Home

Bosch FCP‑500

image

Contents

1. 360 30g 60g www boschsecurity com Protection class as per FCP OC 500 P Permissible operating tem FCP OC 500 P Permissible relative humidity 95 non condensing Permissible air speed In the case of flush ceiling mounting with ceiling mount Required bored hole Installation depth Special features Detection principle FGP OC 500 P All FCP 500 detec FCP OC 500 P Response sensitivity FCP OC 500 P 4 FCP 500 Conventional Automatic Fire Detectors Environmental conditions P33 IP 33 20 C bis 65 C 10 C bis 50 C 20 m s Max 120 m2 Heed local guidelines Maximum installation height Max 16m Heed local guidelines Minimum installation height Out of arm s reach Minimum installation height recommend ed by BOSCH 2 70 m Thickness of the false ceiling Max 32 mm 130 mm 1 mm bis 5 mm 110mm Note Above the false ceiling a free height of at least 110 mm is required Minimum distance to lamps 0 5m Scattered light measurement Combination of scattered light measurement and combustion gas measurement Contamination detection Drift compensation optical section Drift compensation in the gas sensor section lt 0 18 dB m EN 54 7 Optical section lt 0 36 dB m EN 54 7 Gas sensor section in ppm range Ordering Information FCP O 500 Optical Smoke Detector White ultra flat design conventional technology FCP O 500 P Optical Smoke Detecto
2. Fire Alarm Systems FCP 500 Conventional Automatic Fire Detectors BOSCH Invented for life FCP 500 Conventional Automatic Fire Detectors f FCP 500 Conventional Automatic Fire Detectors satisfy the most demanding aesthetic requirements owing to their flat design which offers flush ceiling mounting and the option of color matching The FCP 500 is available as a scattered light smoke detector or as a multi sensor detector with an additional gas sensor The respective versions of the detectors are available in white or transparent with color inserts Functions The smooth flush installation surface means the FCP 500 detectors can be installed in areas with high aesthetic requirements In addition the fire detectors are suitable for areas with heightened dust exposure The detectors and trim rings in the transparent with color inserts version are always supplied complete with reversible printed color rings which offer a choice of 16 colors for individual color matching gt Modern ultra flat design gt Matches the surrounding decor by using color toning inserts gt Smooth easily cleaned detector surface gt Innovative fastening mechanism gt High reliability Sensor technology and signal processing All detectors in the FCP 500 series are equipped with two optical sensors and a pollution sensor The FCP OC 500 multisensor detector contains a gas sensor as an additional detection channel All senso
3. P O 500 FCP O 500 P FCP OC 500 FCP OC 500 P FAA 500 TR W FAA 500 TR P FCA 500 EU FCA 500 E EU FAA 500 BB FAA 500 CB FAA 500 SB FAA 500 SB H FAA 500 SPRING FCP 500 Conventional Automatic Fire Detectors 5 FCP 500 Conventional Automatic Fire Detectors Detector type Operating voltage Current consumption Standby current Alarm current Fault current Protection category Permissible operating temperature Monitoring area Maximum installation height Color FCP O 500 optical 8 59 V DC 33 V DC FCA 500 EU 3 mA FCA 500 E EU 24 mA 47 mA FCA 500 EU 52 mA FCA 500 E EU 58 mA IP 53 s20 PU eee tG PC max 120 m 16m white FCP O 500 P optical 89V DC lt a0 VDC FCA 500 EU 3 mA FCA 500 E EU 24 mA 47 mA FCA 500 EU 52 mA FCA 500 E EU 58 mA IP 53 OC aaah Oe TC max 120 m 16m transparent with color inserts ee Ca n FCP OC 500 optical chemical 85 VDC 33 VDC FCA 500 EU 3 mA FCA 500 E EU 24 mA 47 mA FCA 500 EU 52 mA FCA 500 E EU 58 mA IP 33 AO Ca eet OO AC max 120 m 16 m white FCP OC 500 P optical chemical 3 5 V DC 323 DG FCA 500 EU 3 mA FCA 500 E EU 24 mA 47 mA FCA 500 EU 52 mA FCA 500 E EU 58 mA IP 33 10 C s e tOO AC max 120 m 16 m transparent with color inserts www boschsecurity com 6 FCP 500 Conventional Automatic Fire Detectors Americas Eur
4. ection of smoke which makes it possible to differentiate between smoke and interference agents insects objects In addition the time characteristics and the correlation of the optical sensor signals for the fire or interference detection are evaluated Moreover plausibility checking of the various signals makes it possible to detect errors in the analysis electronics and the LEDs Chemical sensor CO gas sensor The gas sensor 4 detects mainly the carbon monoxide CO that is produced by a fire but it also detects hydrogen H and nitrogen monoxide NO The basic measuring principle is CO oxidation on an electrode and the measurable current that arises from this The sensor signal value is proportional to the concentration of gas The gas sensor delivers additional information to effectively suppress deceptive values Depending on the service life of the gas sensor the FCP OC 500 detector switches off the C sensors after five years of operation The detector will continue to function as an O detector The detector should then be exchanged immediately in order to be able to keep using the higher reliability of detection of the OC detector Pollution sensor The contamination level on the detector surface is continually measured by the pollution sensor 6 the result is evaluated and indicated Contamination of the detector surface leads to active adaptation of the threshold value closed circuit value correction Furth
5. er performance characteristics Various operating states are indicated on the detector by means of a clearly visible two color LED In the event of an alarm the LED flashes red The innovative detector locking which operates on the ballpoint pen principle provides fast and simple insertion and replacement of the detector We recommend the specially developed FAA 500 RTL exchanger device especially in the case of high installation heights To allow convenient detector testing the FAA 500 TTL test adapter with magnet and additional service accessories is available Certifications and Approvals Comply with e EN54 7 2000 A1 2002 A2 2006 Region Certification Germany VdS G 205124 FCP O 500 500 P G 205118 FCP OC 500 500 P Europe CE FCP 500 CPD 0786 CPD 20203 FCP O 500 500 P 0786 CPD 20204 FCP OC500 500 P Installation Configuration Notes e Can be connected to Conventional Fire Panel BZ 1012 1016 1024 1060 Universal Fire Panel UEZ 1000 Universal Fire Panel UGM 2020 FCP 500 Conventional Automatic Fire Detectors 3 Other panels or their receiver modules with identical connection conditions UEZ 2000 LSN BZ 500 LSN FPA 5000 and FPA 1200 via appropriate interfaces e The detectors and detector bases can be used together with the Rotaris lamp by Philips e The FCP OC 500 like the FCP O 500 is planned according to the guidelines for optical detectors see DIN VDE 0833 Part 2 and VDS 2095 e The detec
6. gs When the detector is installed in concrete or wooden ceilings these need to be replaced by the stronger springs FAA 500 SPRING with red markings e Maximum permitted air speed 20 m s e Country specific standards and guidelines must be observed during the planning phase e Technical Specifications Parts Included Detector type Qty Components FCP O 500 1 Optical Smoke Detector White FCP O 500 P 1 Optical Smoke Detector Transparent with Color Inserts FCP OC 500 1 Multisensor Detector Optical Chemical White FCP OC 500 P 1 Multisensor Detector Optical Chemical Transparent with Color Inserts Technical Specifications Electrical Operating voltage 8 5 V DC bis 33 V DC Standby current e FCA 500 EU 3mA e FCA 500 E EU 24mA Alarm current 47mA Fault current e FCA 500 EU 52 mA e FCA 500 E EU 58 mA Alarm resistance 0 Q UL application or 680 Q Fault relay output NC C Indicator output Mechanics Individual display Dimensions Detector Detector with trim ring Detector with cover base and ceiling mount back box Housing material Housing color Front plate color FCP O 500 FCP OC 500 FCP O 500 P FCP OC 500 P Weight FCP OC 500 P FCP O 500 P Trim Ring Relay connects 0 V over 1 5 kQ Two color LED red alarm green test mode 113x55mm 150x55mm 150x110mm Polycarbonate Signal white RAL 9003 Signal white matt Transparent silver gray Without with packaging 180 g 370g 170 g
7. ope Middle East Africa Bosch Security Systems Inc Bosch Security Systems B V 130 Perinton Parkway P O Box 80002 Fairport New York 14450 USA 5600 JB Eindhoven The Netherlands Phone 1 800 289 0096 Phone 31 40 2577 284 Fax 1 585 223 9180 Fax 31 40 2577 330 security sales us bosch com emea securitysystems bosch com www boschsecurity us www boschsecurity com Bosch Security Systems 2011 Data subject to change without notice T1644324107 Cur en US V18 29 Jun 2011 Asia Pacific Represented by Robert Bosch SEA Pte Ltd Security Systems 11 Bishan Street 21 Singapore 573943 Phone 65 6258 5511 Fax 65 6571 2698 apr securitysystems bosch com www boschsecurity asia
8. r Transparent with Color Inserts ultra flat design conventional technology FCP OC 500 Multisensor Detector Optical Chemical White ultra flat design conventional technology FCP OC 500 P Multisensor Detector Optical Chemical Transparent with Color Inserts ultra flat design conventional technology Accessories FAA 500 TR W Trim Ring White for 500 and 520 Series Fire Detectors FAA 500 TR P Trim Ring Transparent with Color Inserts for 500 and 520 Series Fire Detectors FCA 500 EU Conventional Base for the FCP 500 Series detectors FCA 500 E EU Conventional Base EOL for the FCP 500 Series detectors with inte grated EOL resistor FAA 500 BB Ceiling Mount Back Box for ceiling flush installation in false ceilings when mounting 500 and 520 Series Bases and Fire Detectors FAA 500 CB Built in Housing for Concrete Ceilings for installing 500 and 520 Series Fire Detec tors in concrete ceilings In addition you need to order a FAA 500 BB Ceiling Mount Back Box which contains the base and the detector FAA 500 SB Surface Mount Back Box for special applications where it is not possi ble to flush mount the 500 and 520 Series Fire Detectors in a ceiling FAA 500 SB H Surface Mount Back Box with Damp Room Seal for special applications where it is not possi ble to flush mount the 500 and 520 Series Fire Detectors in a ceiling FAA 500 SPRING for Concrete Wooden Ceilings DU 10 units FC
9. r signals are constantly analyzed by the internal signal evaluation electronics and are linked with each other through algorithms www boschsecurity com 2 FCP 500 Conventional Automatic Fire Detectors By linking the optical sensors and the gas sensor the OC detector can also be used in places where the work carried out gives rise to small amounts of smoke steam or dust The alarm will only be triggered automatically if the signal combination corresponds with the detector s characteristic diagram Consequently a very high reliability against false alarms is obtained Optical sensor smoke sensor The optical sensor 1 operates according to the scattered light method The LEDs 3 transmit light at a defined angle into the scattered light area 7 2 3 3 e ee INGA aa 7 In case of fire the light is scattered by the smoke particles and strikes the photo diodes 2 which transform the quantity of light into a proportional electrical signal 4 Interference effects from daylight and commercial lighting sources are filtered out with an optical daylight filter and by the use of electronic filtering and phase locked rectification ambient light stability glare test DIN EN 54 7 The various light emitting and photo diodes of the sensor are individually controlled by the detector electronics Consequently signal combinations are produced that are independent of each other and ideally suitable for the det
10. tors must be installed exclusively in the FCA 500 bases provided In addition the detector base must be installed in an FAA 500 BB ceiling mount back box or in FAA 500 SB surface mount back box Note For flush ceiling mounting with FAA 500 BB The false ceiling may have a maximum thickness of Note 32 mm Above the false ceiling a free height of at least 110 mm is required e FCP 500 detectors are not intended for outdoor use e A hemispherical space with a radius of 50 cm must remain free below the detectors on i a Poe tee gt e s y 2 ee A B X X A 1 Detector 2 Ceiling 3 hemispherical space below the detector e Care must be taken to ensure that neither people larger animals plants nor any objects intrude into this area and that no parts of the detector surface become covered e The detectors may only be installed in a position which is out of arm s reach We therefore recommend a minimum installation height of 2 70 m e The detectors may not be installed in rooms in which data is transmitted by means of high intensity infra red light e g in rooms with IR systems for interpreters e The detectors must be mounted so that they are not exposed to any direct sunlight e A minimum distance of 50 cm from lamps must be maintained The detectors may not be mounted ina cone of light from lamps e The bases are equipped as standard with a spring which is suitable for installation of the detector in false ceilin