Liebert MPXIPC-NXD30XXX power cable

image

Contents

1. 73 MPX BRM Model Number Configuration Prefix MPXBRM Region N North America E European Type B Branch Monitoring R Receptacle Management E Elementary No Monitoring Size and OL Protection A Small 220mm B Standard 266mm C Standard w Tamper Proof Screws Output Power Voltage CB Rating A 120V 20A B 208V 20A C 230V 20A D 208 240V 20A E 100V 20A F 240V 20A Number of Receptacles 2 to 7 Receptacle Type A 5 20R F to L Reserved N IEC C13 Sheet F OZIEC C19 Sheet J P CEE 7 Type F Schuko U GST18 Phase Configuration 1N L1 N 2N L2 N 3N L3 N 12 L1 L2 23 L2 L3 31 L3 L1 Table 3 MPX BRM Branch Receptacle Module specifications Receptacle Ratings No of Voltage Length Weight Model Type Outlets Ampere A Voltage V OCB A Configuration mm Region Ib kg RECEPTACLE MANAGEMENT MODULES North American Applications MPXBRM NRBA6A1N NEMA 5 20R 6 16 120 20 L1 N 266 NA 2 3 1 03 MPXBRM NRBA6A2N NEMA 5 20R 6 16 120 20 L2 N 266 NA 2 3 1 03 MPXBRM NRBA6A3N NEMA 5 20R 6 16 120 20 L3 N 266 NA 2 3 1 03 MPXBRM NRBD4012 IEC C19 Sheet J 4 16 208 240 20 L1 2 266 NA 2 3 1 03 MPXBRM NRBD4023 IEC C19 Sheet J 4 16 208 240 20 L2 3 266 NA 2 3 1 03 MPXBRM NRBD4031 IEC C19 Sheet J 4 16 208 240 20 L3 1 266 NA 2 3 1 03 MPXBRM NRBD6N12 IEC C13 Sheet F 6 12 208 240 20 L1 2 266 NA 2 3 1 03 MPXBRM NRBD6N23 IEC C13 Sheet F
2. 12 3 1 4 Attach Brackets to a Knurr Miracel Horizontal Frame Member 12 3 1 5 Attach L Shaped Brackets to an Upright Frame Member of the Knurr Miracel m 3 2 Liebert MPX System Assembly 14 3 2 1 Attach an MPX or MPX to the MPX 14 3 2 5 Attach an MPX IPC to an MPX PEM Variable Capacity MPX Only North American Models Only 17 3 2 8 Install an Optional Liebert RPC in the MPX PEM North American Models Only 17 3 3 Temperature Humidity Sensor Installation Optional 18 3 4 Install an Optional RPCBDM in the Rack 19 39 41 MMountmg Hardware cece eus e exe ae g Sw a E UE e e 19 3 4 2 RPCBDM Installation on Knurr Miracel 19 4 0 SYSTEM FUNCTIONAL TEST hh 21 4 1 Checklist for Liebert MPX Assembly 21 4 2 Test the Liebert MPX s Functionality 21 5 0 OPERATION AND 22 1 Configure the Liebert RPG 26 2 54 cone pa v vA equ eR a gue 22 3ndicatorgo sede ee E eee etus tn a E ia ra far ur
3. 23 5 9 Operation With the Liebert RPC aA eeu s AU UOS nie t e es eee tracer tW bt e Ge 23 5 2 1 Connect to the Liebert RPC o rerit Er ehh 28 5 2 2 Viewing PDU and Receptacle Status PDU Explorer and Device Explorer 24 5 3 Operation Without the Liebert RPC 24 6 0 MAINTENANCE tama Loo ere a ag ieee PG AS i d past 25 6 1 Maintenance es 25 7 0 SPECIFICATIONS z uu does eraot ace Ren c SUO OR atc eee eae we 26 71 MPX PRC Model Number Configuration 26 72 PEM Model Number Configuration 27 73 MPX BRM Model Number Configuration 28 74 MPX IPC Model Number Configuration 30 7 5 Acency Approvalse ees oci pd P RR ete e ER et aree t e ito 31 8 0 DIMENSIONAL DRAWINGS L nueces Ro ne moe xa cle s Rec RR EE 32 9 0 RECYCLING INFORMATION FCC COMPLIANCE MODpIFICATIONS 34 FIGURES Figure 1 Liebert MPX assembly diagram 3 Figure2 MPX Power Rail Chassis components uu s 0 0 0 te eran wa a 5 Figure3 MPX PRC Power Rail Chassis T slots for mounting 5 Figure 4 MPX PEM Pow
4. 0 122 0 059 E 1 5mm 0 472 __ 12 0mm REAR VIEW DETAILA See Detail A 33 Recycling Information FCC Compliance Modifications 9 0 RECYCLING INFORMATION FCC COMPLIANCE MODIFICATIONS Notice to European Union Customers Disposal of Old Appliances This product has been supplied from an environmentally aware manufacturer that complies with the Waste Electrical and Electronic Equipment WEEE Directive 2002 96 CE This product uses components that are dangerous for the environment such as electronic cards and other electronic components Any component that is removed must be taken to specialized collection and disposal centers If this unit must be dismantled this must be done by a specialized center for collection and disposal of electric and electronics appliances or other dangerous substances The crossed out wheelie bin symbol at right is placed on this product to encourage you to recycle wherever possible Please be environmentally responsible and recycle this product through your recycling facility at its end of life Do not dispose of this product as unsorted municipal waste Follow local municipal waste ordinances for proper disposal provisions to reduce the environmental impact of waste electrical and electronic equipment WEEE For information regarding the scrapping of this equipment please browse http ww w eu emersonnetworkpower com Products or Contac
5. Real Energy 0 1kW hr Y V Power Factor 0 01 y y Crest Factor 0 01 y Frequency 0 1Hz Y 31 Dimensional Drawings 8 0 DIMENSIONAL DRAWINGS Figure 21 Liebert MPX assembly dimensions 1880mm 74 versions MPX PRC Cover Spacer 105 10 5 10 5 10 5 10 5 10 5 266mm 266mm T 266mm T 266mm 266 266mm 74 1880mm TOP VIEW 2 9 75 END VIEW MPX BRM MPX BRM MPX PEM Branch Receptacle Circuit Breaker Power Entry Modules Protection Body Module Sch MPX PRC SIDE VIEW Power Rail Chassis Figure 22 Liebert MPX assembly dimensions 1035mm 40 6 versions MPX PRC Cover Spacer 10 5 40 6 TOP VIEW MPX BRM MPX BRM MPX PEM Circuit Breaker Branch Receptacle Power Entry Input Power Protection Body Modules Module Cord A 104mm ON MPX PRC SIDEVIEW Power Rail os 2 9 4 1 104mm 75mm I Bum P 2 9 75mm 32 Dimensional Drawings Figure 23 RPCBDM dimensions Top Mounting Communication NT Slot M Connection 2 6 Rear eem V LCD 0 8 21mm Screen 4 4 5 116mm 1 1 29mm SIDE VIEW FRONT VIEW 0 787 e Mounting 20mm 0 063 Slot EL
6. Service D L5 30P F L6 30P G L21 20P H L21 30P I L22 30P J L15 30P K L14 20P L L14 30P M L7 30P Cord Length Length in meters two digits e g 30 3 0 meters Table 4 MPX IPC Input Power Cord specifications Input Ratings Length Model Ampere A Voltage V Service mm ft Region MPXIPC NXD30XXX 30 120 1 phase NEMA L5 30P 3 0 10 NA MPXIPC NXF30XXX 30 208 240 1 phase NEMA L6 30P 3 0 10 NA MPXIPC NXG30XXX 20 120 208 240 3 phase NEMA L21 20P 3 0 10 NA MPXIPC NXH30XXX 30 120 208 240 3 phase NEMA L21 30P 3 0 10 NA MPXIPC NXI30XXX 30 240 415 3 phase NEMA L22 30P 3 0 10 NA MPXIPC NXJ30XXX 30 208 240 3 phase NEMA L15 30P 3 0 10 NA MPXIPC NXK30XXX 20 120 208 240 2 phase NEMA L14 20P 3 0 10 NA MPXIPC NXL30XXX 30 120 208 240 2 phase NEMA L14 30P 3 0 10 NA MPXIPC NXM30XXX 30 240 1 phase NEMA L7 30P 3 0 10 NA 30 Specifications 7 5 Agency Approvals 120V and 240V Single Phase and 120 208 240V Three Phase North American Units UL60950 1 Information Technology Equipment Safety Part 1 General Requirements CSA C22 2 No 60950 1 Information Technology Equipment Safety Part 1 General Requirements FCC Title 47 Part 15 Subpart B for Class B operation as defined by ANSI Standard C63 4 ISTA Procedure 1A and 2A RoHS Compliant 230V Single Phase and 400V Three Phase European Units CE Markings GS mark safety tested according to DIN EN 60950 1 VBE 0805 1 2006 95 EC
7. adding modules will be hampered unless the space left is the size of a standard MPX BRM Decorative covers are available to reserve the proper space on the MPX PRC and to protect any unused sections of the unit s surface 15 Liebert MPX Installation and Assembly Figure 14 Liebert MPX assembled MPX N pOV Power Rail Chassis under modules MPX BRMs Branch Receptacle Modules Liebert RPC Rack PDU Card L ml I 4 MPX PEM Power Entry Module 16 Liebert MPX Installation and Assembly 3 2 2 Attach an MPX IPC to an MPX PEM Variable Capacity MPX PEM Only North American Models Only WARNING Risk of arc flash and electric shock Can cause equipment damage injury or death The MPX PEM contains hazardous voltage that could cause serious injury or death This unit must be properly and securely installed on the MPX PRC Power Rail Chassis Emerson strongly recommends that the MPX PEM be installed only by an individual who has been properly trained and qualified to perform electrical work Whenever the MPX 1s connected to power the connectors on the bottom are energized with hazardous voltage Connect input power only after the MPX PEM Power Entry Module is properly installed on the MPX PRC Power Rail Chassis the MPX IPC Input Power Cord is properly connected to the MPX PEM Conn
8. and EMC Directive EMD 2004 108 EC according to the Low Voltage Directive LVD CE Compliant according to Low Voltage Directive 2006 95 EC Electromagnetic Compatibility Directive 2004 108 EC EMD RoHS Directive 2002 95 EC WEE Directive 2002 96 EC ISTA Procedure 1 A and 2A ROHS and WEEE Compliant Basic Test for Purchased Products according to International Safe Transit Association Table 5 Electrical and environmental specifications 22 maximum per fully configured 420 model RPC PEM 6xBRM R Power Consumption W 3 per RPC 0 4 per module 0 4 per open control energized condition Maximum Ratings 240 415V 50 60Hz 63A Insulation Class Basic Earthed SELV Electric Strength VDC 2200 Overcurrent Protection UL489 Overcurrent Circuit Breaker per Branch 20A 5000A A I C Operating Temperature C F 5 55 41 131 Humidity 10 95 non condensing Altitude m ft 2000 6560 Table 6 Metering performance Volts V 1 2 from 1 to lt 10 Current A per rated value 1 from 10 to 125 Branch Receptacle Module BRM Measurement Resolution Power Entry Module PEM Branch Receptacle Phase Voltage 0 1V Line Voltage 0 1 Y Line Current 0 01A N N N Neutral Current 0 01A mM only Total Real Power 0 1W y Total Real Energy 0 1kW hr Y Real Power 0 1W y y Apparent Power 0 1VA
9. as the Knurr Miracel rack Figure3 MPX PRC Power Rail Chassis T slots for mounting This T slot the back of the MPX PRC Power Rail Chassis accepts spring nuts for easy mounting Liebert MPX System Modules 2 2 MPX PEM Power Entry Module Power Input A WARNING Risk of arc flash and electric shock Can cause equipment damage injury or death The MPX PEM contains hazardous voltage This unit must be properly and securely installed on the MPX PRC Power Rail Chassis The power conductors on the bottom of the MPX PEM are energized with hazardous voltage whenever the MPX PEM is attached to power If the MPX PEM is not installed on the MPX PRC these conductors will be exposed Emerson strongly recommends that the MPX PEM be installed only by an individual who has been properly trained and qualified to perform electrical work A WARNING Risk of connecting two MPX PEMs to one MPX PRC Can cause equipment damage injury or death Connect only one MPX PEM Power Entry Module to an MPX PRC Power Rail Chassis Connecting more than one MPX could cause cross conduction cross conduction can cause upstream overcurrent protective devices OCPD trip or the resulting short circuit current may exceed the OCPD A I C ratings The MPX PEM centralizes the connectivity of Liebert s MPX s power input and communication ports The MPX PEM securely fastens onto the MPX PRC Power Rail Chassis to deliv
10. assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions 2010 Liebert Corporation All rights reserved throughout the world Specifications subject to change without notice Liebert is a registered trademark of Liebert Corporation All names referred to are trademarks or registered trademarks of their respective owners S1 20820 REV3 07 12 Emerson Network Power The global leader in enabling Business Critical Continuity Technical Support Service Web Site www liebert com Monitoring liebert monitoring emerson com 800 222 5877 Outside North America 00800 1155 4499 Single Phase UPS amp Server Cabinets liebert upstech emerson com 800 222 5877 Outside North America 00800 1155 4499 Three Phase UPS amp Power Systems 800 543 2378 Outside North America 614 841 6598 Environmental Systems 800 543 2778 Outside the United States 614 888 0246 Locations United States 1050 Dearborn Drive P O Box 29186 Columbus OH 43229 Europe Via Leonardo Da Vinci 8 Zona Industriale Tognana 35028 Piove Di Sacco PD Italy 39 049 9719111 39 049 5841 257 Asia 29 F The Orient Square Building F Ortigas Jr Road Ortigas Center Pasig City 1605 Philippines 63 2 687 6615 Fax 63 2 730 9572 EmersonNetworkPower com AC Power Embedded Computing Outside Plant Racks amp Integrated Cabinets Connectivity Embedded Power Powe
11. factory configured for DHCP If you require a Static or BootP network En configuration be sure to change the Boot Mode as described below p 1 Insert an additional Ethernet cable not included into the Liebert RPC s Expansion Expansion Management port identified by the icon on the right Management port icon NOTE The Liebert RPC s Expansion Management port should be used ONLY for local configuration through interconnection to a computer or for interconnecting an additional Liebert MPX or Liebert MPH Insert the other end of the Ethernet cable into a computer Configure the computer s IP settings to communicate on a 192 168 1 X network go to IP address 192 168 1 9 Subnet mask 255 255 255 252 Default gateway 192 168 1 1 4 Toconnect to the card open a Web browser and enter http 192 168 1 10 into the URL field then press Enter 5 Once the Rack PDU Web page is displayed click the Configure tab then click Network Settings in the left pane 6 When prompted for a user name and password enter Liebert case sensitive for both NOTE Control and configuration capabilities are protected by a username and password combination After entering Liebert for both the startup default username and password change it in both places for better security Click OK 8 Click Edit in the right pane 9 The default Speed Duplex for the Ethernet port is Auto automatic To change this choose from the Spee
12. frame member The brackets must be directly in line with each other for the Liebert MPX to be installed 6 After the brackets are attached hang the Liebert MPX in the rack by inserting the Liebert MPX mounting screws into the slots on the brackets see Figure 12 7 Tighten the Liebert MPX mounting screws securely Figure 10 Attaching brackets to a horizontal frame member Z Shaped Bracket on Knurr Miracel Horizontal Frame Member L Shaped Bracket on Knurr Miracel Horizontal Frame Member 12 Liebert MPX Installation and Assembly 3 1 5 Attach L Shaped Brackets to an Upright Frame Member of the Knurr Miracel 1 2 7 Figure 11 Figure 12 Hang Liebert MPX on a bracket i Insert two spring nuts into the T slot on a rear upright frame member see Figure 11 Position the spring nuts to accommodate screws inserted through slots in the brackets To move the spring nuts press down on each with a small pointed object and slide each into position Hold an L shaped bracket in place and attach it with two of the M5x10 screws with hex heads Tighten the hex head screws firmly with the Allen wrench Repeat Steps 1 through 4 for the lower L shaped bracket The brackets will attach the Liebert MPX more securely if one is near the top of the unit and one is near the bottom After the brackets are attached hang the Liebert MPX in the rack by inserting the Liebert MPX mounting screws into the s
13. on each end a Use screwdriver to press each connector down The Integral Connectors on the MPX PEM have tamper resistant Torx heads Integral Connectors on the MPX BRM have PoziDriv heads however the same size Phillips head screwdriver can be used b Turn the screw until it locks and tightens about three quarters of a turn NOTE Do not overtighten the connector on either end cap Overtightening can damage the equipment Figure 13 Attach a module to the MPX PRC MPX BRM shown Integral Integral Connectors on the MPX BRM have Connector PoziDriv heads MPX PEM attaches locking end similarly except Integral Connectors on MPX PEM the MPX PEM have tamper resistant Torx heads Power Conductors Screwdriver depresses entering MPX PRC Integral Connector so 7 Power Bus the locking portion will fit into slot MPX PRC MPX PRC Communication Power Bus Bus Screw head will be flush with end cap Screws secure end when the Integral cap to MPX BRM Connector locks in Never remove these place screws t Integral Connector pressed into slot WARNING Risk of arc flash and electric shock Can cause equipment damage injury or death Do not remove the screws that affix the end cap Removing the end cap will expose energized parts with hazardous voltage 5 Repeat Steps 1 through 4 for each additional module NOTE Q The Liebert MPX will operate properly if spaces exist between modules but
14. receiver Connecting the equipment into an outlet on a circuit different from that to which the receiver is connected Seeking assistance from the local Emerson representative or an experienced radio TV technician Do Not Modify Users should be aware that this product must be assembled and operated as stated in this document Modifying the Liebert MPX or any module may void the user s authority to operate the equipment 34 Ensuring The High Availability Of Mission Critical Data And Applications Emerson Network Power a business of Emerson NYSE EMR is the global leader in enabling Business Critical Continuity from grid to chip for telecommunication networks data centers health care and industrial facilities Emerson Network Power provides innovative solutions and expertise in areas including AC and DC power and precision cooling systems embedded computing and power integrated racks and enclosures power switching and controls infrastructure management and connectivity All solutions are supported globally by local Emerson Network Power service technicians Liebert AC power precision cooling and monitoring products and services from Emerson Network Power deliver Efficiency Without Compromise by helping customers optimize their data center infrastructure to reduce costs and deliver high availability While every precaution has been taken to ensure the accuracy and completeness of this literature Liebert Corporation
15. serious injury or death from electric shock Read This Manual This manual contains important safety instructions Read all safety installation and operating instructions before installing a Liebert MPX Adhere to all warnings on the unit and in this manual Follow all operating and user instructions Observe all cautions and warnings in this manual Install in Appropriate Location The Liebert MPX must be installed in a restricted access location restricted access location is an area where access is possible only through the use of a tool or lock and key or other means of security and is controlled by the authority responsible for the location Operate the Liebert MPX in an indoor environment only within an ambient temperature range of 41 F to 131 F 5 C to 55 C with a relative humidity of 0 95 non condensing Install it in a clean environment free of conductive contaminants moisture flammable liquids gases and corrosive substances Qualified Personnel Only Emerson strongly recommends that the MPX PEM be installed only by an individual who has been properly trained and qualified to perform electrical work Only personnel who understand the precautions in this manual should be permitted in the Liebert MPX s restricted access location Not for Use in Safety Critical Applications The Liebert MPX is designed to deliver power to information technology and telecommunication equipment The Liebert MPX is not intended for us
16. the Liebert RPC Instructions for operating a Liebert MPX equipped with a Liebert RPC Rack PDU Card are more fully detailed in the card s user manual SL 20825 available at the Liebert Web site www liebert com Connect to the Liebert RPC After the Liebert RPC Rack PDU Card is installed and configured the card is ready to be used to monitor and manage the Liebert MPX as described below If the card is not installed and configured refer to 3 2 3 Install an Optional Liebert RPC in the MPX PEM North American Models Only and 5 1 Configure the Liebert RPC 1 Open a Web browser Liebert recommends using Microsoft s Internet Explorer and enter http 192 168 1 10 into the URL field then press Enter to display the Liebert MPX s Web page 2 When prompted for a user name and password enter Liebert case sensitive for both Control and configuration capabilities are protected by a username and password combination After entering Liebert for both the startup default username and password change both for security purposes refer to the user manual SL 20825 3 Access information about the Liebert MPX or configure the Liebert MPX by clicking on the appropriate tabs and viewing choices refer to the views in Figure 20 23 Operation and Configuration 5 2 2 Viewing PDU and Receptacle Status PDU Explorer and Device Explorer The PDU Explorer permits browsing components from the highest level of the Liebert MPX
17. up to three MPX BRMs Each size of MPX PRC also accepts a single MPX PEM The MPX PRC has five power bus slots that allow the connection of the MPX PEM and MPX BRM modules to three phases of power neutral and protective earth A communication bus provides the path through which the Liebert RPC MPX PEM and MPX BRM modules communicate The MPX PRC also has a module connector slot that permits secure attachment of MPX PEM and MPX BRM modules via their integral connectors Spacer covers are available to cap off unused sections of the MPX PRC s surface The spacer covers reserve positions to insert MPX BRMs for future expansion A WARNING Risk of connecting two MPX PEMs to one MPX PRC Can cause equipment damage injury or death Connect only one MPX PEM Power Entry Module to an MPX PRC Power Rail Chassis Connecting more than one MPX could cause cross conduction cross conduction can cause upstream overcurrent protective devices OCPD trip or the resulting short circuit current may exceed the OCPD A I C ratings Liebert MPX System Modules Figure2 MPX PRC Power Rail Chassis components Section of MPX PRC Power Bus Power Rail Chassis Communication Bus Module Connector Slot PRC1880 installed in Knurr Miracel 2 4 4 Mounting Features The back of the MPX PRC features T slots running the length of the unit These may be used for mounting the assembled units in racks such
18. 6 12 208 240 20 L2 3 266 NA 2 3 1 03 MPXBRM NRBD6N31 IEC C13 Sheet F 6 12 208 240 20 L3 1 266 NA 2 3 1 03 MPXBRM NRBF4012 IEC C19 Sheet J 4 16 240 20 L1 N 266 NA 2 3 1 03 MPXBRM NRBF4023 IEC C19 Sheet J 4 16 240 20 L2 N 266 NA 2 3 1 03 MPXBRM NRBF4031 IEC C19 Sheet J 4 16 240 20 L3 N 266 NA 2 3 1 03 MPXBRM NRBF6N12 IEC C13 Sheet F 6 12 240 20 L1 N 266 NA 2 3 1 03 MPXBRM NRBF6N23 IEC C13 Sheet F 6 12 240 20 L2 N 266 NA 2 3 1 03 MPXBRM NRBF6N31 IEC C13 Sheet F 6 12 240 20 L3 N 266 NA 2 3 1 03 RECEPTACLE MANAGEMENT MODULES European Applications MPXBRM ERBC3P1N Schuko CEE 7 4 3 16 230 20 L1 N 266 EU 2 3 1 03 MPXBRM ERBC3P2N Schuko CEE 7 4 3 16 230 20 L2 N 266 EU 2 3 1 03 MPXBRM ERBC3P3N Schuko CEE 7 4 3 16 230 20 L3 N 266 EU 2 3 1 03 MPXBRM ERBC401N IEC C19 Sheet J 4 16 230 20 L1 N 266 EU 2 3 1 03 MPXBRM ERBC402N IEC C19 Sheet J 4 16 230 20 L2 N 266 EU 2 3 1 03 MPXBRM ERBC403N IEC C19 Sheet J 4 16 230 20 L3 N 266 EU 2 3 1 03 MPXBRM ERBC6NI1N IEC C13 Sheet F 6 10 230 20 L1 N 266 EU 2 3 1 03 MPXBRM ERBC6N2N IEC C13 Sheet F 6 10 230 20 L2 N 266 EU 2 3 1 03 MPXBRM ERBCEN3N IEC C13 Sheet F 6 10 230 20 L3 N 266 EU 2 3 1 03 28 Specifications Table 3 MPX BRM Branch Receptacle Module specifications continued Receptacle Ratings No of Voltage Length Weight Model Type Outlets Ampere A Voltage V A Configuration mm Region Ib
19. AC Power For Business Critical Continuity Liebert MPX User Manual Global Applications gt EMERSON Network Power TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS hh hh 1 Save These Ins UG OHS a s dot e died ood OR alg suy Sort Sa pQ ws ah bee Se ee 1 1 0 LiEBERT MPX INTRODUCTION 3 2 0 LiEBERT MPX SYSTEM MODULES 4 2 1 MPX PRC Power Rail Chassis Power and Communication Bus 4 2 11 Mounting Features a a dete Soa ree e RR CR V RE REN ide re e eR os Ten 5 2 9 Power Entry Module Power Input 6 2 2 1 MPX IPC Input Power Cord Communication North American Models Only 7 2 3 MPX Receptacle Module Power Output 8 24 Liebert RPCTM Rack PDU Card 9 2 4 1 RPCBDM RPC Basic Display 10 3 0 LIEBERT MPX INSTALLATION AND ASSEMBLY 11 3 1 Installation in a Knurr MiracelRack 11 3 1 1 Mounting Hardware 1 11 3 1 2 Tools Required Field Supplied 11 3 1 3 Prepare the Liebert MPX for Mounting
20. Figure19 Liebert RPC PDU Explorer View d eee ee pK HEC RR ersten V e E REPE 24 Figure 20 Liebert RPC Device Explorer view 24 Figure 21 Liebert MPX assembly dimensions 1880mm 74 versions 32 Figure 22 Liebert MPX assembly dimensions 1035mm 40 6 versions 32 Figure 23 BPOBDM dimensions 33 TABLES Table 1 MPX PRC Power Rail Chassis 1 26 Table 2 MPX PEM Power Entry Module specifications 27 Table 3 MPX BRM Branch Receptacle Module specifications 28 Table 4 MPX IPC Input Power Cord 5 30 Table 5 Electrical and environmental specifications 31 Table 6 Metering performance ius yuyuman Qan lec WC ak 31 IMPORTANT SAFETY INSTRUCTIONS MPX Power Rail Chassis MPX PEM Power Entry Module MPX BRM Branch Receptacle Module MPX IPC Input Power Cord MPX RPC Rack PDU Card SAVE THESE INSTRUCTIONS A WARNING Risk of arc flash and electric shock Can cause equipment damage injury or death The Liebert MPX contains hazardous voltage Follow the warnings and cautions in this document to avoid
21. IPC Input Power Cord is properly connected to the MPX PEM Connect input power to the Liebert MPX only while the MPX IPC is properly connected to the MPX PEM Failure to do so may subject the user to hazardous voltages Tools Required Tamper resistant No 1 Torx screwdriver bit included with MPX PEM No 1 PoziDriv screwdriver bit included with MPX PEM No 1 Phillips screwdriver field supplied Before beginning to assemble the Liebert MPX Ensure that utility power is not connected to any module or component Ensure that no equipment 1s connected to the MPX BRM Branch Receptacle Module Ensure that the circuit breaker on the MPX BRM is Off After the MPX PRC Power Rail Chassis has been installed in the rack it is ready for attachment of an MPX PEM Power Entry Module and then the MPX BRMs Branch Receptacle Modules Emerson strongly recommends attaching the MPX PEM first positioning it at either end of the MPX PRC The module s position will not adversely affect operation but placing it at the end of the chassis will ease cable routing and separation of power and control cables in the rack Proper orientation of the MPX PRC is required to allow for the best use of the top or bottom entry into your rack If cables will enter through the top of the rack be sure that the MPX PRC has the power bus to the right side This will put the MPX PEM ina position where the input cord will be closest to the top of the rack If ca
22. L2 N 266 NA 2 3 1 03 MPXBRM NEBF7N31 IEC C13 Sheet F 7 12 240 20 L3 N 266 NA 2 3 1 03 29 Specifications Table 3 MPX BRM Branch Receptacle Module specifications continued Receptacle Ratings No of Voltage Length Weight Model Type Outlets Ampere A Voltage V A Configuration mm Region Ib kg ELEMENTARY MODULES European Applications MPXBRM EEBC3P1N Schuko CEE 7 4 3 16 230 20 L1 N 266 EU 2 3 1 03 MPXBRM EEBC3P2N Schuko CEE 7 4 3 16 230 20 L2 N 266 EU 2 3 1 03 MPXBRM EEBC3P3N Schuko CEE 7 4 3 16 230 20 L3 N 266 EU 2 3 1 03 MPXBRM EEBC4O1N IEC C19 Sheet J 4 16 230 20 L1 N 266 EU 2 3 1 03 MPXBRM EEBCAO2N IEC C19 Sheet J 4 16 230 20 L2 N 266 EU 2 3 1 03 MPXBRM EEBCAOS3N IEC C19 Sheet J 4 16 230 20 L3 N 266 EU 2 3 1 03 MPXBRM EEBC7N1N IEC C13 Sheet F 7 10 230 20 L1 N 266 EU 2 3 1 03 MPXBRM EEBC7N2N IEC C13 Sheet F 7 10 230 20 L2 N 266 EU 2 3 1 03 MPXBRM EEBC7N3N IEC C13 Sheet F 7 10 230 20 L3 N 266 EU 2 3 1 03 MPXBRM EEBC9U1N GST18 9 16 230 20 L1 N 266 EU 2 3 1 03 MPXBRM EEBC9U2N GST18 9 16 230 20 L2 N 266 EU 2 3 1 03 MPXBRM EEBC9U3N GST18 9 16 230 20 L3 N 266 EU 2 3 1 03 74 MPX IPC Model Number Configuration Prefix MPXIPC Region N North America E European Input Power and Connection Plug X attached N none
23. MPX EMERSON Network Power s Liebert MPX MPX PEN PEM ny PN RPC 1000 20 System Functional Test 4 0 SYSTEM FUNCTIONAL TEST 4 1 Checklist for Liebert MPX Assembly Follow these guidelines steps to verify that all components are properly assembled Failure to follow these steps and in the documented sequence could result in a serious injury or equipment damage 1 MPX Power Rail Chassis is securely attached to the rack 2 MPX PEM Power Entry Module is attached to the MPX PRC Ensure that the MPX is securely locked onto the MPX PRC 3 Power input cable is attached to the MPX PEM if applicable Variable Capacity models have detachable cables with quick connect couplings Fixed Capacity models have integral cables E Optional Liebert RPC Rack PDU Card is installed in the MPX PEM Z MPX BRM Branch Receptacle Modules are installed the number of modules that may be attached varies according to the length of the Power Rail Chassis Maximum electrical load is within values shown on the Liebert MPX module rating labels s The imput power supply ratings and connections match the specifications of the unit being installed 4 2 Testthe Liebert MPX s Functionality Perform these steps to determine whether the Liebert MPX is ready for use Failure to follow these steps In the documented sequence could result in serious injury or equipment damage 1 Ensure that all circ
24. PXBRM EBBC3P3N Schuko CEE 7 4 3 16 230 20 L3 N 266 EU 2 3 1 03 MPXBRM EBBC4O1N IEC C19 Sheet J 4 16 230 20 L1 N 266 EU 2 3 1 03 MPXBRM EBBCAO2N IEC C19 Sheet J 4 16 230 20 L2 N 266 EU 2 3 1 03 MPXBRM EBBC403N IEC C19 Sheet J 4 16 230 20 L3 N 266 EU 2 3 1 03 MPXBRM EBBCEN1N IEC C13 Sheet F 6 10 230 20 L1 N 266 EU 2 3 1 03 MPXBRM EBBC6N2N IEC C13 Sheet F 6 10 230 20 L2 N 266 EU 2 3 1 03 MPXBRM EBBCEN3N IEC C13 Sheet F 6 10 230 20 L3 N 266 EU 2 3 1 03 ELEMENTARY MODULES North American Applications MPXBRM NEBA6A1N NEMA 5 20R 6 16 120 20 L1 N 266 NA 2 3 1 03 MPXBRM NEBA6A2N NEMA 5 20R 6 16 120 20 L2 N 266 NA 2 3 1 03 MPXBRM NEBA6A3N NEMA 5 20R 6 16 120 20 L3 N 266 NA 2 3 1 03 MPXBRM NEBD4012 IEC C19 Sheet J 4 16 208 240 20 L1 2 266 NA 2 3 1 03 MPXBRM NEBD4023 IEC C19 Sheet J 4 16 208 240 20 L2 3 266 NA 2 3 1 03 MPXBRM NEBD4031 IEC C19 Sheet J 4 16 208 240 20 L3 1 266 NA 2 3 1 03 MPXBRM NEBD7N12 IEC C13 Sheet F 7 12 208 240 20 L1 2 266 NA 2 3 1 03 MPXBRM NEBD7N23 IEC C13 Sheet F 7 12 208 240 20 L2 3 266 NA 2 3 1 03 MPXBRM NEBD7N31_ IEC C13 Sheet F 7 12 208 240 20 L3 1 266 NA 2 3 1 03 MPXBRM NEBF4O412 IEC C19 Sheet J 4 16 240 20 L1 N 266 NA 2 3 1 03 MPXBRM NEBF4O23 IEC C19 Sheet J 4 16 240 20 L2 N 266 NA 2 3 1 03 MPXBRM NEBF4O31 IEC C19 Sheet J 4 16 240 20 L3 N 266 NA 2 3 1 03 MPXBRM NEBF7N12 IEC C13 Sheet F 7 12 240 20 L1 N 266 NA 2 3 1 03 MPXBRM NEBF7N23 IEC C13 Sheet F 7 12 240 20
25. bles will enter through the bottom of the rack be sure that the MPX PRC is oriented so that the power bus is to the left side This will put the MPX PEM in a position where the input cord will be closest to the bottom of the rack To balance the loads be sure that the installed MPX BRMs have more than one unique line configuration L1 L2 L2 L3 L3 L1 L1 N L2 N L3 N This will help to ensure that none of the phases is overloaded If the MPX PEM is a Variable Capacity model an MPX IPC input power cord is required Last an optional Liebert RPC rack PDU card can be installed 14 Liebert MPX Installation and Assembly Disconnect Loads Before Adding or Removing an MPX BRM During normal operation MPX BRMs Branch Receptacle Modules are hot swappable While adding or removing an MPX BRM no user loads can be connected to the MPX BRM Attempting to do so may damage the Liebert MPX or connected equipment To attach either the MPX PEM or a MPX BRM 1 Orient the module so that the power conducting tabs fit into the power bus on the MPX PRC and the communication contacts will fit into the MPX PRC s communication bus see Figure 13 2 Make sure that the integral connectors at each end of the module are oriented so they will fit into the slot on the MPX PRC Power Rail Chassis 3 Press the module firmly onto the MPX PRC 4 Secure the module to the Power Rail Chassis with the Integral Connectors there is one
26. can ease cable routing and help separate control and power cables to reduce electromagnetic interference A Liebert MPX can be installed in a Knurr Miracel rack on either the upright or horizontal frame member with the included hardware The unit can be installed on the face of the frame member or on the side of the frame member Installation requires inserting two spring nuts into the Liebert MPX screwing Liebert MPX mounting screws into the spring nuts and attaching two brackets to the Knurr Miracel frame members The Liebert MPX hangs on the brackets and is supported by the Liebert MPX mounting Screws A Risk of connecting two MPX PEMs to one MPX PRC Can cause equipment damage injury or death Connect only one MPX PEM Power Entry Module to an MPX PRC Power Rail Chassis Connecting more than one MPX could cause cross conduction cross conduction can cause upstream overcurrent protective devices OCPD trip or the resulting short circuit current may exceed the OCPD A I C ratings 3 1 4 Mounting Hardware Included Z shaped brackets 2 L shaped bracket 2 Spring nuts M5 6 Screws M5x10 6 Liebert MPX mounting screws 2 3 1 2 Tools Required Field Supplied Slotted screwdriver 4mm Allen wrench 11 Liebert MPX Installation and Assembly 3 1 3 Prepare the Liebert MPX for Mounting 1 Insert two spring nuts into the T slot on the back of the MPX one near either end see Fig
27. cle User Assigned Label ld State Receptacle 1 Receptacle 1 ESN BE Receptacle 2 ka Ta 5 3 Operation Without the Liebert RPC The Liebert MPX can be operated without the optional Liebert RPC rack PDU card but it will have reduced functionality After the unit is installed and assembled connect rack equipment to the receptacles connect input power and by switch on the circuit breaker on each MPX BRM Branch Receptacle Module Start the rack equipment according to the manufacturer s instructions 24 Maintenance 6 0 MAINTENANCE 6 1 The Liebert MPX needs little or no maintenance Emerson recommends setting up a maintenance schedule that includes Dust the unit s exterior with a clean dry cloth Check all fittings and connections to ensure they are tight If any fuses need replacing they must be replaced with the same type Maintenance Support The Liebert MPX contains no user serviceable parts If you need support or have questions about your Liebert MPX contact Emerson Network Power Distributed Processing Applications or your local Emerson representative Do not attempt to service this product yourself 25 Specifications 7 0 SPECIFICATIONS 7 1 MPX PRC Model Number Configuration Prefix MPXPRC Mounting V Vertical Length 1035 Short 40 3 4 1035mm 1880 Standard 74 1880mm Table 1 MPX PRC Power Rail Chassis specifications Maximum Mod
28. d Duplex drop down list 10 Choose the Boot Mode DHCP Static or BootP The default is DHCP 11 Click Save to save any changes or Reset to cancel A Notice window displays a reminder to reinitialize the card 12 Click OK 13 Make other changes as needed in the Configuration tab 14 To complete the configuration click Reinitialize in the left pane A Reinitialize button appears in the right side of the window 15 Click Reinitialize in the right pane to commit the changes and reboot the card The card is now fully operational 22 Operation and Configuration 5 1 1 5 2 5 2 1 Indicators NOTE Do not continue to use the Liebert MPX if the LED panel or monitoring interface indicators are not in accordance with these operating instructions Refer all faults to your local dealer Emerson representative or Emerson Distributed Processing Applications Engineering One or more Phase Power Indicators on the MPX PEM Power Entry Module should be green and lit but not flashing to indicate that input power is present and within tolerance If input power is 3 phase all three Phase Power Indicators should be lit green and if input power is single phase one Phase Power Indicator should be lit green Each MPX BRM should display a non repeated identifying number in the LED beside the circuit beaker If any MPX BRMs are receptacle management versions the LEDs beside the receptacles should be lit Operation With
29. d label EC C13 receptacle types are provided with retaining clips to provide strain relief for the load s power supply cord Liebert MPX System Modules Figure6 MPX BRM Branch Receptacle Module Receptacle On Off Indicators Receptacles Receptacle Management Units Only Branch Rated Circuit Breaker 100 Rated Integral Branch Numeric Connector Indicator 24 Liebert RPC Rack PDU Card The Liebert RPC centralizes local and remote management for the Liebert MPX It provides Web and SNMP management for systems connected to an Ethernet network The Liebert RPC also serves as the connection point for multiple support capabilities and devices including the RPC Basic Display Module RPCBDM various optional environmental sensors and sibling connection to other Liebert MPX or Liebert MPH systems The Liebert RPC is equipped with RJ 45 jacks for all connections and requires no custom cables The card supports 10 and 100 Mbit Ethernet and provides for in the field upgrade of firmware The Liebert RPC is user installed in a slot in the MPX PEM Power Entry Module Europe only The Liebert RPC is factory installed in all monitored MPX PEMs Figure7 Liebert RPC rack PDU card in an MPX PEM Power Entry Module RPCBDM port External Expansion Management port Sensor port LAN 120 208 gt 24 WARNING SHOCK HAZARD Connect mains power only
30. e with life support or other designated critical devices If uncertain about its application consult your local dealer or your Emerson representative Install MPX PEM Before Connecting Power Whenever the MPX PEM is connected to power the connectors on the bottom are energized with hazardous voltage Connect input power only after the MPX PEM Power Entry Module is properly installed on the MPX PRC Power Rail Chassis the MPX IPC Input Power Cord is properly connected to the MPX PEM Disconnect power before unlocking the connector screws that attach the PEM to the PRC Never remove a PEM from the power distribution unit while input power is connected The PEM is not hot swappable Only one MPX PEM Power Entry Module should be connected to an MPX PRC Power Rail Chassis Failure to comply could result in serious injury or equipment damage Do Not Open Covers or Insert Objects Never open or remove the cover of any Lieberte MPX module with exception of the Liebert RPC cover on the MPX module Never insert any foreign object into a Liebert MPX particularly into the power bus Never insert any foreign object into an MPX PEM An exception is that the MPX RPC provides a small hole between the display and sensor RJ 45 connectors to reset the card See Figure 4 to find the hole location Do Not Service Liebert MPX modules contain no user serviceable parts If you need support or have questions about your Liebe
31. ect input power to the Liebert MPX only while the MPX IPC is properly connected to the MPX PEM Failure to do so may subject the user to hazardous voltages Variable Capacity MPX PEM Power Entry Module versions require an MPX IPC input power cord to connect to utility power The MPX IPC is available with various input plugs for single phase or 3 phase and up to 30A Quick connect couplings are attached to the MPX IPC to ease proper connection to the MPX PEM Power Entry Module The connectors fit only one way mating the proper input ground and neutral wires on the power cord to the MPX PEM To attach the MPX IPC to an MPX PEM 1 Ensure that utility power is not connected to any module or component 2 Ensure that the MPX IPC is not connected to utility power 3 Insert the quick connect coupling on the MPX IPC into the connector on the MPX PEM It will lock into place Tug on the cord to determine whether it is securely attached to the MPX Figure 15 Quick connect couplings on MPX IPC input power cord and MPX PEM Power Entry Module 3 2 3 Quick connect Coupling on MPX IPC Quick Connect Couplings on MPX PEM Install an Optional Liebert RPC in the MPX PEM North American Models Only Installing a Liebert RPC rack PDU card in the MPX PEM Power Entry Module permits monitoring a Liebert MPX either over a network or with an MPX basic display module For complete details refer to the Liebert RPC u
32. er Entry Module features 7 Fisure b MPX IPC connector aa a a upa C td m ee Oras be fe ere s Y 7 Figure6 MPX BRM Branch Receptacle Module 9 Figure 7 Liebert RPC rack PDU card in an MPX Power Entry Module 9 Figure 8 RPCBDM J 7 ya a ulla 04 retos auos ediderat t ee tad dde edu eee A dei deg 10 Figure 9 Inserting a spring nut into a T slot and attaching an MPX mounting screw 12 Figure 10 Attaching brackets to a horizontal frame member 12 Figure 11 Attaching brackets to an upright frame 13 Figure 12 Hang Liebert MPX abracket 13 Figure 13 Attach a module to MPX PRC 15 Figure 14 Liebert MPX assembled 16 Figure 15 Quick connect couplings on MPX IPC input power cord and MPX PEM Power Entry T Sanga an pis Aiakas Su Gor as A at el 17 Figure 16 Temperature humidity sensor mounting 18 Figure 17 RPCBDM installation in rack sn h au au cc wawawa eh s 19 Figure 18 RPCBDM cable connection port on Liebert RPC 20
33. er polyphase power from its power supply cord to the power bus The Liebert RPC is installed in the MPX PEM for its operating power and connection to the communication bus The MPX PEM is available in North American models with Variable Capacity or Fixed Capacity and in European models with Fixed Capacity only Both configurations power supply cords are available in a variety of single and three phase NEMA Schuko and IEC plug styles and ratings The Variable Capacity models require connection of a detachable MPX IPC See 2 2 1 MPX IPC Input Power Cord Communication North American Models Only to its power inlet The power input ratings are determined by the plug type The user may change the MPX IPC with a different plug type and ratings from single phase to three phase to suit his her needs Up to 30 24 phase is supported uariable capacity North American models 32 per phase is supported for European models NOTE Up to 60A 48A per phase is supported for fixed capacity North American models up to 63A per phase is supported for European models All models except Elementary versions provide power metering of the polyphase inputs including individual line voltage and current total kW and total kWH Additionally individual line current alarming and operational status are supported Elementary models of the MPX PEM are available only in Europe Elementary models are not equip
34. gs Strain Relief Service S Straight Weight Model Capacity Ampere Voltage Phase Length mm R Right Angle Ib kg North American Applications MPXPEM NVAXXAXX Variable 30 24 120 208 240 1 3 220 S 2 3 1 03 MPXPEM NHBXRF30 Fixed 30 24 208 240 1 266 R 2 3 1 03 Fixed 30 24 240 415 3 266 s 2 3 1 03 MPXPEM NHBXXH30 Fixed 30 24 120 208 240 3 266 s 2 3 1 03 MPXPEM NHBXRH30 Fixed 30 24 120 208 240 3 266 R 2 3 1 03 MPXPEM NHBXXM30 Fixed 30 24 240 1 266 s 2 3 1 03 MPXPEM NHBXXW30 Fixed 60 48 120 208 240 3 266 s 2 3 1 03 MPXPEM NHBXRW30 Fixed 60 48 120 208 240 3 266 R 2 3 1 03 MPXPEM NHBXXX30 Fixed 60 48 208 240 3 266 S 2 3 1 03 MPXPEM NHBXRX30 Fixed 60 48 208 240 3 266 R 2 3 1 03 MPXPEM NHBXXV30 Fixed 50 40 208 240 3 266 S 2 3 1 03 MPXPEM NHBXRV30 Fixed 50 40 208 240 3 266 R 2 3 1 03 European Applications MPXPEM EHAAXQ30 Fixed 32 230 1 220 S 2 3 1 03 MPXPEM EHAEXQ30 Fixed 32 230 1 220 S 2 3 1 03 MPXPEM EHAAXR30 Fixed 32 230 400 3 220 S 2 3 1 03 MPXPEM EHAEXR30 Fixed 32 230 400 3 220 S 2 3 1 03 MPXPEM EHAAXS30 Fixed 16 230 1 220 S 2 3 1 03 MPXPEM EHAEXS30 Fixed 16 230 1 220 S 2 3 1 03 MPXPEM EHAAXT30 Fixed 16 230 400 3 220 s 2 3 1 03 MPXPEM EHAEXT30 Fixed 16 230 400 3 220 s 2 3 1 03 MPXPEM EHBAXZ30 Fixed 63 230 400 3 266 s 2 3 1 03 MPXPEM EHBEXZ30 Fixed 63 230 400 3 266 s 2 3 1 03 27 Specifications
35. in the following versions and features Elementary version provides power distribution only Power metering and alarming are not supported Branch Monitoring version of the MPX BRM provides power distribution and branch power metering including voltage current kW kVA kW h and power factor Receptacle Management version of the MPX BRM provides the same features as the Branch Monitoring models plus power metering including crest factor On Off control current alarming and operational status of individual receptacles The receptacles may either be turned On or Off remotely or programmed for automatic power on sequencing Other important features include An alphanumeric indicator to provide module identification and operational status not Elementary models of the branch current condition Additionally the Branch Monitoring version provides current alarming and operational status of the branch The unit displays an o for an overcurrent condition and a u for an undercurrent condition For Receptacle Management versions a visual indicator per receptacle alerts the user to the current condition of the load not Elementary models The circuit breaker may be opened with the use of a tool Open circuit breaker detection causes the alphanumeric indicator to flash not Elementary models Voltage phasing is determined by the power blade configuration on the bottom of each MPX and is clearly marked on the color code
36. kg BRANCH MONITORING MODULES North American Applications MPXBRM NBBA6A1N NEMA 5 20R 6 16 120 20 L1 N 266 NA 2 3 1 03 MPXBRM NBBA6A2N NEMA 5 20R 6 16 120 20 L2 N 266 NA 2 3 1 03 MPXBRM NBBA6A3N NEMA 5 20R 6 16 120 20 L3 N 266 NA 2 3 1 03 MPXBRM NBBD4012_ IEC C19 Sheet J 4 16 208 240 20 L1 2 266 NA 2 3 1 03 MPXBRM NBBD4023 IEC C19 Sheet J 4 16 208 240 20 L2 3 266 NA 2 3 1 03 MPXBRM NBBDA4O31 IEC C19 Sheet J 4 16 208 240 20 L3 1 266 NA 2 3 1 03 MPXBRM NBBD6N12 IEC C13 Sheet F 6 12 208 240 20 L1 2 266 NA 2 3 1 03 MPXBRM NBBD6N23 IEC C13 Sheet F 6 12 208 240 20 L2 3 266 NA 2 3 1 03 MPXBRM NBBD6N31_ IEC C13 Sheet F 6 12 208 240 20 L3 1 266 NA 2 3 1 03 MPXBRM NBBF4012 IEC C19 Sheet J 4 16 240 20 L1 N 266 NA 2 3 1 03 MPXBRM NBBF4O23 IEC C19 Sheet J 4 16 240 20 L2 N 266 NA 2 3 1 03 MPXBRM NBBF4O31 IEC C19 Sheet J 4 16 240 20 L3 N 266 NA 2 3 1 03 MPXBRM NBBF6N12 IEC C13 Sheet F 6 12 240 20 L1 N 266 NA 2 3 1 03 MPXBRM NBBF6N23 IEC C13 Sheet F 6 12 240 20 L2 N 266 NA 2 3 1 03 MPXBRM NBBF6N31 IEC C13 Sheet F 6 12 240 20 L3 N 266 NA 2 3 1 03 BRANCH MONITORING MODULES European Applications MPXBRM EBBC3P1N Schuko CEE 7 4 3 16 230 20 L1 N 266 EU 2 3 1 03 MPXBRM EBBC3P2N Schuko CEE 7 4 3 16 230 20 L2 N 266 EU 2 3 1 03 M
37. lots on the brackets see Figure 12 Tighten the Liebert MPX mounting screws securely Attaching brackets to an upright frame member L Shaped Bracket on Knurr Miracel Upright Frame Member MPX mounting screw fits MJ through the center of the bracket and slips into a slot The lower screw on the back of the MPX PRC will sit in the bottom of the middle slot in either type of mounting bracket used 13 Liebert MPX Installation and Assembly 3 2 Liebert MPX System Assembly 3 2 1 Attach an MPX PEM or MPX BRM to the MPX PRC WARNING Risk of arc flash and electric shock Can cause equipment damage injury or death This unit must be properly and securely installed on the MPX PRC Power Rail Chassis Emerson strongly recommends that the MPX PEM be installed only by an individual who has been properly trained and qualified to perform electrical work Connect only one MPX PEM Power Entry Module to an MPX PRC Power Rail Chassis Connecting more than one MPX PEM could cause cross conduction Cross conduction can cause upstream overcurrent protective devices OCPD trip or the resulting short circuit current may exceed the OCPD A I C ratings Whenever the MPX PEM 1s connected to power the connectors on the bottom are energized with hazardous voltage Connect input power only after the MPX PEM Power Entry Module is properly installed on the MPX PRC Power Rail Chassis the MPX
38. ngle and three phase NEMA and IEC plug types are available The MPX IPC is not required for the Fixed Capacity MPX PEM A Figure 5 WARNING Risk of arc flash and electric shock Can cause equipment damage injury or death Do not connect the MPX IPC to power until the MPX is attached to the MPX PRC and the MPX IPC is attached to the MPX PEM If the MPX PEM is not attached to the MPX PRC conductors with hazardous voltage will be exposed when power is connected MPX IPC connector Quick Connect Power Couplings Snap Locks prevent accidental disconnection from the MPX PEM Power Entry Module Liebert MPX System Modules 2 3 MPX BRM Branch Receptacle Module Power Output The MPX BRM provides output power distribution to user load equipment All MPX BRMs include output receptacles NEMA Schuko or IEC that are overload protected by 100 rated hydraulic magnetic circuit breakers MPX BRMs are hot swappable to allow user installation without powering down the Liebert MPX Up to three standard sized 266mm MPX BRMs can be deployed on a Liebert MPX utilizing the MPX PRC Power Rail Chassis for typical 23U racks and up to six standard size MPX BRMs Branch Receptacle Modules for units utilizing the 1880mm MPX PRC for typical 42U racks All MPX BRMs include an alphanumeric LED indicator that uniquely identifies the individual module North American and European models of the MPX BRM are available
39. nsor on a Knurr Miracel frame member 1 Assemble the Liebert SN and sensor bracket a Insert the sensor bracket base into one end of the sensor support as shown in Figure 16 b Snap the sensor into the other end of the sensor support 2 Choose where in the rack to install the sensor assembly Emerson recommends placing the sensor in the area that is likely to be warmest 3 Hold the sensor bracket on a T slot on the Knurr Miracel frame where the sensor will be placed 4 Insert the included quarter turn fastener through the rectangular hole in the sensor bracket base and into the T slot see Figure 16 5 Turn the fastener clockwise 90 degrees a quarter of a turn 6 Route the sensor cable to the Liebert RPC and insert it into the card s external sensor port For further details refer to the Liebert RPC user manual SL 20825 which shipped with the card and is available at Liebert s Web site www liebert com Figure 16 Temperature humidity sensor mounting Sensor Support Bracket Base Liebert SN Sensor Quarter Turn Fastener Rectangular protrusion passes through bracket slot above and into T slot on Knurr Miracel frame member below Liebert SN Sensor Cable 18 Liebert MPX Installation and Assembly 3 4 3 4 3 4 Install an Optional RPCBDM in the Rack The RPCBDM Basic Display Module can be mounted in the rack with either the included hardware or with a cable tie thro
40. ontrol to the receptacle level Liebert RPC Rack PDU Card optional network interface card to manage and monitor power distribution to connected equipment installs in the MPX PEM communication card slot Allows for multiple Liebert MPXs to be interconnected and managed from a single network connection RPCBDM lt Basic Display Module optional display for local monitoring of Liebert MPX units Cord connected allowing user to select rack mounting location Liebert MPX assembly diagram Liebert PRC runs full length of unit obscured by modules MPX BRM modules Liebert RPC Quick Connect Input MPX PEM module Liebert MPX System Modules 2 0 LIEBERT MPX SYSTEM MODULES 2 1 MPX Power Rail Chassis Power and Communication Bus The MPX acts as the fundamental building block of the Liebert MPX Power and Communications buses are integrated into the full length of the MPX The MPX BRM Branch Receptacle Modules and MPX PEM Power Entry Module lock onto the MPX PRC adding power input power output monitoring and management depending on the type of module The MPX PRC is available in two lengths Part Length mm in Typical Cabinet Size MPXPRC V1880XXX 1880 74 07 42U MPXPRC V1035XXX 1035 40 78 23U The MPXPRC V1880XXX will accommodate up to six standard size 266 mm MPX BRMs Branch Receptacle Modules the MPXPRC V1035XXX will accept
41. ped with power metering capability Other important features include Three visual phase power indicators alert the user to the current condition of each power input Audible alarm is enabled during certain overcurrent conditions The audible alarm may be tested or silenced by pressing the alarm silence test button The alarm may be tested by momentarily pressing the button when an alarm condition is not pending Liebert MPX System Modules Figure 4 2 2 1 MPX PEM Power Entry Module features Integral Connector Torx Screw Phase Power Indicators Liebert RPC Reset Access Hole Alarm Silence Test Button Liebert RPC Installed in Slot Hard Wired Power Input Cable w vos 09 Integral Connector Torx Screw pageasut padosd apum Jom Dd paulo YOOHS ONINEVAA Quick Connect Power Couplings 0001 2d3 Nd ng N ros 3 w WA qp uuop GUVZVH X2OHS ONINSVM Mbdt vvz ZH 09 2enovz soz ozt XdW 12d 2uo 250 MPX IPC Input Power Cord Communication North American Models Only The MPX IPC is a detachable input power cord that permits changing the input power source for Variable Capacity versions of the MPX A variety of si
42. r Switching amp Controls Services DC Power Infrastructure Management amp Monitoring Precision Cooling Surge Protection Emerson Business Critical Continuity Emerson Network Power and the Emerson Network Power logo are trademarks of Emerson Electric Co or one of its affiliated companies 2010 Emerson Electric Co
43. rt MPX contact Emerson Network Power Distributed Processing Applications or your local Emerson representative Do not attempt to service this product yourself Liebert MPX Introduction 1 0 LiEBERT MPX INTRODUCTION The Liebert MPX is an Adaptive Rack PDU power distribution unit built with modular and scalable components that can be installed and reconfigured on site to meet varying input and output power connectivity needs The flexibility of the modules requires that the installer ensure that the modules match the power requirements of the application Failure to do so could result in damage to the Liebert MPX and connected components The Liebert MPX Adaptive Rack PDU family consists of the following components Figure 1 MPX PRC Power Rail Chassis distributes intermodule power communications and serves as the mounting base for all Liebert MPX components MPX PEM Power Entry Module delivers power to the Liebert MPX and includes provisions for remote and local communication options Detachable and non detachable cord versions are available MPX IPC Input Power Cord is a detachable input power cord required for some versions of MPX PEM A variety of single and three phase plug types are available MPX BRM Branch Receptacle Module distributes overload protected output power to user loads Hot swappable design allows for reconfiguration with choice of receptacle type quantities and monitoring c
44. ser manual SL 20825 or quick start guide SL 20826 each available in the monitoring area of Liebert s Web site ww w liebert com 1 Locate the communication card bay on the MPX PEM You might need to remove a cover 2 Insert the Liebert RPC into the MPX PEM and secure it with the provided screws 3 The Liebert RPC has four ports designated by icons a LAN port Expansion Management port Display port and Sensor port Connect an Ethernet pm cable not included to the LAN port identified by the icon on the right LAN port 4 Connect the Ethernet cable to a computer 17 Liebert MPX Installation and Assembly 3 3 Temperature Humidity Sensor Installation Optional Optional Liebert SN temperature humidity sensors are available to assist in monitoring conditions in the rack Liebert SN sensors are designed for installation in a Knurr Miracel without tools but each may be placed in any area to monitor temperature and humidity levels Each connects to the Liebert RPC which makes readings available to Liebert MPX monitoring methods Only one mounting method is addressed in this manual attaching a single sensor with a bracket to a Knurr Miracel frame member For details on other mounting locations and methods refer to the Liebert SN quick start guide SL 20840 or to the Liebert RPC user manual SL 20825 Each is available at Liebert s Web site www liebert com To install a se
45. to the receptacle level The PDU Explorer is Web based software that displays a hierarchical view of the system Using PDU Explorer the user is able to browse components starting at the PDU level through to the branches of the PDU and down to the receptacles of those branches Figure 19 Liebert RPC PDU Explorer view PDU Explorer monitor control configure PDU Explorer support Rack PDU Information Uninitialized Fag Rack PDU Uninitialized Label Line Amps Load Load Status Information Uninitialized q T Ci pJ MPX Rack PDU L1 02 07 126 4 202 46 System Status MPX Rack PDU Normal with Alarm System Status alarms settings ratings Monitor Supported Status Value Pep PDU Accumulated Energy 8 2 kWH Receptacle Sequence PDU Voltage 122 VAC PDU Explorer PDU Current 0 2 A AC Options amp Device Explorer PDU Available Current Until Alarm 23 8 A AC Operations esses e PDU Percent Current Utilization 0 7 PDU Total Input Power 96 W PDU Apparent Power 20 8 PDU Power Factor 046 The Device Explorer shows the status and identification of all receptacles on a single PDU This list can be sorted by the supplied fields allowing quick navigation Associated links navigate to the PDU Explorer for viewing or configuring a receptacle Figure 20 Liebert RPC Device Explorer view Device Explorer monitor Device Explorer Recepta
46. ts session or call our worldwide technical support Channel Applications Engineering 800 222 5877 ext 1 Outside North America 800 1155 4499 ext 1 e mail liebert upstech emerson com Monitoring Applications Engineering 800 222 5877 ext 2 Outside North America 800 1155 4499 ext 2 e mail liebert monitoring emerson com RoHS Compliance The Liebert MPX modules comply with the Restriction of Hazardous Substances Directive RoHS prohibiting use of six hazardous materials manufacturing of electronics including lead free solder FCC Compliance This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment Off and On the user is encouraged to try to correct the interference by one or more of the following measures Reorienting or relocating the receiving antenna Increasing the separation between the equipment and
47. ugh the slot on the back of the module see Figure 17 Either method permits moving the RPCBDM to a different place in the same rack or to another rack 1 Mounting Hardware Spring nut M5 1 Spacer sleeve 1 Special MPX screw 1 Cable clip 1 Tools Required Flat blade screwdriver 2 RPCBDM Installation on Knurr Miracel Frame 1 Determine the mounting location in the rack 2 Insert a spring nut into a T slot on the frame member where the RPCBDM will be installed refer to Figure 9 3 Insert the Liebert MPX screw into the spacer sleeve Insert the Liebert MPX screw into the spring nut and tighten securely with the screwdriver 5 Hang the RPCBDM on the Liebert MPX screw with the hooded mounting slot on the back of the RPCBDM see Figure 17 6 Connect the RPCBDM to the Liebert RPC with an Ethernet cable Be certain to connect the cable to the correct port on the Liebert RPC see Figure 18 Figure17 RPCBDM installation in rack Cable tie fits in small slot on RPCBDM ee loops around cabinet gt member 9 7 Head of the Liebert MPX Screw in frame fits into hooded slot on back of RPCBDM 19 Liebert MPX Installation and Assembly Figure 18 RPCBDM cable connection port on Liebert RPC RPCBDM cable connection port on Liebert RPC Abs 120 208 240Vac 60 30A 24 KATAR ED NE MORE RATE CM Wie installed to MPX Use only one per
48. uit breakers on the MPX BRMs are Off 2 Connect the Liebert MPX unit to input power Validate that only one MPX PEM Power Entry Module is installed on the MPX PRC Power Rail Chassis Verify that the MPX PEM Power Entry Module and MPX BRM Branch Receptacle Module s operating voltages are the same and match the input power source Connect equipment to the MPX BRMs Make sure the equipment to be connected to the Liebert MPX is switched Off Attach communication cables to the Liebert RPC if one is installed in the Liebert MPX Switch On the circuit breaker of each MPX BRM where the load is connected Check the Phase Power Indicators on the MPX PEM to verify that input power is present not available on Elementary MPX PEM models The appropriate number of lights on the MPX PEM should be green and lit but not flashing input power is single phase L1 should be green input power is single phase 208 240VAC North America only L1 and L2 should be green input power is three phase L1 L2 and L3 should be green 8 Verify that each attached MPX BRM 1 displaying a non repeated identifying number in the Number Indicator beside the circuit beaker the identifying numbers order in the display may not match the mapping of their physical location on the MPX PRO not available on Elementary MPX BRM models 9 Switch On the test equipment or connected load to verify proper operation 10 If any MPX BRMs are Receptacle Management
49. ules Ratings Length BRM Model mm U 266mm PEM Ampere A Voltage V Weight Ib kg MPXPRC V1880xxx 1880 42 6 266mm 1 220mm 4 76 2 16 63 240 415 MPXPRC V1035xxx 1035 23 3 266mm 1 266mm 2 62 0 84 26 Specifications 72 MPX PEM Model Number Configuration Prefix MPXPEM Region N North America E European Type V Variable Capacity H Fixed Capacity Size Small 220mm B Standard 266mm Communication A RPC Installed X RPC Not Installed E Not Available Input Power Variable Capacity PEM Plug Style X Standard APP Service A NA 30A120 208V and EU 32A 230 400V B NA 30A 240 415V Remaining Positions Use X Fixed Capacity Plug Style X Standard Straight S Special R Right Angle Service if Plug X R F L6 30P H L21 30P I L22 30P M L7 30P Q EU IEC309 32A 230V 1P2W PE R EU IEC309 32A 230 400V 3P4W PE S EU IEC309 16A 230V 1P2W PE T EU IEC309 16A 230 400V 3P4W PE V NA CS8365C 50A 3P3W PE 208 240V W NA IEC309 60 120 208 240V 3P4W PE X NA IEC309 60A 208 240V 3P3W PE Y NA IEC309 60 240 415V 3P4W PE Z EU IEC309 63A 230 400V 3P4W PE Cord Length nominal if Plug X R Reflect meters with two digits e g 30 3 0m If Plug S the Service and Cord fields are combined as a numerical value only e g 001 Table 2 MPX PEM Power Entry Module specifications Input Ratin
50. ure 9 for how to insert a spring nut 2 Position the spring nuts where the brackets to be used will be positioned either the Z shaped or L shaped brackets To move a spring nut press down on it with a small pointed object and slide it into position 3 Thread an MPX mounting screw into the spring nut and tighten a few turns Leave enough space for the bracket to slip over the screw s head and rest on the body of the screw Figure9 Inserting a spring nut into a T slot and attaching an MPX mounting screw MPX Mounting Screw in back of MPX PRC T slot Spring nut installed in T slot leaf spring goes on inner side 3 1 4 Attach Brackets to a Knurr Miracel Horizontal Frame Member 1 Insert two spring nuts into the T slot on the upper horizontal frame member a To use the Z shaped bracket insert the spring nuts into the T slot on the face of the horizontal frame member see Figure 10 b To use the L shaped bracket insert the spring nuts into the T slot on the thinner side of the horizontal frame member see Figure 10 2 Position the spring nuts to accommodate screws inserted through slots in the brackets To move the spring nuts press down on each with a small pointed object and slide each into position 3 Hold the bracket in place and attach it with two of the M5x10 screws with hex heads 4 Tighten the hex head screws firmly with the Allen wrench 5 Repeat Steps 1 through 4 for the lower horizontal
51. versions the lights beside the receptacles should be lit 9501 egeo 21 Operation and Configuration 5 0 OPERATION AND CONFIGURATION 5 1 A Liebert MPX can be operated with or without the optional Liebert RPC Rack PDU Card The card employs a Web based interface to enhance monitoring and control enabling users to manage rack equipment locally or from a remote location The Liebert RPC can be used to determine power usage switch receptacles on some units On and Off and troubleshoot input power supply problems The Liebert RPC will manage and monitor different types of MPX BRMs Branch Receptacle Modules installed on the same Liebert MPX The feature can be valuable when some rack equipment connected to the Liebert MPX requires closer monitoring than other equipment The Liebert RPC supports managing and monitoring the Liebert MPX with SNMP Liebert Nform Liebert SiteScan and third party management systems When connecting the rack equipment to the Liebert MPX s receptacles arrange cables and connections to avoid tangling and crisscrossing the power cables For power management purposes record the receptacle where each piece of equipment is connected Receptacles on the Liebert MPX have a numerical designation Liebert MPX with more than one circuit has the outlets named with numbers and are grouped by branch with a number referring to the proper circuit breaker Configure the Liebert RPC The Liebert RPC is
52. while properly installed to MPX By one per MPx EMERSON c us Liebert RPC Liebert MPX System Modules 2 4 4 RPCBDM RPC Basic Display Module The optional RPCBDM provides local display of monitored data for all connected Liebert MPX and Liebert MPH systems Display information is accessed via a navigation switch on the RPCBDM The RPCBDM is cable connected to the Liebert RPC allowing the user to locate the display to suit the local reading requirements A 2 meter cable and general mounting provisions are provided single display can be used for up to four Liebert MPX or Liebert MPH Rack PDUs connected in a Rack PDU Array The display screen s orientation may be changed to either landscape default or portrait by pressing and holding the scan switch while attaching the cable Figure8 RPCBDM EMERSON Network Power 10 Liebert MPX Installation and Assembly 3 0 LIEBERT MPX INSTALLATION AND ASSEMBLY All configuration steps must be completed before attempting to startup equipment connected to the Liebert MPX 3 1 Installation in a Knurr Miracel Rack Emerson recommends installing the MPX PRC Power Rail Chassis in the rack then attaching the Liebert MPX modules to it Before beginning consider how cables will be routed in the rack Placing the MPX PEM Power Entry Module at the end of the MPX PRC that is nearest the entry point for its input power cable