO BO CO DO 4 DIMMs in Bank 0 EO FO GO HO 4 DIMMs in Bank 1 A1 B1 C1 D1 4 DIMMs in Bank 1 E1 F1 G1 H1 12 4 DIMMs in Bank 0 AO BO CO DO 4 DIMMs in Bank 0 EO FO GO HO 4 DIMMs in Bank 1 A1 B1 C1 D1 4 DIMMs in Bank 1 E1 F1 G1 H1 4 DIMMs in Bank 2 A2 B2 C2 D2 4 DIMMs in Bank 2 E2 F2 G2 H2 Notes 1 Not recommended for performance reasons m Select the memory mirroring option NO1 MMIRROR as shown in Table 4 on page 13 NOTE System performance is optimized when the DIMM type and guantity are egual No for both CPUs and when all channels are filled equally across the CPUs in the server Cisco UCS B200 M3 Blade Server 15 CONFIGURING the SERVER Caveats System speed is dependent on how many DIMMs are populated per channel See Table 7 for details Table 7 DIMM Memory Speeds DIMM Speed 1333 DIMM 1600 DIMM 1866 DIMM Notes DPC 1DPC 2DPC 3DPC 1DPC 2DPC 3DPC 1DPC 2DPC 3DPC 1333 MHz Capable CPU 1600 MHz Capable CPU 1866 MHz Capable CPU RDIMM RDIMM RDIMM LRDIMM
10. D1TBSATA A03 D500GC3 UCS HDD9O0GI2ZF 106 A03 D600GA2 UCS HDD300GI2F105 A03 D300GA2 PID Description 1 TB 6 Gb SATA 7 2K RPM SFF HDD 500 GB 6 Gb SATA 7 2K RPM SFF HDD 900 GB 6 Gb SAS 10K RPM SFF HDD 600 GB 6 Gb SAS 10K RPM SFF HDD 300 GB 6 Gb SAS 15K RPM SFF HDD 300 GB 6 Gb SAS 10K RPM SFF HDD Drive Type SATA SATA SAS SAS SAS SAS Capacity 1 TB 200 GB 900 GB 600 GB 300 GB 300 GB 146 GB 6 Gb SAS 15K RPM SFF HDD A03 D146GC2 SSDs UCS SD400GOKA2 G SAS 146 GB 400GB SATA 2 5 Enterprise Value SSD UCS SD300GOKA2 E UCS SD200GOKA2 E UCS SD100GOKA2 G UCS SD100GOKA2 E 300 GB Std Height 15mm SATA SSD 200 GB Std Height 15mm SATA SSD 100GB SATA 2 5 Enterprise Value SSD SATA SATA SATA SATA 400 GB 300 GB 200 GB 100 GB 100 GB Std Height 15mm SATA SSD 18 SATA 100 GB Cisco UCS B200 M3 Blade Server CONFIGURING the SERVER NOTE The integrated RAID controller supports hard disk drives HDDs or solid state drives SSDs Write cache is not implemented SSDs are recommended for applications requiring high speed local storage which is an order of magnitude faster than HDDs Q Supported Configurations 1 1 Drive System m Select one of the drives listed in Table 8 1 2 Drive System m Select two identical drives from Table 8 There is no support for mixing of drive types or capacities Caveats m If you select two drives they must be identical in type and capacity
11. Table 7 on page 16 for details Cisco UCS B200 M3 Blade Server 11 CONFIGURING the SERVER STEP 3 CHOOSE MEMORY The standard memory features are m DIMMs Clock speed 1866 1600 or 1333 MHz Ranks per DIMM 1 2 or 4 Operational voltage 1 35 or 1 5 V Registered m DDR3 ECC registered DIMMs RDIMMs or load reduced DIMMS LRDIMMS NM Memory is organized with four memory channels per CPU with up to three DIMMs per channel DPC as shown in Figure 3 Maximum memory capacity is 768 GB B200 M3 configured with 2 CPUs with 32 GB DIMMs Figure 3 UCS B200 M3 Memory Organization o N m OE a 355 55 J KO Al A Gi sei EO Channel A Channel E __Channel B Channel F co cd Channel G iiie 4 Channel H Channel D 12 Cisco UCS B200 M3 Blade Server CONFIGURING the SERVER Choose DIMMs and Memory Mirroring Select the memory configuration and whether or not you want the memory mirroring option The supported memory DIMMs and the mirroring option are listed in Table 4 Q NOTE When memory mirroring is enabled the memory subsystem simultaneously writes identical data to two adjacent channels If a memory read from one of the channels returns incorrect data due to an uncorrectable memory error the system automatically retrieves the data from the other channel A transient or soft error in one channel does not affect the mirrored data and operation continues unles
12. blade server chassis and some may be ordered when needed or may be ordered and kept on hand as spares for future use See Table 26 Table 26 Upgrade and Servicing related Parts for UCS B200 M3 Server Spare Product ID PID Description N20 BBLKD 2 5 inch HDD Blanking Panel N20 CBLKB1 Blade slot blanking panel for UCS 5108 single slot UCSB HS 01 EP CPU Heat Sink for UCS B200 M3 and B420 M3 UCSB BAFF B200 M3 Air Baffle Replacement Kit for B200 M3 Server N20 MBLIBAT T Replacement Lithium Battery for Server Motherboard CR2032 N20 BKVM KVM local IO cable for UCS servers console port UCS CPU EP PNP Pick n place CPU tools for M3 EP 10 8 6 4 2 core CPUs Green UCS CPU EP2 PNP Pick n place CPU tools for M3 EP v2 12 core CPUs Purple UCS CPU GREASE Thermal grease for 2 CPUs all but C220 C240 Blue tip syringe UCSX HSCK UCS Processor Heat Sink Cleaning Kit when replacing a CPU Notes 1 This part is included configured with your UCS server in some cases as determined by the configuration of your server 2 This part is included configured with the UCS 5108 blade server chassis 3 This part is included with the purchase of each optional or spare Intel Xeon E5 2600 CPU processor kit 4 This part is included with the purchase of each optional or spare Intel Xeon E5 2600 v2 CPU processor kit Drive and Blade Server Blanking Panels A drive blanking panel N20 BBLKD must be installed if you remove a disk drive from a U
13. installed in a UCS M3 server Instructions for using this tool set are found at the following link http www cisco com en US docs unified_computing ucs hw chassis install B200M3 html wp1070500 Q NOTE When you purchase a spare CPU the Pick n Place Toolkit is included Thermal Grease with syringe applicator for CPU to Heatsink Seal Thermal grease must be applied to the top of the CPU where it comes in contact with the heat sink Instructions for applying thermal grease are found at http www cisco com en US docs unified_computing ucs hw chassis install B200M3 html wp1070500 CAUTION Use only the thermal grease specified for this server ZA UCS CPU GREASE This thermal grease comes in a blue tipped syringe and is to be used in all servers except the C220 M3 and C240 M3 servers which use thermal grease in a red tipped syringe UCS CPU GREASE2 Thermal grease in the red tipped syringe is only to be used for the C220 M3 and C240 M3 servers and has different thermal conductivity properties which may cause overheating if used in the B200 M3 server Likewise thermal grease in the blue tipped syringe is only to be used for all UCS servers other than the C220 M3 and C240 M3 such as the B200 M3 server and has different thermal conductivity properties which may cause overheating if used in the C220 M3 and C240 M3 servers DO NOT use thermal grease available for purchase at any commercial electronics store If t
14. or LRDIMMs You cannot mix LRDIMMs with You cannot mix LRDIMMs with RDIMMS RDIMMS 1 DPC or 2 DPC 3 DPC DIMMs per Channel DPC See Table 7 on page 16 for See Table 7 on page 16 for valid LRDIMM and RDIMM 1 DPC and 2 valid LRDIMM and RDIMM 3 DPC DPC memory configurations configurations Notes 1 Although you can have different DIMM capacities in the same bank this will result in less than optimal performance For optimal performance all DIMMs in the same bank should be identical 2 Only 1866 1600 and 1333 MHz DIMMs are currently available for the B200 M3 server Cisco UCS B200 M3 Blade Server 39 SUPPLEMENTAL MATERIAL DIMM Population Order Populate the DIMMs for a CPU according to Table 25 Table 25 DIMM Population Order per CPU DIMMs Populate Populate per CPU CPU 1 Slots CPU 2 Slots 1 AO EO 2 AO BO EO FO 3 AO BO CO EO FO GO 4 AO BO CO DO EO FO GO HO 6 AO BO CO EO FO GO A1 B1 C1 E1 F1 G1 8 AO BO CO DO EO FO GO HO A1 B1 C1 D1 E1 F1 G1 H1 12 AO BO CO DO EO FO GO HO A1 B1 C1 D1 E1 F1 G1 H1 A2 B2 C2 D2 E2 F2 G2 H2 Notes 1 Not recommended for performance reasons 40 Cisco UCS B200 M3 Blade Server SUPPLEMENTAL MATERIAL Upgrade and Servicing Related Parts This section lists the upgrade and servicing related parts you may need during the life of your server Some of these parts are configured with every server or with every UCS 5108
15. order one optional internal USB 2 0 drive The USB drive ordering information is listed in Table 14 Table 14 USB 2 0 Drive Product ID PID PID Description UCS USBFLSH S 4GB 4GB Flash USB Drive shorter for all M3 servers NOTE A clearance of 0 950 inches 24 1 mm is required for the USB device to be inserted and removed see the following figure d 295 850 CLE NCE FO use To SLIDE OT pr zzz Th ol IP AP EE ama JE Boo Ni ZZ gt TO See Figure 5 on page 36 for the location of the USB connector NOTE When the Cisco 4GB USB key is purchased with a server it is pre installed into the internal USB port and held firmly in place with a clip to protect it from shock and vibration during shipment and transportation This clip also prevents the USB key from undergoing shock and vibration during ongoing customer operational use Q Cisco UCS B200 M3 Blade Server 25 CONFIGURING the SERVER STEP 9 CHOOSE OPERATING SYSTEM AND VALUE ADDED SOFTWARE Several operating systems and value added software programs are available Select as desired from Table 15 Table 15 OSs and Value Added Software for 2 CPU servers PID Description Product ID PID Microsoft Windows Server MSWS 08R2 STHV MSWS 08R2 ENHV MSWS 08R2 DCHV2S MSWS 12 ST2S MSWS 12 DC2S MSWS 12 ST2S NS MSWS 12 DC2S NS Windows Svr 2008 ST media R2 ST 1 4CPU 5CAL Windows Svr 2008
16. the UCS B200 M3 blade server and the Fabric Extender modules in the UCS 5108 blade server chassis The UCS B200 M3 server plugs into the front of the UCS 5108 blade server chassis The Fabric Extender modules plug into the back of the UCS 5108 series blade server chassis A midplane connects the UCS B200 M3 blade server to the Fabric Extenders Figure 8 shows an example configuration where 2 x 10G KR ports are routed from the VIC 1240 adapter to the Fabric Extender modules and the remaining 2 x 10G KR ports are routed from the mezzanine adapter to the Fabric Extender modules Figure 8 UCS B200 M3 Connections to the Fabric Extenders To Fabric Interconnects To Fabric Interconnects UCS 5108 Blade Server Chassis e Tr 3 mi Mezzanine Adapter lt VIC 1240 Adapter mezranine slot VIC 1240 slot B200 M3 Blade Server The server accommodates two types of network adapters One is the Cisco VIC 1240 adapter The other is a Cisco adapter Emulex or QLogic I O adapter or Cisco Storage Accelerator adapter The VIC 1240 is the only adapter that can be used in the VIC 1240 slot AU other types of adapters plug into the mezzanine slot 44 Cisco UCS B200 M3 Blade Server SUPPLEMENTAL MATERIAL The network adapter options are m Cisco VIC 1240 adapter This adapter plugs into the VIC 1240 slot and is natively capable of 4x10Gb ports and 256 PCle devices The capabilities of the adapter can easily be expanded by using the Port Expande
17. 00 95 15 6 7 2 GT s 1333 UCS CPU E5 2643 E5 2643 3 30 130 10 4 8 GT s 1600 UCS CPU E5 2609 E5 2609 2 40 80 10 4 6 4 GT s 1066 Notes 1 If higher or lower speed DIMMs are selected than what is shown in the table for a given CPU the DIMMs will be clocked at the lowest common denominator of CPU clock and DIMM clock 2 1866 MHz DIMMs are supported only with Intel Xeon E5 2600 v2 CPUs Supported Configurations 1 One CPU Configuration m Choose one CPU from any one of the rows of Table 3 on page 9 2 Two CPU Configuration m Choose two identical CPUs from any one of the rows of Table 3 on page 9 Caveats m The B200 M3 configured with 1 CPU provides limited network connectivity options The following restrictions apply A virtual interface card VIC the VIC 1240 must always be installed in the VIC 1240 mezzanine connector 10 Cisco UCS B200 M3 Blade Server CONFIGURING the SERVER The connectivity options are e VIC 1240 installed in VIC 1240 slot and no adapter installed in the mezzanine slot e VIC 1240 installed in VIC 1240 slot and a Port Expander Card for VIC 1240 installed in the mezzanine slot m See Network Connectivity on page 44 for complete information on network connectivity support for a B200 M3 configured with 1 CPU or 2 CPUs NM For optimal performance select DIMMs with the highest clock speed for a given processor m System speed is dependent on how many DIMMs are populated per channel See
18. 3 Yr Support Rqd VMware vSphere 5 Enterprise for 1 Processor 4 Year Support Rqd VMware vSphere 5 Enterprise for 1 CPU 5 Yr Support Rqd VMware vSphere 5 Enterprise Plus for 1 Processor 1 Year Support Rqd VMware vSphere 5 Enterprise Plus for 1 CPU 2 Yr Support Rad VMware vSphere 5 Enterprise Plus for 1 Processor 3 Year Support Rqd VMware vSphere 5 Enterprise Plus for 1 Processor 4 Year Support Rqd VMware vSphere 5 Enterprise Plus for 1 Processor 5 Year Support Rqd VMware vCenter 5 Server Standard 1 yr support reguired VMware vCenter 5 Server Standard 2 yr support reguired VMware vCenter 5 Server Standard 3 yr support reguired VMware vCenter 5 Server Standard 4 yr support reguired VMware vCenter 5 Server Standard 5 yr support reguired Acceptance of Terms Standalone VMW License for UCS Servers Q NOTE For additional information see OS hypervisor support matrix at the following link http www cisco com en US products ps10477 prod_technical_reference_list html 28 Cisco UCS B200 M3 Blade Server CONFIGURING the SERVER STEP 10 CHOOSE OPERATING SYSTEM MEDIA KIT Choose the optional operating system media listed in Table 16 Table 16 OS Media Product ID PID RHEL 6 SLES 11 MSWS 08R2 STHV RM MSWS 08R2 ENHV RM MSWS 08R2 DCHV RM Cisco UCS B200 M3 Blade Server PID Description RHEL 6 Recovery Media Only Multilingual SLES 11 media only multilingual Windows Svr 2008 R2 ST 1 4CPU 5CAL Medi
19. 56 Cisco UCS B200 M3 Blade Server SUPPLEMENTAL MATERIAL Connectivity using the Cisco UCS 2104XP Fabric Extender The options shown in Figure 25 and Figure 26 demonstrate how the UCS B200 M3 blade server connects to a UCS 2104XP Fabric Extender With this option the mezzanine connector can either be empty or contain an independent Cisco Storage Accelerator adapter that communicates with CPU 2 through the PCle bus In Figure 25 one port from the VIC 1240 is channeled to 2104XP Fabric Extender A and one is channeled to 2104XP Fabric Extender B The result is 10 Gbps of bandwidth to each Fabric Extender With this option no adapter is located in the mezzanine connector Figure 25 Option 1 VIC 1240 to UCS 2104XP Fabric Extender no mezzanine adapter Ho Merranine Adapter mstalled VIC 1240 Adapter In Figure 26 one port from the VIC 1240 is channeled to 2104XP Fabric Extender A and one is channeled to 2104XP Fabric Extender B The result is 10 Gbps of bandwidth to each Fabric Extender The Cisco Storage Accelerator adapter is located in the mezzanine connector as an independent device controlled by CPU 2 Figure 26 Option 2 VIC 1240 to UCS 2104XP Fabric Extender Cisco Storage Accelerator installed uma E 2 E Cisco Storage Accelerator WIC 1240 Adapter Cisco UCS B200 M3 Blade Server 57 TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Dimensions and Weight Table 27 UCS B200 M3 Dimensions and Weight Parameter
20. CS server Similarly a blade server blanking panel N20 CBLKB1 must be installed if you remove a half width blade server such as a UCS B200 M3 server from a blade server chassis These panels are required to maintain system temperatures at safe operating levels and to keep dust away from system components Upgrading your Server from Intel Xeon E5 2600 to Intel Xeon E5 2600 v2 CPUs or downgrading from Intel Xeon E5 2600 v2 to Intel Xeon E5 2600 CPUs See the following link http www cisco com en US docs unified_computing ucs hw CPU IVB install IVB B html Cisco UCS B200 M3 Blade Server 41 SUPPLEMENTAL MATERIAL Adding an Additional CPU with CPU heat sink All Cisco UCS two CPU socket capable servers can be upgraded from having one to having two CPUs configured You will need to order and install a heat sink when adding any additional CPU to a server Instructions for installing the new CPU and heat sink can be found at the following link http www cisco com en US docs unified_computing ucs hw chassis install B200M3 html wp1070500 Motherboard Lithium Battery You can order a replacement motherboard battery Installation instructions are found at this link http www cisco com en US docs unified_computing ucs hw chassis install B200M3 html wp1034829 CPU Removal and Installation pick n place Tool Set The Pick n Place tool set is used to install a CPU in its socket without damage It must be used each time a CPU is
21. CSM upgrades The Unified Computing Support Service includes flexible hardware replacement options including replacement in as little as two hours There is also access to Cisco s extensive online technical resources to help maintain optimal efficiency and uptime of the unified computing environment You can choose a desired service listed in Table 17 Table 17 Unified Computing Support Service Product ID PID On Site Description CON PREM B200M3 Yes ONSITE 24X7X2 UCS B200 M3 Blade Server CON OSP B200M3 Yes ONSITE 24X7X4 UCS B200 M3 Blade Server CON OSE B200M3 Yes ONSITE 8X5X4 UCS B200 M3 Blade Server CON OS B200M3 Yes ONSITE 8X5XNBD UCS B200 M3 Blade Server CON S2P B200M3 No SMARTNET 24X7X2 UCS B200 M3 Blade Server CON SNTP B200M3 No SMARTNET 24X7X4 UCS B200 M3 Blade Server CON SNTE B200M3 No SMARTNET 8X5X4 UCS B200 M3 Blade Server CON SNT B200M3 No SMARTNET 8X5XNBD UCS B200 M3 Blade Server Cisco UCS B200 M3 Blade Server CONFIGURING the SERVER Unified Computing Warranty Plus Service For faster parts replacement than is provided with the standard Cisco Unified Computing System warranty Cisco offers the Cisco Unified Computing Warranty Plus Service You can choose from several levels of advanced parts replacement coverage including onsite parts replacement in as little as four hours Warranty Plus provides remote access any time to Cisco support professionals who can determine if a return materials authorization RMA is requi
22. EN media R2 EN 1 8CPU 25CAL Windows Svr 2008 R2 2 CPU Data Center Windows Server 2012 Standard 2 CPU 2 VMs Windows Server 2012 Datacenter 2 CPU Unlimited VMs Windows Server 2012 Standard 2 CPU 2 VMs No Cisco SVC Windows Server 2012 Datacenter 2 CPU Unlim VM No Cisco SVC SUSE SLES SVR 2S 1G 1A SUSE Linux Enterprise Srvr SLES SVR 2S 1G 3A SLES SVR 2S 1G 5A SLES SVR 2S UG 1A SLES SVR 2S UG 3A SLES SVR 2S UG 5A SLES SHA 2S 1A SLES SHA 25 3A SLES SHA 2S 5A SLES HGC 2S 1A SLES HGC 2S 3A SLES HGC 2S 5A SLES SAP 2S 1G 1A SLES SAP 2S 1G 3A SLES SAP 2S 1G 5A SLES SAP 2S UG 1A SLES SAP 2S UG 3A SLES SAP 2S UG 5A 1 2 CPU 1 Phys SUSE Linux Enterprise Srvr 1 2 CPU 1 Phys SUSE Linux Enterprise Srvr 1 2 CPU 1 Phys SUSE Linux Enterprise Svr 1 2 CPU Unl Vrt SUSE Linux Enterprise Svr 1 2 CPU Unl Vrt SUSE Linux Enterprise Svr 1 2 CPU Unl Vrt 5yr Support Reqd SUSE Linux High Availability Ext 1 2 CPU 1yr Support Reqd SUSE Linux High Availability Ext 1 2 CPU 3yr Support Reqd SUSE Linux High Availability Ext 1 2 CPU 5yr Support Reqd SUSE Linux GEO Clustering for HA 1 2 CPU 1yr Support Reqd SUSE Linux GEO Clustering for HA 1 2 CPU 3yr Support Reqd SUSE Linux GEO Clustering for HA 1 2 CPU 5yr Support Reqd SLES for SAP Applications 1 2 CPU 1 Phys 1yr Support Reqd SLES for SAP Applications 1 2 CPU 1 Phys 3yr Support Reqd SLES for SAP Applications 1 2 CPU 1 Phys 5yr Support Reqd SLES for SAP Applications 1
23. GT s 1866 UCS CPU E52650B E5 2650 v2 2 60 95 20 8 8 GT s 1866 UCS CPU E52640B E5 2640 v2 2 00 95 20 8 7 2 GT s 1600 UCS CPU E52637B E5 2637 v2 3 50 130 15 4 8 GT s 1866 UCS CPU E52630B E5 2630 v2 2 60 80 15 6 7 2 GT s 1600 UCS CPU E52620B E5 2620v2 2 10 80 15 6 7 2 GT s 1600 UCS CPU E52643B E5 2643 v2 3 50 130 25 6 8 GT s 1866 UCS CPU E52650LB 5 2650Lv2 1 70 70 25 10 8 GT s 1600 UCS CPU E52630LB 5 2630Lv2 2 40 60 15 6 7 2 GT s 1600 UCS CPU E52609B E5 2609 v2 2 50 80 10 4 6 4 GT s 1333 Cisco UCS B200 M3 Blade Server 9 CONFIGURING the SERVER Table 3 Supported Intel CPUs E5 2600 v2 and E5 2600 Series Processor Family CPUs continued Intel cle Power CacheSize mignestioE Product ID PID Number Freq W MB Cores OPI DIMM Clock GHz Support MHz Intel Xeon E5 26002 UCS CPU E5 2690 E5 2690 2 90 135 20 8 8 GT s 1600 UCS CPU E5 2680 E5 2680 2 70 130 20 8 8 GT s 1600 UCS CPU E5 2670 E5 2670 2 60 115 20 8 8 GT s 1600 UCS CPU E5 2667 E5 2667 2 90 130 15 6 8 GT s 1600 UCS CPU E5 2665 E5 2665 2 40 115 20 8 8 GT s 1600 UCS CPU E5 2660 E5 2660 2 20 95 20 8 8 GT s 1600 UCS CPU E5 2658 E5 2658 2 10 95 20 8 8 GT s 1600 UCS CPU E5 2650 E5 2650 2 00 95 20 8 8 GT s 1600 UCS CPU E5 2650L E5 2650L 1 80 70 20 8 8 GT s 1600 UCS CPU E5 2640 E5 2640 2 50 95 15 6 7 2 GT s 1333 UCS CPU E5 2637 E5 2637 3 00 80 5 2 8 GT s 1600 UCS CPU E5 2630 E5 2630 2 30 95 15 6 7 2 GT s 1333 UCS CPU E5 2630L E5 2630L 2 00 60 15 6 7 2 GT s 1333 UCS CPU E5 2620 E5 2620 2
24. IGURING the SERVER BIOS setting For the DIMMs to run in power savings mode 1 35 V if the DIMM supports this change the BIOS setting to power savings mode m With 3 RDIMMs populated per channel memory always runs at 1 5 V regardless if the BIOS setting is power savings mode 1 35 V or performance mode 1 5 V m With 3 LRDIMMs populated per channel memory can operate at 1 5 V or 1 35 V depending on the BIOS setting m With 3 DIMMs populated per channel 16 GB and 8 GB 1600 MHz RDIMMs run at a maximum speed of 1333 and 1066 MHz respectively for 1600 and 1866 MHz CPUs Other memory devices are limited to 1066 MHz operation when populated at 3 DPC For more information regarding memory see CPUs and DIMMs on page 37 Cisco UCS B200 M3 Blade Server 17 CONFIGURING the SERVER STEP 4 CHOOSE HARD DISK DRIVES or SOLID STATE DRIVES OPTIONAL The UCS B200 M3 can be ordered with or without drives The standard disk drive features are m 2 5 inch small form factor Mm Hot pluggable m Sled mounted Q NOTE The UCS B200 M3 blade server meets the external storage target and switch certifications as described in the following link http www cisco com en US docs switches datacenter mds9000 interoperabilit y matrix Matrix8 html wp323852 Choose Drives The supported drives in the UCS B200 M3 are listed in Table 8 Table 8 Supported Hot Pluggable Sled Mounted HDDs and SSDs Product ID PID HDDs A03
25. NY N A A 13 CONFIGURING the SERVER Supported Configurations 1 B200 M3 configured with 1 CPU without memory mirroring m Select from 1 to 12 DIMMs for CPU 1 note that there are 12 DIMM slots available 2 B200 M3 configured with 1 CPU with memory mirroring tej aie 2 4 6 8 or 12 DIMMs for CPU 1 The DIMMs will be placed by the factory as shown in able 5 Table 5 DIMM Placement With Memory Mirroring B200 M3 configured with 1 CPU Number of DIMMs DIMM Placement in Banks with memory mirroring implemented per CPU CPU 1 2 DIMMs in Bank 0 AO BO 4 DIMMs in Bank 0 AO BO CO DO 6 3 DIMMs in Bank 0 AO BO CO 3 DIMMs in Bank 1 A1 B1 C1 8 4 DIMMs in Bank 0 AO BO CO DO 4 DIMMs in Bank 1 A1 B1 C1 D1 12 4 DIMMs in Bank 0 AO BO CO DO 4 DIMMs in Bank 1 A1 B1 C1 D1 4 DIMMs in Bank 3 A2 B2 C2 D2 Notes 1 Not recommended for performance reasons m Select the memory mirroring option NO1 MMIRROR as shown in Table 4 on page 13 14 Cisco UCS B200 M3 Blade Server CONFIGURING the SERVER 3 B200 M3 configured with 2 CPUs without memory mirroring m Select from 1 to 12 DIMMs per CPU note that there are 12 DIMM slots per CPU 4 B200 M3 configured with 2 CPUs with memory mirroring Bi a A 4 6 8 or 12 DIMMs per CPU The DIMMs will be placed by the factory as shown in able 6 Table 6 DIMM Placement With Memory Mirroring B200 M3 configured with 2
26. Power Specifications ena 45466665 6S ESS HE hos OS OES EGOS GOSS ORS 58 Cisco UCS B200 M3 Blade Server OVERVIEW OVERVIEW Delivering performance versatility and density without compromise the Cisco UCS B200 M3 Blade Server addresses the broadest set of workloads from IT and web infrastructure through distributed database The enterprise class Cisco UCS B200 M3 blade server extends the capabilities of Cisco s Unified Computing System portfolio in a half width blade form factor The Cisco UCS B200 M3 harnesses the power of the latest Intel Xeon E5 2600 v2 and E5 2600 series processor family CPUs with up to 768 GB of RAM using 32 GB DIMMs 2 drives and up to 80 Gbs throughput connectivity Figure 1 Cisco UCS B200 M3 Blade Server Cisco UCS B200 M3 Blade Server DETAILED VIEWS DETAILED VIEWS Blade Server Front View Figure 2 is a detailed front view of the Cisco UCS B200 M3 Blade Server Figure 2 Blade Server Front View Asset pull handle a blank asset tag is provided on which you can add your own label or sticker or you can use a marker to write your asset information on the tag Network link status LED Ejector captive screw Drive bay 1 Drive bay 2 Notes 1 For information about the KVM local I O cable that plugs into the console connector a cable is included with every Cisco UCS 5100 Series blade server chassis accessory kit see ORDER OPTIONAL KVM LOCAL I O CABLE on page 35 Console con
27. S Storage Accelerator adapters LSI Logic SAS 2004 integrated controller m SAS SATA support m RAID O and 1 cache However servers with two HDDs and RAID controllers with cache lack the ability to match the performance of RAID ed SSD without cache which can be configured with this server NOTE The integrated RAID controller does not implement a write K Up to two optional front accessible hot swappable 2 5 inch small form factor SFF SAS or SATA solid state disks SSDs or hard disk drives HDDs An internal USB 2 0 port is also supported A 4 GB USB 2 0 device is available from Cisco Cisco UCS B200 M3 Blade Server BASE SERVER STANDARD CAPABILITIES and FEATURES Table 1 Capabilities and Features continued Capability Feature Description Video The Cisco Integrated Management Controller CIMC provides video m Matrox G200e video controller m Integrated 2D graphics core with hardware acceleration m Supports all display resolutions up to 1920 x 1200 x 16 bpp resolution at 0 Hz m 24 bit color depth for all resolutions less than 1600x1200 m Up to 256 MB video memory Interfaces m Front panel e One console connector see ORDER OPTIONAL KVM LOCAL I O CABLE on page 35 Power subsystem Integrated in the Cisco UCS 5100 series blade server chassis Fans Integrated in the Cisco UCS 5100 series blade server chassis Integrated management The built in Cisco Integrated Management Controller CIMC GUI o
28. Value Heisht 1 95 in 50 mm Width 8 00 in 203 mm Depth 24 4 in 620 mm Weight m Base server weight no CPUs no HDDs no mezzanine adapters or memory 9 62 lbs 4 36 kg m Minimally configured server 1 HDD 2 CPUs a VIC 1240 but no mezzanine adapter 12 50 lbs 5 67 kg m Fully configured server 2 HDDs 2 CPUs all memory VIC 1240 and mezzanine adapter both populated 14 98 lbs 6 79 kg Power Specifications For configuration specific power specifications use the Cisco UCS Power Calculator at https express salire com Go Cisco Cisco UCS Power Calculator aspx Apafi Americas Headquarters Asia Pacific Headquarters Europe Headquarters Cisco Systems Inc Cisco Systems USA Pte Lid Cisco Systems International BY Amsterdam San Jose CA Sirjapore The Netherlands Cisco has more than 200 offices worldwide Addresses phone numbers and fax numbers are listed on the Cisco Website al www cisco com go offices Cisco and the Cisco Logo are trademarks of Cisco Systems Inc andor its affiliates in the U S and other counties A listing of Cisco s trademarks can be found al wwwiciscocomgo trademarks Third party trademarks mentioned are the property of their respective owners The use of the word partner does nat imply a parinership relationship between Cisco and any other company UDOSE 58 Cisco UCS B200 M3 Blade Server
29. a Windows Svr 2008 R2 EN 1 8CPU 25CAL Media Windows Svr 2008 R2 DC 1 8CPU 25CAL Media 29 CONFIGURING the SERVER 30 STEP 11 CHOOSE SERVICE and SUPPORT LEVEL A variety of service options are available as described in this section Unified Computing Warranty No Contract If you have noncritical implementations and choose to have no service contract the following coverage is supplied Three year parts coverage Next business day NBD parts replacement eight hours a day five days a week 90 day software warranty on media Downloads of BIOS drivers and firmware updates UCSM updates for systems with Unified Computing System Manager These updates include minor enhancements and bug fixes that are designed to maintain the compliance of UCSM with published specifications release notes and industry standards Unified Computing Support Service For support of the entire Unified Computing System Cisco offers the Cisco Unified Computing Support Service This service provides expert software and hardware support to help sustain performance and high availability of the unified computing environment Access to Cisco Technical Assistance Center TAC is provided around the clock from anywhere in the world For UCS blade servers there is Smart Call Home which provides proactive embedded diagnostics and real time alerts For systems that include Unified Computing System Manager the support service includes downloads of U
30. aone Adapter in Extender VIC 1240 Slot Adapter in Mezzanine Slot Compatibility 2208XP PIDs UCS IOM 2208XP UCS IOM2208 16FET 2208XP VIC 1240 None 2208XP VIC 1240 Port Expander Card for VIC 1240 2204XP PIDs UCS IOM 2204XP UCS IOM2204 8FET 2204XP VIC 1240 None 2204XP VIC 1240 Port Expander Card for VIC 1240 2104XP PID N20 16584 2104XP VIC 1240 None Cisco UCS B200 M3 Blade Server Ports 4 x 10 Gb 8 x 10 Gb 2 x 10 Gb 4 x 10 Gb 2x 10 Gb Reference Figure 10 on page 47 Figure 11 on page 48 Figure 12 on page 49 Figure 13 on page 49 Figure 14 on page 50 21 CONFIGURING the SERVER 2 B200 M3 configured with 2 CPUs For a B200 M3 configured with 2 CPUs the supported configurations are listed in Table 11 Choose one configuration Table 11 Supported VIC 1240 and Mezzanine Adapter Configurations FIA Adapter in Extender Adapter in Mezzanine Slot Ports Reference Compatibility VIC 1240 Slot 2208XP PIDs UCS IOM 2208XP UCS IOM2208 16FET 2208XP VIC 1240 None 4x10Gb Figure 15 on page 51 2208XP VIC 1240 VIC 1280 8x10Gb Figure 16 on page 52 2208XP VIC 1240 Emulex or QLogic I O adapter or 6x 10Gb Figure 17 on page 52 Cisco UCS Storage Accelerator 4 x 10 Gb 2208XP VIC 1240 Port Expander Card for VIC 1240 8x10Gb Figure 18 on page 53 2208XP None Emulex or QLogic I O adapter 2x10Gb Figure 19 on page 53 2204XP PIDs UCS IOM 2204XP UCS IOM2204 8FET 2204XP VIC 1240 None 2x10Gb Figure 20 on page 54
31. dwidth to each Fabric Extender 48 Cisco UCS B200 M3 Blade Server SUPPLEMENTAL MATERIAL Figure 12 Option 1 VIC 1240 to UCS 2204XP Fabric Extender no mezzanine adapter o 8 8 3 In Figure 13 one port from the VIC 1240 is channeled to 2204XP Fabric Extender A and one is channeled to 2204XP Fabric Extender B The Port Expander Card for VIC 1240 installed in the mezzanine slot acts as a pass through device to channel one port to each of the Fabric Extenders The result is 20 Gbps of bandwidth to each Fabric Extender Figure 13 Option 2 VIC 1240 and Port Expander Card for VIC 1240 to UCS 2204XP Fabric Extender md ft et Cisco UCS B200 M3 Blade Server 49 50 SUPPLEMENTAL MATERIAL Connectivity using the Cisco UCS 2104XP Fabric Extender The option shown in Figure 14 demonstrates how the UCS B200 M3 blade serves connects to a UCS 2104XP Fabric Extender In Figure 14 one port from the VIC 1240 is channeled to 2104XP Fabric Extender A and one is channeled to 2104XP Fabric Extender B The result is 10 Gbps of bandwidth to each Fabric Extender Figure 14 Option 1 VIC 1240 to UCS 2104XP Fabric Extender no mezzanine adapter Na Mezzanine Adapter installed Cisco UCS B200 M3 Blade Server SUPPLEMENTAL MATERIAL B200 M3 Configured with 2 CPUs Connectivity using the Cisco UCS 2208XP Fabric Extender The Cisco UCS 2208XP is the second generation Fabric Extender and shares the same f
32. e Fusion io and LSI Logic adapter Q NOTE Use the steps on the following pages to order servers with the configurable components that you want configured in your servers 8 Cisco UCS B200 M3 Blade Server CONFIGURING the SERVER STEP 2 CHOOSE CPU S The standard CPU features are m Intel Xeon E5 2600 v2 and E5 2600 series processor family CPUs See the following link for instructions on how to upgrade your server from Intel Xeon E5 2600 to Intel Xeon E5 2600 v2 CPUs as well as how to upgrade to 1866 MHz DIMMs supported on E5 2600 v2 CPUs http www cisco com en US docs unified_computing ucs hw CPU IVB install IVB B html m Intel C600 series chipset m Cache size of up to 30 MB for E5 2600 v2 CPUs or 20 MB for E5 2600 CPUs Select CPUs The available CPUs are listed in Table 3 Table 3 Supported Intel CPUs E5 2600 v2 and E5 2600 Series Processor Family CPUs Intel eee Power CacheSize MES DORS Product ID PID Number Freq W MB Cores QPI DIMM Clock GHz Support MHz Intel Xeon E5 2600 v2 UCS CPU E52697B E5 2697 v2 2 70 130W 30 12 8 GT s 1866 UCS CPU E52695B E5 2695 v2 2 40 115 30 12 8 GT s 1866 UCS CPU E52690B E5 2690 v2 3 00 130 25 10 8 GT s 1866 UCS CPU E52680B E5 2680 v2 2 80 115 25 10 8 GT s 1866 UCS CPU E52670B E5 2670v2 2 50 115 25 10 8 GT s 1866 UCS CPU E52667B E5 2667 v2 3 30 130 25 8 8 GT s 1866 UCS CPU E52660B E5 2660 v2 2 20 95 25 10 8 GT s 1866 UCS CPU E52658B E5 2658 v2 2 40 95 25 10 8
33. er 53 SUPPLEMENTAL MATERIAL Connectivity using the Cisco UCS 2204XP Fabric Extender The Cisco UCS 2204XP is a second generation Fabric Extender and shares the same form factor as the current UCS 2100 series The 2204XP is backwards compatible with the UCS 5108 Blade serve chassis The options shown in Figure 20 through Figure 24 demonstrate how the server uses these options VIC 1240 to 2204XP VIC 1240 and VIC 1280 to 2204XP VIC 1240 and Cisco QLogic or Emulex I O adapter to 2204XP VIC 1240 plus Port Expander Card for VIC 1240 to 2204XP QLogic or Emulex I O adapter to 2204XP adapter There is no network connectivity for this kind of adapter instead it NOTE A Cisco Storage Accelerator adapter may also be plugged into the mezzanine provides high speed storase to the system and is controlled by CPU 2 In Figure 20 one port from the VIC 1240 is channeled to 2204XP Fabric Extender A and one is channeled to 2204XP Fabric Extender B The result is 10 Gbps of bandwidth to each Fabric Extender Figure 20 Option 1 VIC 1240 to UCS 2204XP Fabric Extender no mezzanine adapter No Mezzanine Adapter installed VIC 1240 Adapter 54 Cisco UCS B200 M3 Blade Server SUPPLEMENTAL MATERIAL In Figure 21 one port from the VIC 1240 is channeled to 2204XP Fabric Extender A and one is channeled to 2204XP Fabric Extender B The VIC 1280 installed in the mezzanine slot also channels one port to each of the Fabric Extenders T
34. er Card for VIC 1240 m Emulex or QLogic I O adapters Emulex M73KR E 46 Cisco UCS B200 M3 Blade Server SUPPLEMENTAL MATERIAL QLogic M73KR Q m Cisco Storage Accelerator adapters Cisco UCS 785 GB MLC Fusion io ioDrive2 LSI 400 GB SLC WarpDrive The following sections explain the various I O options that are possible with the different Fabric Extenders Cisco UCS 2208XP 2204XP and 2104XP and the VIC 1240 and mezzanine adapters B200 M3 Configured with 1 CPU In a B200 M3 configured with 1 CPU the mezzanine card slot is not under the control of a CPU in a B200 M3 configured with 2 CPUs CPU 2 controls the slot Therefore the only adapter that can be placed in the mezzanine slot in a B200 M3 configured with 1 CPU is the Cisco UCS Port Expander Card for VIC 1240 and the VIC 1240 is always required to be installed in the VIC 1240 slot Connectivity using the Cisco UCS 2208XP Fabric Extender The Cisco UCS 2208XP is the second generation Fabric Extender and shares the same form factor as the current UCS 2100 series The 2208XP is backwards compatible with the UCS 5108 Blade server chassis The options shown in Figure 10 and Figure 11 demonstrate how the server uses these options m VIC 1240 to 2208XP m VIC 1240 plus Port Expander Card for VIC 1240 to 2208XP In Figure 10 two ports from the VIC 1240 are channeled to 2208XP Fabric Extender A and two are channeled to 2208XP Fabric Extender B The result is 20 Gbps o
35. er slot mezzanine adapter not shown installed Notes 1 A USB device installed in this connector must have sufficient clearance to easily slide in and out The Cisco USB device clearance is 0 950 inches 24 1 mm which is a sufficient amount of clearance 36 Cisco UCS B200 M3 Blade Server SUPPLEMENTAL MATERIAL CPUs and DIMMs Physical Layout Memory is organized as shown in Figure 6 Figure 6 UCS B200 M3 Memory Organization oo O a oe Z x 2 ii ok E EE Boda co m AD AMI A2 EZ EL E Channel A Channel E Channel B Channel F Channel G Channel C Channel D Channel H Each CPU controls four memory channels as follows Mm CPU1 Channels A B C and D Bank 0 AO BO CO and DO blue DIMM slots Bank 1 A1 B1 C1 and D1 black DIMM slots Bank 2 A2 B2 C2 and D2 white DIMM slots Mm CPU2 Channels E F G and H Bank 0 EO FO GO and HO blue DIMM slots Cisco UCS B200 M3 Blade Server 37 SUPPLEMENTAL MATERIAL Bank 1 E1 F1 G1 and H1 black DIMM slots Bank 2 E2 F2 G2 and H2 white DIMM slots The DIMM and CPU physical layout is shown in Figure 7 The 12 DIMM slots at the left are controlled by CPU 1 and the 12 DIMM slots on the right are controlled by CPU 2 Figure 7 DIMM and CPU Layout Z EN Channels A D for CPU 1 2o Channels E H for CPU 2 38 Cisco UCS B200 M3 Blade Server SUPPLEMENTAL MATERIAL
36. f bandwidth to each Fabric Extender Figure 10 Option 1 VIC 1240 to UCS 2208XP Fabric Extender no mezzanine adapter ri LAL mio mio 1 KH L H 0G KA Pori Group A Port Group B VI 1240 Adapter No Mezranine Adapter Installed Merzsanine Slot VIC 1240 Slot o Pie wif Cisco UCS B200 M3 Blade Server 47 SUPPLEMENTAL MATERIAL In Figure 11 two ports from the VIC 1240 are channeled to 2208XP Fabric Extender A and two are channeled to 2208XP Fabric Extender B The Port Expander Card for VIC 1240 installed in the mezzanine slot acts as a pass through device to channel two ports to each of the Fabric Extenders The result is 40 Gbps of bandwidth to each Fabric Extender Figure 11 Option 2 VIC 1240 and Port Expander Card for VIC 1240 to UCS 2208XP Fabric Extender AARP PCle x16 Connectivity using the Cisco UCS 2204XP Fabric Extender The Cisco UCS 2204XP is a second generation Fabric Extender and shares the same form factor as the current UCS 2100 series The 2204XP is backwards compatible with the UCS 5108 Blade serve chassis The options shown in Figure 12 and Figure 13 demonstrate how the server uses these options m VIC 1240 to 2204XP m VIC 1240 plus Port Expander Card for VIC 1240 to 2204XP In Figure 12 one port from the VIC 1240 is channeled to 2204XP Fabric Extender A and one is channeled to 2204XP Fabric Extender B The result is 10 Gbps of ban
37. he result is 20 Gbps of bandwidth to each Fabric Extender Figure 21 Option 2 VIC 1240 and VIC 1280 to UCS 2204XP Fabric Extender et it In Figure 22 one port from the VIC 1240 is channeled to 2204XP Fabric Extender A and one is channeled to 2204XP Fabric Extender B The adapter installed in the mezzanine slot also channels one port to each of the Fabric Extenders The result is 20 Gbps of bandwidth to each Fabric Extender Figure 22 Option 3 VIC 1240 and Emulex or QLogic I O Adapter to UCS 2204XP Fabric Extender timi et ee Cisco UCS B200 M3 Blade Server 55 SUPPLEMENTAL MATERIAL In Figure 23 one port from the VIC 1240 is channeled to 2204XP Fabric Extender A and one is channeled to 2204XP Fabric Extender B The Port Expander Card for VIC 1240 installed in the mezzanine slot acts as a pass through device to channel one port to each of the Fabric Extenders The result is 20 Gbps of bandwidth to each Fabric Extender Figure 23 Option 4 VIC 1240 and Port Expander Card for VIC 1240 to UCS 2204XP Fabric Extender Let ed feet Pte ni In Figure 24 there is no VIC 1240 adapter installed In this case a network adapter must be installed in the mezzanine slot Port A and B of the mezzanine adapter connect to the Fabric Extenders providing 10 Gbps per port Figure 24 Option 5 Emulex or QLogic I O Adapter to UCS 2204XP Fabric Extender no VIC 1240 adapter met Nel el bs urana Emuben ot QLogic VO Adapter
38. hese instructions are not followed the CPU may overheat and be destroyed 42 Cisco UCS B200 M3 Blade Server SUPPLEMENTAL MATERIAL NOTE When you purchase a spare CPU the thermal grease with syringe applicator No is included Air Baffle Replacement Kit Air baffles are designed to direct airflow through the server to maintain server temperature at a safe operating level The UCS B200 M3 server comes shipped with two identical air baffles covering the DIMM socket areas of the server These baffles must always remain installed during server operation The Air Baffle Replacement Kit includes the two identical air baffles needed for one UCS B200 M3 server For instructions on how to remove and replace the air baffles see the following link http www cisco com en US docs unified_computing ucs hw chassis install B200M3 html wp1034378 CPU Heat Sink Cleaning Kit The cleaning kit is used to remove the existing thermal compound from the bottom of the heat sink during a CPU replacement process Instructions for cleaning are found at the following link http www cisco com en US docs unified_computing ucs hw chassis install B200M3 html wp1010281 Q NOTE When you purchase a spare CPU the CPU cleaning kit is included Cisco UCS B200 M3 Blade Server 43 SUPPLEMENTAL MATERIAL Network Connectivity This section explains how the UCS B200 M3 server connects to Fabric Interconnects using the network adapters in
39. in the UCS B200 M3 are listed in Table 9 Table 9 Supported Mezzanine Adapters Product ID PID PID Description Connector Virtual Interface Cards VICs UCSB MLOM 40G 01 Cisco UCS VIC 1240 adapter for M3 blade servers Plugs into the VIC 1240 dedicated VIC 1240 slot only This is the only adapter that can be plugged into the slot UCS VIC M82 8P Cisco UCS VIC 1280 dual 40Gb capable Virtual Interface Card Mezzanine 20 Cisco UCS B200 M3 Blade Server CONFIGURING the SERVER Table 9 Supported Mezzanine Adapters continued Product ID PID PID Description Converged Network Adapters CNAs UCSB MEZ QLG 03 Cisco UCS CNA M73KR Q QLogic Adapter UCSB MEZ ELX 03 Cisco UCS CNA M73KR E Emulex Adapter Cisco Storage Accelerators UCSB F FIO 785M Cisco UCS 785 GB MLC Fusion io ioDrive2 UCSB F FIO 365M Cisco UCS 365 GB MLC Fusion io ioDrive2 UCSB F LSI 400S LSI 400 GB SLC WarpDrive Expander Option Connector Mezzanine Mezzanine Mezzanine Mezzanine Mezzanine UCSB MLOM PT 01 Cisco UCS Port Expander Card for VIC 1240 This is a hardware Mezzanine option to enable an additional 4 ports of the VIC 1240 bringing the total capability of the VIC 1240 to dual 4 x 10 GbE Supported Configurations 1 B200 M3 configured with 1 CPU For a B200 M3 configured with 1 CPU the supported configurations are listed in Table 10 Choose one configuration Table 10 Supported VIC 1240 and Mezzanine Adapter Configurations r
40. nector eset button access Beaconing LED and button Blade ejector handle oF Blade health LED 4 Cisco UCS B200 M3 Blade Server BASE SERVER STANDARD CAPABILITIES and FEATURES BASE SERVER STANDARD CAPABILITIES and FEATURES Table 1 lists the capabilities and features of the base server Details about how to configure the server for a particular feature or capability for example number of processors disk drives or amount of memory are provided in CONFIGURING the SERVER on page 7 NOTE NOTE The B200 M3 blade server requires UCS Manager UCSM to operate as part of the UCS system SS m The B200 M3 with E5 2600 CPUs requires UCSM 2 0 2 q or later m The B200 M3 with E5 2600 v2 CPUs requires UCSM 2 1 3 or later Table 1 Capabilities and Features Capability Feature Description Chassis CPU Chipset Memory I O Storage controller Internal storage devices The UCS B200 M3 Blade Server mounts in a Cisco UCS 5100 series blade server chassis One or two Intel E5 2600 v2 or E5 2600 series processor family CPUs Intel C600 series chipset 24 total slots for registered ECC DIMMs for up to 768 GB total memory capacity B200 M3 configured with 2 CPUs using 32 GB DIMMs Mezzanine adapters m One connector for Cisco s VIC 1240 adapter which provides Ethernet and Fibre Channel over Ethernet FCoE m One connector for various types of Cisco adapters Emulex or QLogic adapters and Cisco UC
41. orm factor as the current UCS 2100 series The 2208XP is backwards compatible with the UCS 5108 Blade serve chassis The options shown in Figure 15 throush Figure 19 demonstrate how the server uses these options VIC 1240 to 2208XP VIC 1240 and VIC 1280 to 2208XP VIC 1240 and QLogic or Emulex I O adapter to 2208XP VIC 1240 plus Port Expander Card for VIC 1240 to 2208XP QLogic or Emulex I O adapter to 2208XP NOTE A Cisco Storage Accelerator adapter may also be plugged into the mezzanine adapter There is no network connectivity for this kind of adapter instead it provides high speed storage to the system and is controlled by CPU 2 In Figure 15 two ports from the VIC 1240 are channeled to 2208XP Fabric Extender A and two are channeled to 2208XP Fabric Extender B The result is 20 Gbps of bandwidth to each Fabric Extender Figure 15 Option 1 VIC 1240 to UCS 2208XP Fabric Extender no mezzanine adapter ra HHD n E 10G KH i 1005 KH EH E TOG 106 Ka Part Group B No Mezzanine Adapter installed VI 1240 Adapter VIC 1240 Slot Poke 216 Cisco UCS B200 M3 Blade Server 51 SUPPLEMENTAL MATERIAL In Figure 16 two ports from the VIC 1240 are channeled to 2208XP Fabric Extender A and two are channeled to 2208XP Fabric Extender B The VIC 1280 installed in the mezzanine slot also channels two ports to each of the Fabric Extenders The result is 40 Gbps of bandwidth to each Fabric Extender Figu
42. pport DS pdf For a complete listing of available services for Cisco Unified Computing System see this URL http www cisco com en US products psl0312 serv group home html 34 Cisco UCS B200 M3 Blade Server CONFIGURING the SERVER ORDER OPTIONAL KVM LOCAL I O CABLE The KVM local I O cable ships with every UCS 5100 Series blade server chassis accessory kit The KVM local I O cable provides a connection into the server providing a DB9 serial connector a VGA connector for a monitor and dual USB ports for a keyboard and mouse With this cable you can create a direct connection to the operating system and the BIOS running on the server The KVM local I O cable ordering information is listed in Table 23 Table 23 KVM Local I O Cable Product ID PID PID Description N20 BKVM KVM local IO cable for UCS servers console port Figure 4 KVM Local I O Cable 1 Connector to server front panel Em VGA connector for a monitor pie 9 serial connector Two port USB connector for a mouse and keyboard NOTE The blade chassis ships with the KVM local I O cable Cisco UCS B200 M3 Blade Server 35 SUPPLEMENTAL MATERIAL SUPPLEMENTAL MATERIAL System Board A top view of the UCS B200 M3 system board is shown in Figure 5 Figure 5 UCS B200 M3 System Board 331367 DIMM slots Internal USB connector Diagnostic button CPU and heat sink Mezzanine adapt
43. r CLI processor interface enables you to monitor the server inventory health and system event logs 6 Cisco UCS B200 M3 Blade Server CONFIGURING the SERVER CONFIGURING the SERVER Follow these steps to configure the Cisco UCS B200 M3 Blade Server STEP 1 VERIFY SERVER SKU page 8 STEP 2 CHOOSE CPU S page 9 STEP 3 CHOOSE MEMORY page 12 STEP 4 CHOOSE HARD DISK DRIVES or SOLID STATE DRIVES OPTIONAL page 18 STEP 5 CHOOSE ADAPTERS page 20 STEP 6 ORDER A TRUSTED PLATFORM MODULE page 23 STEP 7 ORDER CISCO FLEXIBLE FLASH SECURE DIGITAL CARDS page 24 STEP 8 ORDER OPTIONAL INTERNAL USB 2 0 DRIVE page 25 STEP 9 CHOOSE OPERATING SYSTEM AND VALUE ADDED SOFTWARE page 26 STEP 10 CHOOSE OPERATING SYSTEM MEDIA KIT page 29 STEP 11 CHOOSE SERVICE and SUPPORT LEVEL page 30 Cisco UCS B200 M3 Blade Server 7 CONFIGURING the SERVER STEP 1 VERIFY SERVER SKU Verify the product ID PID of the server as shown in Table 2 Table 2 PID of the Base UCS B200 M3 Blade Server Product ID PID Description UCSB B200 M3 UCS B200 M3 Blade Server w o CPU memory HDD VIC 1240 adapter or mezzanine adapters The base Cisco UCS B200 M3 blade server does not include the following components They must be selected during product orderins m CPUs Memory Disk drives Cisco adapters such as the VIC 1240 VIC 1280 and Port Expander for VIC 1240 Emulex and QLogic network adapters Cisco UCS Storage Accelerators such as th
44. r Card for VIC 1240 in the mezzanine slot m Cisco VIC 1280 Mezzanine adapter This adapter plugs into the mezzanine slot and is capable of 4x10Gb ports in the UCS B200 M3 server depending on the Fabric Extender chosen see Table 11 on page 22 and 256 PCle devices m Cisco Port Expander Card for VIC 1240 This I O expander plugs into the mezzanine slot and enables full second generation VIC functionality with the VIC 1240 Using the Port Expander Card for VIC 1240 with the VIC 1240 allows you to have 8 ports of 10Gb each depending on the Fabric Extender option chosen see Table 11 on page 22 m QLogic and Emulex adapters m Cisco Storage Accelerators These flash storage devices do not have network connectivity instead they provide independent high speed storage controlled by CPU 2 See Table 9 on page 20 for descriptions NOTE The bandwidth port count on these adapters depends on the Fabric Extender For example the VIC 1280 only supports up to 4x10Gb in this blade because each mezzanine slot or VIC 1240 slot only supports up to 4x10Gb VIC 1240 Adapter The only adapter that can be plugged in to the VIC 1240 slot is the VIC 1240 a Cisco designed PCle based adapter that provides up to eight depending on the Fabric Extender option chosen 10 Gigabit Data Center Ethernet DCE network interfaces There are two groups of four ports on the VIC 1240 Two ports of the first group and two ports of the second group are wi
45. re 16 Option 2 VIC 1240 and VIC 1280 to UCS 2208XP Fabric Extender In Figure 17 two ports from the VIC 1240 are channeled to 2208XP Fabric Extender A and two are channeled to 2208XP Fabric Extender B The adapter installed in the mezzanine slot also channels one port to each of the Fabric Extenders The result is 30 Gbps of bandwidth to each Fabric Extender Figure 17 Option 3 VIC 1240 and Emulex or QLogic I O Adapter to UCS 2208XP Fabric Extender Tee m io ir iji Emulex or QLogic VO Adapter 52 Cisco UCS B200 M3 Blade Server SUPPLEMENTAL MATERIAL In Figure 18 two ports from the VIC 1240 are channeled to 2208XP Fabric Extender A and two are channeled to 2208XP Fabric Extender B The Port Expander Card for VIC 1240 installed in the mezzanine slot acts as a pass through device to channel two ports to each of the Fabric Extenders The result is 40 Gbps of bandwidth to each Fabric Extender Figure 18 Option 4 VIC 1240 and Port Expander Card for VIC 1240 to UCS 2208XP Fabric Extender TEOS TECH Pile 216 Ptla x15 In Figure 19 there is no VIC 1240 adapter installed In this case a network adapter must be installed in the mezzanine slot Port A and B of the mezzanine adapter connect to the Fabric Extenders providing 10 Gbps per port Figure F 19 Option 5 Emulex or QLogic I O Adapter to UCS 2208XP Fabric Extender no VIC 1240 adapter ear Cisco UCS B200 M3 Blade Serv
46. red You can choose a service listed in Table 18 Table 18 UCS Computing Warranty Plus Service Service On Dane Product ID PID Level GSP Site Description CON UCW7 B200M3 UCW7 Yes UC PLUS 24X7X40S UCS B200 M3 Blade Server CON UCW5 B200M3 UCW5 Yes UC PLUS 8X5XNBDOS UCS B200 M3 Blade Server Unified Computing Partner Support Service Cisco Partner Support Service PSS is a Cisco Collaborative Services service offering that is designed for partners to deliver their own branded support and managed services to enterprise customers Cisco PSS provides partners with access to Cisco s support infrastructure and assets to help them m Expand their service portfolios to support the most complex network environments m Lower delivery costs m Deliver services that increase customer loyalty Partner Unified Computing Support Options enable eligible Cisco partners to develop and consistently deliver high value technical support that capitalizes on Cisco intellectual assets This helps partners to realize higher margins and expand their practice PSS is available to all Cisco PSS partners but requires additional specializations and requirements For additional information see the following URL www cisco com go partnerucssupport The two Partner Unified Computing Support Options include m Partner Support Service for UCS m Partner Support Service for UCS Hardware Only Cisco UCS B200 M3 Blade Server 31 CONFIGURING the SERVER Partner S
47. red through the UCS 5108 Blade Server chassis to Fabric Extender A and Fabric Extender B The other two ports of each group are wired to the mezzanine slot as represented in Figure 9 Cisco UCS B200 M3 Blade Server 45 SUPPLEMENTAL MATERIAL Figure 9 VIC 1240 Port Connectivity ARP Variable d of poti depends on mest adapter tipe Mezranine Adapter VI 1240 Adapter The number of ports available at the mezzanine adapter depends on the type of mezzanine adapter that is plugged into the mezzanine slot on the system board The maximum number of ports is four The VIC 1240 senses the type of adapter plugged into the mezzanine slot In the event a Port Expander Card for VIC 1240 occupies the mezzanine slot the four 10G KR ports between the adapters are used for port expansion otherwise they are unused Mezzanine Adapters There are multiple options for the mezzanine slot m O based PCle adapters such as network adapters or m Cisco Storage Accelerator adapters such as Fusion io and LSI cache cards NOTE In a B200 M3 configured with 2 CPUs if a UCS B200 M3 blade server does not have a VIC 1240 installed the mezzanine slot is required to have a QLogic or Emulex I O adapter installed to provide I O connectivity In a B200 M3 configured with 1 CPU however a VIC 1240 must always be installed Specific examples of mezzanine adapters are m Cisco adapters VIC 1240 VIC 1280 Port Expand
48. s there is a simultaneous error in exactly the same location on a DIMM and its mirrored DIMM Memory mirroring reduces the amount of memory available to the operating system by 50 because only one of the two populated channels provides data The supported memory DIMMs in the UCS B200 M3 are listed in Table 4 Table 4 Supported DDR3 DIMMs and Memory Mirroring Option Product ID PID DIMM Options UCS ML 1X324RY A UCS ML 1X324RZ A UCS MR 1X162RY A UCS MR 1X162RZ A UCS MR 1X082RY A UCS MR 1X082RX A UCS MR 1X082RZ A UCS MR 1X041RY A PID Description 32 GB DDR3 1600 MHz LRDIMM PC3 12800 4R x4 1 35V 32 GB DDR3 1866 MHz LRDIMM PC3 14900 4R x4 1 5 V 16 GB DDR3 1600 MHz RDIMM PC3 12800 2R x4 1 35V 16 GB DDR3 1866 MHz RDIMM PC3 14900 2R x4 1 5V 8 GB DDR3 1600 MHz RDIMM PC3 12800 2R x4 1 35V 8 GB DDR3 1333 MHz RDIMM PC3 10600 2R x4 1 35v 8 GB DDR3 1866 MHz RDIMM PC3 14900 2R x4 1 5V 4 GB DDR3 1600 MHz RDIMM PC3 12800 1R x4 1 35V Memory Mirroring Option NO1 MMIRROR Notes Memory mirroring option 1 1866 MHz DIMMs are supported only with Intel Xeon E5 2600 v2 CPUs 2 Dual voltage DIMM operates at 1 5 V with BIOS is set for memory performance mode default or 1 35 V when BIOS is set for power savings mode 3 No longer shipping as of 11 9 2013 Cisco UCS B200 M3 Blade Server Voltage 1 5 1 5V zal 3 V 2 1 2 1 5V 2 1 35 V 35 V 35 V 35 V 35 V Ranks DIMM N N NY
49. stfeontas Spec Sheet cisco Cisco UCS B200 M3 Blade Server Cisco SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR SAN JOSE CA 95134 REV B 20 NOVEMBER 25 2013 WWW CISCO COM OVERVIEW cic c ete Oe viabiaw tags aes eee DETAILED VIEWS oc toca ote bav o a Saw ka a kai Blade Server Front View c0 cc eee wees ee ee BASE SERVER STANDARD CAPABILITIES and FEATURES CONFIGURING the SERVER 0c cece n nan nan nn nn nona STEP 1 VERIFY SERVERSKU 2 oO Gp A owas ae eteri cessos ee oe a da STEP 2 CHOOSE CPUS o2 hoes eae eee ee eee ee ae oe eee oe eee eae STEP 3 CHOOSE MEMORY 2 cece ee eee ee ee eee ee eee 12 STEP 4 CHOOSE HARD DISK DRIVES or SOLID STATE DRIVES OPTIONAL 18 SIEP CHOOSE ADAPTERS uw eseae hb eee eee eee doe aaa eos eee eee ae ade 20 STEP 6 ORDER A TRUSTED PLATFORM MODULE 23 STEP 7 ORDER CISCO FLEXIBLE FLASH SECURE DIGITAL CARDS 24 STEP 8 ORDER OPTIONAL INTERNAL USB 2 0 DRIVE 25 STEP 9 CHOOSE OPERATING SYSTEM AND VALUE ADDED SOFTWARE 26 STEP 10 CHOOSE OPERATING SYSTEMMEDIAKIT 29 STEP 11 CHOOSE SERVICE and SUPPORTLEVEL 30 ORDER OPTIONAL KVM LOCAL I O CABLE 0 2 0 2 ee Lee 35 SUPPLEMENTAL MATERIAL 0 00 cece eee eee ee ee et DO SVEN BOA 225 oe abbas eee eee Oe Oe ee bee ee PRULE oe eas 36 CPUS ana DIMMS es a a oe ese
50. u provide a signed Certificate of Destruction CoD confirming that the drive has been removed from the system listed is no lonser in service and has been destroyed Sophisticated data recovery technigues have made classified proprietary and confidential information vulnerable even on malfunctioning disk drives The UCDR service enables you to retain your drives and ensures that the sensitive data on those drives is not compromised which reduces the risk of any potential liabilities This service also enables you to comply with regulatory local and federal reguirements If your company has a need to control confidential classified sensitive or proprietary data you might want to consider one of the Drive Retention Services listed in Table 22 Q NOTE Cisco does not offer a certified drive destruction service as part of this service Cisco UCS B200 M3 Blade Server 33 CONFIGURING the SERVER Table 22 Drive Retention Service Options Service Service Service Description Program Name Level GSP Service Level Product ID PID UCS Support UC SUPP DR UCSD5 8x5xNBD CON UCSD5 B200M3 Service With Drive Onsite Retention UCSD7 24x7x4 Onsite CON UCSD7 B200M3 UCS Warranty Plus UC PLUS DR UCWD5 8x5xNBD CON UCWD5 B200M3 With Drive Onsite Retention UCWD7 24x7x4 Onsite CON UCWD7 B200M3 For more service and support information see the following URL http www cisco com en US services ps2961 ps10312 ps10321 Cisco UC Warranty Su
51. upport Service for UCS provides hardware and software support including triage support for third party software backed by Cisco technical resources and level three support See Table 19 Table 19 Partner Support Service for UCS Product ID PID Po Gee ae Description CON PSJ1 B200M3 PSJ1 No UCS SUPP PSS 8X5XNBD UCS B200 M3 Blade Server CON PSJ2 B200M3 PSJ2 No UCS SUPP PSS 8X5X4 UCS B200 M3 Blade Server CON PSJ3 B200M3 PSJ3 No UCS SUPP PSS 24X7X4 UCS B200 M3 Blade Server CON PSJ4 B200M3 PSJ4 No UCS SUPP PSS 24X7X2 UCS B200 M3 Blade Server Partner Support Service for UCS Hardware Only provides customers with replacement parts in as little as two hours See Table 20 Table 20 Partner Support Service for UCS Hardware Only Product ID PID poo ae Description CON PSW2 B200M3 PSW2 No UCS W PL PSS 8X5X4 UCS B200 M3 Blade Server CON PSW3 B200M3 PSW3 No UCS W PL PSS 24X7X4 UCS B200 M3 Blade Server CON PSW4 B200M3 PSW4 No UCS W PL PSS 24X7X2 UCS B200 M3 Blade Server Unified Computing Combined Support Service Combined Services makes it easier to purchase and manage required services under one contract SMARTnet services for UCS help increase the availability of your vital data center infrastructure and realize the most value from your unified computing investment The more benefits you realize from the Cisco Unified Computing System Cisco UCS the more important the technology becomes to your business These services allow you to
52. worthy Authentication ensuring that the platform can prove that it is what it claims to be and attestation a process helping to prove that a platform is trustworthy and has not been breached are necessary steps to ensure safer computing in all environments The TPM ordering information is listed in Table 12 Table 12 Trusted Platform Module Product ID PID PID Description UCSX TPM1 001 Trusted Platform Module for UCS NOTE The module used in this server conforms to TPM v1 3 as defined by the Trusted Computing Group TCG Q Cisco UCS B200 M3 Blade Server 23 CONFIGURING the SERVER STEP 7 ORDER CISCO FLEXIBLE FLASH SECURE DIGITAL CARDS Dual SDHC flash card sockets are provided on the front left side of the server NOTE Currently use of a single Flex Flash SD card for boot or for data is dv supported Dual card support mirrored will be enabled with future software k updates The SDHC card ordering information is listed in Table 13 Table 13 Supported Configurations Secure Digital Card s Product ID PID PID Description UCS SD 16G 16GB SD Card module for UCS Servers NOTE The SD card transfer rates are m Sequential reads 23 MB s Q m Sequential writes 20 MB s Supported Configurations 1 Select one or two Cisco Flexible Flash secure digital cards 24 Cisco UCS B200 M3 Blade Server CONFIGURING the SERVER STEP 8 ORDER OPTIONAL INTERNAL USB 2 0 DRIVE You may