Home
Tripp Lite SmartOnline 100-127V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack, LCD display, USB, DB9 Serial
Contents
1. 122 degrees Fahrenheit 15 to 50 degrees Celsius Relative Humidity 0 to 95 non condensing AC Mode BTU Hr Full Load 80 AC Economy Mode BTU Hr Full Load me AC Economy Mode Efficiency Rating 98 100 Load Operating Elevation ft 0 3000m 0 10 000 ft Audible Noise 50 dBA at 1m front side COMMUNICATIONS Communications Interface USB HID enabled DB9 Serial Contact closure EPO emergency power off Slot for SNMP Web interface Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions DB9 port supports RS232 and contact closure communications PowerAlert Software Included Communications Cable USB and DB9 cabling included WatchDog Compatibility Supports Watchdog application OS and hard reboot restart options for remote applications LINE BATTERY TRANSFER Transfer Time Zero 0 milliseconds in double conversion mode 4 milliseconds economy mode 5 6 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Low Voltage Transfer to Battery 55V at 33 load 70V at 70 load 100V at 100 load 90V full load at 100V nominal setting Power Setpoint High Voltage Transfer to Battery 150 Power Setpoint SPECIAL FEATURES Cold Start Startup in Battery Mode g During a Power Failure Cold start operation supported High Availability UPS Features Automatic inverter bypass Hot swappable batteries Green Energy Sa
2. 60 Hz Supports 50 to 60 Hz and 60 to 50 Hz conversion ON LINE MODE Output frequency is automatically configured to match nominal input frequency on startup Output matches input frequency when 5Hz of nominal Output is regulated to 0 05Hz when input frequency exceeds Frequency Compatibility Details 5Hz of nominal UPS switches to battery mode when input frequency is below 40Hz or above 70Hz FREQUENCY REGULATION CONVERSION MODE Output is regulated to 0 05Hz of selected output frequency input is 40 to 70Hz UPS switches to battery mode when input frequency is below 40Hz or above 70Hz BATTERY MODE Output is regulated to 0 05Hz Output Voltage Regulation Line 2 Mode 2 6 Tripp Lite ieee YY 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Output Voltage Regulation o Economy Line Mode 10 Output Voltage Regulation Battery 3 Mode Output Receptacles 4 5 15R 4 5 15 20R 1 L5 30R ON LINE MODE Maximum output capacity rating is reduced to 2430W 115V 2295W 110V and 2160W 100V FREQUENCY REGULATION CONVERSION MODE Maximum output ratings are reduced in frequency regulation UPS Output Receptacles Surge conversion mode 127 120V 1890 watts 115V 1701 watts 110V 1606 watts 100V 1512 watts OVERLOAD Suppression Only CAPACITY Supports inverter operation up to 105 load continuously 125 load for 3 minutes 150 load for 30 seconds and g
3. A 2700W on line double conversion 3U rackmount UPS e Selectable 100 110 120 127V output 120V factory preset e NEMA L5 30P input 4 NEMA 5 15 20R 4 5 15R amp 1 L5 30R outlets e Two switched 4 outlet load banks support remote reboot or programmable load shedding options e Supports 2 output voltage regulation and zero transfer time in double conversion mode 1 6 Tripp Lite ERRON 35th Street amp Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com e Economy mode option offers enhanced efficiency reduced power consumption and lower BTU emissions e 11 minutes runtime at 50 load 1350W and 4 minutes at 100 load 2700W with internal batteries e BP72V15 2U limit 1 BP72V28RT 3U multi pack compatible and BP72V18 2US multi pack compatible external battery packs available some configurations require Tripp Lite s External Battery Configuration Software e LCD interface reports operating mode plus 9 selectable screens of UPS data Load percentage kW amp kVA Power factor Input voltage amp frequency Output voltage amp frequency Battery voltage and charge percentage Minutes runtime Capacity remaining and Kw hr consumption e LCD interface also supports 16 screens of UPS configuration and setup options e 4 post installation hardware included Optional 2POSTRMKITHD enables 2 post rack installation e Single line TEL Network surge suppression e Electronic bypass maintains utility output during a variety
4. Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com SmartOnline 100 127V 3kVA 2 7kW On Line Highlights Double Conversion UPS Extended Run SNMP ee eens Webcard 3U Rack LCD display USB DB9 Serial ae MODEL NUMBER SU3000RTXLCD3U e 100 110 120 127V 50 60Hz output High efficiency economy mode option e Interactive LCD with 9 selectable screens of UPS and site power data e Expandable runtime Hot swap batteries 26 in 66cm depth e USB RS232 amp EPO ports support for SNMP WEB card option e 2 independently switched load banks e NEMA L5 30P input 4 NEMA 5 15R 4 5 15 20R amp 1 L5 30R Description outlets Tripp Lite Smart Online UPS systems offer high performance power protection ideal for critical server and e This product is ENERGY STAR network equipment in datacenters computer rooms and network closets Online double conversion qualified for its ability to save Uninterruptible Power Supply UPS maintains perfectly regulated output power by continuously converting raw customers money while AC input to DC then re converting output back to AC Fully regulated sine wave AC output with 2 voltage helping to protect the regulation powers network equipment continuously even during severe brownouts and overvoltages all without environment depleting UPS battery reserves Maintains battery derived AC output during power failures with zero transfer Applications time E
5. ent Description Hot swappable user replaceable batteries 3 6 Tripp Lite ERRON 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com VOLTAGE REGULATION a power conditioning maintains 2 output voltage regulation during brownouts and Corrects overvoltages to 150V 0 100 load Corrects brownouts to 70V 70 load amp 55V 33 load USER INTERFACE ALERTS amp CONTROLS Front Panel LCD Display Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data plus configuration of voltage frequency operating mode alarm function and a variety of additional options 2 switches control off on power status and alarm cancel operation 2 additional scroll down and scroll up select Switches os options enable LCD status viewing and configuration options Power fail alarm can be temporarily silenced using alarm cancel switch silent mode alarm configuration option Alarm Cancel Operation available Audible Alarm Audible alarm indicates UPS startup power failure low battery overload UPS fault and remote shutdown conditions Front Panel LCD Yes LED Indicators 7 front panel LEDs indicate line power availability AC to DC conversion battery mode operation inverter mode eco mode operation bypass mode operation and AC output status SURGE NOISE SUPPRESSION UPS AC Suppression Joule Rating 570 UPS AC Suppression Response Instantaneous T
6. ime UPS Dataline Suppression 1 line TEL DSL 1 in 1 out 10 100Base T Ethernet EMI RFI AC Noise Suppression Yes PHYSICAL Installation Form Factors Supported with Included Accessories 7 front panel LEDs indicate line power availability AC to DC conversion battery mode operation inverter mode eco mode operation bypass mode operation and AC output status Included Mounting Accessory Includes 4 post rackmount installation accessories Description Installation Form Factors Supported 2 post rackmount 2POSTRMKITHD with Optional Accessories Primary Form Factor Rackmount UPS Power Module Dimensions 52x17 5x 26 hwd in UPS Power Module Dimensions 13 2x444x66 hwd cm Rack Height U Spaces UPS Power Module Weight Ibs 74 4 6 Tripp Lite ieee YY 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com UPS Power Module Weight kg 33 6 Stepdown Transformer Dimensions hwd in Stepdown Transformer Dimensions hwd cm Included Battery Pack Dimensions hwd in Included Battery Pack Dimensions hwd cm UPS Shipping Dimensions hwd in 12 x 23 x 33 UPS Shipping Dimensions hwd 30 5 x 58 4 x 83 8 N O Shipping Weight Ibs Shipping Weight kg Cooling Method UPS Housing Material Steel O n oO o A D ENVIRONMENTAL Operating Temperature Range 32 to 104 degrees Fahrenheit O to 40 degrees Celsius Storage Temperature Range 5 to
7. of UPS fault conditions e Battery independent restart ensures automatic UPS power up without user interaction after lengthy power outages even when batteries are expired and require replacement e Frequency regulation conversion mode offers generator compatible frequency correction or conversion of frequency from 50 to 60Hz or 60 to 50Hz e Built in USB RS 232 contact closure and optional SNMPWEBCARD accessory monitoring options e HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X e Included PowerAlert UPS monitoring software Specifications OUTPUT ON LINE MODE Maximum output capacity rating is reduced to 2430W 115V 2295W 110V and 2160W 100V FREQUENCY REGULATION CONVERSION MODE Maximum output ratings are reduced in frequency regulation Output Capacity Details conversion mode 127 120V 1890 watts 115V 1701 watts 110V 1606 watts 100V 1512 watts OVERLOAD CAPACITY Supports inverter operation up to 105 load continuously 125 load for 3 minutes 150 load for 30 seconds and gt 150 load for 0 5 seconds before switching to BYPASS when bypass input voltage and frequency are WITHIN bypass limits or SHUTDOWN when bypass input voltage or frequency are OUTSIDE bypass limits C Nominal Output Voltage s 100V 110V 115V 120V 127V Supported i Nominal Voltage Details 120V factory default nominal voltage Frequency Compatibility 50
8. t 150 load for 0 5 seconds before switching to BYPASS when bypass input voltage and frequency are WITHIN bypass limits or SHUTDOWN when bypass input voltage or frequency are OUTSIDE bypass limits Load Management Receptacles Two switchable four outlet load banks Output AC Waveform AC Mode Pure Sine wave Pure Sine wave Output AC Waveform Battery Mode INPUT Rated input current Maximum Load 24A Nominal Input Voltage s Supported 100V AC 110V AC 115V AC 120V AC 127V AC Nominal Input Voltage Description 120V factory default UPS Input Connection Type L5 30P Input Circuit Breakers 40A UPS Input Cord Length ft O UPS Input Cord Length m Recommended Electrical Service 30A 120V Input Phase Single Phase BATTERY Full Load Runtime min 4 min 2700w Half Load Runtime min 11 min 1350w Expandable Battery Runtime Extended runtime supported via optional external battery packs External Battery Pack Compatibility BP72V15 2U limit 1 BP72V28RT 3U multi pack compatible BP72V18 2US multi pack compatible Expandable Runtime Description Some external battery configurations require the use of Tripp Lite s External Battery Configuration Software see manual for details Battery Recharge Rate Included Less than 3 hours recharge to 90 typical full load discharge Batteries Internal UPS Replacement Battery RBC96 3U Cartridge Battery Access Front panel battery access Battery Replacem
9. ving Features High efficiency economy mode operation Individually controllable load banks Schedulable daily hours of economy mode operation CERTIFICATIONS UPS Certifications Tested to UL1778 USA Tested to CSA Canada Meets FCC Part 15 Category A EMI ROHS Restriction of Hazardous Substances ENERGY STAR Qualified ARRANTY Product Warranty Period Worldwide 2 year limited warranty Connected Equipment Insurance U S Canada amp Puerto Rico 250 000 Ultimate Lifetime Insurance 2015 Tripp Lite All rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice Photos may differ slightly from final products 6 6
10. xtended runtime options available Interactive LCD interface reports UPS operating mode detailed UPS ates e Distributed Server Rooms and site power data plus enables a variety of UPS setup and configuration options Highly efficient operation in e Network Closets optional economy mode saves BTU heat output and energy costs Network management interfaces support e Small Business Networks communications via USB RS 232 contact closure and optional SNMPWEBCARD network interface Built in e Voice over IP VoIP Phone DB9 port offers both enhanced RS 232 data and basic contact closure monitoring ability HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac a OS X Includes PowerAlert monitoring software and complete cabling Emergency Power Off EPO interface Package Includes LED display reports UPS operating mode line power availability battery mode operation inverter operation e SU3000RTXLCD3U UPS System ECO mode status and output power availability Audible alarm with push button momentary alarm cancel and e PowerAlert Software with USB silent mode LCD configuration options Programmable self test Battery independent restart Fault tolerant Serial amp EPO cabling auto bypass mode Field replaceable hot swappable internal batteries and external battery packs e 4 post rackmount installation kit e Instruction manual Features e Tripp Lite SUZ000RTXLCD3U 3000VA 3kV