1. head lights without any additional accessories Especially the MAVOLUX 5032 B USB having an initial sensitivity of 0 01 Ix also allows measuring extremely low light intensities such as emergency lighting Most important Due to its high precision acc to Class B the MAVOLUX 5032 B USB has been approved for certification and official inspection procedures hen attaching the Luminance Attachment to the measuring probe of the MAVOLUX 5032 C or B USB they can be used also for measuring the luminance the measuring angle being approx 20 Luminance is the reflected light effect of self luminous or reflecting surfaces The measuring unit is candela per square meter cd m or foot Lambert fL Calibration Certificate When required to be specificly ordered together with the lightmeter Please see page 12 of this brochure for more information 2 Gossen Foto und Lichtmesstechnik GmbH GOSSEN MAVOLUX 5032 C B USB Specifications Modi MAVOLUX 5032 C USB MAVOLUX 5032 B USB Ty Illuminance meter for measuring light Class C acc DIN 5032 7 Class B acc DIN 5032 7 we 3 1 2 digits FCD DISpiay A with backlight display illumination Light sensor Silicon photo diode with V A filtering Lux or footcandle fc and with Luminance Attachment cd m or Measuring unit foot Lambert fL Automatic and manual measuring range selection 0 1 Ix to 199 900 Ix and 0 01 Ix to 199 900 Ix and 1 cd m to 1 999 000 cd m in 0 1 cd m to 1 9
2. 99 000 cd m in 4 ranges with Luminance 5 ranges with Luminance Attachment Attachment 100 individual measuring values 2 measurements per second USB Port USB 1 1 Operating 0 C to 50 C temperature According EN 61010 1 2001 cl 1 4 1 Storage 20 C to 70 C temperature Measuring ranges Power sinni 1x 1 5 V size AA when meter is connected to PC PPly power will be supplied via USB cable Software gLux Software and additional applications Connection cable 1 5 m cable firmly attached 1 5 m cable plugged in Weight 200 g without battery Standard Lightmeter in transport case gLux Software incl meter driver Accessories USB cable battery instruction manual Luminance Attachment measuring angle 20 Adapter disk for luminance contact measurement eliminating light incident from the sides Optional Accessories Applications Examples Pesci ine Sule eae Sports Arenas TV Studios lighting in emergency exits Gossen Foto und Lichtmesstechnik GmbH 3 GOSSEN MAVOLUX 5032 C B USB Optional accessories Luminance Attach ment Adapter disk for eliminating light inciding from the sides with contact measurement The MAVOLUX 5032 C B USB is supplied i Measuring probe with in a practical and compact transport case Luminance Attachment mounted and Adapter disk Ordering information Description Ordering code MAVOLUX 5032 C USB M502G incl transport case software USB cable ba
3. GOSSEN MAVOLUX 5032 C B USB illuminance meters of the precision class C or B Features e Precision meters for measuring the illuminance in Lux and Footcandles meeting Standard Specification DIN 5032 7 Class C or B and EN 13032 1 Appendix B e The silicon photo diode is colour corrected i e its spectral responsitivity is matched to the photopic daylight vision of the human eye V A e Luminance can be measured in cd m or fL when using the Luminance Attachment optional accessory e Cosine correction for light inciding at an angle e Easy to use e 3 digits display e Backlight display illumination only in MAVOLUX 5032 B USB e Data storage of up to 100 measurements e Auto and manual range selection e USB Port 1 1 e CD Rom with software for processing the values measured and controlling the meter e Compact transport case and USB cable included he GOSSEN digital precision luxmeters are classified according to DIN 5032 7 in Class C or B and EN 13032 1 Appendix B Wide range of applications for lighting engineers and specifiers for the control of light sources street lights lighting of work places public buildings sport facilities for quality control and quality assurance in the manufacture of lamps and light sources for light designers and architects for light measurements in agriculture gardening and forestry oth MAVOLUX types are optimally suited for measuring very high light intensities brightest daylight
4. ttery instruction manual MAVOLUX 5032 B USB M503G incl transport case software USB cable battery instruction manual Calibration Certificate for Mavolux 5032 C B USB please see page 12 H997B Accessories for MAVOLUX 5032 C B USB Luminance Attachment for measuring in cd m and fL 5908V0120 Adapter disk for contact measurement for use only with the Luminance M499G Attachment Special length cables for MAVOLUX 5032 C or B USB 3 meters for MAVOLUX 5032 C USB 5 meters for MAVOLUX 5032 C USB 10 meters for MAVOLUX 5032 C USB 3 meters for MAVOLUX 5032 B USB 5 meters for MAVOLUX 5032 B USB 10 meters for MAVOLUX 5032 B USB The extra length cables and the Calibration Certificates must be ordered already together with the meters 4 Gossen Foto und Lichtmesstechnik GmbH
Download Pdf Manuals
Related Search
Related Contents
Star Micronics Star NX-500 User's Manual Fujitsu PRIMERGY RX200S7 Entretien ou ensemencement des fosses septiques et des Dynatron A5JG Equator CLOTHES-PROCESSOR EZ 3600 CEE User's Manual concernant l`allocation de chauffage à partir du 1er septembre 2005 Manual de Consultas Copyright © All rights reserved.
Failed to retrieve file