1. peerless A V GC X360S W GC X360S B t AW e AmE 4 WARNING ENG This product was designed to be installed on wood stud solid concrete or cinder block walls Before in stalling make sure the supporting surface will support the combined load of the equipment and hardware Screws must be tightly secured Do not overtighten screws or damage can occur and product may fail Never exceed the Maximum Load Capacity Always use an assistant or mechanical lifting equipment to safely lift and position equipment This product is intended for indoor use only Use of this product outdoors could lead to product failure or personal injury For support please call customer care at 1 800 865 2112 Symbols iy X3 Skip to step Screws must get at Do not over tighten screws least three full turns and fit snug WARNING Display center To properly tighten screws Tighten until screw head makes contact then tighten another 1 2 turn Do no overtighten screws 2 date 01 22 13 125 9401 Tools Needed for Assembly 5 16 5 32 1 2 3 date 01 22 13 125 9401 Parts List Part Description Quantit Part Number B Part Number W cover plate 125 P1455 125 2455 1 4 20 x 1 75 carriage bolt 520 1017 520 1017 14 2 2 5 hex head wood screw 500 1005 500 1005 1 4 20 x 1 5 socket pin screw 520 1256 520 1256 con
2. mounts on a cinder block wall the cinder blocks must meet ASTM C 90 specifications and have a minimum nominal width of 8 Do not drill into mortar joints Be sure to mount in a solid part of the block generally 1 25 mm minimum from the side of the block It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity Never attach expansion anchors to concrete or cinder block covered with plaster drywall or other finishing material Level cover plate Mark mounting holes Drill mounting holes into supporting surface gt _ g u 64mm 5 l 2 5 64 mm minimum depth required gt j 0 6 Z9 o 5 16 BUNA 8mm Do not drill into mortar joints 8 date 01 22 13 125 9401 Insert anchor flush to concrete Level wallplate Install using concrete anchors and wood screws provided Maximum 80 in Ib 9 N M 9 date 01 22 13 125 9401 A WARNING Drywall must be 1 2 or thicker Make sure that the wall will safely support the combined load of the equipment and all attached hardware and components Level cover plate and mark the center of the four mounting holes Drill four 1 2 holes through d
3. purpose be longer than the period of the applicable express warranty set forth above Some states do not allow limitations on how long a implied warranty lasts so the above limitation may not apply to you This warranty does not cover damage caused by a service or repairs by the customer or a person who is not authorized for such service or repairs by Peerless b the failure to utilize proper packing when returning the product c incorrect installation or the failure to follow Peerless instructions or warnings when installing using or storing the product or d misuse or accident in transit or otherwise including in cases of third party actions and force majeure In no event shall Peerless be liable for incidental or consequential damages or damages arising from the theft of any product whether or not secured by a security device which may be included with the Peerless product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty is in lieu of all other warranties expressed or implied and is the sole remedy with respect to product defects No dealer distributor installer or other person is authorized to modify or extend this Limited Warranty or impose any obligation on Peerless in connection with the safe of any Peerless product This warranty gives specific legal rights and you may also have other rights which vary from s
4. crete anchor 590 0320 590 0320 1 4 x 20 slope nut 530 0035 530 0035 plastic screw cap 590 1294 590 1294 4 mm allen wrench 560 9646 560 9646 1 4 20 plastic toggler 560 9708 560 9708 1 4 20 nylock nut 530 9413 530 9413 Before beginning make sure you have all parts shown below rammooqgqnw sp NA KS QU N KUN A qa 4 date 01 22 13 125 9401 Wood stud wall Concrete Cinder block t 5 date 01 22 13 125 9401 A WARNING When installing Peerless wall mounts on a wood stud wall covered with gypsum board drywall verify that the woods studs are a minimum of 2 X4 nominal size When installing to more than one stud insure the spacing between studs is at least 16 but does not exceed 24 Do not install over gypsum board thicker than 5 8 Use stud finder to locate and mark stud center lines Level cover plate Mark mounting holes on stud center lines 6 date 01 22 13 125 9401 Drill mounting holes into supporting surface 2 5 64 mm minimum depth required Mounting hole must center on stud Level cover plate Install using wood screws provided 7 date 01 22 13 125 9401 4 amp WARNING ENG When installing Peerless wall mounts on a concrete wall the wall must be at least 8 thick with a minimum compressive strength of 2000 psi When installing Peerless wall
5. rywall NOTE It may be necessary to drill 5 32 pilot holes prior to drilling 1 2 holes Rotate toggler I clockwise to wedge it against inside walls Slide plastic cap forward whi firmly on ring Break off excess 10 date 01 22 13 125 9401 Level cover plate and mark the center of four rectangular mounting holes 1 1 Drill four 5 16 8 mm dia holes through desktop ounting surface NOTE Avoid jamming both slope nuts F together BOTTOM OF DESK doing so may make it difficult to remove slope nut used for tightening After slope nut is secure remove bottom slope nut F LEAVE SPACE IN BETWEEN SLOPE NUTS TIGHTENING SLOPE NUT TIGHTENING SLOPE NUT 5 8 OPEN BOX WRENCH 11 date 01 22 13 125 9401 LIMITED FIVE YEAR WARRANTY Peerless Industries Inc Peerless warrants to original end users of Peerless products will be free from defects in material and workmanship under normal use for a period of five years from the date of purchase by the original end user but in no case longer than six years after the date of the product s manufacture At its option Peerless will repair or replace or refund the purchase price of any product which fails to conform with this warranty In no event shall the duration of any implied warranty of merchantability or fitness for a particular
6. tate to state peerless V Peerless AV 2300 White Oak Circle Aurora IL 60502 Email tech peerlessmounts com Ph 800 865 2112 Fax 800 359 6500 www peerless av com 2012 Peerless Industries Inc 12 date 01 22 13 125 9401