Home

Da-Lite Boardroom Electrol

image

Contents

1. Cm m Cm m Cm 45 x 80 52 x 92 101 54 x 96 112 50 8 58 x 104 122 55 3 41 3 45 8 FORMAT DIMENSIONS 2 standard black drop at to Area Diagonal of Case Wt Cm m Cm m Cm ts Kg 165 x 264 175 x 279 184 x 295 i e m e e 221 x 353 1577 254 x 406 ERU SQUARE FORMAT DIMENSIONS screens with have 2 standard black drop at to Overall Length Approx Ship of Case Wt dn Cm Kg 127 x 127 60 x 60 152 x 152 70 x 70 178 x 178 Tw TZ D co oo NI o O1 C9 Co amp 50 x 50 183 x 244 244 x 244 213 x 274 274 x 274 244 x 305 305 x 305 274 x 366 366 x 366 6 7 8 213 x 213 0 2 2 3 Add 3 to overall length of case for mounting brackets Overall case length dimensions x 6 mm Detail dimensional drawings wiring diagrams and installation instructions available upon request Specifications subject to change without notice Custom formats and sizes available upon request Rev 7 13
2. Automatic Electric Projection Screen Model Post Office Box 137 Warsaw Indiana 46581 0137 SPECIFICATION DATA P 674 267 8101 or 800 822 3737 F 574 267 7804 or 877 325 4832 E info da lite com www da lite com Ba BOARDROOM ELECTRO Uo a SUGGESTED SPECIFICATIONS projection screen s H x W electrically operated 120 volt 60Hz not more than 2 4 amp Shall have specially designed motor mounted inside the roller to be three wire with ground quick reversal type oiled for life with automatic thermal overload cutout integral gears capacitor and an electric brake to prevent coasting To have preset but adjustable limit switches to automatically stop picture surface in the down position The roller to be of rigid metal Screen fabric to be flame retardant and mildew resistant fiberglass with black masking borders standard Bottom of fabric shall be formed into a pocket holding a metal rod The ends of the rod shall be protected by heavy duty plastic caps Case to be of wood with metal lined wiring compartment A section of the bottom of the case shall be a door equipped with hinges so that it opens and closes automatically with the lowering and raising of the picture surface When the picture surface is being lowered the door shall drop open by gravity When the picture surface is being raised the two ends of the slat in the bottom pocket of the screen fabric shall engage two hooks on the door to lift it to the closed position wher
3. Hee l BRACKET amp NUT Contractor FURRING 8 1 4 STRIP SLAT HOOK s TBAR SUSPENDED soist FURNISHED j CEILING FURRING WITH CEILING Nes Dp SLAT IN TILE STRIP BASS Ses NN rm PICTOR Sie Rig SURFACE ASSESS 1 L 34 pupiENcE PICTURE access Faa aypience CEILING DOOR La SIDE DOOR a SIDE SLAT 24 2A zz 2 472 HOOK Phone Supervisor Phone Supplier Date Revised CEILING TILE CUT TO 1 4 THICK ATTACH WITH MASTIC Flush mounting recessed above ceiling Flush mounting recessed above ceiling For use May be adapted for 1 4 paneling for ceil with dropped ceiling May also be adapted for ing and doors use with acoustical or other ceiling 3 4 thick but cut to 1 4 thick under doors and screen case VIDEO NTSC 4 3 FORMAT DIMENSIONS 2 standard black drop at top Viewing Nominal Overall Length Approx Ship Area Diagonal of Case Wt hn Cm m Cm k 50 x 67 127 x 170 90 Lbs Hxw_ Cm 43 x 57 109 x 145 aoe 57 x77 145 x 196 60 x 80 152 x 203 69 x 92 175 x 234 109 22 BR A A co o Sli Pand boad bold BA 00 to co wo i N ER P 87 x 116 221 x 295 1337 105 x 140 267 x 356 1577 120 x 160 305 x 406 oloje M 6 amp lo HDTV 16 9 FORMAT DIMENSIONS 2 standard black drop at to Viewing Nominal Approx Ship Area Diagonal of Case Wt
4. J Wireless Remote Control for LVC elect installation metho according to cel Ing type 4 Radio Frequency Remote ms a MOUNTING odd B MOUNTING 1 Radio Frequency Range Extender available uso is Une dd m 7 e e ar Pi for 120V or LVC Switch MH Ed ES nd cng ey Locking Cover Plate for or witch Lu j ey 9 LLL 7 wu E Q Silent Motor SCREW p ii SCREW ZN Qj Key Operated Switch for 120V only NOTE Cannot et Ad ui Vent ud be used with LVC p Mm X ec Q4 No Borders Black masking borders standard r CTR rn m N PEE WAS m 220 Volt 50 Hz Motor Saya STEEL M mRNS O ag STEEL 1 Video Projector Interface Control external An Jp POCKET AUDIENCE 4 External SCB 100 RS 232 Serial Control Board J Sunrace AGGES PICTURE access Qj NET 100 Ethernet Serial Adapter eating T Jae vau A a E AN M E doors E aluminum standard NOTE CAN BE PAINTED THE SAME AS DOOR CEILING TILE CUT TO 1 4 THICK ATTACH WITH MASTIC 4 ite box b 9s standard Offset mounting recessed above ceiling Offset mounting recessed above ceiling For plaster dry wall tile or aneling Doors May be adapted for 3 4 ceiling but cut to and bottom of case painted same finish as 1 4 thick under doors and screen case ceiling METHOD C METHO MOUNTING SUGGESTED BRACKET 1 4 BOLT Project e BRACKET 7 3 8 MOUNTING JOIST Architect Phone i t CS DRYWALL SCREW amx xr MOUNTING
5. e the door will engage a micro switch that will cut off the electrical current to the motor The balance of the bottom of the case shall be a second hinged door with manual opening to provide access Hinges shall be mounted to allow matching of the doors to the ceiling Case to be finished with a black primer coat ready to accept final finish by others To be complete with three position control switch with cover plate Screen to be listed by Underwriters Laboratories Matte White Seamless in all sizes Du Video Spectra 1 5 Available in sizes where both dimensions do not exceed 8 High Power Available in sizes up to 9 x 12 Horizontal seam required when both dimensions exceed 8 WHEN ORDERING MARK APPROPRIATE SELECTIONS SUGGESTED METHODS OF INSTALLATION Select size f hart ther side 1 1 2 elect Size trom charts on other side Pa Select viewing surface CASE LENGTH FABRIC WIDTH EAM i Matte Whitea 3 Video Spectra 1 52 MPG Li High Power 8 AND ABOVE ZGREENGUARD and GREENGUARD Children and Schools Certified MOUNTING BRACKET Optional Accessories FABRIC HEIGHT X WIDTH AS ORDERED UP TO 4 Extra Drop available to lower picture area more than VRITKTRHL of normal Specify total drop at top black or white orat bottom black or white 13 maximum total surface height including picture area Q Single Motor Low Voltage Control LVC external Sarei kad

Download Pdf Manuals

image

Related Search

Related Contents

HSM Classic 105.3  添付文書 - エー・アンド・デイ  HOME ICE MACHINE USER INSTRUCTION MANUAL MODEL TS-061  SPEED BIKE CRX, Art.-Nr.: 3201  Philips RI1703 steam iron  Bedienungsanleitung Manuel d'instructions Handleiding  HyDraw License Server Manager User Manual  取扱説明書  Axis The Theia Varifocal Telephoto Lens  Samsung WB2100  

Copyright © All rights reserved.
Failed to retrieve file