Home
Cisco Qlogic QLE2462 2-port 4GB FC
Contents
1. N2XX AEPCIO1 Emulex OCe10102 F The DS SFP FC8G SW optical module listed in Table 11 should be ordered only for the following PCle cards as they do not come by default with any optical modules N2XX AEPCIO5 Emulex LPe 12002 Dual Port 8 Gb Fibre Channel HBA 26 Cisco UCS C210 M2 General Purpose Rack Mount Server CONFIGURING the SERVER Figure 5 Network Card Connections Network PCle Card Optical SFP Modules Fiber Optic Cables ec 1E Sa gt ad E Redundant Top of Rack Access Switches Metwork PCle Card Twinax Copper Cables Redundant Top of Rack Access Switches Cisco UCS C210 M2 General Purpose Rack Mount Server 27 CONFIGURING the SERVER STEP 9 CHOOSE OPTIONAL DVD RW DRIVE An optional DVD RW optical drive with dual layer DL media support may be ordered The drive is listed in Table 12 Table 12 Available DVD RW Drive Product ID PID PID Description R210 ODVDRW DVD RW Drive for UCS C210 M2 Rack Servers 28 Cisco UCS C210 M2 General Purpose Rack Mount Server CONFIGURING the SERVER STEP 10 ORDER OPTIONAL REDUNDANT POWER SUPPLY The C210 M2 server can accommodate two power supplies Only one power supply is required One 650 W power supply ships with the base server chassis You can order an optional redundant power supply listed in Table 13s Table 13 Redundant Power Supply Product ID PID PID Description R2X0 PSU2 650W SB 650 W power supply w adde
2. ANNIN i Cordset rating 10 A 250 V Length 8 ft 2 in 2 5 m Connector C15M EN60320 C15 Plug Length 8 MP232 R TOT ON Cordset rating 10 A 250 V zt ft 2 in 2 5 m Connector IEC 60320 C15 ZL Cordset rating 10 Plug EL 210 13 BS 1363A 13 AMP fuse A 250 V 500 V MAX 7 N ad Length 2500mm Connector EL 701C EN 60320 C15 g 31 32 CONFIGURING the SERVER Table 14 Available Power Cords continued Product ID PID PID Description Images CAB 9K12A NA Power Cord 125VAC 13A NEMA Image not available 5 15 Plug North America CAB JPN 3PIN Power Cord 3PIN Japan Image not available Cisco UCS C210 M2 General Purpose Rack Mount Server CONFIGURING the SERVER STEP 12 ORDER TOOL LESS OPTIONAL RAIL KIT A rail kit is not included with the Cisco UCS C210 M2 base server chassis but you can order the tool less rail kit listed in Table 15 Table 15 Rail Kit Product ID PID PID Description R2XX G31032RAIL Rail Kit for UCS 200 210 Rack Servers NOTE This third generation rail kit works in racks with square holes or 10 32 round holes and is shorter than the previous generation rail kit The new R2XX G31032RAIL measures 23 5 inches to 36 inches in length By comparison the previous version R250 S
3. RAID Configuration note Mezzanine card supports only RAID 0 1 and 1E R2XX RAIDO R2XX RAID1 R2XX RAID5 R2XX RAID6 R2XX RAID10 Factory pre configured RAID striping option Enable RAID 0 Setting Requires a minimum of 1 hard drive Factory pre configured RAID mirroring option Enable RAID 1 Setting Requires exactly 2 drives with same size speed capacity Factory pre configured RAID option Enable RAID 5 Setting Requires minimum 3 drives of same size speed capacity Factory pre configured RAID option Enable RAID 6 Setting Requires minimum 4 drives of same size speed capacity Factory pre configured RAID option Enable RAID 10 Setting Requires an even number of drives minimum 4 drives of Same size speed capacity o 18 NOTE No RAID option can be chosen if you have one of the following configurations e A mix of SAS and SATA drives e No drives Cisco UCS C210 M2 General Purpose Rack Mount Server CONFIGURING the SERVER Approved Configurations 1 Integrated SATA RAID 0 1 controller m Choose none of the options listed in Table 6 In this case the integrated RAID 0 1 controller will be used 2 Optional RAID controller B Choose one of the RAID controllers options with or without battery backup listed in Table 6 3 Optional RAID configuration B Choose one of the RAID configuration options listed in Table 6 o Caveats NOTE If an optional RAID configuration is not ch
4. please check the Hardware Compatibility List at this URL http www cisco com en US products ps10477 prod technical reference list html 24 Cisco UCS C210 M2 General Purpose Rack Mount Server CONFIGURING the SERVER STEP 8 ORDER OPTIONAL NETWORK CARD ACCESSORIES Copper twinax cables and SFP optical modules may be ordered to support the two port network cards that are available with the server Choose Optional Twinax Cables Copper twinax cables are listed in Table 10 You can choose cable lengths of 1 3 5 7 or 10 meters The two longer cables 7 and 10 meters are active which means that they contain active components within the SFP housing to improve signal quality Table 10 Available Twinax Cables Product ID PID PID Description SFP H10GB CU1M 10GBASE CU SFP Cable 1 M SFP H10GB CU3M 10GBASE CU SFP Cable 3 M SFP H10GB CU5M 10GBASE CU SFP Cable 5 M SFP H10GB ACU7M 10GBASE CU SFP Cable 7 M SFP H10GB ACU10M 10GBASE CU SFP Cable 10 M Approved Configurations 1 Choose Up to Two Twinax Cables for Each Network Card Ordered m You may choose one or two twinax cables for each network card ordered The cables can be different lengths however you would normally order two cables of equal lengths to connect to the primary and redundant network switching equipment Caveats The twinax cables listed in Table 10 can be ordered only for the following PCle cards N2XX ACPCIO1 Cisco UCS P81E Virtual Interf
5. EN55022 Class A ICESOO3 Class A VCCI Class A EN61000 3 2 EN61000 3 3 KN22 Class A CNS13438 Class A EMC Immunity EN55024 CISPR24 EN300386 KN24 leerde Americas Headquarters Asia Pacific Headquarters Europe Headquarters Casco Systems Inc Cisco Systems USA Pte Lid Cisco Systems International BV Amsterdam san Jose CA singapore The Netherlands Cisco has more than 200 offices worldwide Addresses phone numbers and fax numbers are listed on the Cisco Website al www cisco com go olfices Cisco and the Cisco Logo are trademarks of Cisco Systems Inc and or its affiliates in the US and other countries A listing of Cisco s trademarks can be found af wwwciscocom go trademarks Third party trademarks mentioned are the property of their respective owners The use of the word partner does not imply a partnership relationship between Cisco and any other company 1005R 62 Cisco UCS C210 M2 General Purpose Rack Mount Server
6. or Intel Xeon 5500 series Nehalem CPUs m Intel 5520 chipset B Cache size of 4 8 or 12 MB Choose CPUs The available CPUs are listed in Table 3 Table 3 Available CPUs Intel Xeon Westmere EP x56xx Family Product D PD mes Freg Poue sre e Cores OM deret IM A01 X0117 X5675 3 06 95 12 6 6 4 GT s 1333 A01 X0102 X5670 2 93 95 12 6 6 4 GT s 1333 A01 X0105 X5650 2 66 95 12 6 6 4 GT s 1333 A01 X0109 E5640 2 66 80 12 4 5 86 GT s 1066 A01 X0120 E5649 2 53 80 12 6 5 86 GT s 1333 UCS CPU E5645 E5645 2 40 80 12 6 5 86 GT s 1333 A01 X0111 E5620 2 40 80 12 4 5 86 GT s 1066 A01 X0106 L5640 2 26 60 4 6 5 86 GT s 1333 A01 X0107 L5630 2 13 40 12 4 5 86 GT s 1066 A01 X0123 E5606 2 13 80 8 4 4 8 GT s 1066 A01 X0108 5609 1 86 40 12 4 4 8 GT s 1066 Notes 1 If higher or lower speed DIMMs are selected than what is shown in the table for a given CPU the DIMMs will be clocked at the lowest common denominator of CPU clock and DIMM clock For example Selecting lower speed DIMMs If you use an X5650 CPU which can support up to 1333 MHz DIMMs with 1066 MHz DIMMs the DIMMs will be clocked at the lower speed of 1066 MHz Selecting higher speed DIMMs If you use 1333 MHz DIMMs with an E5620 CPU which can support up to 1066 MHz DIMMs the DIMMS will be clocked at the lower speed of 1066 MHz 10 Cisco UCS C210 M2 General Purpose Rack Mount Server CONFIGURING the SERVER The available 5500 series CPUs are listed in Table 4 Ta
7. 8x5xNBD Onsite 8x5x4 Onsite 24x7x4 Onsite 24x7x2 Onsite NOTE Cisco does not offer a certified drive destruction service as part of this service Product ID PID CON UCMD7 R210WSFF CON UCMD8 R210WSFF CON UCSD1 R210WSFF CON UCSD2 R210WSFF CON UCSD3 R210WSFF CON UCSD4 R210WSFF CON UCSD5 R210WSFF CON UCSD6 R210WSFF CON UCSD7 R210WSFF CON UCSD8 R210WSFF CONFIGURING the SERVER Table 23 Drive Retention Service Options continued Service Description Mdb ld piis Service Level UCS Warranty Plus UC PLUS DR UCWD2 8x5x4 With Drive Retention UCWD3 24x7x4 UCWD4 24x7x2 UCWD5 8x5xNBD Onsite UCWD6 8x5x4 Onsite UCWD7 24x7x4 Onsite UCWD8 24x7x2 Onsite For more service and support information see the following URL Product ID PID CON UCWD2 R210WSFF CON UCWD3 R210WSFF CON UCWD4 R210WSFF CON UCWD5 R210WSFF CON UCWD6 R210WSFF CON UCWD7 R210WSFF CON UCWD8 R210WSFF http www cisco com en US services ps2961 ps10312 ps10321 Cisco UC Warranty Support DS pdf For a complete listing of available services for Cisco Unified Computing System see this URL http www cisco com en US products ps10312 serv group home html Cisco UCS C210 M2 General Purpose Rack Mount Server 43 OPTIONAL STEP ORDER RACK s OPTIONAL STEP ORDER RACK s The optional R42610 rack is available from Cisco for the C Series servers including the C210 M2 server This rack is a standard 19 inch rack and can be ordered with a
8. Saving Mode unless all DIMMs are low voltage DIMMs CPUs that have a maximum memory frequency less than 1333 MHz support low voltage DIMMs operating in Power Saving Mode only and do not support Performance Mode Cisco UCS C210 M2 General Purpose Rack Mount Server SUPPLEMENTAL MATERIAL Recommended Configurations Table 26 lists the recommended DIMM combinations for 1 and 2 socket CPU systems The DIMM combinations yielding the best performance are noted Table 26 Recommended DIMM Combinations CPU Socket 1 DIMM DIMM DIMM DIMM Bank 1 Bank 2 Bank 1 Bank 2 uum we ee ls See pee nsus we 2x8GB 2x8GB 3x4 GB 3x8 GB E 3x8GB 3x8 GB 3 x 8 GB 3 x 8 GB Notes 1 Best performance configuration Total Memory Size CPU Socket 2 8 GB 1 CPU 16 GB 2 CPUs 12 GB 1 CPU 24 GB 2 CPUs 16 GB 1 CPU 32 GB 2 CPUs 24 GB 1 CPU 48 GB 2 CPUs 32 GB 1 CPU 64 GB 2 CPUs 36 GB 1 CPU 72 GB 2 CPUs 48 GB 1 CPU 96 GB 2 CPUs 60 GB 1 CPU 120 GB 2 CPUs 64 GB 1 CPU 128 GB 2 CPUs 72 GB 1 CPU 144 GB 2 CPUs 96 GB 1 CPU 192 GB 2 CPUs Cisco UCS C210 M2 General Purpose Rack Mount Server DIMM Max Clock rate 1333 MHz 1333 MHz 1333 MHz 1066 MHz 1333 MHz 1333 MHz 1333 MHz 1333 MHz 1066 MHz 1333 MHz 1333 MHz 1066 MHz 1333 MHz 800 MHz 800 MHz 800 MHz 800 MHz Total DIMMs in System 6 121 12 12 12 12 12
9. a desired service listed in Table 21 Table 21 UCS Computing Support Service Product ID PID On Site Description CON UCS1 R210W NO UC Support 8X5XNBD CON UCS2 R210W NO UC Support 8X5X4 CON UCS3 R210W No UC Support 24x7x4 CON UCS4 R210W No UC Support 24x7x2 CON UCS5 R210W Yes UC Support 8X5XNBD CON UCS6 R210W Yes UC Support 8X5X4 CON UCSZ R210W Yes UC Support 24x7x4 CON UCS8 R210W Yes UC Support 24x7x2 Unified Computing Warranty Plus Service For faster parts replacement than is provided with the standard Cisco Unified Computing System warranty Cisco offers the Cisco Unified Computing Warranty Plus Service You can choose from several levels of advanced parts replacement coverage including onsite parts replacement in as little as two hours Warranty Plus provides remote access any time to Cisco support professionals who can determine if a return materials authorization RMA is required You can choose a service listed in Table 22 Table 22 UCS Computing Warranty Plus Service Product ID PID On Site Description CON UCW2 R210W No UC Warranty Plus 8x5x4 CON UCW3 R210W No UC Warranty Plus 24x7x4 CON UCW4 R210W No UC Warranty Plus 24x7x2 CON UCW5 R210W Yes UC Warranty Plus 8X5XNBD CON UCW6 R210W Yes UC Warranty Plus 8X5X4 CON UCW7 R210W Yes UC Warranty Plus 24x7x4 CON UCW8 R210W Yes UC Warranty Plus 24x7x2 Cisco UCS C210 M2 General Purpose Rack Mount Server 41 CONFIGURING the SERVER Unified Computing Drive
10. continued PID Description Product ID PID Red Hat Enterprise Linux RHEL 25 1G 1A RHEL 25 1G 3A RHEL 25 4G 1A RHEL 25 4G 3A RHEL 25 UG 1A RHEL 25 UG 3A RHEL HA 25 1A RHEL HA 25 3A RHEL RS 25 1A RHEL RS 25 3A RHEL SFS 25 1A RHEL SFS 25 3A BMC BMC 012 BMC SE 4C BMC SE 6C BMC SE 8C BMC SE 10C BMC AE 4C BMC AE 6C BMC AE 8C BMC AE 10C RHEL 2 Socket 1 Guest 1Yr Svcs Required RHEL 2 Socket 1 Guest 3Yr Svcs Required RHEL 2 Socket 4 Guest 1Yr Svcs Required RHEL 2 Socket 4 Guest 3Yr Svcs Required RHEL 2 Socket U Guest 1Yr Svcs Required RHEL 2 Socket U Guest 3Yr Svcs Required RHEL Option High Availability 2 Socket 1Yr Svcs Required RHEL Option High Availability 2 Socket 3Yr Svcs Required RHEL Option Resilient w Ha 2 Socket 1 Yr Svcs Required RHEL Option Resilient Storage w HA 2 Socket 3 Yr Svcs Reqd RHEL Option Scalable File System 2 Socket 1 Yr Svcs Required RHEL Option Scalable File System 2 Socket 1 Yr Svcs Required BMC BPPM Per Server BMC BladeLogic Standard Edition 4 Cores Support Required BMC BladeLogic Standard Edition 6 Cores Support Required BMC BladeLogic Standard Edition 8 Cores Support Required BMC BladeLogic Standard Edition 10 Cores Support Required BMC BladeLogic Advanced Edition 4 Cores Support Required BMC BladeLogic Advanced Edition 6 Cores Support Required BMC BladeLogic Advanced Edition 8 Cores Support Required BMC BladeLogic Standard Edition 10 Cores Support Required Nexus 1
11. eN er en mg T ie i kde YR E IE Nu in uH En z ee T Connector to server front panel DB 9 serial connector VGA connector for a monitor i Two port USB connector for a mouse and keyboard Cisco UCS C210 M2 General Purpose Rack Mount Server 57 SUPPLEMENTAL MATERIAL Motherboard USB Port The C210 M2 motherboard has a general purpose USB socket as shown in Figure 16 Figure 16 Motherboard USB Port f y Internal USB socket MR E p cs ER ax BLISTERS ETSI ta ta mm ta VA OE n ER va Wa NRI ON A Tm Wan CAS hu A 1A X ie rip N 58 Cisco UCS C210 M2 General Purpose Rack Mount Server TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Dimensions and Weight Table 29 UCS C210 M2 Dimensions and Weight Parameter Value Height 3 45 in 8 76 cm Width 17 39 in 44 17 cm Depth 28 35 in 72 01 cm Front Clearance 3 in 7 62 cm Side Clearance 1 in 2 54 cm Rear Clearance 6 in 15 24 cm Weight 50 70 lbs 23 kg Notes 1 The system weight given here is an estimate for a fully configured system and will vary depending on the number of peripheral devices and power supplies Power Specifications The general power specifications for the C210 M2 server are listed in Table 30 Table 30 UCS C210 M2 Power Specifications Description Specification AC input voltage 100 to 120 VAC nominal 200 to 240 VAC nominal Range 90 to 264 VAC AC input f
12. factory default SAS Extender installed You cannot mix SSD and HDD drive types m Battery backup option available see the battery backup PID section in this table B Factory configured RAID options RAID 0 1 5 6 10 see the RAID PIDs section in this table Cisco UCS C210 M2 General Purpose Rack Mount Server 17 CONFIGURING the SERVER Table 6 Available RAID Options continued Product ID PID R2XX PLOO3 PID Description LSI MegaRAID SAS 9261 81 RAID 0 1 5 6 10 m Takes up one of five available PCle slots must be installed in slot 4 B Supports up to eight internal SAS or SATA drives with the factory default SAS Extender installed You can mix SAS and SATA drive types but you cannot mix HDD and SSD drive types m Supports up to 16 internal SAS or SATA drives with the optional SAS Expander installed You can mix SAS and SATA drive types but you cannot mix HDD and SSD drive types m Includes 512 MB of write cache m Battery backup option available see the battery backup PID section in this table B Factory configured RAID options RAID 0 1 5 6 10 see the RAID PIDs section in this table RAID Battery Backup Option not available with mezzanine card R2XX LBBU2 Battery Backup CAUTION If one of your RAID cards is equipped with a AN battery backup unit BBU be aware that hof swapping the BBU is not supported Please perform a graceful shutdown of the server prior to replacing the BBU
13. only with the same type of card If desired select the SAS Expander listed in Table 7 Table 7 SAS Expander Product ID PID Description R210 SASXPAND SAS Pass Thru Expander srvr requiring 8 HDDs For more information about the SAS Expander and SAS Extender see SAS EXTENDER and SAS EXPANDER on page 52 20 Cisco UCS C210 M2 General Purpose Rack Mount Server CONFIGURING the SERVER STEP 6 CHOOSE HARD DISK DRIVES or SOLID STATE DRIVES The standard disk drive features are B 2 5 inch small form factor B Hot pluggable B Sled mounted Choose Drives The available drives are listed in Table 8 Table 8 Available Hot Pluggable Sled Mounted HDDs and SSDs Product ID PID PID Description sibi Capacity HDDs A03 D146GC2 146GB 6 Gb SAS 15K RPM SFF SAS 146 GB A03 D300GA2 300 GB 6 Gb SAS 10K RPM SFF HDD SAS 300 GB UCS HDD300GI2F105 300 GB 6 Gb SAS 15K RPM SFF HDD SAS 300 GB A03 D500GC3 500 GB 6 Gb SATA 7 2K RPM SFF SATA 500 GB A03 D600GA2 600 GB 6 Gb SAS 10K RPM SFF HDD SAS 600 GB UCS HDD900GI2F106 900 GB 6 Gb SAS 10K RPM SFF HDD SAS 900 GB A03 D1TBSATA 1 TB 6 Gb SATA 7 2K RPM SFF HDD SATA 1 TB SSDs UCS SSD100GI1F104 NEW 100GB SATA SSD SFF STEC SATA 100 GB Cisco UCS C210 M2 General Purpose Rack Mount Server 21 CONFIGURING the SERVER Approved Configurations 1 Integrated SATA RAID 0 1 controller B Select up to 4 SATA only drives listed in Table 8 You cannot mix HDD and SDD SATA drive types 2 L
14. processor see Table 5 on page 14 If you select DIMMs whose speeds are lower or higher than that shown in the tables suboptimal performance will result 12 Cisco UCS C210 M2 General Purpose Rack Mount Server CONFIGURING the SERVER STEP3 CHOOSE MEMORY The standard memory features are B DIMMs Clock speed 800 MHz 1066 MHz or 1333 MHz Ranks per DIMM 1 2 or 4 Operational voltage single voltage 1 5 V or dual voltage 1 35 V 1 5 V Registered B DDR3 ECC registered DIMMs RDIMMs supporting Intel SDDC B Memory is organized with three memory channels per CPU with up to two DIMMs per channel DPC as shown in Figure 4 Figure 4 C210 M2 Memory Organization Channel D Channel A Bank 1 Shot 2 Bank 2 ChannelE Channel B Bank 1 5lot 4 Bank 2 ChannelF Channelt Bank 1 Slot 6 3 memory channels per CPU up to 2 DIMMs per channel amm Bank mum Bank Cisco UCS C210 M2 General Purpose Rack Mount Server 13 CONFIGURING the SERVER Choose DIMMs and Memory Mirroring Choose the memory configuration and whether or not you want the memory mirroring option The available memory DIMMs and mirroring option are listed in Table 5 Q NOTE When memory mirroring is enabled the memory subsystem simultaneously writes identical data to two channels If a memory read from one of the channels returns incorrect data due to an uncorrectable memory er
15. 0 ampere A circuit breakers for groups of receptacles The effects of a tripped circuit are limited to a receptacle group Simply press a button to reset that circuit Cisco UCS C210 M2 General Purpose Rack Mount Server 55 56 SUPPLEMENTAL MATERIAL POWER SUPPLIES The C210 M2 can accommodate one or two 650 W power supplies A typical power supply is shown in Figure 14 Figure 14 C210 M2 Power Supply Cisco UCS C210 M2 General Purpose Rack Mount Server SUPPLEMENTAL MATERIAL KVM CABLE The KVM cable provides a connection into the server providing a DB9 serial connector a VGA connector for a monitor and dual USB ports for a keyboard and mouse With this cable you can create a direct connection to the operating system and the BIOS running on the server The KVM cable ordering information is listed in Table 28 Table 28 KVM Cable Product ID PID PID Description 37 1016 01 KVM Cable Figure 15 KVM Cable EE oe mad BS Toa m i M NEE u mm e c Iff f Tm Ad rm a no E i N Y es nl zm n i me ee EE m Ci nen ger UiT E m nn en a nnn U en d pn ee N c men ui an Y Wu m p EL m mM ng aim o rr en n E ur GE T en 3 ET NE M de EE ae Pr T3 S 5 Er arm Er a en l JIP EE AE Fb IN Lo EE 1 d F LI a e SN ar EST Pett ate a RE BM Et Dj opta En c EN M eg mf peen e i el A 1 Fi
16. 000V for Hyper V and vSphere N1K VSG UCS BUN N1K VLEM UCS 1 VSG VLEM UCS 1 UCS Director CUIC PHY SERV BM U CUIC PHY SERV U CUIC TERM Over half off N1K and VSG w purchase of UCS B C Series Nexus 1000V License Paper Delivery 1 CPU for bundles VSG License Paper Delivery 1 CPU for bundles Cisco Cloupia Resource Lic One Phy Server node bare metal Cisco Cloupia Resource Lic One physical Server node Acceptance of Cisco Cloupia License Terms Cisco UCS C210 M2 General Purpose Rack Mount Server 37 CONFIGURING the SERVER Table 18 OSs and Value Added Software for 2 CPU servers continued PID Description VMware 5 VMW VS5 STD 1A VMW VS5 STD 2A VMW VS5 STD 3A VMW VS5 STD 4A VMW VS5 STD 5A VMW VS5 ENT 1A VMW VS5 ENT 2A VMW VS5 ENT 3A VMW VS5 ENT 4A VMW VS5 ENT 5A VMW VS5 ENTP 1A VMW VS5 ENTP 2A VMW VS5 ENTP 3A VMW VS5 ENTP 4A VMW VS5 ENTP 5A VMW VC5 STD 1A VMW VC5 STD 2A VMW VC5 STD 3A VMW VC5 STD 4A VMW VC5 STD 5A UCS VMW TERMS 38 Product ID PID VMware vSphere 5 Standard for 1 Processor 1 Year Support Rqd VMware vSphere 5 Standard for 1 Processor 2 Year Support Rqd VMware vSphere 5 Standard for 1 Processor 3 Year Support Rqd VMware vSphere 5 Standard for 1 Processor 4 Year Support Rqd VMware vSphere 5 Standard for 1 Processor 5 Year Support Rqd VMware vSphere 5 Enterprise for 1 Processor 1 Year Support Rad VMware vSphere 5 Enterprise for 1 CPU 2 Yr Support Rad VMware vSphere 5 Enterpr
17. 49 SUPPLEMENTAL MATERIAL Configuration Samples The following figures show examples of how DIMMs are populated for 1 CPU and 2 CPU systems Figure 8 Example of 24 GB DIMM Memory Combinations with One CPU 4 GB DIMM B GB DIMM 50 Cisco UCS C210 M2 General Purpose Rack Mount Server SUPPLEMENTAL MATERIAL Figure 9 Example of 96 GB DIMM Memory Combinations with Two CPUs 16 GB DIMM 16 GB DIMM 16 GB DIMM 8 GB DIMM 8 GB DIMM Chan E ChanF Cisco UCS C210 M2 General Purpose Rack Mount Server 51 SUPPLEMENTAL MATERIAL SAS EXTENDER and SAS EXPANDER This server has two factory configurable options for the hard drive backplane connection B Standard SAS extender or B Optional SAS expander SAS Extender The SAS extender see Figure 10 is installed by default in the C210 M2 server Figure 10 SAS Extender 197658 The extender implements four mini SAS SFF 8087 cable connectors each of which provides a connection for up to four drives The extender supports connection for up to four drives when using the onboard RAID controller the LSI 1064E mezzanine card or the LSI MegaRAID SAS 9280 4i4e and up to 8 drives when using the LSI MegaRAID SAS 9261 81 MegaRAID card Q SAS Expander NOTE The SAS extender is field replaceable but you cannot upgrade from a SAS extender to a SAS expander in the field due to cable routing constraints You can replace an extender or expander o
18. 74 x 23 58 x 43 38 in 2000 x 599 x 1102 mm 89 x 33 x 47 in 2261 x 838 x 1194 mm 29 2 in 741 mm 231 49 lb 105 kg 284 lb 129 kg No 42RU 2100 lb 954 kg Not applicable o NOTE The AC input connector is an IEC 320 C 14 15 A 250 VAC power inlet Cisco UCS C210 M2 General Purpose Rack Mount Server 53 SUPPLEMENTAL MATERIAL Figure 12 Cisco R42610 Rack Front view door closed Front view door open Front view door removed 54 Cisco UCS C210 M2 General Purpose Rack Mount Server SUPPLEMENTAL MATERIAL PDUs Cisco RP Series Power Distribution Units PDUs offer power distribution with branch circuit protection Cisco RP Series PDU models distribute power to up to 24 outlets The architecture organizes power distribution simplifies cable management and enables you to move add and change rack equipment without an electrician With a Cisco RP Series PDU in the rack you can replace up to two dozen input power cords with just one The fixed input cord connects to the power source from overhead or under floor distribution Your IT equipment is then powered by PDU outlets in the rack using short easy to manage power cords The C series severs accept the zero rack unit ORU PDU See Figure 13 Figure 13 Zero Rack Unit PDU PID RP208 30 2P U 2 En Breakers En C19 plugs Cisco RP Series PDU models provide two 2
19. Assistance Center TAC Please note This service has qualification criteria Your company must have 1 2M of UCS equipment 200 blades and a single location to qualify for this service level Choose the desired service listed in Table 20 Table 20 Unified Computing Mission Critical Service Product ID PID On Site Description CON UCM7 R210W Yes UC Mission Critical 24x7x4 On site CON UCM8 R210W Yes UC Mission Critical 24x7x2 On site Unified Computing Support Service For support of the entire Unified Computing System Cisco offers the Cisco Unified Computing Support Service This service provides expert software and hardware support to help sustain performance and high availability of the unified computing environment Access to Cisco Technical Assistance Center TAC is provided around the clock from anywhere in the world For UCS blade servers there is Smart Call Home which provides proactive embedded diagnostics and real time alerts For systems that include Unified Computing System Manager the support service includes downloads of UCSM upgrades The Unified Computing Support Service includes flexible hardware replacement options including replacement in as little as two hours There is also access to Cisco s extensive online technical resources to help maintain Cisco UCS C210 M2 General Purpose Rack Mount Server CONFIGURING the SERVER optimal efficiency and uptime of the unified computing environment You can choose
20. Cisco UCS C210 M2 General Purpose Rack Mount Server 47 SUPPLEMENTAL MATERIAL Memory Population Rules When considering the memory configuration of your server you should consider the following items DIMMs within the server should all be the same type and speed If you mix different DIMM types or DIMMs with different clock rates in the same server such configurations are supported however these configurations may cause the system to operate at less than optimum levels See Table 26 on page 49 for recommended DIMM combinations DIMMs can be used either in a one DIMM per Channel 1DPC configuration or in a two DIMMs per Channel 2DPC configuration There are blue and black DIMM slots Populate blue slots in a bank first Low voltage 1 35 V DIMM and standard voltage DIMM 1 5 V can be mixed in the same server Note that this causes the system BIOS to default to standard voltage operation Performance Mode See Low Voltage DIMM Considerations Low Voltage DIMM Considerations The C210 M2 server can be ordered with low voltage 1 35 V DIMMs or standard voltage 1 5 V DIMMs Note the following considerations 48 Low voltage DIMMs within the server must have the identical manufacturer type speed and size Low voltage DIMMs and standard voltage DIMMs can be mixed in the same server Note that this causes the system BIOS to default to standard voltage operation Performance Mode That is the server cannot operate in Power
21. E PCle OPTION CARD S page 23 STEP 8 ORDER OPTIONAL NETWORK CARD ACCESSORIES page 25 STEP 9 CHOOSE OPTIONAL DVD RW DRIVE page 28 STEP 10 ORDER OPTIONAL REDUNDANT POWER SUPPLY page 29 STEP 11 CHOOSE AC POWER CORDS page 30 STEP 12 ORDER TOOL LESS OPTIONAL RAIL KIT page 33 STEP 13 ORDER OPTIONAL CABLE MANAGEMENT ARM page 34 STEP 14 ORDER A TRUSTED PLAT FORM MODULE page 35 STEP 15 CHOOSE OPERAT ING SYSTEM AND VALUE ADDED SOFTWARE page 36 STEP 16 CHOOSE OPERAT ING SYSTEM MEDIA KIT page 39 STEP 17 CHOOSE SERVICE and SUPPORT LEVEL page 40 OPTIONAL STEP ORDER RACK s on page 44 OPTIONAL STEP ORDER PDU on page 45 8 Cisco UCS C210 M2 General Purpose Rack Mount Server CONFIGURING the SERVER STEP1 VERIFY BASE SKU Verify the product ID PID of the base server as shown in Table 2 Table 2 PID of the Base C210 M2 Rack Server Product ID PID Description R210 2121605W UCS C210 M2 Srvr w 1PSU w o CPU mem HDD DVD or PCle card The R210 2121605W base server B Includes one power supply B Does not include CPU memory hard disk drives HDDs Solid State Drives SSDs plug in PCle cards or optional DVD RW drive Q NOTE Use the steps on the following pages to configure the server with the components that you want to include Cisco UCS C210 M2 General Purpose Rack Mount Server 9 CONFIGURING the SERVER STEP2 CHOOSE CPU S The standard CPU features are m Intel Xeon 5600 series Westmere EP
22. For example if you choose six DIMMs and select RAS Cisco UCS C210 M2 General Purpose Rack Mount Server 15 CONFIGURING the SERVER mirroring will eo into effect on only two channels with two DIMMS per channel you cannot implement RAS on three channels In this case two DIMMS would go unused o NOTE For memory mirroring DIMM pairing across buses must be identical If you only have two DIMMs they need to be the same PID because you have one DIMM on each of two buses If you have four DIMMs in a 2 CPU system for example you can have two 4 GB and two 8 GB DIMMs One 4 GB 8 GB DIMM pair would located on Channel A of CPU 1 and one 4 GB 8 GB DIMM pair would be located on Channel D of CPU 2 If you have four DIMMs in a 1 CPU system for example you can have two 4 GB and two 8 GB DIMMs One 4 GB 8 GB DIMM pair would located on Channel A of CPU 1 and one 4 GB 8 GB DIMM pair would be located on Channel B of CPU 1 For more information regarding memory see CPUs and DIMMs on page 47 16 Cisco UCS C210 M2 General Purpose Rack Mount Server CONFIGURING the SERVER STEP 4 CHOOSE RAID CONFIGURATION The base server motherboard comes with an integrated SATA RAID 0 1 controller which supports up to 4 SATA drives only the integrated controller does not support SAS drives Therefore a separate plug in PCle controller card is not required when ordering SATA drives and a RAID 0 or 1 configuration is desired You can use
23. IT i CISCO This product has been Spec Sheet discontinued Cisco UCS C210 M2 General Purpose Rack Mount Server Cisco SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR SAN JOSE CA 95134 REVA 15 JULY 16 2014 WWW CISCO COM CONTENTS OVERVIEW iii xad EN Ge EON CER ae ee Da ik DETAILED VIEWS 0e0 sk sk sk sk sk ak ai Chassis Front VIEW su ve ees RR RE EE CUR ce Wc i RR Sha SE ew 4 Chassis Rear View SS SS SS ns BASE SERVER STANDARD CAPABILITIES and FEATURES CONFIGURING the SERVER ses sak ask ase STEP 1 VERIFY BASE SKU lees STEP 2 CHOOSE CPU S aa STEP 3 CHOOSE MEMORY oane STEP 4 CHOOSE RAID CONFIGURATION aaan ene STEP 5 ORDER SAS EXPANDER AS NEEDED nen STEP 6 CHOOSE HARD DISK DRIVES or SOLID STATE DRIVES STEP 7 CHOOSE PCle OPTION CARD S aaan STEP 8 ORDER OPTIONAL NETWORK CARD ACCESSORIES STEP 9 CHOOSE OPTIONAL DVD RW DRIVE l l STEP 10 ORDER OPTIONAL REDUNDANT POWER SUPPLY STEP 11 CHOOSE AC POWER CORDS aaan STEP 12 ORDER TOOL LESS OPTIONAL RAIL KIT aan STEP 13 ORDER OPTIONAL CABLE MANAGEMENT ARM ee STEP 14 ORDER A TRUSTED PLATFORM MODULE lese STEP 15 CHOOSE OPERATING SYSTEM AND VALUE ADDED SOFTWARE STEP 16 CHOOSE OPERATING SYSTEM MEDIA KIT lessen STEP 17 CHOOSE SERVICE and SUPPORT LEVEL l l sees OPTIONAL STEP ORDER RACK s ea se ak ea ke ak aas 4G OPTIONAL STEP ORDER PDU si se s
24. LDRAIL measured 27 inches to 37 inches in length o See the section titled OPTIONAL STEP ORDER RACK s on page 44 for information about racks and rack equipment Cisco UCS C210 M2 General Purpose Rack Mount Server 33 CONFIGURING the SERVER 34 STEP 13 ORDER OPTIONAL CABLE MANAGEMENT ARM The cable management arm hooks onto the right and left slide rails at the rear of the server and is used for cable management You can order the cable management arm listed in Table 16 Table 16 Cable Management Arm Product ID PID PID Description R2XX CMAG3 1032 Cable Mgmt Arm for R2XX G31032RAIL for C200 C210 For more information about the cable management arm see the Cisco UCS C210 Installation and Service Guide at this URL http www cisco com en US docs unified_computing ucs c hw C210M1 install C210M1 html Cisco UCS C210 M2 General Purpose Rack Mount Server CONFIGURING the SERVER STEP 14 ORDER A TRUSTED PLATFORM MODULE Trusted Platform Module TPM is a computer chip microcontroller that can securely store artifacts used to authenticate the platform server These artifacts can include passwords certificates or encryption keys A TPM can also be used to store platform measurements that help ensure that the platform remains trustworthy Authentication ensuring that the platform can prove that it is what it claims to be and attestation a process helping to prove that a platform is trustworthy and has not
25. PCle Supplies slots 1 2 and 3 slots 4 and 5 F PCle riser card assembly e mimm c bom m m en id DIMMs Power Supply 82 Power Supply 1 Fan Iray 3 fans Front Panel Disk Drives 46 Cisco UCS C210 M2 General Purpose Rack Mount Server SUPPLEMENTAL MATERIAL CPUs and DIMMs Physical Layout Each CPU has three DIMM channels B CPU1 has channels A B and C B CPU2 has channels D E and F Each DIMM channel has two banks Bank 1 and Bank 2 The blue colored DIMM banks are for Bank 1 and the black colored DIMM banks are for Bank 2 As an example DIMM slots A1 B1 and C1 belong to Bank 1 while A2 B2 and C2 belong to Bank 2 Figure 7 shows how banks and channels are physically laid out on the motherboard The DIMM slots on the right channels A B and C are associated with CPU1 while the DIMM slots on the left channels D E and F are associated with CPU2 The Bank 1 blue DIMM slots are always located farther away from a CPU than the corresponding Bank 2 black slots Bank 1 slots are populated before Bank 2 slots If only one DIMM is used for CPU 1 for example it must be located in slot 2 A1 channel A bank 1 likewise if only one DIMM is used for CPU 2 it must be installed in slot 2 D1 channel D bank 1 Figure 7 CPU DIMM Channels and Banks C210 M2 Server Back Fl F2 El E DID2 A2 A1B2 B1C2 CI DIMM Module mm Bank Sockets blue EN Bank 2 Sockets black
26. Retention Service With the Cisco Unified Computing Drive Retention UCDR service you can obtain a new disk drive in exchange for a faulty drive without returning the faulty drive In exchange for a Cisco replacement drive you provide a signed Certificate of Destruction CoD confirming that the drive has been removed from the system listed is no longer in service and has been destroyed Sophisticated data recovery techniques have made classified proprietary and confidential information vulnerable even on malfunctioning disk drives The UCDR service enables you to retain your drives and ensures that the sensitive data on those drives is not compromised thereby reducing the risk of any potential liabilities This service also enables you to comply with regulatory local and federal requirements If your company has a need to control confidential classified sensitive or proprietary data you might want to consider one of the Drive Retention Services listed in Table 23 NE Table 23 Drive Retention Service Options Service Description UCS Mission Critical Support Service With Drive Retention UCS Support Service With Drive Retention 42 Service Program Name UC CRIT DR UC SUPP DR Service Level GSP UCMD7 UCMDS8 UCSD1 UCSD2 UCSD3 UCSD4 UCSD5 UCSD6 UCSD7 UCSD8 Cisco UCS C210 M2 General Purpose Rack Mount Server Service Level 24x7x4 Onsite 24x7x2 Onsite 8x5xNBD 8x5x4 24x7x4 24x7x2
27. SI 1064E 4 port SAS 6 0G RAID Mezzanine card RAID controller B Select up to four SAS or SATA drives listed in Table 8 You cannot mix HDD and SSD drives You cannot mix SAS and SATA drive types 3 LSI MegaRAID SAS 9280 4i4e RAID controller B Select up to four SAS or SATA internal drives listed in Table 8 for configurations with the factory default extender You cannot mix HDD and SSD drive types or SAS and SATA drives 4 LSI MegaRAID SAS 9261 8i RAID controller B Select up to eight internal SAS or SATA drives listed in Table 8 You can mix SAS and SATA drives but you cannot mix HDD and SSD drive types If you order the optional SAS Expander the controller can support up to 16 internal drives Caveats B If the integrated RAID controller on the server motherboard is used no PCle or mezzanine card controller selected all the drives must be SATA A SAS Extender is not field upgradable to a SAS Expander so if you are configuring a system with eight or more drives or anticipate the system will implement more than eight drives in the future make sure you order a SAS Expander You can replace an extender or expander only with the same type of card 22 Cisco UCS C210 M2 General Purpose Rack Mount Server CONFIGURING the SERVER STEP 7 CHOOSE PCle OPTION CARD S The standard PCle card offerings are B Fthernet B Fibre Channel m iSCSI B Virtual Interface Card VIC Choose PCle Option Cards The available PCle option car
28. Srvr 1 2 CPU 1 Phys SLES SVR 2S 1G 5A SUSE Linux Enterprise Srvr 1 2 CPU 1 Phys SLES SVR 2S UG 1A SUSE Linux Enterprise Svr 1 2 CPU Unl Vrt SLES SVR 2S UG 3A SUSE Linux Enterprise Svr 1 2 CPU Unl Vrt SLES SVR 2S UG 5A SUSE Linux Enterprise Svr 1 2 CPU Unl Vrt 1yr Support Reqd 3yr Support Reqd 5yr Support Reqd 1yr Support Reqd 3yr Support Reqd EE OE 5yr Support Reqd SLES SHA 2S 1A SUSE Linux High Availability Ext 1 2 CPU 1yr Support Reqd SLES SHA 2S 3A SUSE Linux High Availability Ext 1 2 CPU 3yr Support Reqd SLES SHA 2S 5A SUSE Linux High Availability Ext 1 2 CPU 5yr Support Reqd SLES HGC 2S 1A SUSE Linux GEO Clustering for HA 1 2 CPU 1yr Support Reqd SLES HGC 2S 3A SUSE Linux GEO Clustering for HA 1 2 CPU 3yr Support Reqd SLES HGC 2S 5A SUSE Linux GEO Clustering for HA 1 2 CPU 5yr Support Reqd SLES SAP 2S 1G 1A SLES for SAP Applications 1 2 CPU 1 Phys 1yr Support Reqd SLES SAP 2S 1G 3A SLES for SAP Applications 1 2 CPU 1 Phys 3yr Support Reqd SLES SAP 2S 1G 5A SLES for SAP Applications 1 2 CPU 1 Phys 5yr Support Reqd SLES SAP 2S UG 1A SLES for SAP Applications 1 2 CPU Unl Vrt 1yr Support Reqd SLES SAP 2S UG 3A SLES for SAP Applications 1 2 CPU Unl Vrt 3yr Support Reqd SLES SAP 2S UG 5A SLES for SAP Applications 1 2 CPU Unl Vrt 5yr Support Reqd 36 Cisco UCS C210 M2 General Purpose Rack Mount Server CONFIGURING the SERVER Table 18 OSs and Value Added Software for 2 CPU servers
29. ace Card 2 port 10Gbps UCS PCIE BSFP Broadcom 57712 N2XX ABPCIO2 Broadcom 57711 N2XX AEPCIO1 Emulex OCe10102 F N2XX AIPCIO1 Intel Dual Port Ethernet X520 N2XX AQPCIO1 Qlogic QLE 8152 CNA Cisco UCS C210 M2 General Purpose Rack Mount Server 25 CONFIGURING the SERVER Choose Optional SFP Modules Optical Cisco SFP modules are listed in Table 11 Table 11 Available SFP Modules Product ID PID PID Description SFP 10G SR 10GBASE SR SFP Module 850 nm multimode SR 3 3V LC connector with Digital Optical Monitoring DS SFP FC8G SW 8 Gbit SFP Module 850 nm multimode SR 3 3V LC connector with Digital Optical Monitoring Approved Configurations 1 Choose Up to Two SFP Modules for Each Network Card Ordered m You may choose one or two SFP optical modules cables for each network card ordered You would normally order two modules for connecting to the primary and redundant network switching equipment With the SFP optical modules you can use common fiber optic cables widely available See Figure 5 on page 27 for typical SFP and twinax connections to the network cards Caveats The SFP 10G SR optical module listed in Table 11 should be ordered only for the following PCle cards as they do not come by default with any optical modules N2XX ACPCIO1 Cisco UCS P81E Virtual Interface Card 2 port 10 Gbp UCSC PCIE BSFP Broadcom 57712 N2XX ABPCIO2 Broadcom 57711
30. appable hard disk drives HDDs or solid state drives SSDs m USB socket on motherboard Cisco UCS C210 M2 General Purpose Rack Mount Server BASE SERVER STANDARD CAPABILITIES and FEATURES Capability Feature Description Interfaces B Rear panel e One DB9 serial port connector e Two USB 2 0 port connectors e One DB15 VGA connector e Two RJ 45 10 100 1000 Ethernet port connectors e One RJ 45 10 100 Ethernet management port m Front panel e One KVM console connector Front Panel m Optional DVD RW optical drive with dual layer DL media support Power subsystem Up to two 650 W power supplies N 1 or nonredundant configuration options Fans Chassis B Three 80 mm redundant fans Power supply B Fach power supply is equipped with a fan Integrated management Cisco Integrated Management Controller CIMC with integrated video KVM processor redirection Security Intelligence Operations SIO fan speed control Platform Environment Control Interface PECI and voltage monitoring Cisco UCS C210 M2 General Purpose Rack Mount Server 7 CONFIGURING the SERVER CONFIGURING the SERVER Follow these steps to configure the Cisco UCS C210 M2 General Purpose Rack Server STEP 1 VERIFY BASE SKU page 9 STEP 2 CHOOSE CPU S page 10 STEP 3 CHOOSE MEMORY page 13 STEP 4 CHOOSE RAID CONFIGURATION page 17 STEP 5 ORDER SAS EXPANDER AS NEEDED page 20 STEP 6 CHOOSE HARD DISK DRIVES or SOLID STATE DRIVES page 21 STEP 7 CHOOS
31. assis Up to two quad core Intel Xeon 5500 or 5600 series processors Intel amp 5520 Tylersburg chipset 12 slots for registered ECC DIMMS up to 192 GB supporting Intel SDDC Embedded dual port Intel 82576NS PCle based Gigabit Ethernet controller Five PCle slots on a riser card B Slots 1 and 4 are full height full length x8 lane with a x16 connector B Slots 2 3 and 5 are full height half length x8 lane with a x16 connector One of the following B An onboard SATA RAID 0 1 controller integrated on motherboard Intel ICH10R that can control up to four SATA drives only or B An optional RAID mezzanine card e LSI 1064E 4 port controller mezzanine card RAID levels 0 1 or 1E for up to 4 internal SAS or SATA drives with the factory default SAS Extender or the optional SAS Expander installed or B One of these optional RAID PCle plug in cards installed in PCle slot 4 e LSI 6G MegaRAID SAS 9280 4i4e controller RAID levels 0 1 5 6 10 50 or 60 support for up to 4 internal SAS or SATA drives no mixing with the factory default SAS Extender plus external JBOD expansion or e LSI 6G MegaRAID SAS 9261 81 controller RAID levels 0 1 5 6 10 50 or 60 support for up to 8 internal SAS or SATA drives with the factory default SAS Extender or up to 16 SAS or SATA drives with a SAS Expander installed m 1280 x 1024 resolution m 32 bit color depth B 8 MB video memory B Up to 16 2 5 inch SAS or SATA hot sw
32. been breached are necessary steps to ensure safer computing in all environments The TPM ordering information is listed in Table 17 Table 17 Trusted Platform Module Product ID PID PID Description R200 TPM1 Trusted Platform Module Cisco UCS C210 M2 General Purpose Rack Mount Server 35 CONFIGURING the SERVER STEP 15 CHOOSE OPERATING SYSTEM AND VALUE ADDED SOFTWARE Several operating systems and value added software programs are available Select as desired from Table 18 Table 18 OSs and Value Added Software for 2 CPU servers PID Description Product ID PID Microsoft Windows Server MSWS 08R2 STHV Windows Svr 2008 ST media R2 ST 1 4CPU 5CAL MSWS 08R2 ENHV Windows Svr 2008 EN media R2 EN 1 8CPU 25CAL MSWS 08R2 DCHV2S Windows Svr 2008 R2 2 CPU Data Center MSWS 12 ST2S Windows Server 2012 Standard 2 CPU 2 VMs MSWS 12 DC2S Windows Server 2012 Datacenter 2 CPU Unlimited VMs MSWS 12 ST2S NS Windows Server 2012 Standard 2 CPU 2 VMs No Cisco SVC MSWS 12 DC2S NS Windows Server 2012 Datacenter 2 CPU Unlim VM No Cisco SVC MSWS 12R2 ST2S Windows Server 2012 R2 Standard 2 CPU 2 VMs MSWS 12R2 DC2S Windows Server 2012 R2 Datacenter 2 CPU Unlimited VMs MSWS 12R2 ST2S NS Windows Server 2012 R2 Standard 2 CPU 2 VMs No Cisco SVC MSWS 12R2 DC2S NS Windows Server 2012 R2 Datacen 2 CPU Unlim VM No Cisco Svc SUSE SLES SVR 2S 1G 1A SUSE Linux Enterprise Srvr 1 2 CPU 1 Phys SLES SVR 2S 1G 3A SUSE Linux Enterprise
33. ble 4 Available Intel CPUs Xeon Nehalem x55xx Family product D PID mu Freq PAST Se Cores GM OO DNA N20 X00001 X5570 2 93 95 8 4 6 4 GT s 1333 N20 X00006 X5550 2 66 95 8 4 6 4 GT s 1333 N20 X00002 E5540 2 53 80 8 4 5 86 GT s 1066 N20 X00003 E5520 2 26 80 8 4 5 86 GT s 1066 N20 X00004 5520 2 26 60 8 4 5 86 GT s 1066 N20 X00009 E5504 2 00 80 4 4 4 8 GT s 800 A01 X0113 E5506 2 13 80 4 4 4 8 GT s 800 Notes 1 If higher or lower speed DIMMs are selected than what is shown in the table for a given CPU the DIMMs will be clocked at the lowest common denominator of CPU clock and DIMM clock For example Selecting lower speed DIMMs if you use an X5570 CPU which can support up to 1333 MHz DIMMs with 1066 MHz DIMMs the DIMMs will be clocked at the lower speed of 1066 MHz Selecting higher speed DIMMs If you use 1333 MHz DIMMs with an E5506 CPU which can support up to 800 MHz DIMMs the DIMMS will be clocked at the lower speed of 800 MHz Cisco UCS C210 M2 General Purpose Rack Mount Server 11 CONFIGURING the SERVER Approved Configurations 1 Single CPU configurations B Choose any one CPU listed in Table 3 on page 10 or Table 4 on page 11 2 Two CPU Configurations B Choose two identical CPUs from any one of the rows of Table 3 on page 10 or Table 4 on page 11 Caveats m You can select either one processor or two identical processors B For optimal performance select DIMMs with the highest clock speed for a given
34. d 5A Standby for UCS C200 or C210 Cisco UCS C210 M2 General Purpose Rack Mount Server 29 CONFIGURING the SERVER STEP 11 CHOOSE AC POWER CORDS Select the appropriate AC power cords listed in Table 14 You may select a minimum of no power cords and a maximum of two power cords If you select the option R2XX DMYMPWRCORD no power cord is shipped with the server Table 14 Available Power Cords Product ID PID PID Description Images R2XX DMYMPWRCORD No power cord dummy PID to Not applicable allow for a no power cord option CAB N5K6A NA Power Cord 200 240V 6A North America i m iL CAB AC 250V 13A Power Cord NEMA L6 20 250V 20A plug IEC320 C13 receptacle North America ME ees et cane i Erato Tato Eese 2 CAB C13 C14 JMPR Power Cord recessed receptacle AC power cord 27 PO lil s o 250V SFS 250V 10A AR Power Cord SFS 250V 10A Argentina IN lt ma n pen rating 10 AL M ms EIE er IEC60320 C13 5 CAB 9K10A AU Power Cord 250VAC 10A 3112 Plug Australia EP c va UT d N N di LI Cordset rating 10 A 250 V 500 V MAX 7 SN ana N Length 2500mm M O Con
35. ds are listed in Table 9 Table 9 Available PCle Option Cards Product ID PID PID Description e Converged Network Adapters CNA N2XX ACPCIO1 Cisco UCS P81E Virtual Interface Card 2 port 10Gbps Full N2XX AEPCIO1 Emulex OneConnect OCe10102 F CNA 2 port 10Gbps Half UCSC PCIE BSFP Broadcom 57712 Dual Port 10Gb SFP w TOE iSCSI Half Network Interface Cards NICs N2XX ABPCIO2 Broadcom 57711 Dual Port 10GbE NIC w TOE iSCSI Half N2XX ABPCIO3 M3 Broadcom 5709 Quad Port 1Gb w TOE iSCSI for M3 Servers Half N2XX ABPCIO1 M3 Broadcom 5709 Dual Port 1Gb w TOE iSCSI for M3 Servers Half N2XX AQPCIO1 Qlogic QLE 8152 CNA 2port 10Gb SFP Copper Half N2XX AIPCIO2 Intel Quad port GbE Controller E1G44ETG1P20 Half N2XX AIPCIO1 Intel X520 Dual Port 10Gb SFP Adapter Half N2XX AMPCIO1 Mellanox ConnectX 2 EN with dual 10GbE SFP ports Half Host Bus Adapters HBAs N2XX AEPCIO3 Emulex LPe 11002 Dual Port 4Gb Fibre Channel HBA Half N2XX AEPCIO5 Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA Half N2XX AQPCIO3 Qlogic QLE2462 Dual Port 4Gb Fibre Channel HBA Half N2XX AQPCI05 Qlogic QLE2562 Dual Port 8Gb Fibre Channel HBA Half Cisco UCS C210 M2 General Purpose Rack Mount Server 23 CONFIGURING the SERVER Approved Configurations 1 No RAID controller plug in card B If you did not choose a plug in RAID controller for example you are using the mezzanine card or the interated RAID controller on the motherboard you can select up to five PCle option card
36. e SERVER 3 2 CPU configuration without memory mirroring B Choose from 1 to 6 DIMMs per CPU from 2 to 12 total DIMMs 4 2 CPU configuration with memory mirroring B Choose 2 4 6 or 8 DIMMs per CPU The DIMMs will be placed by the factory as shown in the following table Number of DIMM Placement DIMMs Channels C and F are not used with memory mirroring 2 CPU 1 1 DIMM in Channel A CPU 2 1 DIMM in Channel D 4 CPU 1 2 DIMMs in Channel A CPU 2 2 DIMMs in Channel D 6 CPU 1 CPU 2 2 DIMMs in Channel A 2 DIMMs in Channel D 1 DIMM in Channel B 1 DIMM in Channel E 8 CPU 1 CPU 2 2 DIMMs in Channel A 2 DIMMs in Channel D 2 DIMMs in Channel B 2 DIMMs in Channel E B Choose the memory mirroring option NO1 MMIRROR as shown in Table 5 on page 14 e NOTE System performance is optimized when the DIMM memory type and the DIMM NI quantity is equal for both CPUs Caveats B DIMM voltage You can mix dual voltage DIMMs operate at either 1 5 V or 1 35 V and single voltage DIMMs operate at only 1 5 V Dual voltage DIMMs can be operated in either of these modes e Power Saving Mode at a maximum speed of 1066 MHz e Performance Mode at a maximum speed of 1333 MHz If you mix both types of DIMMs in your configuration the server forces all DIMMs to operate in Performance Mode B Memory mirroring If you choose the Memory RAS option be aware that it is available only with an even number of memory channels
37. e sk ak sk ak rrr 9 SUPPLEMENTAL MATERIAL 0 0 ae sk enhn AO CHASSIS AREAS ER EER SE ER eee Ae wee BE EET EO TEEN a S 46 CPUS ANG DIMMS sos nEbE n ESE ADA a OO RS EE EED OE ees 47 PYVSICAULQVOUG 2259 3 99 OO OER ee gos UE eee d aca Ev d OE FEES 47 Memory Population Rules eee hs 48 Low Voltage DIMM Considerations eee ee ee ee eee hn 48 Recommended Configurations 0 cee eee eee et ee te hn 49 Configuration Samples eee ss ss ss SS hs 50 SAS EXTENDER and SAS EXPANDER celere eee eee 52 DAS EXEGHdel 45222 59442 955 ER RS AE ORE PA AA EDE ER EERS RE 52 SAS EXD NO wenskaarten ME SEE ERAS SHS DR RR ie d d 52 RACKS Denen 53 EER ET ETE OT EKG ee hee ee oe RE ee eee ON ee oe RT ewe ee 55 POWER SUPPLIES iis 6c hee dead eeeer se eee ew hee SONO NUUS S eee es eee IE 56 KYA CADLE peu eek ee oe ee TE EO BGs EE ee bee RE ee ee Se ae EE EIER EG 57 Motherboard USB Port sos sees ses ss ee eee eee m 9m 99 t mh 58 TECHNICAL SPECIFICATIONS ss cee ee RR as ea RR 99 Dimensions and Weight ss SS ss eee eee 59 Power Specifications ee ee te ss eee te ee 9 ee eee eee eee 59 Environmental Specifications 0 0 ss ss eee eee eee ene 61 Compliance Requirements 0 cc ec were ween eee 9 i s 62 Cisco UCS C210 M2 General Purpose Rack Mount Server OVERVIEW OVERVIEW The Cisco UCS C210 M2 server is a general purpose two
38. erating Vibration nonoperating Shock operating Shock nonoperating Electrostatic discharge Acoustic 10 C to 35 C 50 F to 95 F 40 C to 65 C 40 F to 149 F O to 3 000 m 0 to 10 000 ft maximum ambient temperature decreases by 1 per 300 m 5 to 93 noncondensing 2 2 Grms 10 minutes per axis on each of the three axes Half sine 2 G 11 ms pulse 100 pulses in each direction on each of the three axes Trapezoidal 25 G two drops on each of six faces Velocity 175 inches per second on bottom face drop Velocity 90 inches per second on the other five faces Tested to ESD levels up to 15 kilovolts kV air discharge and up to 8 kV contact discharge without physical damage Sound power 54 7 dBA 5 7 Bels at ambient temperature 23 C measured using the Dome Method GOST MsanPiN 001 96 Cisco UCS C210 M2 General Purpose Rack Mount Server 61 TECHNICAL SPECIFICATIONS Compliance Requirements The regulatory compliance requirements for C Series servers are listed in Table 32 Table 32 UCS C Series Regulatory Compliance Requirements Parameter Description Regulatory Compliance Products should comply with CE Markings per directives 2004 108 EC and 2006 95 EC Safety UL 60950 1 Second Edition CAN CSA C22 2 No 60950 1 Second Edition EN 60950 1 Second Edition IEC 60950 1 Second Edition AS NZS 60950 1 GB4943 2001 EMC Emissions 47CFR Part 15 CFR 47 Class A AS NZS CISPR22 Class A CISPR22 Class A
39. indows Server 2012 Datacenter 2 CPU Unlimited VM Rec Media Cisco UCS C210 M2 General Purpose Rack Mount Server 39 CONFIGURING the SERVER 40 STEP 17 CHOOSE SERVICE and SUPPORT LEVEL A variety of service options are available as described in this section Unified Computing Warranty No Contract If you have noncritical implementations and choose to have no service contract the following coverage is supplied B Three year parts coverage B Next business day NBD parts replacement eight hours a day five days a week m 90 day software warranty on media B Downloads of BIOS drivers and firmware updates HE UCSM updates for systems with Unified Computing System Manager These updates include minor enhancements and bug fixes that are designed to maintain the compliance of UCSM with published specifications release notes and industry standards Unified Computing Mission Critical Service This service delivers personalized technical account management expedited technical support and expert field support engineering for the Cisco Unified Computing System UCS The Mission Critical Support Service provides a designated technical account manager TAM who acts as a strategic resource to help ensure that the unified computing environment runs at peak efficiency If a problem arises that threatens business continuity the TAM provides crisis management leadership and your IT staff receives expedited access to Cisco s Technical
40. ise for 1 CPU 3 Yr Support Rad VMware vSphere 5 Enterprise for 1 Processor 4 Year Support Rad VMware vSphere 5 Enterprise for 1 CPU 5 Yr Support Rad VMware vSphere 5 Enterprise Plus for 1 Processor 1 Year Support Rqd VMware vSphere 5 Enterprise Plus for 1 CPU 2 Yr Support Rad VMware vSphere 5 Enterprise Plus for 1 Processor 3 Year Support Rqd VMware vSphere 5 Enterprise Plus for 1 Processor 4 Year Support Rqd VMware vSphere 5 Enterprise Plus for 1 Processor 5 Year Support Rqd VMware vCenter 5 Server Standard 1 yr support required VMware vCenter 5 Server Standard 2 yr support required VMware vCenter 5 Server Standard 3 yr support required VMware vCenter 5 Server Standard 4 yr support required VMware vCenter 5 Server Standard 5 yr support required Acceptance of Terms Standalone VMW License for UCS Servers Cisco UCS C210 M2 General Purpose Rack Mount Server CONFIGURING the SERVER STEP 16 CHOOSE OPERATING SYSTEM MEDIA KIT Choose the optional operating system media listed in Table 19 Table 19 OS Media Product ID PID RHEL 6 SLES 11 MSWS 08R2 STHV RM MSWS 08RS ENHV RM MSWS 08R2 DCHV RM MSWS 12 ST2S RM MSWS 12 DC2S RM PID Description RHEL 6 Recovery Media Only Multilingual SLES 11 media only multilingual Windows Svr 2008 R2 ST 1 4CPU 5CAL Media Windows Svr 2008 R2 EN 1 8CPU 25CAL Media Windows Svr 2008 R2 DC 1 8CPU 25CAL Media Windows Server 2012 Standard 2 CPU 2 VMs Recovery Media W
41. l layer DL media support optional Power button Power status LED CPU fault LED For more information regarding the KVM cable connection see KVM CABLE on page 57 Hard drives up to 16 2 5 HDD System fault LED Console connector with supplied KVM cable provides DB15 video DB9 serial and two USB 2 0 connectors 4 Cisco UCS C210 M2 General Purpose Rack Mount Server DETAILED VIEWS Chassis Rear View Figure 3 shows the external features of the rear panel Figure 3 Chassis Rear View 195912 a Power supply up to 2 5 Serial connector DB9 2 USB 2 0 connectors uM 10 100 1000 Megabit Ethernet ports 2 10 100 Ethernet management port RJ 45 Standard profile PCle card slots five total Slot Set sors PCle Slot Numbering rear server view Cisco UCS C210 M2 General Purpose Rack Mount Server 5 BASE SERVER STANDARD CAPABILITIES and FEATURES BASE SERVER STANDARD CAPABILITIES and FEATURES Table 1 lists the capabilities and features of the base server Details about how to configure the server for a particular feature or capability for example number of processors disk drives or amount of memory are provided in CONFIGURING the SERVER on page 8 Table 1 Capabilities and Features Capability Feature Chassis CPU Chipset Memory NIC Expansion slots Storage controller Video Internal storage devices Description Two rack unit 2RU ch
42. nector EL 701C EN 60320 C15 g BS sea d AME fuse 30 Cisco UCS C210 M2 General Purpose Rack Mount Server CONFIGURING the SERVER Table 14 Available Power Cords continued Product ID PID SFS 250V 10A CN CAB 9K10A EU SFS 250V 10A ID SFS 250V 10A IS CAB 9K10A IT CAB 9K10A SW CAB 9K10A UK Cisco UCS C210 M2 General Purpose Rack Mount Server PID Description Power Cord SFS 250V 10A China Power Cord 250VAC 10A CEE 7 7 Plug EU Power Cord SFS 250V 10A India Power Cord SFS 250V 10A Israel Power Cord 250VAC 10A CEI 23 16 VII Plug Italy Power Cord 250VAC 10A MP232 Plug Switzerland Power Cord 250VAC 10A BS1363 Plug 13 A fuse UK Images 7 gt der Plug EL 218 CCEE GB2009 Cordset rating 10A 250V 2500 mm LA Connector EL 701 e IEC60320 C13 ength ordset rating 10A 16 A 250 V m 8 ft 2 in 2 5 Plug EL 208 Cordset ratin 2500 mm 6 mg Cordset rating 16A 250V m ra 2500mm g 10A 250V 500V MAX E Connector IEC60320 C13 Plug 3G CEI 23 16 TUT LY
43. nly with the same type of card The SAS expander see Figure 11 may be optionally ordered for the C210 M2 server Figure 11 SAS Expander 197659 e NOTE The SAS expander is a factory configurable option in this server The NI expander is field replaceable The SAS Expander has two mini SAS SFF 8087 cable connectors One connector provides connection for up to 16 drives and the second connector provides redundancy 52 Cisco UCS C210 M2 General Purpose Rack Mount Server SUPPLEMENTAL MATERIAL RACKS The Cisco R42610 rack see Figure 12 is certified for Cisco UCS installation at customer sites and is suitable for the following equipment B Cisco UCS B Series servers and fabric interconnects B Cisco UCS C Series and select Nexus switches The rack is compatible with hardware designed for EIA standard 19 inch racks Rack specifications are listed in Table 27 Table 27 Cisco R42610 Rack Specifications Parameter Dimensions H x W x D Dimensions H x W x D with packaging Distance from front mounting rail to rear mounting rail Weight Weight with packaging Side panels included Equipment mounting capacity Static load capacity Dynamic load capacity Standard Rack 78 74 x 24 x 43 38 in 2000 x 610 x 1102 mm 89 x 33 x 47 in 2261 x 838 x 1194 mm 29 2 in 741 mm 299 83 lb 136 kg 354 lb 161 kg Yes 42RU 2100 lb 954 kg Not applicable Expansion Rack 78
44. osen the disks will be configured as a JBOD B The MegaRAID cards LSI MegaRAID SAS 9280 4i4e or LSI MegaRAID SAS 9261 8i must be installed in PCle slot 4 Refer to Figure 3 on page 5 for PCle slot numbering B If you choose the mezzanine RAID controller card you will still have all five PCle slots available for adding optional cards m The two optional plug in RAID controllers are each half height PCle cards If you choose one of these optional cards you will still have four slots available for adding optional PCle cards m You can choose only one RAID controller integrated controller mezzanine card controller or one plug in PCle controller B You can choose an optional RAID configuration RAID 0 1 5 6 or 10 which is pre configured at the factory If you do not choose a RAID configuration the disks will be configured as a JBOD Cisco UCS C210 M2 General Purpose Rack Mount Server 19 CONFIGURING the SERVER STEP 5 ORDER SAS EXPANDER AS NEEDED You must order a SAS Expander if the system will have more than eight disk drives or you plan to upgrade to over eight disk drives in the future If you do not select a SAS Expander the SAS Extender comes standard with the UCS C210 M2 server chassis The SAS Extender supports up to eight disk drives The SAS Extender option is not field upgradeable to a SAS Expander Both the SAS Extender and SAS Expander however are field replaceable You can replace an extender or expander
45. requency 50 to 60 Hz nominal Range 47 to 63 Hz Maximum AC input current 8 A at 100 VAC Maximum AC inrush current 30 A peak sub cycle duration Maximum output power for each 650W power supply Power supply output voltage Main power 12 VDC Standby Power 5 VDC Power supply efficiency 92 Peak complies with 80Plus Gold Standard Cisco UCS C210 M2 General Purpose Rack Mount Server 59 TECHNICAL SPECIFICATIONS o NOTE AC input connector is an IEC 320 C 14 15A 250VAC power inlet For configuration specific power specifications use the Cisco UCS Power Calculator at this URL http www cisco com assets cdc content elements flash dataCenter cisco ucs power calculator As an example using the calculator we can determine the approximate power for the following C210 M2 server configuration B Voltage 115 VAC Power Supplies 2 Processors 2 CPUs Intel Xeon 2 93 GHz X5670 Memory DIMMs 6 x 16 GB Disk Drives 16 x 1 TB PCle Cards 4 B PCle RAID Card 1 The resulting power calculations are m Idle Power 263 W m 50 Load Power 419 W B Max Power 574 W 60 Cisco UCS C210 M2 General Purpose Rack Mount Server TECHNICAL SPECIFICATIONS Environmental Specifications The power specifications for the C210 M2 server are listed in Table 31 Table 31 UCS C210 M2 Environmental Specifications Parameter Minimum Temperature operating Temperature nonoperating Altitude operating Humidity nonop
46. ror the system automatically retrieves the data from the other channel A transient or soft error in one channel does not affect the mirrored data and operation continues unless there is a simultaneous error in exactly the same location on a DIMM and its mirrored DIMM Memory mirroring reduces the amount of memory available to the operating system by 50 because only one of the two populated channels provides data Table 5 Available DDR3 DIMMs Product ID PID PID Description Voltage S DIMM Options UCS MR 1XO41RY A 4GB DDR3 1600 MHz RDIMM PC3 12800 1R dual voltage 1 35 1 5 V 1 UCS MR 1X082RY A 8GB DDR3 1600 MHz RDIMM PC3 12800 2R x4 dual voltage 1 35 1 5V 2 UCS MR 1X162RY A 16GB DDR3 1600 MHz RDIMM PC3 12800 2R x4 1 5v 1 35 1 5 V 4 Memory Mirroring Option NO1 MMIRROR Memory mirroring option Approved Configurations 1 1 CPU configuration without memory mirroring B Choose from one to six DIMMs note that there are six DIMM slots per CPU 2 1 CPU configuration with memory mirroring B Choose either two or four DIMMs The DIMMs will be placed by the factory as shown in the following table Number of DIMM Placement in Channels DIMMs Channel C is not used with memory mirroring 2 1 DIMM in Channel A 1 DIMM in Channel B 4 2 DIMMs in Channel A 2 DIMMs in Channel B B Choose the memory mirroring option NO1 MMIRROR as shown in Table 5 on page 14 14 Cisco UCS C210 M2 General Purpose Rack Mount Server CONFIGURING th
47. s listed in Table 9 2 One RAID controller plug in card B If you selected a plug in RAID controller you can select up to four of the optional PCle cards listed in Table 9 NOTE If a plug in RAID controller card is installed any optional PCle card you select will be installed in one of the remaining four PCle slots You can install a maximum of one plug in PCle RAID controller card Caveats B There are five PCle slots All are full height All of the PCle adapter cards are half height with the exception of the Virtual Interface Card VIC N2XX ACPCIO1 which is a full height card f you selected a plug in RAID controller in STEP 4 CHOOSE RAID CONFIGURAT ION four slots remain available Only a single Cisco UCS P81E Virtual Interface Card 2 port 10 Gb card may be installed and it must be installed in slot 1 or slot 2 Note however that if the server is running UCSM only slot 1 is supported for the VIC card See Figure 3 on page 5 for slot numbering e NOTE If you are using Unified Computing System Manager UCSM the Cisco UCS NI P81E Virtual Interface Card 2 port 10 Gb card must be installed only in PCle slot 1 All cards will fit in any slot B The MegaRAID cards LSI MegaRAID SAS 9280 4i4e or LSI MegaRAID SAS 9261 8i must be installed in PCle slot 4 Refer to Figure 3 on page 5 for PCle slot numbering B To help ensure that your operating system is compatible with the card you have selected
48. socket two rack unit 2RU rack server that builds on the success of the UCS C210 M1 server The UCS C210 M2 server shown in Figure 1 extends the capabilities of the Cisco Unified Computing System The server uses Intels latest Xeon 5600 Series multicore processors with 12 DIMM slots 5 PCle slots embedded dual port gigabit Ethernet controller and up to 16 2 5 inch SAS SATA hot swappable hard disk drives HDDs or solid state drives SSDs Figure 1 Cisco UCS C210 M2 High Density Rack Server Front View zE Lr jud jg dab hel j ril s uS PSP EI mi hel NH LU RT RT im We og m m M P a Ps L m mm m mu l Pia et a aS a a a a Ed i s Tarar P Ws Pu Srt a m M n pn Uu M LM tal E ii E D E Rear View up a oe rT T pou TINI i TREKT J Le d ESR ater TERENA lb EE 1 ze ET LLLI P N E ER Cisco UCS C210 M2 General Purpose Rack Mount Server DETAILED VIEWS DETAILED VIEWS Chassis Front View Figure 2 shows the Cisco UCS C210 M2 General Purpose Rack Server Figure 2 Chassis Front View i un EM Rz sf mn ET dd ae sm dad TE ree LEERS ee an n ER OENE TTE y Ee ee gg en ee a gn bab LLL LL se n e LU cL E b ns cs b s ED CIENT TERE eee E 55igE o Fere kaaa a jum EI zm DL is OO mnn crue EO MEM oo Locator LED Locator Button Network Activity LED Memory fault LED Power supply fault LED DVD RW drive with dua
49. the built in SATA RAID 0 1 controller as described in the preceding paragraph or you can instead choose to implement a RAID configuration by using the optional mezzanine card on the server motherboard or by using an optional plug in PCle RAID controller card Cisco can provide factory configured RAID 0 1 1E 5 6 and 10 systems depending on the RAID implementation chosen and the number of drives ordered Factory configured RAID options are listed at the end of Table 6 Note that RAID levels 50 and 60 are supported on the 9280 4i4e and 9261 81 but are not factory configurable Choose RAID Options Choose one RAID controller one RAID configuration option and if desired the battery backup option listed in Table 6 Table 6 Available RAID Options Product ID PID PID Description RAID Controllers R2X0 MLOO2 LSI 1064E 4 port SAS 3 0G RAID Mezzanine Card m installed on the mezzanine connector inside the UCS C210 M2 server B Supports up to four SAS or SATA drives with the factory default SAS Extender or the optional SAS Expander installed You cannot mix SSD and HDD drive types You cannot mix SAS and SATA drives B No battery backup B Factory configured RAID options RAID O 1 or 1E UCSC RAID C 414E LSI MegaRAID SAS 9280 4i4e four internal and four external ports m Takes up one of five available PCle slots must be installed in slot 4 B Supports up to 4 internal SAS or SATA drives no mixing plus external JBOD expansion with the
50. variety of options as listed in Table 24 Racks are shipped separately from the C210 M2 server 44 Table 24 Racks and Rack Options Product ID PID RACK UCS RACK UCS2 RACK BLANK 001 RACK CBLMGT 001 RACK CBLMGT 011 RACK FASTEN 001 RACK FASTEN 002 RACK JOIN 001 Notes PID Description Cisco R42610 expansion rack no side panels Cisco R42610 standard rack w side panels Filler panels qty 12 1U plastic toolless Cable mgt D rings qty 10 metal Cable mgt straps qty 10 Velcro Mounting screws qty 100 M6 Cage nuts qty 50 M6 Rack joining kit 1 Use these same base PIDs to order spare racks available only as next day replacements For more information about the R42610 rack see RACKS on page 53 Cisco UCS C210 M2 General Purpose Rack Mount Server OPTIONAL STEP ORDER PDU OPTIONAL STEP ORDER PDU An optional power distribution unit PDU is available from Cisco for the C Series rack servers including theC210 M2 server This PDU is available in a zero rack unit RU style see Table 24 Table 25 PDU Options Product ID PID PID Description RP208 30 2P U 2 Zero RU PDU For more information about the PDU see PDUs on page 55 Cisco UCS C210 M2 General Purpose Rack Mount Server 45 SUPPLEMENTAL MATERIAL SUPPLEMENTAL MATERIAL CHASSIS An internal view of the C210 M2 chassis with the top cover removed is shown in Figure 6 Figure 6 C210 M2 With Top Cover Removed PCle
Download Pdf Manuals
Related Search
Related Contents
Service Manual WFDS User Manual - Wildland Detection Systems Copyright © All rights reserved.
Failed to retrieve file