1. 7 50CcOomec Innovative Power Solutions N TYS PR from 1700 to 3300 VA Rack Tower Single phase UPS Control panel _ k NOW OOO PM 11 12 NETYS 144A On Off Load present Load level 5 steps General Alarm Battery fault Replace the battery Overload Battery capacity Normal mode Battery mode flashing Automatic Voltage Regulation active 10 Configuration 11 Programmable outlets 12 Input value 13 UPS test Buzzer off 14 Navigator button 15 Enter OONODOAaABRWDN Standard communication features e LOCAL VIEW ideal UPS monitoring and shutdown point to point solution for Windows Linux and Mac OS X operating systems e HID UPS management based on Windows and Mac OS X embedded service USB interface e MODBUS JBUS RTU RS232 Communication options e NET VISION professional WEB SNMP interface for UPS monitoring and shutdown management of several operating systems e Dry contact interface e Rails Battery extensions N TYS PR 1 NPR B1700 RT 2 NPR B1700 RT 1700 VA 22 min 4 min Ne TYS PR 1 NPR B3300 RT 2 NPR B3300 RT 2200 VA 37 min 72 min 3300 VA 22 min 43 min Catalogue 2013 13
2. Certifications N876 Meets practical needs e Optional battery extension modules EBM to meet all back up time requirements even after installation e Clear and uncluttered LCD interface with buzzers that immediately indicate the operating status of the UPS even for less specialist users e Simplified maintenance and Battery hot swap without closing down other applications Easy to use and to integrate e Wide range of communication protocols available in options including JBUS TCP IP and SNMP for integration into LAN networks or building management systems BMS Easy connections to the applications depending on power via 8 or 8 1 IEC 320 IT standard sockets e Load segmentation function to prioritize loads and manage critical situations e EPO Emergency Power Off emergency stop e RS232 advanced connections for the management of the power supply and local remote shutdown of applications 7 s0comec Innovative Power Solutions NETYS 141A NETYS 143 A Connections NETYS 142 A 1700 VA 2200 VA 1 Fan air vents 2 EPO Emergency Power Off 3 USB serial port 4 RS232 serial port 5 Connector for external battery extension 6 UPS output sockets 2 segments 7 NTP protections RJ45 8 Slot for optional communication boards 9 Input socket o 10 UPS full power output socket T
3. 8 9 3300 VA Technical data NeTYS PR Rack Tower Sn 1700 VA 2200 VA 3300 VA Pn 1350 W 1800 W 2700 W input output 1 1 INPUT Rated voltage 230 V Voltage tolerance 161 V 4 selecting wide mode 276 V 4 Rated frequency 50 60 Hz with automatic selection Mains connection IEC320 C14 10 A IEC320 C20 16 A OUTPUT Automatic Voltage Regulation AVR Rated voltage Rated frequency Wave form Protection Connections BATTERIES Type Back up time COMMUNICATION Interfaces Ethernet adapter Local communication software Data line protection UPS CABINET Dimensions W x D x H Weight STANDARDS Safety EMC Product certification The AVR increases boost 1 the output voltage by 14 when the input voltage drops below 90 of the nominal value The AVR decreases bucks the output voltage by 12 when the input voltage rises above 106 of the nominal value 230 V 5 50 60 Hz 0 1 Sine wave Normal Mode overload 110 for 3 minutes Battery Mode overload 110 for 30 seconds shortcircuit protected 8 10 A x IEC 320 1 16 A x IEC 320 8 10 A x IEC 320 Sealed lead acid maintenance free expected life 3 5 years 6 min 8 min 6 min RS232 USB NET VISION TCP IP amp SNMP optional card Local View NTP data line suppressor RJ45 10 Base T 440 x 436 x 87 mm 440 x 608 x 87 mm 18 kg 28 2 kg 31 5 kg EN 62040 1 AS 62040 1 EN 62040 2 AS 62040 2 CE C Tick N876 1 75 of load
4. Ne TYS PR from 1700 to 3300 VA Rack Tower versatile convertible high performance UPS 12 N A Q o gt eo D NETYS 163 A A secure and professional supply continuity e Ideal solution for protecting small servers networking devices and peripherals e Assures service continuity to critical applications e Designed for professional applications the sinevawe inverter technology assures full compatibility with any kind of load and power supply Tailored to IT networking e The space and time saving tower rack conversion option means it can be installed easily either in tower mode or inside standard 19 rack cabinets depending on the user s needs Simple to install e No configuration needed on first startup e Compact footprint 2U 89 mm for installation in rack cabinets e Attractive design for visible installation in offices e USB port and HID protocol as standard for direct interfacing with Windows systems without the need for additional specialist software Protection for your data line e Integrated NTP protection for LAN ADSL connection against the risk of data line overvoltage Catalogue 2013 The solution for gt Professional and IT equipment gt Servers and networking devices gt CAD graphic workstations with monitors and peripherals gt Control systems Technology gt VI line interactive with AVR sine wave GAMME 162 A

Download Pdf Manuals

image

Related Search

Related Contents

Liebherr 280 EC-H Leaflet  PDFダウンロード  Sharp LL T15V1 (White) 15" LCD Monitor  Teka HX-790 User's Manual  Sandisk 16GB Mobile Ultra microSDHC  PC-ACE Pro32 National Drug Code (NDC)  20 NOV 2007_REV RENE_V 9_1.pmd  Peerless MDJ701 flat panel ceiling mount    

Copyright © All rights reserved.
Failed to retrieve file