Tripp Lite SmartOnline 100-120V 1.5kVA 1.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard pre-installed, 2U Rack/Tower, USB, DB9 Serial

image

Contents

1. General Info OUTPUT a Supported i Output Voltage Regulation Line 2 Mode Output Voltage Regulation Ano Economy Line Mode ale 10 Output Voltage Regulation Battery 2 Mode Output Receptacles 6 5 15R Load Management Receptacles Two switchable 5 15R load banks bank 1 two outlets bank 2 four outlets Output AC Waveform AC Mode Sine wave 2 5 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com INPUT Rated input current Maximum Load 12A BATTERY Full Load Runtime min 5 min 1200w Half Load Runtime min 14 min 600w Expandable Battery Runtime Extended runtime supported via optional external battery packs External Battery Pack Compatibility BP48V24 2U limit 1 BP48V60RT 3U multi pack compatible BP48V27 2US multi pack compatible DC System Voltage VDC 4 Battery Recharge Rate Included Batteries Internal UPS Replacement Battery RBC94 2U Cartridge Battery Access Front panel battery access door Battery Replacement Description Hot swappable user replaceable batteries VOLTAGE REGULATION Voltage Regulation Description Online double conversion power conditioning Overvoltage Correction 2 output voltage regulation during overvoltages to 150 Undervoltage Correction 2 output voltage regulation during undervoltages to 80 Severe Undervoltage Correction 2 output voltage regulation during undervoltages to 65 under 70 load
2. 15 Category A EMI WARRANTY Product Warranty Period Worldwide 2 year limited warranty Connected Equipment Insurance i i U S Canada amp Puerto Rico 250 000 Ultimate Lifetime Insurance 2015 Tripp Lite All rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice Photos may differ slightly from final products 5 5
3. TRIPP LITE Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com SmartOnline 100 120V 1 5kVA 1 2kW On Line Double Conversion UPS Extended Run SNMP Webcard pre installed 2U Rack Tower USB DB9 Serial MODEL NUMBER SU1500RTXL2UN Description Tripp Lite Smart Online UPS systems offer high performance power protection ideal for critical server and network equipment in datacenters computer rooms and network closets Online double conversion Uninterruptible Power Supply UPS maintains perfectly regulated output power by continuously converting raw AC input to DC then re converting output back to AC Fully regulated sine wave AC output with 2 voltage regulation powers network equipment continuously even during severe brownouts and overvoltages all without depleting UPS battery reserves Maintains battery derived AC output during power failures with zero transfer time Extended runtime options available High 97 efficient operation in optional economy mode saves BTU heat output and energy costs Network management interfaces support communications via USB RS 232 contact closure and PRE INSTALLED SNMPWEBCARD network interface Built in DB9 port offers both enhanced RS 232 data and basic contact closure monitoring ability HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X Includes PowerAlert monitoring so
4. eit 15 to 50 degrees Celsius Relative Humidity 0 to 95 non condensing AC Mode BTU Hr Full Load 609 7 COMMUNICATIONS Communications Interface Contact closure DB9 Serial EPO emergency power off Pre installed network card Slot for SNMP Web interface USB HID enabled Includes PRE INSTALLED SNMPWEBCARD interface card Supports detailed monitoring of UPS and site power conditions Network Monitoring Port Description 415 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com PowerAlert Software Included Communications Cable USB and DB9 cabling included WatchDog Compatibility Supports Watchdog application OS and hard reboot restart options for remote applications LINE BATTERY TRANSFER Transfer Time No transfer time 0 ms in online double conversion mode Low Voltage Transfer to Battery 80V 100 load 65V lt 70 load Power Setpoint High Voltage Transfer to Battery 150 Power Setpoint SPECIAL FEATURES Cold Start Startup in Battery Mode f During a Power Failure Cold start operation supported High Availability UPS Features Automatic inverter bypass Hot swappable batteries Green Energy Saving Features High efficiency economy mode operation Individually controllable load banks Schedulable daily hours of economy mode operation CERTIFICATIONS UPS Certifications Tested to UL1778 USA Tested to CSA Canada Tested to NOM Mexico Meets FCC Part
5. ftware and complete cabling Emergency Power Off EPO interface LED display Highlights e 1500VA 1 5KVA 1200 watt on line double conversion 2U rack tower UPS 100 110 120V 2 output at 50 60Hz High 97 efficiency economy mode option Expandable runtime Hot swap batteries 19 in 48 3cm installed depth USB RS232 EPO and PRE INSTALLED SNMPWEBCARD Front panel status LEDs with detailed load and battery metering 2 independently switchable output load banks NEMA 5 15P input 5 15R outlets Applications Distributed Server Rooms Network Closets Small Business Networks Voice over IP VoIP Phone Systems Package Includes SU1500RTXL2UN UPS with Pre installed SNMPWEBCARD PowerAlert Software and cabling Mounting hardware for 4 post rack enclosures Instruction manual reports UPS operating mode line power availability battery mode operation inverter operation and output power availability Audible alarm with push button momentary alarm cancel Programmable self test Battery independent restart Fault tolerant auto bypass mode Field replaceable hot swappable internal batteries and external battery packs Features e Tripp Lite SU1500RTXL2UN 1500VA 1 5kVA 1200W on line double conversion 2U rackmount UPS e Selectable 100 110 120V output 120V factory preset e NEMA 5 15P input 6 NEMA 5 15R e Two switched load banks support remote reboot or programmable load shedding options e Supports 2 output voltage
6. only USER INTERFACE ALERTS amp CONTROLS 2 switches control off on power status and alarm cancel self test operation Alarm Cancel Operation Power fail alarm can be silenced using alarm cancel switch Audible Alarm Audible alarm indicates UPS startup power failure low battery overload UPS fault and remote shutdown conditions 14 LEDs indicate line power online mode economy bypass mode on battery overload battery low replace battery LED Indicators and fault status information 4 LED meter displays load and battery charge levels LED panel rotates for viewing in rack tower formats Less than 6 hours from 10 to 80 typical full load discharge 3 5 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com SURGE NOISE SUPPRESSION Time UPS Dataline Suppression 1 line TEL DSL 1 in 1 out 10 100Base T Ethernet PHYSICAL Included Mounting Accessory Includes 4 post rackmount installation accessories Description Installation Form Factors Supported 2 Post rackmount 22OSTRMKITWM Wallmount 2POSTRMKITWM Tower 2 9USTAND with Optional Accessories UPS Power Module Dimensions 3 5x17 5x19 hwd in f UPS Power Module Dimensions 8 9 x 44 4 x 48 3 hwd cm UPS Shipping Dimensions hwd 24 8x51 4x61 cm 54 ENVIRONMENTAL Operating Temperature Range 32 to 104 degrees Fahrenheit O to 40 degrees Celsius Storage Temperature Range 5 to 122 degrees Fahrenh
7. regulation and zero transfer time in double conversion mode e Economy mode option offers enhanced 97 efficiency operation reduced power consumption and lower BTU emissions 1 5 Tripp Lite 1111 W 35th Street 6 Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com e 14 minutes runtime at 50 load 600W and 5 minutes at 100 load 1200W with internal batteries e BP48V24 2U limit 1 BP48V60RT 3U multi pack compatible and BP48V27 2US multi pack compatible external battery packs available some configurations require Tripp Lite s External Battery Configuration Software e LED Display reports UPS operating mode line power availability battery mode operation inverter status and output power availability e Audible alarm with push button momentary alarm cancel e 4 post installation hardware included Optional 2POSTRMKITWM enables 2 post rack installation e Single line TEL Network surge suppression e Electronic bypass maintains utility output during a variety of UPS fault conditions e Battery independent restart ensures automatic UPS power up without user interaction after lengthy power outages even when batteries are expired and require replacement e Built in USB RS 232 contact closure and SNMPWEBCARD network interface e HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X e Included PowerAlert UPS monitoring software Specifications

Download Pdf Manuals

image

Related Search

Related Contents

Pioneer PRS-D1200M AV receiver  アルゴス4 カタログ  Samsung XE300TZCI User Manual (Windows 8)  Samsung Samsung C3520 User Manual  Manuale Italiano Seiwa SW501 SW701 SW1101  Transport A la Demande  株式会社 三浦プロテック  EVGA 02G-P3-1469-KR NVIDIA GeForce GTX 560 2GB graphics card  ficha técnica aceite de oliva virgen extra ecológico  Version 1.0 BTCounter 取扱説明書  